PubMed Health⌕ Search

Biomedical subjects

Peter M Quesada

Publications and source records attributed to Peter M Quesada.

4 recordsLinked to original sources

A two-input sliding-mode controller for a planar arm actuated by four pneumatic muscle groups.

Multiple-input sliding-mode techniques are applied to a planar arm actuated by four groups of pneumatic muscle (PM) actuators in opposing pair configuration. The control objective is end-effector tracking of a desired path in Cartesian space. The inputs to the system are commanded input pressure differentials for the two opposing PM groups. An existing model for the muscle is incorporated into the arm equations of motion to arrive at a two-input, two-output nonlinear model of the planar arm that is affine in the input and, therefore, suitable for sliding-mode techniques. Relationships between static input pressures are derived for suitable arm behavior in the absence of a control signal. Simulation studies are reported.

Arm↗

A study of computer-based task performance under thermal stress.

A visual-visual dual computer task was designed to test the effect of the thermal environment on dual task performance. The temperatures selected for testing were 20 and 35 degrees C Wet Bulb Globe Temperature (WBGT). 34 volunteers were randomly assigned to 1 of the 2 temperature conditions. Individual differences in single task performance were controlled by equating the baselines of single task performance. Once individual differences in single task capacity were controlled, statistically significant differences in performance were demonstrated. Mean accuracy was computed over a 1-hr testing period in each temperature condition. Participants' mean accuracy in the 35 degrees condition (38.18%) was substantially lower than in the 20 degrees condition (50.88%).

Adult↗

The use of end-to-side nerve grafts to reinnervate the paralyzed orbicularis oculi muscle.

Facial paralysis is a serious neurologic disorder, particularly when it affects the eye. Loss of the protective blink reflex may lead to corneal ulceration and, possibly, visual loss. The purpose of this study was to compare different nerve-grafting techniques to reanimate the paralyzed eyelid. Sixteen adult dogs (25 kg each) were allocated into four groups. Denervation of the left hemi-face was performed in all cases. One dog served as a control animal (group I). Group II dogs (n = 5) underwent end-to-side coaptation of the nerve graft to the intact palpebral branch and end-to-end coaptation to the denervated palpebral branch. Group III dogs (n = 5) underwent end-to-end coaptation of the nerve graft to the intact palpebral branch and end-to-end coaptation to the denervated palpebral branch. Group IV dogs (n = 5) underwent end-to-side coaptation of the nerve graft to the intact and denervated palpebral branches. The animals were monitored for 9 months after the surgical procedures, to allow adequate time for reinnervation. The dogs were postoperatively monitored with clinical observation, electrophysiologic testing, video motion analysis, and histologic assessments. Clinical observation and electrophysiologic testing demonstrated the production of an eye blink in the denervated hemi-face in all experimental groups. There was a trend toward increased speed of reinnervation for group III animals (end-to-end coaptations). It was concluded that end-to-side coaptation can produce a contralateral synchronous eye blink in a clinically relevant, large-animal model.

Animals↗

The effects of cycling shoe stiffness on forefoot pressure.

Plantar pressure data were recorded in two different shoe types to determine the effect of cycling shoe stiffness on peak plantar forefoot pressure in cyclists. Two pairs of shoes of the same size and manufacturer, identical except for outsole material and stiffness, were tested. Shoe stiffness measurements were collected under controlled conditions and in two different configurations using a dynamic hydraulic tensile testing machine. Measurements of plantar pressure were done using Pedar capacitive-based sensor insoles while subjects pedaled in a seated position at a controlled power output. Power output was set at a constant value of 400 W across all subjects by a magnetic resistance trainer unit. The pressure distribution in carbon-fiber-composite shoes during cycling was compared to cycling shoes made with plastic soles. Carbon fiber shoes presented stiffness values 42% and 550% higher than plastic shoes in longitudinal bending and three-point bending, respectively. The shoes made with carbon fiber produced peak plantar pressures 18% higher than those of plastic design (121 kPa vs. 103 kPa, p = .005). Competitive or professional cyclists suffering from metatarsalgia or ischemia should be especially careful when using carbon fiber cycling shoes because the shoes increase peak plantar pressure, which may aggravate these foot conditions.

Adult↗