PubMed Health⌕ Search

Biomedical subjects

Philip Britz-McKibbin

Publications and source records attributed to Philip Britz-McKibbin.

16 recordsLinked to original sources

Treatment response variations to a single large bolus of enteral cholecalciferol in vitamin D deficient critically Ill children: Metabolomic insights for precision nutrition.

Vitamin D deficiency (VDD) is prevalent globally and in pediatric intensive care units, where it represents a modifiable risk factor that may impact patient recovery during hospitalization. Herein, we performed a retrospective analysis of serum samples from a phase-II randomized placebo-controlled trial involving a single large bolus of 10,000 IU/kg vitamin D3 ingested by critically ill children with VDD (25-OH-D < 50 nmol/L). Targeted and untargeted methods were used to comprehensively measure 6 vitamin D metabolites, 239 lipids, 68 polar metabolites, and 4 electrolytes using a multi-step data workflow for compound authentication. Complementary statistical methods classified circulating metabolites/lipids associated with vitamin D repletion following high-dose vitamin D3 intake (n&#x202f;=&#x202f;20) versus placebo (n&#x202f;=&#x202f;11) comprising an optional standard of care maintenance dose (< 1000 IU/day). There was a striking increase in median serum concentrations of 25-OH-D3 (4.7-fold), 3-epi-25-OH-D3 (24-fold) and their C3-epimer ratio (6.7-fold) in treated patients on day 3, whereas serum vitamin D3 peaked on day 1 (128-fold) unlike placebo. Treatment response differences were attributed to D3 bioavailability and C3-epimerase activity without evidence of hypercalcemia. For the first time, we report the detection of circulating 3-epi-D3 that was strongly correlated with vitamin D3 uptake (r&#x202f;=&#x202f;0.898). Metabolomic studies revealed that vitamin D sufficiency (serum 25-OH-D >75 nmol/L) coincided with lower circulating levels of 3-methylhistidine, cystine, S-methylcysteine, uric acid, and two lysophosphatidylcholines 7 days after treatment. Rapid correction of VDD was associated with indicators of lower oxidative stress, inflammation, and muscle protein turn-over that may contribute clinical benefits in high-risk critically ill children.

Humans↗

Integrative metabolomics for characterizing unknown low-abundance metabolites by capillary electrophoresis-mass spectrometry with computer simulations.

Characterization of unknown low-abundance metabolites in biological samples is one the most significant challenges in metabolomic research. In this report, an integrative strategy based on capillary electrophoresis-electrospray ionization-ion trap mass spectrometry (CE-ESI-ITMS) with computer simulations is examined as a multiplexed approach for studying the selective nutrient uptake behavior of E. coli within a complex broth medium. On-line sample preconcentration with desalting by CE-ESI-ITMS was performed directly without off-line sample pretreatment in order to improve detector sensitivity over 50-fold for cationic metabolites with nanomolar detection limits. The migration behavior of charged metabolites were also modeled in CE as a qualitative tool to support MS characterization based on two fundamental analyte physicochemical properties, namely, absolute mobility (muo) and acid dissociation constant (pKa). Computer simulations using Simul 5.0 were used to better understand the dynamics of analyte electromigration, as well as aiding de novo identification of unknown nutrients. There was excellent agreement between computer-simulated and experimental electropherograms for several classes of cationic metabolites as reflected by their relative migration times with an average error of <2.0%. Our studies revealed differential uptake of specific amino acids and nucleoside nutrients associated with distinct stages of bacterial growth. Herein, we demonstrate that CE can serve as an effective preconcentrator, desalter, and separator prior to ESI-MS, while providing additional qualitative information for unambiguous identification among isobaric and isomeric metabolites. The proposed strategy is particularly relevant for characterizing unknown yet biologically relevant metabolites that are not readily synthesized or commercially available.

Biomarkers↗

Single-step enantioselective amino acid flux analysis by capillary electrophoresis using on-line sample preconcentration with chemical derivatization.

Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.

Acetylcysteine↗

Enhanced binding and conformational selectivity in affinity capillary electrophoresis using a water-soluble resorcin[4]arene as intrinsic buffer and electrokinetic host.

Affinity capillary electrophoresis (ACE) is a widely used technique for quantifying non-covalent molecular interactions that is dependent on the specific buffer conditions selected. In this study, dynamic 1:1 host-guest inclusion complexation involving a charged resorcin[4]arene with a group of neutral corticosteroids was examined by ACE, where the macrocycle serves as both an intrinsic buffer and electrokinetic host. It was determined that over a 200% enhancement in the apparent binding constant (KB) was realized by ACE when using the host as an intrinsic buffer at pH 7.5 relative to an extrinsic sodium phosphate buffer system, which was also confirmed by 1H-NMR experiments. This report also revealed improved selectivity mediated by the discrete conformational properties of the complex among similar corticosteroid guests, as reflected by the complex mobility (mu(ep, AC)) or the relative change in complexation-induced mobility (1-mu(ep, AC)/mu(ep, C)). This latter property is a unique feature of ACE reflective of hydrodynamic size selectivity involving bulky guests or substrates. 1H-NMR and computer molecular modeling provided complementary information regarding the relative orientation, conformation and overall molecular area of the complex. The coupling of thermodynamic (KB) and electrokinetic (mu(ep, AC)) factors associated with complex formation in buffered solutions that minimize the effects of extrinsic electrolytes serves to enhance enthalpy-driven molecular recognition processes by ACE.

Adrenal Cortex Hormones↗

Dynamic unfolding of a regulatory subunit of cAMP-dependent protein kinase by capillary electrophoresis: Impact of cAMP dissociation on protein stability.

Characterization of the unfolding dynamics of a recombinant type IA regulatory subunit (RIalpha) of cyclic adenosine monophosphate (cAMP)-dependent protein kinase (cAPK) was examined by CE with UV detection. Electrophoretic separation of RIalpha by CE in a buffer devoid of cAMP resulted in rapid dissociation of the complex from the original sample due to the high negative mobility of the ligand relative to receptor. This process enabled in-capillary generation of cAMP-stripped RIalpha, which was used to estimate the apparent dissociation constant (Kd) of 0.6 +/- 0.2 microM. A comparison of RIalpha dynamic unfolding processes with urea denaturation was performed by CE with (i.e., RIalpha-cAMP) and without (i.e., cAMP-stripped RIalpha) excess cAMP in the buffer during electromigration. The presence of cAMP in the buffer confirmed greater stabilization of the protein, as reflected by a higher standard free energy change (DeltaG(U) degrees) of 10.1 +/- 0.5 kcal x mol(+1) and greater cooperativity in unfolding (m) of -2.30 +/- 0.11 kcal x mol(-1) M(-1). CE offers a rapid, yet versatile platform for probing the thermodynamics of cAPK and other types of receptor-ligand complexes in free solution.

Cyclic AMP↗

Sample preconcentration with chemical derivatization in capillary electrophoresis. Capillary as preconcentrator, microreactor and chiral selector for high-throughput metabolite screening.

New strategies for integrating sample pretreatment with chemical analyses under a single format is required for rapid, sensitive and enantioselective analyses of low abundance metabolites in complex biological samples. Capillary electrophoresis (CE) offers a unique environment for controlling analyte/reagent band dispersion and electromigration properties using discontinuous electrolyte systems. Recent work in our laboratory towards developing a high-throughput CE platform for low abundance metabolites via on-line sample preconcentration with chemical derivatization (SPCD) is primarily examined in this review, as there have been surprisingly only a few strategies reported in the literature to date. In-capillary sample preconcentration serves to enhance concentration sensitivity via electrokinetic focusing of long sample injection volumes for lower detection limits, whereas chemical derivatization by zone passing is used to expand detectability and selectivity, notably for enantiomeric resolution of metabolites lacking intrinsic chromophores using nanolitre volumes of reagent. Together, on-line SPCD-CE can provide over a 100-fold improvement in concentration sensitivity, shorter total analysis times, reduced sample handling and improved reliability for a variety of amino acid and amino sugar metabolites, which is also amenable to automated high-throughput screening. This review will highlight basic method development and optimization parameters relevant to SPCD-CE, including applications to bacterial metabolite flux and biomarker analyses. Insight into the mechanism of analyte focusing and labeling by SPCD-CE is also discussed, as well as future directions for continued research.

Amino Acids↗

Single-step analysis of low abundance phosphoamino acids via on-line sample preconcentration with chemical derivatization by capillary electrophoresis.

New strategies for rapid, sensitive and high-throughput analysis of low abundance metabolites in biological samples are required for future metabolomic research. In this report, a direct method for sub-micromolar analyses of phosphoamino acids was developed using on-line sample preconcentration with 9-fluorenylmethyloxycarbonyl chloride (FMOC) derivatization by capillary electrophoresis (CE) and UV detection. Analyte focusing by dynamic pH junction and FMOC labeling efficiency were influenced by several experimental factors including buffer pH, ionic strength, sample injection length and FMOC concentration. About a 200-fold enhancement in concentration sensitivity was achieved under optimal conditions relative to conventional off-line derivatization, as reflected by a detection limit (S/N approximately 3) of 0.1 microM. In-capillary sample preconcentration with chemical labeling by CE offers a unique single-step analytical platform for high-throughput screening of low abundance metabolites without intrinsic chromophores.

Animals↗

On-line sample preconcentration with chemical derivatization of bacterial biomarkers by capillary electrophoresis: a dual strategy for integrating sample pretreatment with chemical analysis.

Simple, selective yet sensitive methods to quantify low-abundance bacterial biomarkers derived from complex samples are required in clinical, biological, and environmental applications. In this report, a new strategy to integrate sample pretreatment with chemical analysis is investigated using on-line preconcentration with chemical derivatization by CE and UV detection. Single-step enantioselective analysis of muramic acid (MA) and diaminopimelic acid (DAP) was achieved by CE via sample enrichment by dynamic pH junction with ortho-phthalaldehyde/N-acetyl-L-cysteine labeling directly in-capillary. The optimized method resulted in up to a 100-fold enhancement in concentration sensitivity compared to conventional off-line derivatization procedures. The method was also applied toward the detection of micromolar levels of MA and DAP excreted in the extracellular medium of Escherichia coli bacterial cell cultures. On-line preconcentration with chemical derivatization by CE represents a unique approach for conducting rapid, sensitive, and high-throughput analyses of other classes of amino acid and amino sugar metabolites with reduced sample handling, where the capillary functions simultaneously as a concentrator, microreactor, and chiral selector.

Acetylcysteine↗

Complementary on-line preconcentration strategies for steroids by capillary electrophoresis.

Complementary on-line preconcentration strategies are needed when analyzing different classes of solutes in real samples by capillary electrophoresis (CE) with UV detection. The performance of three different on-line preconcentration (focusing) techniques under alkaline conditions was examined in terms of their selectivity and sensitivity enhancement for a group of steroids, including classes of androgens, corticosteroids and estrogens. Electrokinetic focusing of large sample injection plugs (up to 28% of effective capillary length or 22.1 cm) directly on-capillary can be tuned for specific classes of steroids based on changes in their mobility (velocity) using a multi-section electrolyte system in CE. A dynamic pH junction was applied for the selective resolution and focusing of weakly acidic estrogens using borate, pH 11.0 and pH 8.0 in the background electrolyte and the sample, respectively. Sweeping, using an anionic bile acid surfactant and neutral gamma-cyclodextrin (gamma-CD) under alkaline conditions (pH 8), resulted in focusing and separation of the moderately hydrophobic (non-ionic) classes of steroids, such as androgen and corticosteroids. Optimal focusing and resolution of all test steroids under a single buffer condition was realized by a dynamic pH junction-sweeping format using borate, pH 11.0 and bile acid surfactant with gamma-CD in the BGE, whereas the sample is devoid of surfactant at pH 8.0. The design of selective on-line focusing strategies in CE is highlighted by the analysis of microgram amounts of ethynyl estradiol derived from a female contraceptive pill extract using the dynamic pH junction method, which resulted in over a 100-fold enhancement in concentration sensitivity.

Contraceptives, Oral↗

Mechanistic study on analyte focusing by dynamic pH junction in capillary electrophoresis using computer simulation.

Dynamic pH junction is an on-line preconcentration method in capillary electrophoresis (CE) based on electrokinetic focusing of weakly ionic analytes with in large sample volumes in a multisection electrolyte system. In this report, experiments and computer simulations were performed to gain a better insight of the analyte focusing mechanism when a dynamic pH junction was used. A computer program, SIMUL, was used to simulate the band-narrowing process of a group for phenol derivatives under optimized buffer conditions, which were compared with experimental results. Computer simulations revealed the formation of a sharp moving pH boundary within the sample zone causing efficient focusing of long plugs of weakly acidic analytes based on their pKa. These studies offered useful information for understanding the band-narrowing process by control of the depth and lifetime of the moving pH boundary as a function of analyte pKa, sample pH, and injection length. The change in pH of the sample within the capillary was also estimated by measuring the absorbances of an analyte at two different wave-lengths. Optimization of analyte focusing resulted in enhanced detection responses of about 60-450-fold in terms of peak heights for some phenol derivatives' relation to conventional injections. Dynamic pH junction represents a novel approach to control band dispersion (peak width) and selectivity (mobility) of specific analytes for high-resolution CE separations.

Journal Article↗

On-line preconcentration strategies for trace analysis of metabolites by capillary electrophoresis.

Analysis of low concentrations of metabolites is required for new fields of biological research, such as metabolomics. In this review, recent work in our laboratory aimed at developing improved strategies for on-line sample preconcentration of metabolites by capillary electrophoresis (CE) is presented. Dynamic pH junction, sweeping and dynamic pH junction-sweeping represent three complementary methods for electrokinetic focusing of large volumes of sample directly on-capillary. Focusing selectivity and focusing efficiency are two factors that can be used to assess the suitability of each method for different classes of metabolites. Buffer properties can be selected to enhance the focusing of specific types of metabolites based on knowledge of the analyte physicochemical properties. The application of on-line preconcentration CE for trace analysis of metabolites in real samples of interest, such as biological fluids and cellular extracts, is also demonstrated. Under optimum conditions, up to three orders of magnitude increase in concentration sensitivity can be realized for several classes of metabolites, including catecholamines, purines, nucleosides, nucleotides, amino acids, steroids and coenzymes. Recent work on hyphenating on-line preconcentration with multiplexed CE is highlighted as a promising platform for sensitive and high-throughput analyses of metabolites.

Electrophoresis, Capillary↗

Determination of pyridine and adenine nucleotide metabolites in Bacillus subtilis cell extract by sweeping borate complexation capillary electrophoresis.

With a growing interest in new areas of bioanalytical research such as metabolome analysis, the development of sensitive capillary electrophoresis (CE) methods to analyze sub-microM concentrations of analytes in biological samples is required. In this report, the application of CE with sweeping by borate complexation is used to analyze a group of seven pyridine and adenine nucleotide metabolites derived from bacteria Bacillus subtilis cell extracts. Nanomolar (nM) detectability of analytes by CE with UV photometric detection is achieved through effective focusing of large sample plug (approximately 10% of capillary length) using sweeping by borate complexation method, reflected by a limit of detections (S/N = 3) of about 2 x 10(-8) M. Changes in metabolites concentrations were observed in cell extracts when using either glucose or malate as the carbon source in the culture medium. Concentration of pyridine and adenine nucleotides in cell extracts varied widely from 78.6 (+/-7.6) microM for nicotinamide-adenine dinucleotide in malate to 0.66 (+/-0.12) microM for nicotinamide-adenine dinucleotide phosphate in glucose culture medium. Concentrations of metabolites in a single cell were also estimated at millimolar (mM) level. The method was validated in terms of linearity, sensitivity and reproducibility. The application of CE by sweeping borate complexation allows for sensitive and reproducible analyses of nucleotide metabolites in complex biological samples such as bacteria cell extracts.

Adenine Nucleotides↗

Picomolar analysis of flavins in biological samples by dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection.

Sensitive capillary electrophoresis (CE) methods are required for emerging areas of biochemical research such as the metabolome. In this report, dynamic pH junction-sweeping CE with laser-induced fluorescence (LIF) detection is applied as a robust single method to analyze trace amounts of three flavin derivatives, riboflavin, flavin mononucleotide (FMN), and flavin adenine dinucleotide (FAD), from several types of samples including bacterial cell extracts, recombinant protein, and biological fluids. Submicromolar amounts of flavin coenzymes were measured directly from formic acid cell extracts of Bacillus subtilis. Significant differences in flavin concentration were measured in cell extracts derived from either glucose or malate as the carbon source in the culture media. Quantitative assessment of FAD and FMN content from selected flavoenzymes was demonstrated after heat denaturation to release noncovalently bound coenzymes and deproteinization. This method was also applied to the analysis of free flavins in pooled human plasma and urine without the need for laborious off-line sample preconcentration. Picomolar detectability of flavins by CE-LIF detection was realized with on-line preconcentration (up to 15% capillary length used for injection) by dynamic pH junction-sweeping, resulting in a limit of detection (S/N = 3) of about 4.0 pM for FAD and FMN. This represents over a 60-fold improvement in concentration sensitivity compared to those of previous techniques using conventional injections. The method was validated in terms of reproducibility, sensitivity, linearity, and specificity. Flavin analysis by dynamic pH junction-sweeping CE-LIF offers a simple, yet sensitive way to analyze trace levels of flavin metabolites from complex biological samples.

Bacillus subtilis↗

On-line focusing of flavin derivatives using Dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection.

Simple yet effective methods to enhance concentration sensitivity is needed for capillary electrophoresis (CE) to become a practical method to analyze trace levels of analytes in real samples. In this report, the development of a novel on-line preconcentration technique combining dynamic pH junction and sweeping modes of focusing is applied to the sensitive and selective analysis of three flavin derivatives: riboflavin, flavin mononucleotide (FMN) and flavin adenine dinucleotide (FAD). Picomolar (pM) detectability of flavins by CE with laser-induced fluorescence (LIF) detection is demonstrated through effective focusing of large sample volumes (up to 22% capillary length) using a dual pH junction-sweeping focusing mode. This results in greater than a 1,200-fold improvement in sensitivity relative to conventional injection methods, giving a limit of detection (S/N = 3) of approximately 4.0 pM for FAD and FMN. Flavin focusing is examined in terms of analyte mobility dependence on buffer pH, borate complexation and SDS interaction. Dynamic pH junction-sweeping extends on-line focusing to both neutral (hydrophobic) and weakly acidic (hydrophilic) species and is considered useful in cases when either conventional sweeping or dynamic pH junction techniques used alone are less effective for certain classes of analytes. Enhanced focusing performance by this hyphenated method was demonstrated by greater than a 4-fold reduction in flavin bandwidth, as compared to either sweeping or dynamic pH junction, reflected by analyte detector bandwidths <0.20 cm. Novel on-line focusing strategies are required to improve sensitivity in CE, which may be applied toward more effective biochemical analysis methods for diverse types of analytes.

Coenzymes↗

Accurately describing weak analyte-additive interactions by capillary electrophoresis.

When modeling analyte-additive interactions in capillary electrophoresis (CE), it is necessary to correct for all changes in the apparent electrophoretic mobility of an analyte that are not due to specific binding. Current models based on dynamic complexation have corrected for bulk viscosity changes in the background electrolyte (BGE) when additives are used, while assuming negligible changes in the dielectric constant and other physicochemical properties of the solution. In this report, a study of weak interactions between deoxyribonucleotides and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) revealed significant nonideality in binding isotherms. Changes in the dielectric properties of the solution due to the addition of high concentrations of HP-beta-CD to the BGE was observed to alter the electrophoretic mobility of analytes. A relative dielectric correction factor was required to normalize analyte mobilities to a reference state of zero additive concentration. The use of both a relative dielectric factor and a viscosity correction factor was found to increase the accuracy of the model, reflected by a higher degree of correlation between predicted and measured analyte mobilities. This type of correction is particularly relevant when studying weak analyte binding interactions or when using high concentrations of additive in the BGE. This work is vital for accurate determination of weak binding constants and mobility values, as well as providing a deeper understanding of the fundamental parameters influencing a separation in CE.

2-Hydroxypropyl-beta-cyclodextrin↗

High-sensitivity analyses of metabolites in biological samples by capillary electrophoresis using dynamic pH junction-sweeping.

Emerging fields of biochemical research, such as metabolomics, present challenges to current separation technologies because of the large number of metabolites present in a cell and their often low (submicromolar) concentration. Although capillary electrophoresis (CE) holds great promise as the method of choice for high-resolution separations of biological samples, it suffers from poor concentration sensitivity, especially with the use of UV detection. In CE, sweeping and dynamic pH junction represent two complementary on-line focusing techniques that have been used for sensitivity enhancement of hydrophobic and weakly acidic analytes, respectively. However, the application of either the sweeping or dynamic pH junction technique alone might, in some cases, be less effective for the analysis of certain sample mixtures. Recent work in the development of a hyphenated dynamic pH junction-sweeping technique is presented as an effective on-line method of preconcentration suitable for both hydrophilic (anionic) and hydrophobic (neutral) analytes. Sensitive analyses of flavin metabolites by CE with laser-induced fluorescence (LIF) detection is demonstrated in various biological matrixes, including cell extracts of Bacillus subtilis, pooled human plasma, as well as heat-deproteinized flavoenzymes. Enhanced analyte band narrowing and improved sensitivity is achieved for flavins using dynamic pH junction-sweeping compared to either sweeping or dynamic pH junction alone. This results in over a 1200-fold improvement in sensitivity relative to conventional injection methods, giving a limit of detection (LOD, defined as S/N = 3) of about 4.0 x 10(-12) M. Strategies for sensitive and more comprehensive analyses of other cell metabolites, including nucleotides, coenzymes, and steroids, are also discussed when using on-line focusing techniques in conjunction with multiplexed CE and UV detection.

Bacillus subtilis↗