PubMed Health⌕ Search

Biomedical subjects

Peter T Mortensen

Publications and source records attributed to Peter T Mortensen.

3 recordsLinked to original sources

A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome.

OBJECTIVES: A randomized trial was done to compare single-chamber atrial (AAI) and dual-chamber (DDD) pacing in patients with sick sinus syndrome (SSS). Primary end points were changes in left atrial (LA) size and left ventricular (LV) size and function as measured by M-mode echocardiography. BACKGROUND: In patients with SSS and normal atrioventricular conduction, it is still not clear whether the optimal pacing mode is AAI or DDD pacing. METHODS: A total of 177 consecutive patients (mean age 74 +/- 9 years, 73 men) were randomized to treatment with one of three rate-adaptive (R) pacemakers: AAIR (n = 54), DDDR with a short atrioventricular delay (n = 60) (DDDR-s), or DDDR with a fixed long atrioventricular delay (n = 63) (DDDR-l). Before pacemaker implantation and at each follow-up, M-mode echocardiography was done to measure LA and LV diameters. Left ventricular fractional shortening (LVFS) was calculated. Analysis was on an intention-to-treat basis. RESULTS: Mean follow-up was 2.9 +/- 1.1 years. In the AAIR group, no significant changes were observed in LA or LV diameters or LVFS from baseline to last follow-up. In both DDDR groups, LA diameter increased significantly (p < 0.05), and in the DDDR-s group, LVFS decreased significantly (p < 0.01). Atrial fibrillation was significantly less common in the AAIR group, 7.4% versus 23.3% in the DDDR-s group versus 17.5% in the DDDR-l group (p = 0.03, log-rank test). Mortality, thromboembolism, and congestive heart failure did not differ between groups. CONCLUSIONS: During a mean follow-up of 2.9 +/- 1.1 years, DDDR pacing causes increased LA diameter, and DDDR pacing with a short atrioventricular delay also causes decreased LVFS. No changes occur in LA or LV diameters or LVFS during AAIR pacing. Atrial fibrillation is significantly less common during AAIR pacing.

Aged↗

Sequential versus simultaneous biventricular resynchronization for severe heart failure: evaluation by tissue Doppler imaging.

BACKGROUND: Cardiac resynchronization therapy (CRT) by means of simultaneous biventricular pacing improves left ventricular systolic performance and synchrony in patients with heart failure and bundle-branch block. We used tissue tracking and 3D echocardiography to evaluate the impact of sequential CRT with individualized interventricular delay programming. METHODS AND RESULTS: Twenty consecutive patients with severe heart failure and left bundle-branch block were included. Tissue tracking and 3D echocardiography were carried out before and on the day after pacemaker implantation. Eleven different interventricular delays were examined in each patient. Patients were reexamined after 3 months. Simultaneous CRT immediately reduced the extent of myocardium displaying delayed longitudinal contraction (DLC) from 48.6+/-16% to 23.2+/-13% (P<0.01) and increased left ventricular ejection fraction percentage (LVEF%) from 22.4+/-6% to 29.7+/-5% (P<0.01). However, optimum sequential CRT caused a further reduction in the extent of DLC from 23.2+/-13% to 11.1+/-7.2% (P<0.01), with a simultaneous increase in LVEF% (from 29.7+/-5% to 33.9+/-6%, P<0.01). Three months of optimum sequential CRT further improved LVEF% (from 33.6+/-6% to 38.6+/-7.2%, P<0.01). Tissue tracking detected the segments with DLC, and their location determined optimum interventricular delay programming. Compared with simultaneous CRT, sequential CRT increased diastolic filling time by 7+/-2.5%. CONCLUSIONS: Compared with simultaneous CRT, sequential CRT significantly improves left ventricular systolic and diastolic performance. Tissue tracking can be used to select optimum interventricular delay during CRT.

Aged↗

Tissue Doppler imaging predicts improved systolic performance and reversed left ventricular remodeling during long-term cardiac resynchronization therapy.

OBJECTIVES: We sought to evaluate the long-term impact of cardiac resynchronization therapy (CRT) on left ventricular (LV) performance and remodeling using three-dimensional echocardiography and tissue Doppler imaging (TDI). BACKGROUND: Three-dimensional echocardiography and TDI allow rapid and accurate evaluation of LV volumes and performance. METHODS: Twenty-five consecutive patients with severe heart failure and bundle branch block who underwent biventricular pacemaker implantation were included. Before and after implantation of the pacemaker, three-dimensional echocardiography and TDI were performed. These examinations were repeated at outpatient visits every six months. RESULTS: Five patients (20%) died during one-year follow-up. In the remaining 20 patients, significant reductions in LV end-diastolic volume and LV end-systolic volume of 9.6 +/- 14% and 16.5 +/- 15%, respectively (p < 0.01), could be demonstrated during long-term follow-up. Accordingly, LV ejection fraction increased by 21.7 +/- 18% (p < 0.01). According to a newly developed TDI technique-tissue tracking-all regional myocardial segments improved their longitudinal systolic shortening (p < 0.01). The extent of the LV base displaying delayed longitudinal contraction, as detected by TDI before pacemaker implantation, predicted long-term efficacy of CRT. The QRS duration failed to predict resynchronization efficacy. CONCLUSIONS: Cardiac resynchronization significantly improved LV function and reversed LV remodeling during long-term follow-up. Patients likely to benefit from CRT can be identified by TDI before implantation of a biventricular pacemaker.

Bundle-Branch Block↗