PubMed Health⌕ Search

Biomedical subjects

Peter Remeijer

Publications and source records attributed to Peter Remeijer.

11 recordsLinked to original sources

Tumor motion and deformation during external radiotherapy of bladder cancer.

PURPOSE: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. METHODS AND MATERIALS: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. RESULTS: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to approximately 0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. CONCLUSIONS: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall.

Female↗

Adaptive radiotherapy for invasive bladder cancer: a feasibility study.

PURPOSE: To evaluate the feasibility of adaptive radiotherapy (ART) in combination with a partial bladder irradiation. METHODS AND MATERIALS: Twenty-one patients with solitary T1-T4 N0M0 bladder cancer were treated to the bladder tumor + 2 cm margin planning target volume (PTV(CONV)). During the first treatment week, five daily computed tomography (CT) scans were made immediately before or after treatment. In the second week, a volume was constructed encompassing the gross tumor volumes (GTVs) on the planning scan and the five CT scans (GTV(ART)). The GTV(ART) was expanded with a 1 cm margin for the construction of a PTV(ART). Starting in the third week, patients were treated to PTV(ART). Repeat CT scans were used to evaluate treatment accuracy. RESULTS: On 5 of 91 repeat CT scans (5%), the GTV was not adequately covered by the PTV(ART). On treatment planning, there was only one scan in which the GTV was not adequately covered by the 95% isodose. On average, the treatment volumes were reduced by 40% when comparing PTV(ART) with PTV(CONV) (p < 0.0001). CONCLUSION: The adaptive strategy for bladder cancer is an effective way to deal with treatment errors caused by variations in bladder tumor position and leads to a substantial reduction in treatment volumes.

Feasibility Studies↗

Respiratory correlated cone beam CT.

A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated procedure for CBCT and evaluated its performance. This respiratory correlated CBCT procedure consists of retrospective sorting in projection space, yielding subsets of projections that each corresponds to a certain breathing phase. Subsequently, these subsets are reconstructed into a four-dimensional (4D) CBCT dataset. The breathing signal, required for respiratory correlation, was directly extracted from the 2D projection data, removing the need for an additional respiratory monitor system. Due to the reduced number of projections per phase, the contrast-to-noise ratio in a 4D scan reduced by a factor 2.6-3.7 compared to a 3D scan based on all projections. Projection data of a spherical phantom moving with a 3 and 5 s period with and without simulated breathing irregularities were acquired and reconstructed into 3D and 4D CBCT datasets. The positional deviations of the phantoms center of gravity between 4D CBCT and fluoroscopy were small: 0.13 +/- 0.09 mm for the regular motion and 0.39 +/- 0.24 mm for the irregular motion. Motion artifacts, clearly present in the 3D CBCT datasets, were substantially reduced in the 4D datasets, even in the presence of breathing irregularities, such that the shape of the moving structures could be identified more accurately. Moreover, the 4D CBCT dataset provided information on the 3D trajectory of the moving structures, absent in the 3D data. Considerable breathing irregularities, however, substantially reduces the image quality. Data presented for three different lung cancer patients were in line with the results obtained from the phantom study. In conclusion, we have successfully implemented a respiratory correlated CBCT procedure yielding a 4D dataset. With respiratory correlated CBCT on a linear accelerator, the mean position, trajectory, and shape of a moving tumor can be verified just prior to treatment. Such verification reduces respiration induced geometrical uncertainties, enabling safe delivery of 4D radiotherapy such as gated radiotherapy with small margins.

Algorithms↗

Reproducibility of the bladder shape and bladder shape changes during filling.

The feasibility of high precision radiotherapy to the bladder region is limited by bladder motion and volume changes. In the near future, we plan to begin treatment delivery of bladder cancer patients with the acquisition of a cone beam CT image on which the complete bladder will be semi-automatically localized. Subsequently, a bladder shape model that was developed in a previous study will be used for bladder localization and for the prediction of shape changes in the time interval between acquisition and beam delivery. For such predictions, knowledge about urinary inflow rate is required. Therefore, a series of MR images was acquired over 1 h with time intervals of 10 min for 18 healthy volunteers. To gain insight in the reproducibility of the bladder shape over longer periods of time, two additional MRI series were recorded for 10 of the volunteers. To a good approximation, the bladder volume increased linearly in time for all individuals. Despite receiving drinking instructions, we found a large variation in the inflow rate between individuals, ranging from 2.1 to 15 cc/min (mean value: 9 +/- 3 cc/min). In contrast, the intravolunteer variation was much smaller, with a mean standard deviation (SD) of 0.4 cc/min. The inflow rate was linearly correlated with age (negative slope). To study the reproducibility of the bladder shape, we compared bladder shapes of equal volume. For all individuals, the caudal part of the bladder was the most reproducible (variations<0.3 cm in all cases). The cranial and posterior parts of the bladder was much less reproducible, with local SD values up to approximately 1.2 cm for bladders with a volume of 200 cc. These large long-term variations were primarily caused by changes in position and filling of the small bowel and rectum. However, for short time intervals, the rectal filling was (nearly) constant. Therefore, the reproducibility of urinary inflow, combined with the previously developed shape model gives us an excellent tool to predict short-term shape changes. We intend to use this tool for further improvement of image-guided radiotherapy for bladder cancer patients.

Adult↗

Impact of knee support and shape of tabletop on rectum and prostate position.

PURPOSE: To evaluate the impact of different tabletops with or without a knee support on the position of the rectum, prostate, and bulb of the penis; and to evaluate the effect of these patient-positioning devices on treatment planning. METHODS AND MATERIALS: For 10 male volunteers, five MRI scans were made in four different positions: on a flat tabletop with knee support, on a flat tabletop without knee support, on a rounded tabletop with knee support, and on a rounded tabletop without knee support. The fifth scan was in the same position as the first. With image registration, the position differences of the rectum, prostate, and bulb of the penis were measured at several points in a sagittal plane through the central axis of the prostate. A planning target volume was generated from the delineated prostates with a margin of 10 mm in three dimensions. A three-field treatment plan with a prescribed dose of 78 Gy to the International Commission on Radiation Units and Measurements point was automatically generated from each planning target volume. Dose-volume histograms were calculated for all rectal walls. RESULTS: The shape of the tabletop did not affect the rectum and prostate position. Addition of a knee support shifted the anterior and posterior rectal walls dorsally. For the anterior rectal wall, the maximum dorsal shift was 9.9 mm (standard error of the mean [SEM] 1.7 mm) at the top of the prostate. For the posterior rectal wall, the maximum dorsal shift was 10.2 mm (SEM 1.5 mm) at the middle of the prostate. Therefore, the rectal filling was pushed caudally when a knee support was added. The knee support caused a rotation of the prostate around the left-right axis at the apex (i.e., a dorsal rotation) by 5.6 degrees (SEM 0.8 degrees ) and shifts in the caudal and dorsal directions of 2.6 mm (SEM 0.4 cm) and 1.4 mm (SEM 0.6 mm), respectively. The position of the bulb of the penis was not influenced by the use of a knee support or rounded tabletop. The volume of the rectal wall receiving the same dose range (e.g., 40-75 Gy) was reduced by 3.5% (SEM 0.9%) when a knee support was added. No significant differences were observed between the first and fifth scan (flat tabletop with knee support) for all measured points, thereby excluding time trends. CONCLUSIONS: The rectum and prostate were significantly shifted dorsally by the use of a knee support. The rectum shifted more than the prostate, resulting in a dose benefit compared with irradiation without knee support. The shape of the tabletop did not influence the rectum or prostate position.

Equipment Design↗

A model to predict bladder shapes from changes in bladder and rectal filling.

The purpose of this study is to develop a model that quantifies in three dimensions changes in bladder shape due to changes in bladder and/or rectal volume. The new technique enables us to predict changes in bladder shape over a short period of time, based on known urinary inflow. Shortly prior to the treatment, the patient will be scanned using a cone beam CT scanner (x-ray volume imager) that is integrated with the linear accelerator. After (automated) delineation of the bladder, the model will be used to predict the short-term shape changes of the bladder for the time interval between image acquisition and dose delivery. The model was developed using multiple daily CT scans of the pelvic area of 19 patients. For each patient, the rigid bony structure in follow-up scans was matched to that of the planning CT scan, and the outer bladder and rectal wall were delineated. Each bladder wall was subdivided in 2500 domains. A fixed reference point inside the bladder was used to calculate for each bladder structure a "Mercator-like" 2D scalar map (similar to a height map of the globe), containing the distances from this reference point to each domain on the bladder wall. Subsequently, for all bladder shapes of a patient and for all domains on the wall individually, the distance to the reference point was fitted by a linear function of both bladder and rectal volume. The model uses an existing bladder structure to create a new structure via expansion (or contraction), until the expressed volume is reached. To evaluate the predictive power of the model, the jack-knife method was used. The errors in the fitting procedure depended on the part of the bladder and range from 0 to 0.5 cm (0.2 cm on average). It was found that a volume increase of 150 cc can lead to a displacement up to about 2.5 cm of the cranial part of the bladder. With the model, the uncertainty in the position of the bladder wall can be reduced down to a maximum value of about 0.5 cm in case the bladder volume increase is known. Furthermore, it was found that a change in rectal filling causes a shift of the bladder, while its shape is hardly influenced. In conclusion, we developed a model that describes the bladder shape and position as a function of the bladder volume and the rectal filling. The model accurately describes the complex shape of the bladder as it works on each domain of the bladder separately.

Biophysical Phenomena↗

Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer.

PURPOSE: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). METHODS AND MATERIALS: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients. RESULTS: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 mm, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course. CONCLUSION: Anisotropic margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation.

Aged↗

The theoretical benefit of beam fringe compensation and field size reduction for iso-normal tissue complication probability dose escalation in radiotherapy of lung cancer.

To assess the benefit of beam fringe (50%-90% dose level) sharpening for lung tumors, we performed a numerical simulation in which all geometrical errors (breathing motion, random and systematic errors) are included. A 50 mm diameter lung tumor, located centrally in a lung-equivalent phantom was modeled. Treatment plans were designed with varying number and direction of beams, both with and without the use of intensity modulation to sharpen the beam fringe. Field size and prescribed dose were varied under the constraint of a constant mean lung dose of 20 Gy, which yields a predicted complication probability of about 10%. After numerical simulation of the effect of setup errors and breathing, the resulting dose distribution was evaluated using the minimum dose and the equivalent uniform dose (EUD) in the moving clinical target volume (CTV). When the dose in the CTV was constrained between 95% and 107% of the prescribed dose, the maximum attainable EUD was 71 Gy for a four-field noncoplanar technique with simple conformal beams. When penumbra sharpening was applied using a single beam segment at the edge of the open field, this EUD could be raised to 87 Gy. For a hypothetical infinitely steep penumbra, further escalation to an EUD of 104 Gy was possible. When the dose in the CTV was not constrained, a large escalation of the EUD was possible compared to the constrained case. In this case, the maximum attainable EUD for open fields was 115 Gy, using the four-field noncoplanar technique. The benefit of penumbra sharpening was only modest, with no increase of the EUD for the single-segment technique and a small increase to 125 Gy for the infinitely steep penumbra. From these results we conclude that beam fringe sharpening in combination with field-size reduction leads to a large increase in EUD when a homogeneous target dose is pursued. Further escalation of the EUD is possible when the homogeneity constrained is relaxed, but the relative benefit of beam-fringe sharpening then decreases.

Artifacts↗

Margins for translational and rotational uncertainties: a probability-based approach.

PURPOSE: To define margins for systematic rotations and translations, based on known statistical distributions of these deviations. METHODS AND MATERIALS: The confidence interval-based expansion method for translations, known as the "rolling ball algorithm," was extended to include rotations. This new method, which we call the Rotational and Translational Confidence Limit (RTCL) method, is exact for a point with arbitrary rotations and translations or for a finite shape with rotations only. The method was compared with two existing expansion methods: a rolling ball algorithm without rotations, and a convolution (blurring) method which included rotations. On the basis of these methods, planning target volumes (PTVs, expanded clinical target volumes [CTVs]) were constructed for a number of shapes (a sphere, a sphere with an extension, and three prostate cases), and evaluated in several ways by means of a Monte Carlo method. The accuracy of each method was measured by determining the probability of finding the CTV completely inside the PTV (P(CTVinPTV)), using parameters that yield a 90% probability for a sphere-shaped CTV without rotations. Furthermore, with the expansion parameters adjusted to give an equal P(CTVinPTV) for all methods, PTV volumes were compared. RESULTS: With the expansion algorithm parameters chosen to yield P(CTVinPTV) = 90% for a sphere, an average P(CTVinPTV) of 84%, 57%, and 46% was obtained for the other shapes, using the RTCL method, coverage probability, and rolling ball, respectively. With the parameters adjusted to yield an equal P(CTVinPTV) for all methods, the PTV volume was on average 8% larger for the coverage probability method and 15% larger for the rolling ball algorithm compared to the RTCL method. CONCLUSION: The RTCL method provides an accurate way to include the effects of systematic rotations in the margin. Compared to other algorithms, the method is less sensitive to the shape of the CTV, and, given a fixed probability of finding the CTV inside the PTV, a smaller PTV volume can be obtained.

Algorithms↗

Inclusion of geometric uncertainties in treatment plan evaluation.

PURPOSE: To correctly evaluate realistic treatment plans in terms of absorbed dose to the clinical target volume (CTV), equivalent uniform dose (EUD), and tumor control probability (TCP) in the presence of execution (random) and preparation (systematic) geometric errors. MATERIALS AND METHODS: The dose matrix is blurred with all execution errors to estimate the total dose distribution of all fractions. To include preparation errors, the CTV is randomly displaced (and optionally rotated) many times with respect to its planned position while computing the dose, EUD, and TCP for the CTV using the blurred dose matrix. Probability distributions of these parameters are computed by combining the results with the probability of each particular preparation error. We verified the method by comparing it with an analytic solution. Next, idealized and realistic prostate plans were tested with varying margins and varying execution and preparation error levels. RESULTS: Probability levels for the minimum dose, computed with the new method, are within 1% of the analytic solution. The impact of rotations depends strongly on the CTV shape. A margin of 10 mm between the CTV and planning target volume is adequate for three-field prostate treatments given the accuracy level in our department; i.e., the TCP in a population of patients, TCP(pop), is reduced by less than 1% due to geometric errors. When reducing the margin to 6 mm, the dose must be increased from 80 to 87 Gy to maintain the same TCP(pop). Only in regions with a high-dose gradient does such a margin reduction lead to a decrease in normal tissue dose for the same TCP(pop). Based on a rough correspondence of 84% minimum dose with 98% EUD, a margin recipe was defined. To give 90% of patients at least 98% EUD, the planning target volume margin must be approximately 2.5 Sigma + 0.7 sigma - 3 mm, where Sigma and sigma are the combined standard deviations of the preparation and execution errors. This recipe corresponds accurately with 1% TCP(pop) loss for prostate plans with clinically reasonable values of Sigma and sigma. CONCLUSION: The new method computes in a few minutes the influence of geometric errors on the statistics of target dose and TCP(pop) in clinical treatment plans. Too small margins lead to a significant loss of TCP(pop) that is difficult to compensate for by dose escalation.

Algorithms↗

Irradiation of paranasal sinus tumors, a delineation and dose comparison study.

PURPOSE: To determine the influence of observer variation and treatment planner variation on the dose delivered to the target and normal structures when irradiating paranasal sinus carcinomas. PATIENTS AND METHODS: Nine patients with paranasal sinus tumors underwent debulking surgery and subsequent radiation therapy. Two observers from two different institutions delineated the clinical target volumes (CTVs) for the elective and the boost volumes. These volumes were expanded in three dimensions with a 5-mm margin. At both institutions, a three-dimensional conformal treatment plan of 46 Gy to the elective volumes, plus 20 Gy to the boost target volumes, was designed. The delineated volumes and treatment plans were compared. RESULTS: The mean volume ratio between institutions of the elective CTVs was 0.9 (standard error = 0.05). The differences were located mainly at the bottom of the nasal cavity and at the frontal border of the target areas. The differences in boost CTVs were large; the mean volume ratio was 2.6 (standard error = 0.58). After expansion of the CTV, the mean distance between the planning target volume (PTV) and the chiasm differed by 0.5 cm between the two institutions. Cases with smaller distances between the PTV and the chiasm had more underdosage to the PTV. This effect was less pronounced for institution A (1 vol.%/cm) than for institution B (10 vol.%/cm) treatment plans, which were less conformal. When the treatment plan was designed for the PTV of institution B, 23 volume % of the PTV of institution A received <95% of the prescribed dose. If the treatment plan was designed for the (on average larger) PTV of institution A, the underdosed volume of PTV at institution B was 17%. The relative underdosage to the "other" PTV was larger when the original treatment plan was more conformal. CONCLUSION: In the irradiation of paranasal sinus cancer, both the treatment planner and the observer have a significant influence on the dose to the target and organs at risk. Both effects are similar in magnitude. The observer effect increases with more conformal treatment plans. Minimizing the observer variation is important for adequate irradiation of paranasal sinus cancer.

Carcinoma, Adenoid Cystic↗