PubMed Health⌕ Search

Biomedical subjects

Petra Georg

Publications and source records attributed to Petra Georg.

7 recordsLinked to original sources

The role of particle therapy in the treatment of locally recurrent rectal cancer: a systematic review.

BACKGROUND: Colorectal cancer is a common malignancy. Advancements in multimodality treatment have improved outcomes. About 2-10% of patients will have a local recurrence even after optimal treatment. Salvage surgical treatment is the treatment of choice, however, in posterior and lateral recurrences, surgery is linked to a high rate of treatment-related morbidity. Some recurrences remain unresectable even after neoadjuvant treatment. MATERIALS AND METHODS: A systematic literature review was performed to search for studies on curative-intent radiation therapy (RT) with photons, stereotactic body radiation therapy (SBRT) and particle beam therapy. The aim of the literature search was to define the role of particle therapy in the treatment of patients with unresectable or inoperable local recurrences of rectal cancer where neoadjuvant treatment is unlikely to result in downstaging, leaving patients with RT as the only curative treatment option. RESULTS: 32 studies which fulfil the criteria were identified. In general, SBRT and particle beam therapy permitted the application of significantly higher doses to the target without a concomitant increase in treatment-related toxicities. CONCLUSIONS: For unresectable and inoperable locally recurrent rectal cancer ablative radiotherapy techniques such as SBRT and particle beam therapy offer a curative treatment approach as an alternative to surgery. SBRT can be offered for small local and nodal recurrences, while particle beam therapy can be offered for larger recurrences and complex shapes spanning several anatomical compartments as well. Further research is needed to stratify patients according to their need and eligibility for the different possible modalities of curative-intent RT.

Humans↗

The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: clinical feasibility and preliminary results.

PURPOSE: The aims of this study were to investigate the clinical feasibility and to report on preliminary treatment outcomes of combined intracavitary/interstitial brachytherapy, using a novel applicator and magnetic resonance imaging (MRI)-based treatment planning in patients with locally advanced cervical cancer. METHODS AND MATERIALS: A total of 22 cervical cancer patients with insufficient response and/or unfavorable topography after external-beam irradiation were included in this study. Parametrial extent of the disease in these patients was judged to exceed the coverage limit of intracavitary brachytherapy alone. A modified tandem/ring (T/R) applicator for guidance of parametrial needles (N) was used to perform high-dose-rate-brachytherapy with MRI-based treatment planning. Clinical feasibility and preliminary treatment outcomes were assessed. RESULTS: A total of 44 interstitial needle implants were performed. The spatial relations between the T/R + N applicator, high-risk clinical target volume, and organs at risk were visible clearly in all cases. Accurate and reproducible needle placement could be achieved in the majority of cases. No severe adverse events were caused by the intervention. The mean follow-up period was 20 months (range, 5-35 months). No G3 to G4 early or persistent late side effects were observed. Complete remission was achieved in 21 patients (95%). One local recurrence was observed within the high-risk clinical target volume area during follow-up. CONCLUSIONS: Our preliminary clinical experience indicates that combined intracavitary and interstitial MRI-based brachytherapy in patients with significant residual disease after external-beam therapy extending up to the distal third of parametria is feasible and allows excellent local control and a low rate of morbidity.

Adult↗

Factors influencing bowel sparing in intensity modulated whole pelvic radiotherapy for gynaecological malignancies.

BACKGROUND AND PURPOSE: To evaluate the influence of uterus and bladder size on large and small bowel sparing with intensity modulated whole pelvic radiotherapy (IM-WPRT) in gynecologic patients. PATIENTS AND METHODS: Twenty patients were selected; 10 women with cervical cancer treated with definitive radiotherapy (group 'DEF') and 10 endometrial cancer patients treated postoperatively (group 'POST'). Bladder, rectal wall, small (SB) and large bowel (LB) were delineated as organs at risk. A conformal four field technique and a seven field IMRT plan (prescription dose 50.4 Gy) were compared in terms of DVH and various target parameters. RESULTS: At doses between 40 and 50.4 Gy statistically significant improvements (P<0.05) were observed for IM-WPRT for irradiated volume of rectal wall and bladder. In both patient groups, with IMRT the average irradiated volume of SB was reduced by a factor of 6 at 50.4Gy. This ratio was 2 for LB. In the DEF group the effect of SB-sparing with IMRT correlated with bladder size (correlation coefficient 0.70) while it did not correlate in the postoperative group. The effect of LB-sparing decreased with increasing bladder size in both groups but the impact of IMRT was larger for postoperative patients. CONCLUSIONS: IMRT significantly reduced the absolute volume of rectal wall, bladder and bowel irradiated at the prescribed dose level in gynaecologic patients. Main differences between POST and DEF patients receiving IM-WPRT were absolute volumes of LB irradiated to doses between 35 and 50Gy, suggesting an impact of intact uterus on LB volume in the pelvis. POST patients seem to benefit most from elective nodal IMRT. Bladder filling is an important co-factor influencing the benefit of IMRT with respect to OAR sparing.

Cohort Studies↗

Inverse planning--a comparative intersystem and interpatient constraint study.

PURPOSE: To compare commercial treatment-planning systems (TPS) for inverse planning (IP) and to assess constraint variations for specific IMRT indications. MATERIAL AND METHODS: For IP, OTP, XiO and BrainSCAN were used and step-and-shoot intensity-modulated radiotherapy (IMRT) delivery was assumed. Based on identical constraints, IP was performed for a prostate, head and neck, brain, and gynecologic case. IMRT plans were compared in terms of conformity/homogeneity, dose-volume histograms (DVHs), and delivery efficiency. For ten patients each of a class of indications, constraint variations were evaluated. RESULTS: IMRT plans were comparable concerning minimum target dose, homogeneity, conformity, and maximum doses to organs at risk. Larger differences were seen in dose gradients outside the target, monitor units, and segment number. Using help structures proved efficient to shape isodoses and to reduce segmentation workload. For IMRT class solutions, IP constraint variations depended on anatomic site. CONCLUSION: IP systems requiring doses as input and having objective functions based on physical parameters had a very similar performance. Constraint templates can be established for a class of IMRT indications.

Brain Neoplasms↗

The relative benefits of endurance and strength training on the metabolic factors and muscle function of people with type 2 diabetes mellitus.

OBJECTIVE: To compare the effects of a 4-month strength training (ST) versus aerobic endurance training (ET) program on metabolic control, muscle strength, and cardiovascular endurance in subjects with type 2 diabetes mellitus (T2D). DESIGN: Randomized controlled trial. SETTING: Large public tertiary hospital. PARTICIPANTS: Twenty-two T2D participants (11 men, 11 women; mean age +/- standard error, 56.2+/-1.1 y; diabetes duration, 8.8+/-3.5 y) were randomized into a 4-month ST program and 17 T2D participants (9 men, 8 women; mean age, 57.9+/-1.4 y; diabetes duration, 9.2+/-1.7 y) into a 4-month ET program. INTERVENTIONS: ST (up to 6 sets per muscle group per week) and ET (with an intensity of maximal oxygen consumption of 60% and a volume beginning at 15 min and advancing to a maximum of 30 min 3x/wk) for 4 months. MAIN OUTCOME MEASURES: Laboratory tests included determinations of blood glucose, glycosylated hemoglobin (Hb A1c), insulin, and lipid assays. RESULTS: A significant decline in Hb A1c was only observed in the ST group (8.3%+/-1.7% to 7.1%+/-0.2%, P=.001). Blood glucose (204+/-16 mg/dL to 147+/-8 mg/dL, P<.001) and insulin resistance (9.11+/-1.51 to 7.15+/-1.15, P=.04) improved significantly in the ST group, whereas no significant changes were observed in the ET group. Baseline levels of total cholesterol (207+/-8 mg/dL to 184+/-7 mg/dL, P<.001), low-density lipoprotein cholesterol (120+/-8 mg/dL to 106+/-8 mg/dL, P=.001), and triglyceride levels (229+/-25 mg/dL to 150+/-15 mg/dL, P=.001) were significantly reduced and high-density lipoprotein cholesterol (43+/-3 mg/dL to 48+/-2 mg/dL, P=.004) was significantly increased in the ST group; in contrast, no such changes were seen in the ET group. CONCLUSIONS: ST was more effective than ET in improving glycemic control. With the added advantage of an improved lipid profile, we conclude that ST may play an important role in the treatment of T2D.

Aged↗

The use of the source-skin distance measuring bridge indeed reduces skin teleangiectasia after interstitial boost in breast conserving therapy.

BACKGROUND AND PURPOSE: In 1990 the skin source measuring bridge was proposed as a tool to measure (1) the distance between the interstitial implant and the overlying skin during brachytherapy boost treatment as well as (2) the distances between the lateral source end and the exit point of the guide needle. The present study reports on the clinical experience using the source skin measuring bridge with respect to incidence and grade of teleangiectasia, and their relation to source skin distances and doses. PATIENTS AND METHODS: Two hundred and twenty-two breast cancer patients (229 breasts) treated between 1983 and 1996 with breast conserving therapy including a brachytherapy boost were scored on the occurrence of teleangiectasia. The minimum distance between the sources (above implant and laterally) and the skin surface were measured. RESULTS: If no bridge was used the appearance of teleangiectasia in the epiderm above the implant is 77, 63 and 50% for boost doses of 25, 20 and 15 Gy, respectively. For brachytherapy boost doses of 25 and 20 Gy and distances smaller than 10mm between the implant and the overlying epiderm, as determined with the skin source measuring bridge, the appearance of teleangiectasia was 78 and 46%, respectively. When respecting provisional dosimetry to spare the skin for a boost dose of 15 Gy, resulting in distances between 10 and 15 mm for the implant overlying skin and distances between 5 and 10 mm for the lateral skin, teleangiectasia can be reduced to a minimum (6.3% above and 3.3% laterally). While in a univariate analysis several parameters (use of the bridge, boost dose, boost modality, external beam therapy modality) were predictive factors, the use of the bridge remained the only significant variable in a multivariate analysis. CONCLUSIONS: The skin source measuring bridge reduces teleangiectasia after interstitial brachytherapy boost treatment. A hypothesis made previously relating teleangiectasia and source skin distances was verified and extended. Even when 3D planning is used, the bridge allows for a provisional calculation of the security margins between source positions and the skin at the time of BT implantation to assure a correct needle positioning from the beginning, instead of correcting dwell times later on to avoid unnecessary high skin doses.

Adult↗

Influence of metabolic control on splanchnic glucose uptake, insulin sensitivity, and the time required for glucose absorption in patients with type 1 diabetes.

OBJECTIVE: The relationship between splanchnic glucose uptake (SGU) after oral glucose administration and metabolic control in type 1 diabetic patients is controversial. We estimated SGU as well as peripheral glucose uptake and the time required for glucose absorption by a validated method, the oral glucose (OG) clamp, in type 1 diabetic patients with different levels of long-term glycemic control. RESEARCH DESIGN AND METHODS: An OG clamp (which combines a hyperinsulinemic clamp [120 mU. m(-2). min(-1)] with an OR load [75 g] during steady-state glucose uptake) was performed in eight type 1 diabetic patients with good metabolic control (DG) (HbA(1c) 6.1 +/- 0.2%, BMI 23.1 +/- 0.7 kg/m(2)), eight type 1 diabetic patients with poor metabolic control (DP) (HbA(1c) 8.5 +/- 0.3%, BMI 25.4 +/- 1.4 kg/m(2)), and eight healthy matched control subjects (C) (HbA(1c) 5.1 +/- 0.1%, BMI 25 +/- 1.3 kg/m(2)) to determine SGU, glucose uptake, and glucose absorption. RESULTS: Glucose uptake calculated from 120 to 180 min during the clamp was 9.13 +/- 0.55 mg. kg(-1). min(-1) in C, 8.18 +/- 0.71 mg. kg(-1). min(-1) in DG, and 7.42 +/- 0.96 mg. kg(-1). min(-1) in DP (NS). Glucose absorption was 140 +/- 6 min in C, 156 +/- 4 min in DG, and 143 +/- 7 min in DP (NS). The respective calculated SGU was 14.5 +/- 5.6% in C, 17.8 +/- 3.1% in DG, and 18.8 +/- 4.2% in DP (NS) and did not correlate with HbA(1c) values. CONCLUSIONS: Peripheral glucose uptake, SGU after oral glucose administration, and the glucose absorption time were not different in type 1 diabetic patients independent of glycemic control when compared with healthy subjects.

Adult↗