PubMed Health⌕ Search

Biomedical subjects

Peter Lysyansky

Publications and source records attributed to Peter Lysyansky.

8 recordsLinked to original sources

Assessment of myocardial regional strain and strain rate by tissue tracking in B-mode echocardiograms.

To date, established ultrasonic methods for myocardial regional deformation recovery are based on the Doppler effect, which has inherent limitations restricting its accuracy and use. The reported time domain methods show in vivo insufficient accuracy. A novel approach is elaborated mimicking the human observer who reaches robust diagnosis upon the B-mode data. In a region-of-interest (ROI), acoustic markers stable for tracking are selected. A weighting index presenting the quality of tracking of each marker is used for spatial polynomial fitting. For the feasibility study, a simple straight ROI was selected, which matches the septum. A thorough proof of concept is provided by comparing with a gold standard method and by applying the method to clinical datasets. The peak systolic longitudinal strains of 12 normals were -15% + -2.3% and, of 12 patients with a light-to-mild dysfunction of the apical-septal segment, they were -9% + -0.8% (p < 0.05). Enhancements of the method using spline fitting are introduced.

Algorithms↗

Delineation of cardiac twist by a sonographically based 2-dimensional strain analysis method: an in vitro validation study.

OBJECTIVE: Normal left ventricular contraction involves a twisting component that helps augment stroke volume, the unwinding of which also very usefully contributes to early diastolic filling. Abnormalities of cardiac twist have been related to abnormal cardiac function. We sought to quantify the twisting action using a new sonographically based angle-independent motion-detecting echo method. METHODS: A twist model was developed with a variable-speed motor to rotate a wheel in water bath. A freshly harvested pig heart was mounted on it as a twist phantom. Short axis views were acquired with a GE/VingMed Vivid 7 system (GE Healthcare, Milwaukee, WI) at 3.5 MHz and more than 100 frames/s. Eight different speeds (30-100 cycles/min of winding and unwinding) were studied at 5 degrees of rotation (10 degrees , 20 degrees , 30 degrees , 40 degrees , and 50 degrees ). Data were analyzed off-line for twist analysis with a new 2-dimensional speckle-tracking-based program (2-dimensional strain rate method [2DSR]) embedded in EchoPac software (GE Healthcare). Ten freshly harvested pig hearts were studied in this model. RESULTS: The 2DSR program tracked the twist well (mean determination at 10 degrees = 16.88 degrees +/- 1.81 degrees [SD]; at 20 degrees = 26.5 degrees +/- 1.05 degrees ; at 30 degrees = 36.47 degrees +/- 1.31 degrees ; at 40 degrees = 44.03 degrees +/- 1.39 degrees ; and at 50 degrees = 54.1 degrees +/- 1.96 degrees ). CONCLUSIONS: The 2DSR program can be used to study twisting action of the heart.

Animals↗

Two-dimensional acoustic pattern derived strain parameters closely correlate with one-dimensional tissue Doppler derived strain measurements.

BACKGROUND: Two-dimensional strain echocardiography (2D-SE) calculates tissue velocities via frame-to-frame tracking of unique acoustic markers within the image and provides strain parameters in two dimensions. Novel 2D-SE software allows semi-automated strain measurements and increased averaging capabilities optimizing signal-noise ratio. AIM: We tested whether 2D-SE and the currently used and well-validated tissue Doppler derived strain echocardiography (TD-SE) yield similar information in the clinical setting. METHODS AND RESULTS: We performed 2D-SE and TD-SE on 17 patients with amyloid cardiomyopathy and 10 age-matched healthy volunteers. Single walls from standard apical views (2- and 4-chamber) were acquired at high frame rates ( approximately 200fps). Offline analysis was performed by observers blinded to clinical data using the EchoPAC program with custom 2D-SE software. Longitudinal strain rate and strain from the basal, mid and apical segments of the septal and lateral walls were determined by each method (TD-SE and 2D-SE). Ejection fraction was >0.55 in healthy volunteers and ranged from 0.30 to 0.80 in cardiomyopathy group. A total of 54 walls (162 segments) were examined. Acceptable quality strain data was available in 92% and 85% segments by 2D-SE and TD-SE, respectively. Two-dimensional strain echocardiography values correlated closely with TD-SE values (r=0.94 and 0.96 for strain rate and strain, respectively). CONCLUSIONS: Deformation analysis by 2D-SE is feasible in a clinical setting and 2D-SE values correlate closely with TD-SE measurements over a wide range of global systolic function. Two-dimensional strain echocardiography may help to facilitate the routine clinical implementation of deformation analysis.

Acoustics↗

Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging.

OBJECTIVES: We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). BACKGROUND: Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. METHODS: We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. RESULTS: Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. CONCLUSIONS: The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.

Echocardiography↗

Global longitudinal strain: a novel index of left ventricular systolic function.

BACKGROUND: Echocardiographic estimation of global left ventricular (LV) function is subjective and time consuming. Our aim was to develop a novel approach for assessment of global LV function from 2-dimensional echocardiographic images METHODS: Novel computer software for tissue tracking was developed and applied as follows: digital loops were acquired from apical 2-, 3-, and 4-chamber views and a line was loosely traced along the LV endocardium at the frame wherein it was best defined. Around this line, the software selected natural acoustic markers moving with the tissue. Automatic frame-by-frame tracking of these markers during the heart cycle yielded a measure of contractility along the selected region of interest. Global longitudinal strain (GLS) and GLS rate (GLSR) were calculated for the entire U-shaped length of LV myocardium (basal, mid, and apical segments of 2 opposite walls in each view). To test this software, computer-derived GLS and GLSR were analyzed by a nonechocardiographer, blinded to the echocardiographic interpretation, in 27 consecutive patients after myocardial infarction (MI) (age 64.4 +/- 12.9 years; 19 men; mean wall-motion score index of 1.79 +/- 0.44) and compared with those obtained in 12 consecutive control patients (age 59.0 +/- 9.7 years; 8 women), with a normal echocardiographic study. RESULTS: GLS and GLSR, averaged from the 3 apical views, differed significantly in patients post-MI compared with control patients (GLS -14.7 +/- 5.1% vs -24.1 +/- 2.9% and GLSR -0.57 +/- 0.21/s vs -1.02 +/- 0.09/s for patients post-MI vs control patients, respectively; both P <.0001). There was a good linear correlation between the wall-motion score index and the GLS and GLSR (R = 0.68 and R = 0.67, respectively; both P <.0001). A cut-off value for GLS of -21% had 92% sensitivity and 89% specificity and a cut-off value for GLSR -0.9/s had 92% sensitivity and 96% specificity for the detection of patients post-MI. CONCLUSIONS: GLS and GLSR are novel indices for assessment of global LV function from 2-dimensional echocardiographic images. Early validation studies with the method are suggestive of high sensitivity and specificity in the detection of LV systolic dysfunction in patients post-MI.

Adult↗

Two-dimensional strain-a novel software for real-time quantitative echocardiographic assessment of myocardial function.

OBJECTIVES: We sought to assess the feasibility of 2-dimensional strain, a novel software for real-time quantitative echocardiographic assessment of myocardial function. METHODS: Conventional and a novel non-Doppler-based echocardiography technique for advanced wall-motion analysis were performed in 20 patients with myocardial infarction and 10 healthy volunteers from the apical views. Two-dimensional strain is on the basis of the estimation that a discrete set of tissue velocities are present per each of many small elements on the ultrasound image. This software permits real-time assessment of myocardial velocities, strain, and strain rate. These parameters were also compared with Doppler tissue imaging measurements in 10 additional patients. RESULTS: In all, 80.3% of infarct and 97.8% of normal segments could be adequately tracked by the software. Peak systolic strain, strain rate, and peak systolic myocardial velocities, calculated from the software, were significantly higher in the normal than in the infarct segments. In the 10 additional patients, velocities, strain, and strain rate obtained with the novel software were not significantly different from those obtained with Doppler tissue imaging. CONCLUSION: Two-dimensional strain can accomplish real-time wall-motion analysis, and has the potential to become a standard for real-time automatic echocardiographic assessment of cardiac function.

Adult↗

The combined effect of nonlinear filtration and window size on the accuracy of tissue displacement estimation using detected echo signals.

In cardiac elastography, the regional strain and strain rate imaging is based on displacement estimation of tissue sections within the heart muscle carried out with various block-matching techniques (cross-correlation, sum of absolute differences, sum of squared differences, etc.). The accuracy of these techniques depends on a combination of ultrasonic imaging parameters such as ultrasonic frequency of interrogation, signal-to-noise ratio, size of a kernel used in a block-matching algorithm, type of data and speckle decorrelation. In this paper, we discuss the possibility to enhance the accuracy of the displacement estimation via nonlinear filtering of B-mode images before block-matching operation. The combined effect of a filter algorithm and a kernel size on the accuracy of the displacement estimation is analyzed using a 36-frame sequence of grayscale B-mode images of a human heart acquired by an ultrasound system operating at 1.77 MHz. It is shown that the nonlinear filtering of images enables to obtain the desired accuracy (less than one pixel) of the displacement estimation with smaller kernels than without filtering. These results are obtained for two filters--an adaptive anisotropic diffusion filter and a nonlinear Gaussian filter chain.

Algorithms↗

Improving motion estimation by accounting for local image distortion.

Cardiac elastography is a useful diagnostic technique for detection of heart function abnormalities, based on analysis of echocardiograms. The analysis of the regional heart motion allows assessing the extent of myocardial ischemia and infarction. In this paper, a new two-stage algorithm for cardiac motion estimation is proposed, where the data is taken from a sequence of 2D echocardiograms. The method combines the advantages of block-matching and optical flow techniques. The first stage employs a standard block-matching algorithm (sum of absolute differences) to provide a displacement estimate with accuracy of up to one pixel. At the second stage, this estimate is corrected by estimating the parameters of a local image transform within a test window. The parameters of the image transform are estimated in the least-square sense. In order to account for typical heart motions, like contraction/expansion, translation and rotation, a local affine model is assumed within the test window. The accuracy of the new algorithm is evaluated using a sequence of 500 grayscale B-mode images, which are generated as distorted, but known copies of an original ROI, taken from a real echocardiogram. The accuracy of the motion estimation is expressed in terms of errors: maximum absolute error, root-mean-square error, average error and standard deviation. The errors of the proposed algorithm are compared with these of the known block-matching technique with cross-correlation and interpolation in the sub-pixel space. Statistical analysis of the errors shows that the proposed algorithm provides more accurate estimates of the heart motion than the cross-correlation technique with interpolation in the sub-pixel space.

Algorithms↗