Publications and source records attributed to Peter Speier.

3 recordsLinked to original sources

3D radial projection technique with ultrashort echo times for sodium MRI: clinical applications in human brain and skeletal muscle.

(23)Na MRI has the potential to noninvasively detect sodium (Na) content changes in vivo. The goal of this study was to implement (23)Na MRI in a clinical setting for neurooncological and muscular imaging. Due to the biexponential T(2) decay of the tissue Na signal with a short component, which ranges between 0.5-8 ms, the measurement of total Na content requires imaging techniques with echo times (TEs) below 0.5 ms. A 3D radial pulse sequence with a TE of 0.2 ms at a spatial resolution of 4 x 4 x 4 mm(3) was developed that allows the acquisition and presentation of Na images on the scanner. This sequence was evaluated in patients with low- and high-grade gliomas, and higher (23)Na MR signals corresponding to an increased Na content were found in the tumor regions. The contrast-to-noise ratio (CNR) between tumor and white matter increased from 0.8 +/- 0.2 to 1.3 +/- 0.3 with tumor grade. In patients with an identified muscular (23)Na channelopathy (Paramyotonia congenita (PC)), induced muscle weakness led to a signal increase of approximately 18% in the (23)Na MR images, which was attributed to intracellular Na(+) accumulation in this region.

Adult↗

Active catheter tracking using parallel MRI and real-time image reconstruction.

In this work active MR catheter tracking with automatic slice alignment was combined with an autocalibrated parallel imaging technique. Using an optimized generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 2, we were able to reduce the acquisition time per image by 34%. To accelerate real-time GRAPPA image reconstruction, the coil sensitivities were updated only after slice reorientation. For a 2D trueFISP acquisition (160 x 256 matrix, 80% phase matrix, half Fourier acquisition, TR = 3.7 ms, GRAPPA factor = 2) real-time image reconstruction was achieved with up to six imaging coils. In a single animal experiment the method was used to steer a catheter from the vena cava through the beating heart into the pulmonary vasculature at an image update rate of about five images per second. Under all slice orientations, parallel image reconstruction was accomplished with only minor image artifacts, and the increased temporal resolution provided a sharp delineation of intracardial structures, such as the papillary muscle.

Algorithms↗

Dynamic coil selection for real-time imaging in interventional MRI.

MR-guided intravascular interventions require image update rates of up to 10 images per second, which can be achieved using parallel imaging. However, parallel imaging requires many coil elements, which increases reconstruction times and thus compromises real-time image reconstruction. In this study a dynamic coil selection (DCS) algorithm is presented that selects a subset of receive coils to reduce image reconstruction times. The center-of-sensitivity coordinates and the relative signal intensities are determined for each coil in a prescan. During the intervention m coils are selected for reconstruction using a coil ranking based on the distance to the current slice or catheter position. In a phantom experiment for m = 6, an optimal signal-to-background ratio (SBR) was achieved and foldover artifacts were avoided. In three animal experiments involving catheter manipulation in the aorta and the right heart chamber, the anatomy was successfully visualized at frame rates of about 5 Hz using active catheter tracking.

Algorithms↗