PubMed Health⌕ Search

Biomedical subjects

Peter Viberg

Publications and source records attributed to Peter Viberg.

4 recordsLinked to original sources

Nanospray mass spectrometry with indirect conductive graphite coating.

An easy and cost-effective method to manufacture a robust conductive graphite coating for nanospray mass spectrometry (nESI-MS) and capillary electrophoresis (CE)-nESI-MS is described. The method involves graphite coating of a tube sleeve, into which the nESI emitter is inserted and connected to a transfer capillary, instead of coating the actual emitter. The coating, made of graphite from a pencil and epoxy glue, was stable over long periods of use (>80 h) and showed excellent resistance toward various solvents. Stable electrospray was achieved in the investigated flow range (150-900 nL x min(-)(1)), and salbutamol, diphenhydramine, and nortriptyline (M(w): 239-263 g x mol(-)(1)) were detected in the nanomole per liter range during continuous pumping. CE-nESI-MS analysis gave excellent signal-to-noise ratios for 100-fmol injections. The technique allows simple exchange of the nESI emitter to suit a specific flow rate, and it minimizes risk of corona discharge.

Journal Article↗

In-capillary micro solid-phase extraction and capillary electrophoresis separation of heterocyclic aromatic amines with nanospray mass spectrometric detection.

A miniaturised technique to analyse and detect heterocyclic aromatic amines (HAs) using micro solid-phase extraction ( microSPE) coupled on-line (in-capillary) to capillary electrophoresis (CE) separation with nanospray (nESI) mass spectrometry (MS) detection has been developed. HAs are mutagenic and carcinogenic compounds formed at low levels in protein-rich food during cooking. Due to the low concentrations of HAs and the high complexity of the matrix in which they exist, sensitive and selective analytical methods are required for quantification. microSPE was performed on a packed bed of C(18 )particles inside the CE capillary, which minimised the dead volume. The on-line coupling of SPE, CE and nESI-MS reduced the time for extraction and identification to less than half an hour, which will allow for screening of several samples per day. The new technique provides short analysis time, low sample and solvent consumption, and HAs in standard solutions were easily detected at 12-17 fmol injections, and in spiked urine samples at 750-810 fmol injections.

Journal Article↗

Affinity two-phase partitioning in acoustically levitated drops.

Miniaturized (<1 microL) biospecific affinity two-phase partitioning in an acoustically levitated drop is described. Miniaturization commonly gives unfavorable surface/volume ratios, but in the levitation approach adsorption problems are minimized since the only surrounding wall is the liquid/air interface of the drop. Biotinylated liposomes were partitioned in aqueous poly(ethylene glycol)/dextran two-phase drops with NeutrAvidin-dextran as the affinity ligand. A two-phase drop was trapped and manipulated in a node of a standing ultrasonic wave. Alternatively, a two-phase system was formed by levitation and evaporation of a polymer one-phase drop. Phase mixing was achieved by adjusting the ultrasonic field and phase separation by readjusting the field. NeutrAvidin-dextran brought about the redistribution of biotinylated liposomes from the poly(ethylene glycol)-rich phase into the dextran-rich phase. Thus, an entire affinity two-phase separation procedure, including mixing of the phases and incubation to allow affinity interactions to develop under constant volume, followed by phase separation under controlled evaporation, can be performed in a single levitated drop. This miniaturized technique would allow the separation of biologically active membranes or organelles from individual cells for analysis.

Journal Article↗

Nanoparticles as pseudostationary phase in capillary electrochromatography/ESI-MS.

A novel technique that uses polymer nanoparticles as pseudostationary phase in capillary electrochromatography with electrospray ionization mass spectrometry detection is described. A continuous full filling technique in which the nanoparticles were suspended in the entire electrolyte volume as well as a conventional partial filling technique is presented. No nanoparticles entered the mass spectrometer, which was fitted with an orthogonal electrospray interface, despite the continuous flow of nanoparticles into the interface. Nanoparticles (average diameter 160 nm) were prepared from methacrylic acid, methyl methacrylate, and trimethylolpropane trimethacrylate by utilizing a precipitation polymerization technique. Salbutamol, nortriptyline, and diphenhydramine were used as analytes. The interaction between analytes and nanoparticles was found to be predominantly ionic.

Journal Article↗