PubMed Health⌕ Search

Biomedical subjects

Peter MacEneaney

Publications and source records attributed to Peter MacEneaney.

12 recordsLinked to original sources

Automated interpretation of regional left ventricular wall motion from cardiac magnetic resonance images.

UNLABELLED: Magnetic resonance (MR) diagnosis of regional left ventricular (LV) dysfunction relies on visual interpretation of cine images that suffers from wide inter-observer variability, especially when performed by readers not specifically trained in the assessment of LV wall motion. Quantitative analysis tools, though widely available, are rarely used because they provide large amounts of detailed information, the interpretation of which requires additional time-consuming processing. We tested the feasibility of fast automated interpretation of regional LV function using computer analysis of this wall motion information. METHODS: Dynamic, ECG-gated, steady-state free precession short-axis images were obtained in 6-10 slices in 28 subjects (10 normal volunteers; 18 patients). Images were reviewed by an expert cardiologist who provided "gold standard" grades (normal, abnormal) for regional wall motion and, independently, by four radiologists. Same images were then analyzed using custom software. Regional fractional area changes computed in normal volunteers were used to obtain the optimal segment- and slice-specific threshold values for automated classification of regional wall motion for each patient. The levels of agreement with the "gold standard" grades were compared between the radiologists and the automated interpretation. RESULTS: While the visual interpretation required 2-5 minute per patient, the automated interpretation required < 1 sec, after endocardial border detection was complete. The automated interpretation resulted in higher sensitivity, specificity, and accuracy (84%, 77%, 79%, respectively) than the radiologists' grades (80%, 76%, 77%, respectively) and eliminated the high interobserver variability. CONCLUSION: Once the endocardial boundaries are defined, computer analysis of the regional wall motion information allows accurate, fully automated, immediate, objective and experience-independent interpretation of regional LV function.

Automation↗

Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images.

BACKGROUND: Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. METHODS AND RESULTS: RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM)-time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data (linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r=0.98; y=0.99x+2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/-20 mL). WM correlated highly only in basal and midventricular segments (r=0.88; y=0.85x+0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. CONCLUSIONS: Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.

Adult↗

Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging.

Our goals were to: (1) develop a technique for 3-dimensional (3D) direct, model-independent quantitative assessment of left ventricular (LV) volume and ejection fraction based on semiautomated detection of LV endocardial surface from transthoracic near real-time full matrix-array 3D echocardiographic (FM3DE) imaging; (2) evaluate the accuracy of LV volumes obtained with this technique, using cardiac magnetic resonance imaging (MRI) measurements as the reference for comparison; and (3) determine the effects of contrast enhancement on the accuracy of FM3DE measurements. A total of 46 patients underwent 2-dimensional echocardiography, FM3DE, and cardiac MRI. End-diastolic volume, end-systolic volume, and ejection fraction were derived from endocardial borders manually traced from 2-dimensional echocardiographic images and from semiautomatically detected LV cavity from FM3DE data. In 14 patients, FM3DE was also acquired with contrast. All measurements were compared with MRI values using linear regression and Bland-Altman analyses. FM3DE was feasible in 44 of 46 patients with LV volumes < 345 mL. LV volumes and ejection fraction computed from FM3DE resulted in higher levels of agreement with MRI than conventional 2-dimensional echocardiography, with lower interobserver variability. With contrast enhancement, FM3DE significantly underestimated LV volumes and showed increased interobserver variability. Semiautomated LV endocardial surface detection from FM3DE images is feasible and results in fast and accurate assessment of LV function.

Adult↗

Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models.

PURPOSE: The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. METHODS: Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. RESULTS: VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and -9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). CONCLUSION: VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.

Cardiac Volume↗

Fast measurement of left ventricular mass with real-time three-dimensional echocardiography: comparison with magnetic resonance imaging.

BACKGROUND: Left ventricular (LV) mass is an important predictor of morbidity and mortality, especially in patients with systemic hypertension. However, the accuracy of 2D echocardiographic LV mass measurements is limited because acquiring anatomically correct apical views is often difficult. We tested the hypothesis that LV mass could be measured more accurately from real-time 3D (RT3D) data sets, which allow offline selection of nonforeshortened apical views, by comparing 2D and RT3D measurements against cardiac MR (CMR) measurements. METHODS AND RESULTS: Echocardiographic imaging was performed (Philips 7500) in 21 patients referred for CMR imaging (1.5 T, GE). Apical 2- and 4-chamber views and RT3D data sets were acquired and analyzed by 2 independent observers. The RT3D data sets were used to select nonforeshortened apical 2- and 4-chamber views (3DQ-QLAB, Philips). In both 2D and RT3D images, LV long axis was measured; endocardial and epicardial boundaries were traced, and mass was calculated by use of the biplane method of disks. CMR LV mass values were obtained through standard techniques (MASS Analysis, GE). The RT3D data resulted in significantly larger LV long-axis dimensions and measurements of LV mass that correlated with CMR better (r=0.90) than 2D (r=0.79). The 2D technique underestimated LV mass (bias, 39%), whereas RT3D measurements showed only minimal bias (3%). The 95% limits of agreement were significantly wider for 2D (52%) than RT3D (28%). Additionally, the RT3D technique reduced the interobserver variability (37% to 7%) and intraobserver variability (19% to 8%). CONCLUSIONS: RT3D imaging provides the basis for accurate and reliable measurement of LV mass.

Adult↗

The role of still-frame parametric imaging in magnetic resonance assessment of left ventricular wall motion by non-cardiologists.

BACKGROUND: Cardiac magnetic resonance (MR) images are often reviewed by non-cardiologists who are not trained in the interpretation of regional left ventricular (LV) function. We hypothesized that the use of still-frame parametric MR images of wall motion could aid in the assessment of regional LV function. METHODS: Dynamic, electrocardiogram-gated, steady-state free precession (FIESTA) short-axis images were obtained in 6 to 10 slices in 18 consecutive patients. Each loop was used to automatically generate a still-frame image, in which each pixel is assigned a value equal to the amplitude of cyclic variation in local intensity, resulting in higher intensity in pixels that change between blood and tissue during the cardiac cycle. The dynamic images were reviewed by an expert cardiologist who provided gold standard grades for regional wall motion and by four radiologists. Then the radiologists reviewed and graded the same MR images in combination with parametric images. Grades assigned to each segment in the two sessions were compared with the gold standard. RESULTS: According to expert interpretation, 6 patients had normal wall motion, and 12 had wall motion abnormalities. Parametric images showed a bright band in the area spanned by endocardial motion, with reduced brightness and thickness in areas of hypokinesis. The agreement between the radiologists' grades and the gold standard significantly improved by adding parametric images (from 77% to 81%), which also resulted in reduced interobserver variability (from 52% to 33%). CONCLUSIONS: Still-frame parametric images aid in the assessment of regional wall motion by non-cardiologists who are required to interpret cardiac images.

Female↗

Structure of the water resonance in small voxels in rat brain detected with high spectral and spatial resolution MRI.

PURPOSE: To acquire high spectral and spatial resolution (HiSS) MR images of the water resonance in rat brain, evaluate the lineshape of the water resonance in small voxels, and compare images derived from HiSS data with conventional images. MATERIALS AND METHODS: Spectroscopic images of rat brain were obtained at 4.7 Tesla using phase encoding gradients only. Spectral resolution in each voxel was approximately 8 Hz and bandwidth was 1,000 Hz. Spatial resolution was approximately 250 microns in 1-mm slices. Images were synthesized to show the water signal integral, peak height, linewidth, resonance frequency, and asymmetry. RESULTS: Two or more resolved components of the water resonance were detected in approximately 14% +/- 6% of voxels in the brains of eight rats. The water resonances in approximately 20% +/- 10% of voxels (n = 8) were highly asymmetric. Images with intensity proportional to water signal peak height, T(2)*, or to selected components of the water resonance showed features that were not evident in conventional images. CONCLUSIONS: The complexity of the water signal reflects the anatomy and physiology of the sub-voxelar environment, and may be a useful source of image contrast. HiSS imaging of brain provides accurate anatomic information, and may improve image contrast and delineation of subtle anatomic features.

Animals↗

Enteroclysis and computed tomography enteroclysis.

Enteroclysis, the most detailed radiologic examination of the small bowel, can be a challenge for both patient and radiologist. This article broadly outlines the principal technical features of the standard enteroclysis procedure and discusses its diagnostic advantages and indications, as well as its limitations and difficulties. A comparative assessment of computed tomography-enteroclysis and the emerging magnetic resonance adaptation complements the survey of current approaches to radiologic small bowel diagnostics.

Barium Sulfate↗

Update on magnetic resonance cholangiopancreatography.

MRCP is a useful tool in the diagnosis of a wide variety of pathologic entities including congenital anomalies, biliary obstruction and stricture, biliary calculi, pancreatitis, neoplasms, and trauma. ERCP and MRCP both have important roles in the management of patients with suspected pancreaticobiliary disease. Knowledge of the advantages and disadvantages of each technique is needed to determine the appropriate work-up of patients with these pathologies.

Biliary Tract Diseases↗

Computerized detection of colonic polyps at CT colonography on the basis of volumetric features: pilot study.

PURPOSE: To develop a computer-aided diagnosis (CAD) scheme for automated detection of colonic polyps on the basis of volumetric features and to assess its accuracy on the basis of colonoscopy, the standard. MATERIALS AND METHODS: Computed tomographic (CT) colonography was performed in patients with use of standard bowel cleansing, air insufflation, and helical scanning in supine and prone positions. The colon was extracted from volumetric data sets generated from transverse CT sections. Volumetric features characterizing polyps were computed at each point in the extracted colon. Polyps were detected by means of hysteresis thresholding and fuzzy clustering followed by a rule-based test on the basis of feature values. Locations of the detected polyps were compared with those detected at conventional colonoscopy. RESULTS: Forty-one cases were analyzed: nine cases with polyps and 32 without polyps. Each case with polyps had one polyp of clinically important size (six were 5-9 mm; three, 10 mm). Thus, there were 82 volumetric data sets, 18 included polyps. Eighty-nine percent (16 of 18) of the polyps were detected. Each of the two false-negative findings was detected in the other position; thus, 100% of polyp cases were detected, with 2.5 false-positive findings per patient. The false-positive findings were similar to those due to common perceptual errors. Most of the false-positive findings were easily distinguishable from true polyps by experienced radiologists. CONCLUSION: The CAD scheme has the potential to depict polyps with high sensitivity and an acceptable false-positive rate.

Adult↗

Automated knowledge-guided segmentation of colonic walls for computerized detection of polyps in CT colonography.

PURPOSE: We have developed a novel automated technique for segmenting colonic walls for the application of computer-aided polyp detection in CT colonography. In particular, the technique was designed to minimize the presence of extracolonic components, such as small bowel, in the segmented colon. METHODS: The segmentation technique combines an improved version of our previously reported anatomy-oriented colon segmentation technique with a colon-based analysis step that performs self-adjusting volume-growing within the colonic lumen. Extracolonic components are eliminated by intersecting of the resulting two segmentations, so that the colonic walls remain in the intersection. The technique was evaluated on 88 CT colonography datasets. The colon segmentations were evaluated subjectively by four radiologists, as well as objectively by performance of an automated polyp detection on the segmentation. For comparison, the tests were also performed for the anatomy-oriented colon segmentation technique. RESULTS: On average, the technique covered 98% of the visible colonic walls. Approximately 50% of the extracolonic components remaining in the anatomy-oriented segmentation were removed, but 10-15% of the segmentation still contained extracolonic components. The dataset-based false-positive rate of the automated polyp detection was improved by 10% without compromising the 100% case-based sensitivity, and the case-based false-positive rate was improved by 15% over the previous false-positive rate. CONCLUSIONS: The technique segments practically all of the colonic walls in the region of diagnostic quality with a large reduction in the amount of extracolonic components over our previously used technique. The new segmentation improves the specificity of our computer-aided polyp detection scheme significantly without any degradation in detection sensitivity.

Artificial Intelligence↗

Computer-aided diagnosis scheme for detection of polyps at CT colonography.

Colon cancer is one of the leading causes of cancer deaths in the United States. However, most colon cancers can be prevented if precursor colonic polyps are detected and removed. An advanced computer-aided diagnosis (CAD) scheme was developed for the automated detection of polyps at computed tomographic (CT) colonography. A region encompassing the colonic wall is extracted from an isotropic volume data set obtained by interpolating CT colonographic scans along the axial direction. Polyp candidates are detected with computation of three-dimensional (3D) geometric features that characterize polyps, followed by extraction of polyps with hysteresis thresholding and fuzzy clustering using these geometric features. The number of false-positive findings is reduced by extracting 3D texture features from polyp candidates and applying quadratic discriminant analysis to the candidates. This CAD scheme was applied in 71 patients who underwent CT colonography, 14 of whom had colonoscopically confirmed polyps (n = 21). At by-patient analysis, sensitivity was 100%, with an average false-positive rate of 2.0 per patient. At by-polyp analysis, the scheme detected 90% of the polyps at the same false-positive rate. This CAD scheme permits accurate detection of suspicious lesions and thus has the potential to reduce radiologists' interpretation time and improve their diagnostic accuracy in the detection of polyps at CT colonography.

Adult↗