PubMed Health⌕ Search

Biomedical subjects

Peter T C So

Publications and source records attributed to Peter T C So.

At least 19 recordsLinked to original sources

Investigating mechanisms of collagen thermal denaturation by high resolution second-harmonic generation imaging.

We apply the technique of second-harmonic generation (SHG) microscopy to obtain large area submicron resolution image of Type I collagen from rat tail tendon as it is heated from 40 degrees C to 70 degrees C for 0-180 min. The change in the collagen structure as reflected in its SHG image is observed at length scales from submicron to hundreds of microns. We observed that heating the tendon below the temperature of 54 degrees C does not produce any change in the averaged SHG intensity. At the heating temperature of 54 degrees C and above, we find that increasing the heating temperature and time leads to decreasing SHG intensity. As the tendon is heated above 54 degrees C, the regions where the SHG signal vanish and form a tiger-tail like pattern. In addition, a decrease in the SHG signal occurs uniformly throughout the tendon. By comparing the relative SHG intensities in small and large areas, we found that the denaturation process responsible for forming the tiger-tail like pattern occurs at a higher rate than the global denaturation process occurring throughout the tendon. We also measured the fibril spacing and found that it remains constant at 1.61 +/- 0.04 micron for all heating temperature and times. The constant fibril density shows that the global denaturation process occurs at a length scale smaller than the size of the fibril. Our results show that second-harmonic generation microscopy is effective in monitoring the thermal damage to collagen and has potential applications in biomedicine.

Animals↗

Extended resolution wide-field optical imaging: objective-launched standing-wave total internal reflection fluorescence microscopy.

Standing-wave total-internal-reflection fluorescence (SW-TIRF) microscopy uses a super-diffraction-limited standing evanescent wave to extract the high-spatial-frequency content of an object through a diffraction-limited optical imaging system. The effective point-spread function is better than a quarter of the emission wavelength. With a 1.45 numerical aperture objective and 532 nm excitation wavelength, a Rayleigh resolution of approximately 100 nm can be achieved, which is better than twice the resolution of conventional TIRF microscopy. This first experimental realization of SW-TIRF in an objective-launched geometry demonstrates the potential for extended resolution imaging at high speed by using wide-field microscopy.

Equipment Design↗

Frequency domain lifetime and spectral imaging microscopy.

In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.

Journal Article↗

Intact corneal stroma visualization of GFP mouse revealed by multiphoton imaging.

The aim of this work is to demonstrate that multiphoton microscopy is a preferred technique to investigate intact cornea structure without slicing and staining. At the micron resolution, multiphoton imaging can provide both large morphological features and detailed structure of epithelium, corneal collagen fibril bundles and keratocytes. A large area multiphoton cross-section across an intact eye excised from a GFP mouse was obtained by a homebuilt multiphoton microscope. The broadband multiphoton fluorescence (435-700 nm) and second harmonic generation (SHG, 360-400 nm) signals were generated by the 760 nm output of a femtosecond titanium-sapphire laser. A water immersion objective (Fluor, 40X, NA 0.8; Nikon) was used to facilitate imaging the curve ocular surface. The multiphoton image over entire cornea provides morphological information of epithelial cells, keratocytes, and global collagen orientation. Specifically, our planar, large area multiphoton image reveals a concentric pattern of the stroma collagen, indicative of the laminar collagen organization throughout the stroma. In addition, the green fluorescence protein (GFP) labeling contributed to fluorescence contrast of cellular area and facilitated visualizing of inactive keratocytes. Our results show that multiphoton imaging of GFP labeled mouse cornea manifests both morphological significance and structural details. The second harmonic generation imaging reveals the collagen orientation, while the multiphoton fluorescence imaging indicates morphology and distribution of cells in cornea. Our results support that multiphoton microscopy is an appropriate technology for further in vivo investigation and diagnosis of cornea.

Animals↗

Detecting single quantum dot motion with nanometer resolution for applications in cell biology.

Quantum dots (QDs), semiconductor particles of nanometer dimension, have emerged as excellent fluorescent analogs in tracer experiments with single molecule sensitivity for bioassays. Cell imaging greatly benefits from the remarkable optical and physical properties of these inorganic nanocrystals: QDs are much brighter and exhibit a higher resistance to photobleaching than traditional fluorophores, and their narrow emission spectrum and flexible surface chemistry make them particularly suitable for multiplex imaging. Here, we have demonstrated the achievement of a nanometer spatial resolution on the position of a single QD in a simple optomechanical instrument using a high-sensitivity low-noise detector, an intensified CCD camera. Furthermore, nanometer variations in the amplitude of a QD's sinusoidal oscillations could be quantitatively distinguished after fast Fourier transform (FFT) based data processing. As confirmed by experiments where QDs were attached to the surface of bovine aortic endothelial cells, this method can be exploited in biology to assess molecular and subcellular contributions to responses such as motility, intracellular trafficking, and mechanotransduction, with high resolution and minimal disturbance to cells.

Animals↗

Multiphoton autofluorescence and second-harmonic generation imaging of the ex vivo porcine eye.

PURPOSE: The purpose of this work was to demonstrate the use of the combined imaging modality of multiphoton autofluorescence and second-harmonic generation (SHG) microscopy in obtaining spectrally resolved morphologic features of the cornea, limbus, conjunctiva, and sclera in whole, ex vivo porcine eyes. METHODS: The 780-nm output of a femtosecond, titanium-sapphire laser was used to induce broadband autofluorescence (435-700 nm) and SHG (390 nm) from various regions of the surface of ex vivo porcine eyes. A water-immersion objective was used for convenient imaging of the curved surface of the eye. RESULTS: Multiphoton autofluorescence was useful in identifying cellular structures of the different domains of the ocular surface, and the SHG signal can be used to resolve collagen organization within the cornea stroma and sclera of ex vivo porcine eyes. CONCLUSIONS: Multiphoton autofluorescence and SHG microscopy have been demonstrated to be an effective technique for resolving, respectively, the cellular and collagen structures within the ocular surface of ex vivo porcine eyes. SHG imaging resolved the difference in structural orientations between corneal and sclera collagen fibers. Specifically, the corneal collagen is organized in a depth-dependent fashion, whereas the scleral collagen is randomly packed. Because this technique does not require histologic preparation procedures, it has the potential to be applied for in vivo studies with minimal disturbance to the eye.

Animals↗

Single-photon counting multicolor multiphoton fluorescence microscope.

We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

Data Display↗

Multi-photon excitation of intrinsic protein fluorescence and its application to pharmaceutical drug screening.

The majority of proteins contain intrinsic fluorophores as natural sensors of molecular structures, dynamics, and interactions. The intrinsic protein fluorescence signal allows for the label-free and, hence, undisturbed and rapid study of protein-ligand interactions. Ultraviolet-based drug screening is hampered by the background, photobleaching, light scattering, inner filter effects, and interfering assay compounds. Such problems can be overcome by means of molecular three-photon excitation (3PE) with infrared femtosecond light pulses since longer excitation wavelengths result in less Raleigh scattering, and the subfemtoliter (confocal-like) 3PE volume minimizes out-of-focus photobleaching, background generation, and inner filter effects. We demonstrate the general feasibility of 3PE for protein spectroscopy and illustrate the technique's excellent potential for high-throughput screening. By using the intrinsic fluorescence intensity of a protein-substrate, we were able to discriminate between ligands of different affinities in binding assays.

Computer-Aided Design↗

Cell stiffness and receptors: evidence for cytoskeletal subnetworks.

Viscoelastic models of cells often treat cells as homogeneous objects. However, studies have demonstrated that cellular properties are local and can change dramatically on the basis of the location probed. Because membrane receptors are linked in various ways to the intracellular space, with some receptors linking to the cytoskeleton and others diffusing freely without apparent linkages, the cellular physical response to mechanical stresses is expected to depend on the receptor engaged. In this study, we tested the hypothesis that cellular mechanical stiffness as measured via cytoskeletally linked receptors is greater than stiffness measured via receptors that are not cytoskeletally linked. We used a magnetic micromanipulator to apply linear stresses to magnetic beads attached to living cells via selected receptors. One of the receptor classes probed, the dystroglycan receptors, is linked to the cytoskeleton, while the other, the transferrin receptors, is not. Fibronectin-coated beads were used to test cellular mechanical properties of the cytoskeleton without membrane dependence by allowing the beads to endocytose. For epithelial cells, transferrin-dependent stiffness and endocytosed bead-dependent stiffness were similar, while dystroglycan-dependent stiffness was significantly lower. For smooth muscle cells, dystroglycan-dependent stiffness was similar to the endocytosed bead-dependent stiffness, while the transferrin-dependent stiffness was lower. The conclusion of this study is that the measured cellular stiffness is critically influenced by specific receptor linkage and by cell type and raises the intriguing possibility of the existence of separate cytoskeletal networks with distinct mechanical properties that link different classes of receptors.

Cell Line↗

Mechanotransduction through growth-factor shedding into the extracellular space.

Physical forces elicit biochemical signalling in a diverse array of cells, tissues and organisms, helping to govern fundamental biological processes. Several hypotheses have been advanced that link physical forces to intracellular signalling pathways, but in many cases the molecular mechanisms of mechanotransduction remain elusive. Here we find that compressive stress shrinks the lateral intercellular space surrounding epithelial cells, and triggers cellular signalling via autocrine binding of epidermal growth factor family ligands to the epidermal growth factor receptor. Mathematical analysis predicts that constant rate shedding of autocrine ligands into a collapsing lateral intercellular space leads to increased local ligand concentrations that are sufficient to account for the observed receptor signalling; direct experimental comparison of signalling stimulated by compressive stress versus exogenous soluble ligand supports this prediction. These findings establish a mechanism by which mechanotransduction arises from an autocrine ligand-receptor circuit operating in a dynamically regulated extracellular volume, not requiring induction of force-dependent biochemical processes within the cell or cell membrane.

Animals↗

Antecedents of two-photon excitation laser scanning microscopy.

In 1931, Maria Göppert-Mayer published her doctoral dissertation on the theory of two-photon quantum transitions (two-photon absorption and emission) in atoms. This report describes and analyzes the theoretical and experimental work on nonlinear optics, in particular two-photon excitation processes, that occurred between 1931 and the experimental implementation of two-photon excitation microscopy by the group of Webb in 1990. In addition to Maria Göppert-Mayer's theoretical work, the invention of the laser has a key role in the development of two-photon microscopy. Nonlinear effects were previously observed in different frequency domains (low-frequency electric and magnetic fields and magnetization), but the high electric field strength afforded by lasers was necessary to demonstrate many nonlinear effects in the optical frequency range. In 1978, the first high-resolution nonlinear microscope with depth resolution was described by the Oxford group. Sheppard and Kompfner published a study in Applied Optics describing microscopic imaging based on second-harmonic generation. In their report, they further proposed that other nonlinear optical effects, such as two-photon fluorescence, could also be applied. However, the developments in the field of nonlinear optical stalled due to a lack of a suitable laser source. This obstacle was removed with the advent of femtosecond lasers in the 1980s. In 1990, the seminal study of Denk, Strickler, and Webb on two-photon laser scanning fluorescence microscopy was published in Science. Their paper clearly demonstrated the capability of two-photon excitation microscopy for biology, and it served to convince a wide audience of scientists of the potential capability of the technique.

History, 20th Century↗

Performances of high numerical aperture water and oil immersion objective in deep-tissue, multi-photon microscopic imaging of excised human skin.

Multi-photon fluorescence microscopy (MPFM) is a powerful technique for imaging scattering, biological specimens in depth. In addition to the sectioning effect generated by the point-like excitation volume, the near-infrared wavelengths used for multi-photon excitation allow deeper penetration into optically turbid specimens. In physiological specimens, the optical properties such as the scattering coefficients and refractive indices are often heterogeneous. In these specimens, it is not clear which type of immersion objective can provide optimized images in-depth. In particular, in-depth dermatological imaging applications using MPFM requires such optimization to obtain qualitative and quantitative information from the skin specimens. In this work, we address this issue by comparing the performances of two common types of high numerical aperture (NA) objectives: water-immersion and oil-immersion. A high-quality water-immersion objective (Zeiss, 40 x C-Apochromat, NA 1.2) and a comparable oil-immersion objective (Zeiss, 40 x Fluar, NA 1.25) were used for in-depth imaging of autofuorescent excised human skin and sulforhodamine B treated human skin specimens. Our results show that in the epidermal layers, the two types of immersion objectives perform comparably. However, in the dermis, multi-photon imaging using the oil immersion objective results in stronger fluorescence detection. These observations are most likely due to the degraded point-spread-function (PSF) caused by refractive index mismatch between the epidermis and the dermis.

Dermis↗

Two-photon confocal microscopy: a nondestructive method for studying wound healing.

Two-photon confocal microscopy is a new technology useful in nondestructive analysis of tissue. The pattern generated from laser-excited autofluorescence and second harmonic signals can be analyzed to construct a three-dimensional, microanatomical, structural image. The healing of full-thickness guinea pig skin wounds was studied over a period of 28 days using two-photon confocal microscopy. Three-dimensional data were rendered from two-dimensional images and compared with conventional, en face, histologic sections. Two-photon confocal microscopy images show resolution of muscle, fascia fibers, collagen fibers, inflammatory cells, blood vessels, and hair. Although these images do not currently have the resolution of standard histology, the ability to noninvasively acquire three-dimensional images of skin promises to be an important tool in wound-healing studies.

Animals↗

Evaluation of fluorescent probe surface intensities as an indicator of transdermal permeant distributions using wide-area two-photon fluorescence microscopy.

The application of high-speed two-photon fluorescence microscopy (HTPM) to examine transdermal transport processes has enabled the noninvasive visualization of permeant spatial distributions over a larger, more clinically relevant wide area of the skin. Earlier studies demonstrated that the transdermal fluorescent probe distribution over a 2 x 2 mm skin area was well represented by a significantly reduced sampling of the 400 microscale skin sites (100 x 100 microm) constituting the wide area. In the present study, the 400 microscale skin sites are considered individually, and the site-to-site variability in permeant distributions is used as a model to reflect the range in experimentally measured skin permeabilities resulting from the inherent stratum corneum structural heterogeneity. The correlation established between the permeant surface intensity and the corresponding permeant intensity gradient at each skin site provides an indication of the potential for screening transdermal permeant distributions solely based on the evaluation of microscale permeant surface intensities. The strong linear correlation between the intensity gradient and the surface intensity for the hydrophilic model permeant, sulforhodamine B, demonstrated that surface intensities provide a robust indicator of the corresponding transdermal probe distributions at the microscale. For the hydrophobic model permeant, rhodamine B hexyl ester, however, weak correlations were observed between these two parameters. This result suggests that the stratum corneum microscale surface intensity does not validly capture the corresponding intensity gradients for the entire range of skin permeabilities typically encountered as a result of the inherent stratum corneum heterogeneity.

Administration, Cutaneous↗

Visualization of oleic acid-induced transdermal diffusion pathways using two-photon fluorescence microscopy.

In a novel application of dual-channel high-speed two-photon fluorescence microscopy, the skin autofluores-cence and the transdermal fluorescent model drug spatial distributions were imaged simultaneously over precisely the same spatial coordinates. The dual channels enable the detection of the fluorescence emission wavelengths characteristic of the endogenous (intrinsic) skin fluorophores, as well as of the rhodamine-based model drug intensity emission at a different wavelength range of the fluorescence emission spectrum. These fluorescent model drugs delineate the oleic acid induced changes in permeant diffusion with respect to the skin structural features over the 0.3 mm by 0.3 mm skin area imaged per skin sample. The dual-channel high-speed two-photon fluorescence microscopy studies presented here provide evidence for the existence of intracorneocyte diffusion in addition to the commonly cited lipid multilamellar transdermal pathway. The image quantification analysis methodology introduced in this paper reveals that intracorneocyte diffusion exists for the hydrophobic (rhodamine B hexyl ester) and for the hydrophilic (sulforhodamine B) model drugs, in the absence of oleic acid chemical enhancer action. The mechanism of oleic acid chemical enhancer action, however, depends on the model drug physicochemical properties, where the oleic acid induces hydrophobic model drug localization to the lipid multilamellar region, while increasing the hydrophilic model drug lipid to corneocyte partitioning.

Biological Transport↗

Three-dimensional cellular deformation analysis with a two-photon magnetic manipulator workstation.

The ability to apply quantifiable mechanical stresses at the microscopic scale is critical for studying cellular responses to mechanical forces. This necessitates the use of force transducers that can apply precisely controlled forces to cells while monitoring the responses noninvasively. This paper describes the development of a micromanipulation workstation integrating two-photon, three-dimensional imaging with a high-force, uniform-gradient magnetic manipulator. The uniform-gradient magnetic field applies nearly uniform forces to a large cell population, permitting statistical quantification of select molecular responses to mechanical stresses. The magnetic transducer design is capable of exerting over 200 pN of force on 4.5-microm-diameter paramagnetic particles and over 800 pN on 5.0-microm ferromagnetic particles. These forces vary within +/-10% over an area 500 x 500 microm2. The compatibility with the use of high numerical aperture (approximately 1.0) objectives is an integral part of the workstation design allowing submicron-resolution, three-dimensional, two-photon imaging. Three-dimensional analyses of cellular deformation under localized mechanical strain are reported. These measurements indicate that the response of cells to large focal stresses may contain three-dimensional global deformations and show the suitability of this workstation to further studying cellular response to mechanical stresses.

3T3 Cells↗