PubMed Health⌕ Search

Biomedical subjects

Peter Niederer

Publications and source records attributed to Peter Niederer.

8 recordsLinked to original sources

The myocardium and its fibrous matrix working in concert as a spatially netted mesh: a critical review of the purported tertiary structure of the ventricular mass.

With the increasing interest now paid to volume reduction surgery, in which the cardiac surgeon is required to resect the ventricular myocardium to an extent unenvisaged in the previous century, it is imperative that we develop as precise knowledge as is possible of the basic structure of the ventricular myocardial mass and its functional correlates. This is the most important in the light of the adoption by some cardiac surgeons of an unvalidated model which hypothesises that the entire myocardial mass can be unravelled to produce one continuous band. It is our opinion that this model, and the phylogenetic and functional correlates derived from it, is incompatible with current concepts of cardiac structure and cardiodynamics. Furthermore, the proponents of the continuous myocardial band have made no effort to demonstrate perceived deficiencies with current concepts, nor have they performed any histological studies to validate their model. Clinical results using modifications of radius reduction surgery based on the concept of the continuous myocardial band show that the procedure essentially becomes ineffective. As we show in this review, if we understand the situation correctly, it was the erstwhile intention of the promoters of the continuous band to elucidate the basic mechanism of diastolic ventricular dilation. Their attempts, however, are doomed to failure, as is any attempt to conceptualise the myocardial mass on the basis of a tertiary structure, because of the underlying three-dimensional netting of the myocardial aggregates and the supporting fibrous tissue to form the myocardial syncytium. Thus, the ventricular myocardium is arranged in the form of a modified blood vessel rather than a skeletal muscle. If an analogy is required with skeletal muscle, then the ventricular myocardium possesses the freedom of motion, and the ability for shaping and conformational self-controlling that is better seen in the tongue. It is part of this ability that contributes to the rapid end-systolic ventricular dilation. Histologic investigations reveal that the fibrous content of the three-dimensional mesh is relatively inhomogeneous through the ventricular walls, particularly when the myocardium is diseased. The regional capacity to control systolic mural thickening, therefore, varies throughout the walls of the ventricular components. The existence of the spatially netted structure of the ventricular mass, therefore, must invalidate any attempt to conceptualise the ventricular myocardium as a tertiary arrangement of individual myocardial bands or tracts.

Dissection↗

Three-dimensional fiber architecture of the nonpregnant human uterus determined ex vivo using magnetic resonance diffusion tensor imaging.

The global muscle and collagen fiber orientation in the human uterus has been analyzed hitherto by various standard microscopic techniques. However, no widely accepted model of the fiber architecture of the myometrium could be acquired. The purpose of the present study was to investigate the uterus by magnetic resonance (MR) diffusion tensor imaging (DTI) in a 3D macroscopic approach. Ex vivo MR DTI measurements were performed on five uteri from nonpregnant patients. The main diffusion directions reflecting the orientation of directional structures in the examined tissues were determined from diffusion-weighted spin-echo measurements. A fiber tracking algorithm was used to extrapolate the fiber architecture. The method was validated against histological slides and indirectly through the analysis of leiomyomas, which exhibit less anisotropy than normal myometrium. Significant anisotropy was found in most regions of all examined nonpregnant human uteri. But only two systems of fibers were found running circularly along the intramural part of the uterine tubes. They merged caudally and built a close fitting envelope of circular layers around the uterine cavity. On the cervix, circular fibers were observed in the outer part as well as mostly longitudinal fibers in the inner part. These results confirm the existence of directional structures in the complex fiber architecture of the human uterus. They also indicate that MR DTI is a beneficial and complementary tool to standard microscopic techniques to determine the intrinsic fiber architecture in human organs.

Adult↗

Three-dimensional architecture of the left ventricular myocardium.

Concepts for ventricular function tend to assume that the majority of the myocardial cells are aligned with their long axes parallel to the epicardial ventricular surface. We aimed to validate the existence of aggregates of myocardial cells orientated with their long axis intruding obliquely between the ventricular epicardial and endocardial surfaces and to quantitate their amount and angulation. To compensate for the changing angle of the long axis of the myocytes relative to the equatorial plane of the ventricles with varying depths within the ventricular walls, the so-called helical angle, we used pairs of cylindrical knives of different diameters to punch semicircular slices from the left ventricular wall of pigs, the slices extending from the epicardium to the endocardium. The slices were pinned flat, fixed in formaldehyde, embedded in paraffin, sectioned, stained with azan or hematoxilin and eosin, and analyzed by a new semiautomatic procedure. We made use of new techniques in informatics to determine the number and angulation of the aggregates of myocardial cells cut in their long axis. The alignment of the myocytes cut longitudinally varied markedly between the epicardium and the endocardium. Populations of myocytes, arranged in strands, diverge by varying angles from the epicardial surface. When paired knives of decreasing diameter were used to cut the slices, the inclination of the diagonal created by the arrays increases, while the lengths of the array of cells cut axially decreases. The visualization of the size, shape, and alignment of the myocytic arrays at any side of the ventricular wall is determined by the radius of the knives used, the range of helical angles subtended by the alignment of the myocytes throughout the thickness of the wall, and their angulation relative to the epicardial surface. Far from the majority of the ventricular myocytes being aligned at angles more or less tangential to the epicardial lining, we found that three-fifths of the myocardial cells had their long axes diverging at angles between 7.5 and 37.5 degrees from an alignment parallel to the epicardium. This arrangement, with the individual myocytes supported by connective tissue, might control the cyclic rearrangement of the myocardial fibers. This could serve as an important control of both ventricular mural thickening and intracavitary shape.

Animals↗

Wobbled splatting--a fast perspective volume rendering method for simulation of x-ray images from CT.

3D/2D registration, the automatic assignment of a global rigid-body transformation matching the coordinate systems of patient and preoperative volume scan using projection images, is an important topic in image-guided therapy and radiation oncology. A crucial part of most 3D/2D registration algorithms is the fast computation of digitally rendered radiographs (DRRs) to be compared iteratively to radiographs or portal images. Since registration is an iterative process, fast generation of DRRs-which are perspective summed voxel renderings-is desired. In this note, we present a simple and rapid method for generation of DRRs based on splat rendering. As opposed to conventional splatting, antialiasing of the resulting images is not achieved by means of computing a discrete point spread function (a so-called footprint), but by stochastic distortion of either the voxel positions in the volume scan or by the simulation of a focal spot of the x-ray tube with non-zero diameter. Our method generates slightly blurred DRRs suitable for registration purposes at framerates of approximately 10 Hz when rendering volume images with a size of 30 MB.

Algorithms↗

Noninvasive measurement of regional cerebral blood flow and regional cerebral blood volume by near-infrared spectroscopy and indocyanine green dye dilution.

To find a suitable method for measuring regional cerebral blood flow (rCBF) rapidly at the bedside is still a matter of investigation. The purpose here was to develop a noninvasive method for bedside rCBF measurement and to validate it with a standard method such as perfusion-weighted magnetic resonance imaging (MRI). In 11 healthy volunteers 44 measurements with near-infrared spectroscopy (NIRS) and perfusion-weighted MRI without and with a mean continuous positive airway pressure (CPAP) of 10 mbar were carried out. Four (NIRS) optodes were placed bilaterally on the forehead and 25 mg indocyanine green (ICG) was injected. New algorithms were developed to calculate rCBFNIRS and rCBVNIRS. In 6 volunteers data analysis was successful. No complications associated with the method were observed. During CPAP breathing rCBFNIRS decreased from 18.5 + 6.9 16.1 + 6.2 ml/100 g/min (P = 0.034). Mean values for rCBFMRI decreased from 256 +/- 90 to 216 +/- 62 ml/100 g/min (P = 0.012). Bland and Altman plots showed that the differences did not vary in any systematic way over the range of rCBF or rCBV values assessed and 100% of differences were within the interval mean +/- 2 SD of differences. Limits of agreement (mean +/- 2 SD) were +/- 76.4 ml/100 g/min for rCBF and +/- 15.6 ml/100 g for rCBV. The NIRS ICG dye dilution technique is a promising method for serial noninvasive bedside CBF measurements. The preliminary data indicate that measurements are in agreement with values obtained by perfusion-weighted MRI.

Adult↗

Evaluation of brain toxicity following near infrared light exposure after indocyanine green dye injection.

Indocyanine green (ICG) has excellent safety records and is widely used in medical diagnosis. Recently, a new method has been developed to estimate cerebral blood flow (CBF) using ICG in combination with near-infrared spectroscopy (NIRS). The new technique may be of wide clinical interest, as it is noninvasive and easy to perform at the bedside in stroke patients. Additionally, ICG with the use of specific wavelength lasers is documented to be effective in photodynamic therapy (PDT). Under normal conditions ICG does not cross the intact blood brain barrier (BBB). However, in patients with brain injuries where the BBB may be disturbed, ICG could accumulate in brain parenchyma and in combination with NIR-light exposure, phototoxicity could occur. The aim of the present study was to examine the possible toxicity of ICG in combination with NIRS in a specific setting for CBF measurements. In five rats with mannitol induced BBB breakdown no traces of ICG were found during spectrophotometric analysis of the brain cell suspensions. In ten rats with disrupted BBB there were no significant increases of brain temperature or histological signs of brain damage following 1 h NIR-light exposure after ICG injection. The existing literature concerning the application of ICG in combination with NIR light is reviewed.

Animals↗

Development of preparation methods for and insights obtained from atomic force microscopy of fluid spaces in cortical bone.

Several preparation methods were developed to investigate the dimensions and surface structure of fluid spaces within cortical bone, using atomic force microscopy (AFM). Of special interest was the morphology of the lacunocanalicular system, which serves as a conduit between osteocytes encased in bone tissue, the intramedullary cavity, blood vessels running through the bone, and the periosteal surface of bone. Fracture and the removal of either the mineral or the organic component is a method by which each component can be investigated at a very high resolution in situ. Although fractured bone was too rough to image details of the lacunocanalicular system, post-treatment with ethylene diamine tetraacetic acid (EDTA) or papain allowed for investigation of the collagen matrix or the mineral crystals of bone, respectively. Cut and polished bone was smooth enough for identifying the lacunae of bone using AFM, but unambiguous differentiation between the canaliculi and cracks in the bone surface was not possible. However, when the lacunocanalicular system was filled with polymethylmethacrylate (PMMA), it was possible to image casts of the lacunocanalicular system by selectively etching away the surrounding bone matrix. Using this method, we identified individual canaliculi and measured their dimensions. Furthermore, by carefully etching away the bone matrix in successive etches, it was shown that the wall structure of the canaliculus is dominated by collagen fibrils. These observations have important implications for fluid flow in bone.

Animals↗

Toward a miniaturized fundus camera.

Retinopathy of prematurity (ROP) describes a pathological development of the retina in prematurely born children. In order to prevent severe permanent damage to the eye and enable timely treatment, the fundus of the eye in such children has to be examined according to established procedures. For these examinations, our miniaturized fundus camera is intended to allow the acquisition of wide-angle digital pictures of the fundus for on-line or off-line diagnosis and documentation. We designed two prototypes of a miniaturized fundus camera, one with graded refractive index (GRIN)-based optics, the other with conventional optics. Two different modes of illumination were compared: transscleral and transpupillary. In both systems, the size and weight of the camera were minimized. The prototypes were tested on young rabbits. The experiments led to the conclusion that the combination of conventional optics with transpupillary illumination yields the best results in terms of overall image quality.

Animals↗