Distribution of wall shear rate throughout the arterial tree: a case study.

The generally accepted assumption that the arterial system remodels itself to maintain constant wall shear stress throughout is based on Murray's law, utilising the principle of minimum work for steady flow. However, blood flow in the human arterial system is pulsatile. In this work we outline a method allowing for estimation of wall shear rate in arteries using the flow waveforms as the input signal and estimate wall shear rates in the common carotid, brachial, and femoral arteries to determine the uniformity of distribution of wall shear rates throughout the arterial system. Time-dependent wall shear rates occurring in fully developed pulsatile flow were obtained using Womersley's theory. Flow waveforms and radii of the arteries measured in a young healthy male subject without any known cardiac disease using magnetic resonance taken from the literature were used as the input to the model. Peak/mean wall shear rates were found to be (1640/403.2 s(-1)) in common carotid, (908.8/84.95 s(-1)) in brachial, and (1251/134.2 s(-1)) in femoral arteries. Our findings suggest a non-uniform distribution of wall shear rates throughout the arterial system. The advantage of using this method is that such input data are being routinely recorded during diagnostic ultrasonography.

Arteries↗

B-mode compound imaging in mice.

Cross-sectional B-mode images were obtained from a dead mouse for a 360 degrees scan around the mouse using a 12-MHz linear array. For each cross-section, a set of aligned images was obtained after rotation about the isocenter, which were added to produce a single compound image. The compound images demonstrated a substantial improvement over single B-mode images, with uniform image quality, low noise and improved visualization of structures. This technique may be of interest in forming the basis for a new 3-D in vivo technique in the abdomen and pelvic regions, providing high-quality ultrasound images that are not dependent on operator skill. A further development worth pursuing for improved spatial resolution is reconstruction-based tomography.

Animals↗

Acoustic speed and attenuation coefficient in sheep aorta measured at 5-9 MHz.

B-mode ultrasound (US) images from blood vessels in vivo differ significantly from vascular flow phantom images. Phantoms with acoustic properties more closely matched to those of in vivo arteries may give better images. A method was developed for measuring the speed and attenuation coefficient of US over the range 5 to 9 MHz in samples of sheep aorta using a pulse-echo technique. The times-of-flight method was used with envelope functions to identify the reference points. The method was tested with samples of tissue-mimicking material of known acoustic properties. The tissue samples were stored in Krebs physiologic buffer solution and measured over a range of temperatures. At 37 degrees C, the acoustic speed and attenuation coefficient as a function of frequency in MHz were 1600 +/- 50 ms(-1) and 1.5 +/- 4f(0.94 +/- 1.3) dB cm(-1), respectively.

Acoustics↗

Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging.

Tissue harmonic imaging (THI) has been reported to improve contrast resolution, tissue differentiation and overall image quality in clinical examinations. However, a study carried out previously by the authors (Brown et al. 2004) found improvements only in spatial resolution and not in contrast resolution or anechoic target detection. This result may have been due to the homogeneity of the phantom. Biologic tissues are generally inhomogeneous and THI has been reported to improve image quality in the presence of large amounts of subcutaneous fat. The aims of the study were to simulate the distortion caused by subcutaneous fat to image quality and thus investigate further the improvements reported in anechoic target detection and contrast resolution performance with THI compared with 2D conventional imaging. In addition, the effect of three different types of fat-mimicking layer on image quality was examined. The abdominal transducer of two ultrasound scanners with 2D conventional imaging and THI were tested, the 4C1 (Aspen-Acuson, Siemens Co., CA, USA) and the C5-2 (ATL HDI 5000, ATL/Philips, Amsterdam, The Netherlands). An ex vivo subcutaneous pig fat layer was used to replicate beam distortion and phase aberration seen clinically in the presence of subcutaneous fat. Three different types of fat-mimicking layers (olive oil, lard and lard with fish oil capsules) were evaluated. The subcutaneous pig fat layer demonstrated an improvement in anechoic target detection with THI compared with 2D conventional imaging, but no improvement was demonstrated in contrast resolution performance; a similar result was found in a previous study conducted by this research group (Brown et al. 2004) while using this tissue-mimicking phantom without a fat layer. Similarly, while using the layers of olive oil, lard and lard with fish oil capsules, improvements due to THI were found in anechoic target detection but, again, no improvements were found for contrast resolution for any of the layer combinations. Therefore, it was felt that the lack of improvement in contrast resolution performance may be due to the test phantom design and not to whether a layer was present that caused beam distortion and phase aberrations.

Acoustics↗

Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners.

The ability to detect flow is the most crucial aspect of an ultrasound (US) system because, if flow cannot be detected, no other aspect of performance matters. The objectives of this study were to validate a Doppler "sensitivity performance index," a figure of merit, and to determine if it could be used to differentiate colour Doppler sensitivity performance in scanners of varying complexity. The sensitivity performance index was developed to give a combined measure of related aspects of sensitivity, such as the lowest detectable velocity, the vessel size and the penetration depth. The colour Doppler sensitivity was evaluated objectively as the lowest detectable velocity signal from the deepest achievable point within the Doppler sensitivity phantom free from extraneous noise in a small diameter vessel (3.2 mm inner diameter). The effect of vessel size and mean velocity on the sensitivity performance index were investigated and it was found that the index was not proportional to vessel size, but this may be accounted for by considering the effect of the acoustic properties of the vessel material, the clutter filter and beam shape. The results obtained using flow phantoms with vessel sizes different from those used in this study are, therefore, not directly comparable to the results found in this study; however, a similar trend should be found in the results for the effect of control settings and a similar range of US scanners. It was found that the Doppler sensitivity performance index was a robust challenging test because none of the US scanners evaluated was capable of achieving the highest sensitivity performance index score, which would be limited by the lowest pump velocity and the deepest point of the vessel within the flow phantom. Therefore, this suggests that this method of determining Doppler sensitivity performance is valuable in the absence of other suitable methods, despite the fact that the relationship between the sensitivity performance index and vessel size is not proportional. Furthermore, use of the Doppler sensitivity performance index for the evaluation of a range of scanners demonstrated that curvilinear transducers have higher sensitivity performance indices than higher-frequency linear transducers, due to the higher achievable penetration depth. The effect of instrument settings was assessed for two transducers, the 4C3 curvilinear general-purpose transducer (Aspen) and the PVM375AT curvilinear general-purpose transducer (Nemio). The colour Doppler sensitivity performance was found to be significantly dependent on the clutter filter setting and the output power setting for both transducers tested. Users need to be aware of the effect of these settings on the colour Doppler sensitivity performance of their US scanner when interpreting the clinical significance of the colour Doppler information.

Blood Flow Velocity↗

Doppler colour flow imaging and flow quantification with a novel forward-viewing intravascular ultrasound system.

The aim of this work was to investigate the potential of a novel forward-viewing intravascular ultrasound (IVUS) system for flow quantification and colour flow imaging combined with B-mode imaging. A stiff 3.8-mm diameter catheter was used to scan a 72 degrees sector ahead of its tip. Operating at 30 MHz, the catheter was integrated with an IVUS scanner and a radiofrequency (RF) data-acquisition system. RF data were software processed for producing B-mode images and deriving velocity estimates. Steady flow in the range of 45 to 146 mL/min toward the catheter, was used in wall-less tissue-mimicking phantoms simulating healthy lumen (8-mm diameter), 30% diameter symmetrical stenosis and 37% diameter eccentric stenosis. The system provided colour flow images and good estimation of peak velocity and volumetric flows (within 1% to 9% and 16% to 48%, respectively, of calculated values) at 5 to 7 mm distal to the catheter. A sector forward-viewing IVUS imaging/Doppler system is suitable for combined anatomical and functional assessment of stenosed vessels.

Blood Flow Velocity↗

Angle-independent estimation of maximum velocity through stenoses using vector Doppler ultrasound.

Categorisation for arterial stenoses treatment is determined primarily by the degree of occlusion, which is often estimated ultrasonically from blood velocity measurements. In current single-beam ultrasound (US) systems, this estimate can suffer from gross errors due to angle-dependence. The purpose of this study was to find out if an experimental dual-beam US system could reduce the angle-dependence of the velocity estimates. We compared four dual-beam velocity estimation algorithms on both a string phantom and straight tube wall-less flow phantoms incorporating symmetrical and asymmetrical stenoses from 0% to 91% by area. The estimated maximum velocity varied, on average, by 7.6% for beam-vessel angles from 40 degrees to 80 degrees. The fluctuation in the magnitude estimate was reduced by a factor of 2.6 using a hybrid single-dual-beam algorithm. We conclude that, when the true velocity lies in the scan plane, the dual-beam system reduces the angle-dependence and, thus, has the potential to improve categorisation of patients with arterial stenoses.

Algorithms↗

The relationship between aortic wall distensibility and rupture of infrarenal abdominal aortic aneurysm.

OBJECTIVE: A more accurate means of prediction of abdominal aortic aneurysm (AAA) rupture would improve the clinical and cost effectiveness of prophylactic repair. The purpose of this study was to determine whether AAA wall distensibility can be used to predict time to rupture independently of other recognized risk factors. METHODS: A prospective, six-center study of 210 patients with AAA in whom blood pressure (BP), maximum AAA diameter (Dmax), and AAA distensibility (pressure strain elastic modulus [Ep] and stiffness [beta]) were measured at 6 months with an ultrasound scan-based echo-tracking technique. A stepwise, time-dependent, Cox proportional hazards model was used to determine the effect on time to rupture of age, gender, BP, Dmax, BP, Ep, beta, and change in Dmax, Ep, and beta adjusted for time between follow-up visits. RESULTS: Median (interquartile range) AAA diameter was 48 mm (41 to 54 mm), median age was 72 years (68 to 77 years), and median follow-up period was 19 months (9 to 30 months). In the Cox model, female gender (hazards ratio [HR], 2.78; 95% CI, 1.23 to 6.28; P =.014), larger Dmax (HR, 1.36 for 10% increase in Dmax; 95% CI, 1.12 to 1.66; P =.002), higher diastolic BP (HR, 1.13 for 10% increase in BP; 95% CI, 1.13 to 1.92; P =.004), and a decrease in Ep (increase in distensibility) over time (HR, 1.38 for 10% decrease in Ep over 6 months; 95% CI, 1.08 to 1.78; P =.010) significantly reduced the time to rupture (had a shorter time to rupture). CONCLUSION: Women have a shorter time to AAA rupture. The measurement of AAA distensibility, diastolic BP, and diameter may provide a more accurate assessment of rupture risk than diameter alone.

Aged↗

Velocity fluctuation reduction in vector Doppler ultrasound using a hybrid single/dual-beam algorithm.

In order to reduce the fluctuations in the velocity magnitude estimate, we propose a modification to the standard algorithm for reconstructing the (two component) vector velocity from the measured Doppler shifts in two directions. This uses the standard dual-beam algorithm, combined with temporal smoothing, to find only the velocity angle, then uses the single-beam algorithm to estimate the velocity magnitude. We present initial data showing the significant reduction in velocity estimate fluctuation that this hybrid method achieves compared to the standard algorithm.

Algorithms↗