PubMed Health⌕ Search

Biomedical subjects

Peter T A Reilly

Publications and source records attributed to Peter T A Reilly.

5 recordsLinked to original sources

MALDI of individual biomolecule-containing airborne particles in an ion trap mass spectrometer.

Individual airborne biomolecule-containing particles were detected and characterized in near real-time by matrix-assisted laser desorption/ionization (MALDI) with an ion trap mass spectrometer. Biomolecule-containing particles were laboratory-generated and passed through a heated region containing a solution of matrix in equilibrium with the gas phase. Passage into a cooler region created a supersaturation, resulting in rapid deposition of the matrix vapor onto the biomolecule-containing particles, whereupon they were sampled into the inlet of our spectrometer. The coated particles were collimated and individually sized by light-scattering-based time-of-flight. When the sized particle reached the center of the ion trap, it was irradiated with a focused 266-nm laser, and the resulting ions were mass-analyzed. Mass spectra of leucine enkephalin, bradykinin, substance P, and polylysine-containing particles were determined with attomole sensitivity. Structural information of the peptides contained in an individual particle was obtained by tandem mass spectrometry. Analysis of the results yields insights into the aerosol laser ablation ionization process that suggests an optically limited mechanism for ion production that has interesting ramifications on the utility of aerosol-based MALDI as an analytical technique.

Air↗

High-pressure ion trap mass spectrometry.

The effects of buffer gas pressure on ion trap stability, mass resolution/calibration, and choice of mass scanning are described. Pressure effects were treated phenomenologically by adding a drag term to the ion equations of motion. The resulting collisional damping enlarges the mass-dependent stability region but reduces the region in which mass-selective resonance ejection can be performed. The pressure effects can be reduced by increasing the frequency of the alternating quadrupole field.

Journal Article↗

Analysis of volatile organic compounds in air with a micro ion trap mass analyzer.

Analysis of several volatile organic compounds in air has been demonstrated with a micro ion trap mass analyzer equipped with a semipermeable membrane sampling inlet. MS/MS of selected compounds was also shown to be feasible with the miniature ion trap and could be used to improve sensitivity by reducing background noise.

Journal Article↗

Double resonance ejection in a micro ion trap mass spectrometer.

Ion ejection from a cylindrical micro ion trap by resonance excitation of the secular motion is observed to be strongly dependent on the frequency of the secular motion at resonance. Both the intensity of the ion signal and the mass resolution of the resulting mass spectrum are increased when the ion secular frequency is approximately that of a nonlinear resonance of the trap. The resonances are attributed to electrical as well as geometrical considerations.

Journal Article↗