PubMed Health⌕ Search

Biomedical subjects

Peter Marsh

Publications and source records attributed to Peter Marsh.

6 recordsLinked to original sources

Evaluation of BacLite Rapid MRSA, a rapid culture based screening test for the detection of ciprofloxacin and methicillin resistant S. aureus (MRSA) from screening swabs.

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a major nosocomial pathogen worldwide. The need for accurate and rapid screening methods to detect MRSA carriers has been clearly established. The performance of a novel assay, BacLite Rapid MRSA (Acolyte Biomedica, UK) for the rapid detection (5 h) and identification of hospital associated ciprofloxacin resistant strains of MRSA directly from nasal swab specimens was compared to that obtained by culture on Mannitol salt agar containing Oxacillin (MSAO) after 48 h incubation. RESULTS: A total of 1382 nasal screening swabs were tested by multiple operators. The BacLite Rapid MRSA test detected 142 out of the 157 confirmed MRSA that were detected on MSAO giving a diagnostic sensitivity of 90.4, diagnostic specificity of 95.7% and a negative predictive value of 98.7%. Of the 15 false negatives obtained by the BacLite Rapid MRSA test, seven grew small amounts (< 10 colonies of MRSA) on the MSAO culture plate and five isolates were ciprofloxacin sensitive. However there were 13 confirmed BacLite MRSA positive samples, which were negative by the direct culture method, probably due to overgrowth on the MSAO plate. There were 53 false positive results obtained by the BacLite Rapid MRSA test at 5 h and 115 cases where MRSA colonies were tentatively identified on the MSAO plate when read at 48 h, and which subsequently proved not to be MRSA. CONCLUSION: The BacLite MRSA test is easy to use and provides a similar level of sensitivity to conventional culture for the detection of nasal carriage of MRSA with the advantage that the results are obtained much more rapidly.

Anti-Bacterial Agents↗

Molecular diagnostics: future probe-based strategies.

Nucleic acid amplification technologies (NAATs) represent powerful tools in clinical microbiology, particularly in areas where traditional culture-based methods alone prove insufficient. A notable advantage is in reducing the time from taking samples to reporting results. This, and the specificity and sensitivity imparted by NAATs, can help to improve patient care. Both thermal and isothermal NAATs have been adapted to aid diagnosis in clinical laboratories. Current molecular diagnostic assays are generally high-tech, and are expensive to buy and perform. Easy-to-use NAATs are beginning to appear, not only facilitating acceptable throughput in clinical laboratories, but also allowing tests to move out of the laboratory, closer to the point of care. Demand for simpler, miniaturized equipment and assays, and the trend toward personalized medicine, is leading towards the development of fully integrated automation and home-use kits. The integration of diverse disciplines, such as genomics, molecular biology, microelectromechanical systems, microfluidics, microfabrication, and organic chemistry, is behind the emerging DNA microarray technology. Development of DNA microchips allows the simultaneous detection of potentially thousands of target sequences, not only favoring high throughput, but also the potential for genotyping patient subsets with respect to their response to particular drug types (pharmakogenomics). It is envisaged that the future of probe-based technologies will see the development of fully integrated assays and devices suitable for nonskilled users.

Base Sequence↗

Evaluation of an isothermal signal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus from patient-screening swabs.

A new molecular assay (CytAMP) utilizing isothermal signal-mediated amplification of RNA was evaluated for rapid detection of methicillin (oxacillin)-resistant Staphylococcus aureus (MRSA). The assay targeted the coa (coagulase) and mecA genes, thereby simultaneously identifying S. aureus and methicillin (oxacillin) resistance. Results were obtained in approximately 3.5 h as a color signal in 96-well microtiter plates. The detection limit was between 2 x 10(5) and 10(6) CFU/assay, equivalent to 4 x 10(6) to 2 x 10(7) CFU/ml in an overnight broth. This level of growth was obtained with an initial inoculum of 10 to 50 CFU. The CytAMP assay and a mecA-femB PCR assay both detected 113 MRSA strains among 396 clinical isolates of bacteria (CytAMP sensitivity and specificity were both 100% relative to those of PCR). Conventional culture detected 109 MRSA strains, but with 19 false-positive and 23 false-negative results relative to both molecular methods. Discrepancies were also observed for 100 enrichment broths containing MRSA screening swabs, with 11 broths culture negative but PCR positive. CytAMP and PCR were more in agreement, but six broths were CytAMP negative and PCR positive. Five of these contained 10(2) to 10(5) CFU/assay (below the CytAMP detection limit of 2 x 10(5) CFU/assay), and the sixth contained 10(6) CFU/assay. Overall, culture and CytAMP had similar sensitivities and specificities relative to those of PCR, but the CytAMP assay enabled swabs to be analyzed as a batch following overnight incubation in enrichment broth, with results reported before 12 noon the next day.

Bacterial Proteins↗

Bipseudophakia: clinicopathological correlation of a dropped lens.

PURPOSE: To examine postmortem human globes containing an anterior chamber and a posterior chamber intraocular lens (IOL). SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Charleston, South Carolina, USA. METHODS: The globes were sectioned at the equator, and the anterior and posterior segments were macroscopically examined. Gross photographs were taken using the Miyake-Apple posterior photographic technique. Histological sections were cut and stained with hematoxylin and eosin, periodic acid-Schiff, and Masson's trichrome. RESULTS: Histopathological findings included a large Soemmering's ring, a tear in the posterior capsule, 1 haptic of the anterior chamber IOL displaced into the iridectomy, thin and atrophic corneal epithelium, separation of Bowman's layer and stroma by fibrovascular tissue, and atrophy of the retinal ganglion cell layer and nerve fiber layer. CONCLUSION: In cases in which secondary IOL implantation is indicated, removing the dislocated IOL appears to be a reasonable choice.

Aged↗

Scattering Behavior of Restructured Aggregates: A Simulation Study.

Simulations of diffusion-limited cluster-cluster aggregation (DLCA) with no restructuring, full restructuring, and partial restructuring have been performed. The scattering patterns produced from these aggregates have been simulated using the Rayleigh-Gans-Debye approximation. Pure DLCA aggregates produced a scattering pattern with the slope of the fractal region being about -1.8. In contrast, the slope of the fractal region of the scattering pattern for fully restructured aggregates was about -2.1, indicating an increase in fractal dimension. Partial restructuring at large length scales produced an upward turn in the scattering pattern at low qr(o), while at high qr(o) the fractal section of the pure DLCA aggregate was retained. This last result was expected and is consistent with the results and postulations of several other workers. This simulation shows that the type of scattering pattern often obtained from orthokinetic or sheared aggregation can be produced by restructuring of aggregates at large length scales. Copyright 2001 Academic Press.

Journal Article↗