PubMed Health⌕ Search

Biomedical subjects

Peter Koken

Publications and source records attributed to Peter Koken.

4 recordsLinked to original sources

Circular CT in combination with a helical segment.

The combination of circular CT with a helical trajectory segment results in a mathematically complete data set. We present a reconstruction algorithm which is mathematically exact and of the filtered back-projection type. The algorithm ensures that only Radon planes which are not covered along the circle are taken into account, when data from the helical segment are back-projected. Therefore, the helical segment contributes only to low-frequency parts of trans-axial slices. Data along the helix can be obtained with a very low acquisition dose.

Algorithms↗

The radon-split method for helical cone-beam CT and its application to nongated reconstruction.

The mathematical analysis of exact filtered back-projection algorithms is strictly related to Radon inversion. We show how filter-lines can be defined for the helical trajectory, which serve for the extraction of contributions of particular kinds of Radon-planes. Due to the Fourier-slice theorem, Radon-planes with few intersections with the helix are associated with low-frequency contributions to transversal slices. This insight leads to different applications of the new method. The application presented here enables the incorporation of an arbitrary amount of redundant data in an approximate way. This means that the back-projection is not restricted to an n-Pi interval. A detailed mathematical analysis, in which we demonstrate how the defined filter-lines work, concludes this paper.

Algorithms↗

CEnPiT: helical cardiac CT reconstruction.

Computer tomography (CT) scanners with an increasing number of detector rows offer the potential of shorter scanning times. Nevertheless, the reconstruction problem becomes more challenging, since cone beam artifacts are likely to enter. Here, we consider helical cardiac CT. We analyze how a relationship can be established between exact reconstruction algorithms and the demand to perform a cardiac gating. Utilizing the redundancies requires the consideration of all kinds of Radon planes. For the reconstruction algorithm proposed here, we separate the data into two parts. The first part contains contributions of Radon planes, which are measured with a large number of redundancies. The second part contains the remaining contributions. As it turns out, the second part contributes rather to the low-frequency contents of trans-axial slices. Therefore, we propose to perform a gated back-projection only for the first part, while the second part is back-projected in an ungated way. Data from the complete source trajectory are employed in the reconstruction process in contrary to conventional helical cardiac reconstruction methods. Moreover, all different types of Radon planes are taken into account in the reconstruction, though an ECG-dependent cardiac gating is applied. The reconstruction results, which we present for clinical and simulated data, demonstrate the high potential of CEnPiT for helical cardiac CT with large cone angle systems.

Algorithms↗

Combined high-resolution and real-time imaging: a technical feasibility study on coronary magnetic resonance angiography.

PURPOSE: To propose a new approach to combining high-resolution and real-time imaging and to show its technical feasibility on the example of coronary magnetic resonance angiography. MATERIALS AND METHODS: The insertion of fast two-dimensional (2D) acquisitions into time intervals that have not been utilized by triggered or gated 2D or three-dimensional (3D) acquisitions so far is suggested, as well as the immediate reconstruction and display of the additional data. For a technical validation of this concept, a 2D ventricular function protocol was interleaved into a cardiac-triggered and respiratory-gated 3D coronary angiography protocol. Dedicated hardware was employed to rapidly process the data originating from the former. Since the sampling of the latter was restricted to intervals with minimal motion, remaining periods of time could be used to simultaneously image the cardiac and respiratory motion. RESULTS: The technical feasibility of the proposed approach was demonstrated by successful measurements with the combined high-resolution and real-time protocol in volunteers. All examinations provided short axis views during the acquisition and angiograms of selected parts of the coronary system after its completion. CONCLUSION: The investigated concept allows high-resolution measurements to be complemented with real-time imaging functionality without affecting the scan time or image quality. In the particular application considered, an image-based patient monitoring or motion correction is enabled, indicating potential benefits of combining two very dissimilar methods of data acquisition in one measurement.

Coronary Circulation↗