PubMed Health⌕ Search

Biomedical subjects

Peter Spégel

Publications and source records attributed to Peter Spégel.

8 recordsLinked to original sources

Nanoparticle-based continuous full filling capillary electrochromatography/electrospray ionization-mass spectrometry for separation of neutral compounds.

Highly efficient reversed-phase capillary electrochromatography (CEC) separations (plate numbers up to 700 000/m), with electrospray ionization mass spectrometry detection were achieved utilizing novel dextran-coated polymer nanoparticles as a pseudostationary phase. A continuous full filling (CFF) technique in which nanoparticles are continuously introduced into the capillary was employed for separation of neutral analytes (dialkyl phthalates), utilizing an orthogonal electrospray interface to prevent nanoparticles from entering the mass spectrometer. CFF-CEC benefits from that an entirely fresh column is employed for every analysis, avoiding carryover effects associated with stationary-phase contamination. The highly efficient separations obtained were accomplished by optimizing the organic modifier concentration in the electrolyte and by using a high nanoparticle concentration (5 mg/mL), to improve interparticle mass transfer and gain sufficient retention. Nanoparticles, with an average diameter of 600 nm, were prepared by polymerization of methacrylic acid and trimethylolpropane trimethacrylate, which in turn were coated with dextran. These nanoparticles formed stable suspensions in electrolytes having broad ranges of polarities, enabling straightforward optimization of the reversed-phase conditions.

Capillary Electrochromatography↗

Molecularly imprinted polymer formats for capillary electrochromatography.

The research aimed towards the adaptation of molecularly imprinted polymers (MIPs) to the capillary format and the use of these highly selective matrices for capillary electrochromatography (CEC) is reviewed in this article. The MIP is prepared by incorporation of a template molecule into a polymerization protocol. After polymerization and extraction of the template from the resulting polymer a highly selective material with recognition cavities complementary to the template in size, shape and chemical functionality is obtained. MIPs have been used as recognition elements in several different analytical techniques. In combination with CEC a novel separation system with a unique selectivity towards a predetermined target (the template) is achieved. The merge of molecular imprinting technology (MIT) and CEC have introduced several interesting polymer formats, due to the adaptation of the MIP to the miniaturized capillary format. The polymer formats can be classified according to their preparation protocols and appearance into three conceptually different categories, i.e. the monolith, the coating and the nanoparticles. The preparation protocols, characteristics and applications of these formats will be discussed.

Chromatography, Micellar Electrokinetic Capillary↗

Selectivity toward multiple predetermined targets in nanoparticle capillary electrochromatography.

Two unique methods to achieve selectivity toward multiple predetermined targets employing molecular imprinting technology have been developed. Partial filling capillary electrochromatography (CEC) was utilized to evaluate and compare the two techniques. The first approach, the mixed singly templated molecularly imprinted polymer (MIP) nanoparticle approach, is based on the mixing of two types of MIP nanoparticles with inherently different selectivity. The second approach, the multiply templated MIP nanoparticle approach, is based on the incorporation of two different templates during the preparation of the MIP nanoparticles. The use of MIPs in analytical chemistry applications has been extensively investigated during the past years. However, MIP nanoparticles with tailored multiple selectivity toward predetermined enantiomers has not yet been explored. The relative amounts of the two templates studied, i.e., (S)-ropivacaine and (S)-propranolol, were found to strongly affect the affinity of the multiply templated MIP nanoparticles for the predetermined targets. The amount of (S)-propranolol template had to be decreased to concentrations rarely applied in MIP synthesis in order to achieve 2-fold selectivity. Even though strongly decreased to 10% of the usual concentration employed, the MIP could efficiently separate the enantiomers of propranolol when applied in partial filling CEC. This opens up for new possibilities to decrease the need for an initial high amount of template in order to be able to produce an efficient MIP. The multiple enantiomer separation ability of the multiply templated MIP nanoparticles was compared with that of singly templated MIP nanoparticles that were mixed prior to analysis. It was concluded that the multiply templated MIP potentially can offer many new and interesting applications in chromatography as well as in sensor technology and solid-phase extraction.

Journal Article↗

Molecularly imprinted polymers in capillary electrochromatography: recent developments and future trends.

The developments in molecularly imprinted polymer (MIP)-based capillary electrochromatography (CEC) achieved during the past years are reviewed in this article. The MIP is prepared using a templated polymerization reaction and results in a material with a high selectivity towards a predetermined target. The selectivity of the MIP is comparable to that of the biological antibodies, however, the MIP is much more stable and is thus able to withstand extremely harsh conditions in terms of pH, temperature, and organic solvents. The high selectivity and stability of the MIP made it an interesting candidate for application as stationary phase sorbent in chromatography. However, due to slow kinetics the efficiency of the early MIP columns, which were predominantly applied in high-performance liquid chromatography (HPLC), were limited. The use of CEC was thought to improve the efficiency of the MIP-based separation system. The small dimensions of the capillary format employed in CEC have put demands on the polymer systems which have resulted in the development of many different polymer formats. Thus, this need for novel MIP formats for applications in CEC has contributed a lot to the general development of MIP formats as well as to the knowledge in MIP synthesis and characteristics.

Chromatography, Micellar Electrokinetic Capillary↗

Nanoparticles as pseudostationary phase in capillary electrochromatography/ESI-MS.

A novel technique that uses polymer nanoparticles as pseudostationary phase in capillary electrochromatography with electrospray ionization mass spectrometry detection is described. A continuous full filling technique in which the nanoparticles were suspended in the entire electrolyte volume as well as a conventional partial filling technique is presented. No nanoparticles entered the mass spectrometer, which was fitted with an orthogonal electrospray interface, despite the continuous flow of nanoparticles into the interface. Nanoparticles (average diameter 160 nm) were prepared from methacrylic acid, methyl methacrylate, and trimethylolpropane trimethacrylate by utilizing a precipitation polymerization technique. Salbutamol, nortriptyline, and diphenhydramine were used as analytes. The interaction between analytes and nanoparticles was found to be predominantly ionic.

Journal Article↗