Phil Segel

Publications and source records attributed to Phil Segel.

3 recordsLinked to original sources

Effects of hyperbaric exposure on the integrity of the internal components of commercially available cochlear implant systems.

HYPOTHESIS: This study investigated whether pressure changes common to scuba diving and to hyperbaric oxygen therapy would not cause crush damage or leakage from critical seals in commercially available cochlear implants. BACKGROUND: The implanted packages of cochlear implants are susceptible to electrical failure caused by leakage from critical seals and to crush injury when exposed to changing barometric pressures encountered in recreational diving and in hyperbaric oxygen therapy. METHODS: Six Clarion 1.2, eight MED-EL Combi-40+, six Nucleus CI22M, and six Nucleus CI24M cochlear implants underwent three exposures at 165 feet of seawater (FSW) (6 ata abs), 99 FSW (4 ata abs), and 60 FSW (2.8 ata abs), simulating rates in accordance with U.S. Navy dive tables for nondecompression dives. Dives to 45 FSW (2.4 ata abs) simulated wound therapy. Before each dive began, after each dive, and after completion of the dive protocol, each device underwent telemetry and electrical integrity checks. All implants were returned to their respective factories for final electrical and quality control testing. RESULTS: All 26 devices completed the dive protocol. One Nucleus CI24M implant had a fault recorded at electrode lead 18 on predive and final product testing, which was absent during interval dive measurements. All 26 devices passed final electrical and quality control testing. In addition, the six Clarion units passed repeat helium leak testing. CONCLUSION: The implanted components of the Clarion 1.2, MED-EL Combi-40+, and Nucleus CI22M and CI24M were safely subjected to repeated pressure changes up to 6 atm abs, equivalent to 165 feet of seawater, without electrical failure from leakage at critical seals or crush damage.

Cochlear Implants↗

Speech dynamic range and its effect on cochlear implant performance.

This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50-dB distribution of speech envelope levels. Phoneme recognition was also obtained in ten CLARION implant users as a function of the input dynamic range from 10 to 80 dB in 10-dB steps. Acoustic amplitudes within a specified input dynamic range were logarithmically mapped into the 10-20-dB range of electric stimulation typically found in cochlear-implant users. Consistent with acoustic data, the perceptual data showed that a 50-60-dB input dynamic range produced optimal speech recognition in these implant users. The present results indicate that speech dynamic range is much greater than the commonly assumed 30-dB range. A new amplitude mapping strategy, based on envelope distribution differences between consonants and vowels, is proposed to optimize acoustic-to-electric mapping of speech sounds. This new strategy will use a logarithmic map for low-frequency channels and a more compressive map for high-frequency channels, and may improve overall speech recognition for cochlear-implant users.

Adult↗

HiResolution and conventional sound processing in the HiResolution bionic ear: using appropriate outcome measures to assess speech recognition ability.

OBJECTIVE: This study compared speech perception benefits in adults implanted with the HiResolution (HiRes) Bionic Ear who used both conventional and HiRes sound processing. A battery of speech tests was used to determine which formats were most appropriate for documenting the wide range of benefit experienced by cochlear-implant users. STUDY DESIGN: A repeated-measures design was used to assess postimplantation speech perception in adults who received the HiResolution Bionic Ear in a recent clinical trial. Patients were fit first with conventional strategies and assessed after 3 months of use. Patients were then switched to HiRes sound processing and assessed again after 3 months of use. To assess the immediate effect of HiRes sound processing on speech perception performance, consonant recognition testing was performed in a subset of patients after 3 days of HiRes use and compared with their 3-month performance with conventional processing. SETTING: Subjects were implanted and evaluated at 19 cochlear implant programs in the USA and Canada affiliated primarily with tertiary medical centers. PATIENTS: Patients were 51 postlinguistically deafened adults. MAIN OUTCOME MEASURES: Speech perception was assessed using CNC monosyllabic words, CID sentences and HINT sentences in quiet and noise. Consonant recognition testing was also administered to a subset of patients (n = 30) using the Iowa Consonant Test presented in quiet and noise. All patients completed a strategy preference questionnaire after 6 months of device use. RESULTS: Consonant identification in quiet and noise improved significantly after only 3 days of HiRes use. The mean improvement from conventional to HiRes processing was significant on all speech perception tests. The largest differences occurred for the HINT sentences in noise. Ninety-six percent of the patients preferred HiRes to conventional sound processing. Ceiling effects occurred for both sentence tests in quiet. CONCLUSIONS: Although most patients improved after switching to HiRes sound processing, the greatest differences were seen in the 'poor' performers because 'good' performers often reached ceiling performance, especially on tests in quiet. Future evaluations of cochlear-implant benefit should make use of more difficult measures, especially for 'good' users. Nonetheless, a range of difficulty must remain in test materials to document benefit in the entire population of implant recipients.

Adult↗