PubMed Health⌕ Search

Biomedical subjects

Philipp A Kaufmann

Publications and source records attributed to Philipp A Kaufmann.

At least 19 recordsLinked to original sources

Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT.

PURPOSE: CT angiography (CTA) offers a valuable alternative for the diagnosis of CAD but its value in the detection of functionally relevant coronary stenoses remains uncertain. We prospectively compared the accuracy of 64-slice CTA with that of myocardial perfusion imaging (MPI) using (99m)Tc-tetrofosmin-SPECT as the gold standard for the detection of functionally relevant coronary artery disease (CAD). METHODS: MPI and 64-slice CT were performed in 100 consecutive patients. CTA lesions were analysed quantitatively and area stenoses > or =50% and > or =75% were compared with the MPI findings. RESULTS: In 23 patients, MPI perfusion defects were found (12 reversible, 13 fixed). A total of 399 coronary arteries and 1,386 segments was analysed. Eighty-four segments (6.1%) in 23 coronary arteries (5.8%) of nine patients (9.0%) were excluded owing to insufficient image quality. In the remaining 1,302 segments, quantitative CTA revealed stenoses > or =50% in 57 of 376 coronary arteries (15.2%) and stenoses > or =75% in 32 (8.5%) coronary arteries. Using a cut-off at > or =75% area stenosis, CTA yielded the following sensitivity, specificity, negative (NPV) and positive predictive value (PPV), and accuracy for the detection of any (fixed and reversible) MPI defect: by patient, 75%, 90%, 93%, 68% and 87%, respectively; by artery, 76%, 95%, 99%, 50% and 94%, respectively. CONCLUSION: Sixty-four-slice CTA is a reliable tool to rule out functionally relevant CAD in a non-selected population with an intermediate pretest likelihood of disease. However, an abnormal CTA is a poor predictor of ischaemia.

Adult↗

Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Adult↗

Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control.

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Adult↗

Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality.

PURPOSE: To evaluate prospectively the effect of average heart rate and heart rate variability on image quality at 64-section computed tomographic (CT) coronary angiography. MATERIALS AND METHODS: The study protocol had local ethics committee approval; written informed consent was obtained. There were 125 patients (45 women, 80 men; mean age, 59.9 years +/- 12.9 [standard deviation]; 79 receiving beta-blockers) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating. Data sets were reconstructed in 5% steps from 20% to 80% of R-R interval. Heart rate variability was calculated as 1 standard deviation from mean rate during scanning. Two observers rated image quality of each coronary segment at least 1.5-mm diameter (1 = no motion artifacts, 5 = not evaluative). Repeated analysis of variance measurements were performed to evaluate quantitative parameters. Pearson correlation analysis was performed to compare image quality in each patient with average heart rate and heart rate variability. RESULTS: Average heart rate was 63.3 beats per minute +/- 13.1, with variability of 3.2 beats per minute +/- 2.1. Diagnostic image quality (score < or = 3) was attained in 1821 of 1836 segments at the best reconstruction interval. There was no correlation between mean heart rate and image quality for all segments of the right coronary and left anterior descending arteries, but there was a significant correlation for left circumflex artery (r = 0.33, P < .05). Heart rate variability was correlated with image quality overall (r = 0.75, P < .001) and for each coronary artery. Heart rate was less variable and image quality was better (P < .05) in patients receiving beta-blockers. Best image quality was obtained in diastole with heart rate less than 80 beats per minute and in systole with faster heart rate. CONCLUSION: Coronary angiography with 64-section CT provides diagnostic image quality within a wide range of heart rates. Reducing average heart rate and heart rate variability is beneficial for reducing artifacts.

Adult↗

Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT.

PURPOSE: To evaluate the use of CT attenuation maps, generated from coronary calcium scoring (CCS) scans at in- and expiration with a 64-slice CT scanner, for attenuation correction (AC) of myocardial perfusion SPECT images. METHODS: Thirty-two consecutive patients underwent( 99m)Tc-tetrofosmin gated adenosine stress/rest SPECT scan on an Infinia Hawkeye SPECT-CT device (GE Medical Systems) followed by CCS and CT angiography on a 64-slice CT. AC of the iteratively reconstructed images was performed with AC maps obtained: (a) from the "Hawkeye" low-resolution X-ray CT facility attached to the Infinia camera (IRAC); (b) from the CCS scan acquired on a 64-slice CT scanner during maximal inspiration (AC(INSP)) and (c) during normal expiration (AC(EXP)). Automatically determined uptake values of stress scans (QPS, Cedars Medical Sinai) from AC(INSP) and AC(EXP) were compared with IRAC. Agatston score (AS) values using AC(INSP)versus AC(EXP) were also compared. RESULTS: AC(INSP) and AC(EXP) resulted in identical findings versus IRAC by visual analysis. A good correlation for uptake values between IRAC and AC(INSP) was found (apex, r=0.92; anterior, r=0.85; septal, r=0.91; lateral, r=0.86; inferior, r=0.90; all p<0.0001). The correlation was even closer between IRAC and AC(EXP) (apex, r=0.97; anterior, r=0.91; septal, r=0.94; lateral, r=0.92; inferior, r=0.97; all p<0.0001). The mean AS during inspiration (319+/-737) and expiration(317+/-778) was comparable (p=NS). CONCLUSION: Attenuation maps from CCS allow accurate AC of SPECT MPI images. AC(EXP) proved superior to AC(INSP), suggesting that in hybrid scans CCS may be performed during normal expiration to allow its additional use for AC of SPECT MPI.

Adult↗

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT.

The reconstruction intervals providing best image quality for non-invasive coronary angiography with 64-slice computed tomography (CT) were evaluated. Contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT coronary angiography was performed in 80 patients (47 male, 33 female; mean age 62.1+/-10.6 years). Thirteen data sets were reconstructed in 5% increments from 20 to 80% of the R-R interval. Depending on the average heart rate during scanning, patients were grouped as < 65 bpm (n = 49) and > or = 65 bpm (n = 31). Two blinded and independent readers assessed the image quality of each coronary segment with a diameter > or = 1.5 mm using the following scores: 1, no motion artifacts; 2, minor artifacts; 3, moderate artifacts; 4, severe artifacts; and 5, not evaluative. The average heart rate was 63.3 +/- 13.1 bpm (range 38-102). Acceptable image quality (scores 1-3) was achieved in 99.1% of all coronary segments (1,162/1,172; mean image quality score 1.55 +/- 0.77) in the best reconstruction interval. Best image quality was found at 60% and 65% of the R-R interval for all patients and for each heart rate subgroup, whereas motion artifacts occurred significantly more often (P < 0.01) at other reconstruction intervals. At heart rates < 65 bpm, acceptable image quality was found in all coronary segments at 60%. At heart rates > or = 65 bpm, the whole coronary artery tree could be visualized with acceptable image quality in 87% (27/31) of the patients at 60%, while ten segments in four patients were rated as non-diagnostic (scores 4-5) at any reconstruction interval. In conclusion, 64-slice CT coronary angiography provides best overall image quality in mid-diastole. At heart rates < 65 bpm, diagnostic image quality of all coronary segments can be obtained at a single reconstruction interval of 60%.

Adult↗

Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography.

The purpose of this study was to evaluate the influence of ejection fraction (EF), stroke volume (SV), heart rate, and cardiac output (CO) on coronary artery opacification with 64-slice computed tomography (CT). Sixty patients underwent, retrospectively, electrocardiography-gated 64-slice CT coronary angiography. Left ventricular EF, SV, and CO were calculated with semi-automated software. Attenuation values were measured and contrast-to-noise ratios (CNRs) were calculated in the proximal right coronary artery (RCA) and left main artery (LMA). Mean EF during scanning was 61.5+/-12.4%, SV was 63.2+/-15.6 ml, heart rate was 62.5+/-11.8 beats per minute (bpm), and CO was 3.88+/-1.06 l/min. There was no significant correlation between the EF and heart rate and the attenuation and CNR in either coronary artery. A significant negative correlation was found in both arteries between SV and attenuation (RCA r=-0.26, P<0.05; LMA r=-0.34, P<0.01) and between SV and CNR (RCA r=-0.26, P<0.05; LMA r=-0.26, P<0.05). Similarly, a significant negative correlation was found between the CO and attenuation (RCA r=-0.42, P<0.05; LMA r=-0.56, P<0.001) and between the CO and CNR (RCA r=-0.39, P<0.05; LMA r=-0.44, P<0.001). The actual hemodynamic status of the patient influences the coronary artery opacification with 64-slice CT, in that vessel opacification decreases as SV and CO increase.

Adult↗

Thick maximum intensity projections for the assessment of left ventricular function with 64-slice computed tomography.

OBJECTIVE: The objective of this study was to assess the accuracy of thick maximum intensity projections (MIP) from computed tomography (CT) data sets mimicking projection images from biplane ventriculography for evaluation of left ventricular (LV) parameters. MATERIALS AND METHODS: Fifty-eight patients underwent 64-slice CT. Multiphase images were reconstructed in 10% steps of the RR interval. MIP images (70-mm thickness) of the contrast-enhanced LV in fixed 30 degrees right anterior oblique (RAO)/60 degrees left anterior oblique (LAO) and in adapted short-/long-axis planes were reconstructed. LV parameters were calculated using the area-length method formula. Three-dimensional assessment with semiautomated software served as reference standard. RESULTS: Use of thick MIP reconstructions had a high intermethod reliability (86-94%) compared with the 3-dimensional approach. Smaller measurement errors were found for thick MIP reconstructions in adapted short-/long-axis planes. A significant projection error (3.0%, P < 0.001) of thick MIP reconstructions was found using fixed 30 degrees RAO/60 degrees LAO compared with adapted short-/long-axis reconstructions. CONCLUSION: Thick MIP reconstructions with adapted short-/long-axis planes allow an accurate assessment of LV parameters compared with the established 3-dimensional method.

Adult↗

Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function.

UNLABELLED: Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by electrocardiographically gated 64-slice CT versus gated-SPECT. METHODS: Sixty patients (mean age, 64 +/- 8 y) referred for evaluation of coronary artery disease underwent 99mTc-tetrofosmin gated SPECT and 64-slice CT within 4 +/- 2 d. LV ejection fraction (LVEF), end-systolic volume (ESV), and end-diastolic volume (EDV) from CT were compared with SPECT. Additionally, LV muscle mass and quantitative regional wall motion were assessed in 20 patients with both methods. RESULTS: CT was in good agreement with SPECT for quantification of LVEF (r = 0.825), EDV (r = 0.898), and ESV (r = 0.956; all P < 0.0001). LVEF was 59% +/- 13% measured by SPECT and slightly higher but not significantly different by CT (60% +/- 12%; mean difference compared with SPECT, 1.1% +/- 1.7%; P = not significant). A systematic overestimation using CT for EDV (147 +/- 60 mL vs. 113 +/- 52 mL; mean difference, 33.5 +/- 23.1 mL) and ESV (63 +/- 55 mL vs. 53 +/- 49 mL; mean difference, 9.3 +/- 15.9 mL; P < 0.0001) was found compared with SPECT. A good correlation for muscle mass was found between the 2 methods (r = 0.868; P < 0.005). However, muscle mass calculated by SPECT was significantly lower compared with CT (127 +/- 24 g vs. 148 +/- 37 g; mean difference, 23.0 +/- 12.2 g; P < 0.001). The correlation for regional wall motion between the 2 methods was moderate (r = 0.648; P < 0.0001). CONCLUSION: LVEF and LV functional parameters as determined by 64-slice CT agree over a wide range of clinically relevant values with gated SPECT. However, interchangeable use of the 2 techniques should be avoided for LV volumes, muscle mass, and regional wall motion because of variances inherent to the different techniques.

Adult↗

Repeatability of cold pressor test-induced flow increase assessed with H(2)(15)O and PET.

UNLABELLED: The aim of this study was to evaluate the repeatability of endothelium-related myocardial blood flow (MBF) responses to cold pressor testing (CPT) as assessed by PET. METHODS: In 10 age-matched control subjects (26.6 +/- 3.4 y) and 10 tobacco smokers (24.9 +/- 3.3 y) MBF was assessed at rest and after repeated CPT (CPT1 and CPT2, 40 min apart) using PET with H(2)(15)O. CPT was performed by a 2-min immersion of the subject's foot in ice water. MBF values were corrected for cardiac workload (rate.pressure product), and the repeatability of CPT-related MBF values was assessed according to Bland and Altman. RESULTS: Corrected MBF at CPT1 and CPT2 were comparable in control subjects (1.79 +/- 0.37 vs. 1.70 +/- 0.35 mL/min/g; P = not significant [NS]) and in smokers (1.97 +/- 0.42 vs. 1.80 +/- 0.41 mL/min/g; P = NS). Repeatability coefficients in control subjects and smokers were 0.46 mL/min/g (27% of the mean MBF) and 0.51 mL/min/g (27%), respectively. MBF increased significantly after CPT in both groups but tended to be lower in smokers (P = 0.08). CONCLUSION: PET measured MBF combined with CPT is a feasible and repeatable method for the evaluation of endothelium-related changes of MBF.

Adult↗

Caffeine decreases exercise-induced myocardial flow reserve.

OBJECTIVES: We studied the acute effect of caffeine on myocardial blood flow (MBF) at rest and exercise in healthy volunteers at normoxia and during acute exposure to simulated altitude. BACKGROUND: Caffeine is a widely consumed stimulant, although its cardiovascular safety remains controversial and its effect on MBF is unknown. METHODS: 15O-labeled H2O and positron emission tomography (PET) were used to measure regional MBF at rest and immediately after supine bicycle exercise in healthy volunteers at normoxia (n = 10; mean workload, 175 W; 98% predicted; mean age, 27 +/- 6 years) as well as during hypoxia, simulating an altitude of 4,500 m by inhalation of a mixture of 12.5% oxygen (n = 8; 148 W; 78% predicted; mean age, 29 +/- 4 years). Measurements were repeated 50 min after oral ingestion of caffeine (200 mg). Myocardial flow reserve (MFR) was calculated as the ratio of hyperemic to resting MBF. RESULTS: Resting MBF was not affected by caffeine at normoxia (1.05 +/- 0.36 ml/min/g vs. 1.17 +/- 0.27 ml/min/g; p = NS), although it was significantly increased at hypoxia (1.71 +/- 0.41 ml/min/g vs. 2.22 +/- 0.49 ml/min/g; p < 0.001). By contrast, exercise-induced hyperemic MBF decreased significantly at normoxia (2.51 +/- 0.58 ml/min/g vs. 2.15 +/- 0.47 ml/min/g; p < 0.05) and hypoxia (5.15 +/- 0.79 ml/min/g vs. 3.98 +/- 0.83 ml/min/g; p < 0.005 vs. baseline; p < 0.005 vs. normoxia). The MFR decreased by 22% at normoxia (2.53 +/- 0.69 to 1.90 +/- 0.49; p < 0.01) and by 39% at hypoxia (3.13 +/- 0.60 to 1.87 +/- 0.45, p < 0.005; p < 0.05 vs. normoxia). CONCLUSIONS: In healthy volunteers, a caffeine dose corresponding to two cups of coffee (200 mg) significantly decreased exercise-induced MFR at normoxia and was even more pronounced during exposure to altitude.

Adult↗

18F-choline images murine atherosclerotic plaques ex vivo.

OBJECTIVE: Current imaging modalities of atherosclerosis mainly visualize plaque morphology. Valuable insight into plaque biology was achieved by visualizing enhanced metabolism in plaque-derived macrophages using 18F-fluorodeoxyglucose (18F-FDG). Similarly, enhanced uptake of 18F-fluorocholine (18F-FCH) was associated with macrophages surrounding an abscess. As macrophages are important determinants of plaque vulnerability, we tested 18F-FCH for plaque imaging. METHODS AND RESULTS: We injected 18F-FCH (n=5) or 18F-FDG (n=5) intravenously into atherosclerotic apolipoprotein E-deficient mice. En face measurements of aortae isolated 20 minutes after 18F-FCH injections demonstrated an excellent correlation between fat stainings and autoradiographies (r=0.842, P<0.0001), achieving a sensitivity of 84% to detect plaques by 18F-FCH. In contrast, radiotracer uptake 20 minutes after 18F-FDG injections correlated less with en face fat stainings (r=0.261, P<0.05), reaching a sensitivity of 64%. Histological analyses of cross-sections 20 minutes after coinjections of 18F-FCH and 14C-FDG (n=3) showed that 18F-FCH uptake correlated better with fat staining (r=0.740, P<0.0001) and macrophage-positive areas (r=0.740, P<0.0001) than 14C-FDG (fat: r=0.236, P=0.29 and CD68 staining: r=0.352, P=0.11), respectively. CONCLUSIONS: 18F-FCH identifies murine plaques better than 18F-FDG using ex vivo imaging. Enhanced 18F-FCH uptake into macrophages may render this tracer a promising candidate for imaging plaques in patients.

Animals↗

The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.

OBJECTIVES: We sought to test whether myocardial blood flow (MBF) can be quantified by myocardial contrast echocardiography (MCE) using a volumetric model of ultrasound contrast agent (UCA) kinetics for the description of refill curves after ultrasound-induced microsphere destruction. BACKGROUND: Absolute myocardial perfusion or MBF (ml.min(-1).g(-1)) is the gold standard to assess myocardial blood supply, and so far it could not be obtained by ultrasound. METHODS: The volumetric model yielded MBF = rBV.beta/rho(T), where rho(T) equals tissue density. The relative myocardial blood volume rBV and its exchange frequency beta were derived from UCA refill sequences. Healthy volunteers underwent MCE and positron emission tomography (PET) at rest (group I: n = 15; group II: n = 5) and during adenosine-induced hyperemia (group II). Fifteen patients with coronary artery disease underwent simultaneous MCE and intracoronary Doppler measurements before and during intracoronary adenosine injection. RESULTS: In vitro experiments confirmed the volumetric model and the reliable determination of rBV and beta for physiologic flow velocities. In group I, 187 of 240 segments were analyzable by MCE, and a linear relation was found between MCE and PET perfusion data (y = 0.899x + 0.079; r(2) = 0.88). In group II, resting and hyperemic perfusion data showed good agreement between MCE and PET (y = 1.011x + 0.124; r(2) = 0.92). In patients, coronary stenosis varied between 0% to 89%, and myocardial perfusion reserve was in good agreement with coronary flow velocity reserve (y = 0.92x + 0.14; r(2) = 0.73). CONCLUSIONS: The volumetric model of UCA kinetics allows the quantification of MBF in humans using MCE and provides the basis for the noninvasive and quantitative assessment of coronary artery disease.

Adenosine↗

Assessment of the long-term reproducibility of baseline and dobutamine-induced myocardial blood flow in patients with stable coronary artery disease.

UNLABELLED: Although physical exercise is the preferred stimulus for cardiac stress testing, pharmacologic agents are useful in patients who are unable to exercise. Previous studies have demonstrated short-term repeatability of exercise and adenosine stress, but little data exist regarding dobutamine (Dob) stress or the long-term reproducibility of pharmacologic stressors in coronary artery disease (CAD) patients. PET allows accurate, noninvasive quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR). The aim of the study was to investigate the long-term reproducibility of Dob stress on MBF and CFR in CAD patients using PET. METHODS: Fifteen patients with chronic stable angina and angiographically proven CAD (>70% stenosis in at least 1 major coronary artery) underwent PET with (15)O-labeled water and Dob stress at baseline (time [t] = 0) and after 24 wk (t = 24). MBF at rest and MBF during Dob stress were calculated for the whole left ventricle, the region subtended by the most severe coronary artery stenosis (Isc), and remote myocardium subtended by arteries with minimal or no disease (Rem). Reproducibility was assessed using the Bland-Altman (BA) repeatability coefficient and was also expressed as a percentage of the mean value of the 2 measurements (%BA). RESULTS: Dob dose (30 +/- 11 vs. 031 +/- 11 microg/kg/min; P = not significant [ns]) and peak Dob rate.pressure product (20,738 +/- 3,947 vs. 20,047 +/- 3,455 mm Hg x beats/min; P = ns) were comparable at t = 0 and t = 24. There was no significant difference in resting or Dob MBF (mL/min/g) between t = 0 and t = 24 for the whole left ventricle (1.03 +/- 0.19 vs. 1.10 +/- 0.20 and 2.02 +/- 0.44 vs. 2.09 +/- 0.57; P = ns for both), Isc (1.05 +/- 0.24 vs. 1.10 +/- 0.26 and 1.79 +/- 0.53 vs. 1.84 +/- 0.62; P = ns for both), or Rem (1.03 +/- 0.23 vs. 1.10 +/- 0.26 and 2.27 +/- 0.63 vs. 2.26 +/- 0.63; P = ns for both) territories. Global (1.98 +/- 0.40 vs. 1.90 +/- 0.46; P = ns) and regional CFR (Isc: 1.65 +/- 0.40 vs. 1.67 +/- 0.47, and Rem: 2.25 +/- 0.57 vs. 2.06 +/- 0.51; P = ns) were reproducible. The BA repeatability coefficients (and %BA) for MBF in ischemic and remote territories were 0.3 (28%) and 0.26 (24%) at rest and 0.49 (27%) and 0.58 (26%) during Dob stress. CONCLUSION: In patients with clinically stable CAD, Dob induces reproducible changes in both global and regional MBF and CFR over a time interval of 24 wk. The reproducibility of MBF and CFR with Dob was comparable with the short-term repeatability reported for adenosine and physical exercise in healthy subjects.

Angina, Unstable↗

Integrated PET/CT for the assessment of coronary artery disease: a feasibility study.

UNLABELLED: An accurate, noninvasive technique for the diagnosis of coronary artery disease (CAD) should provide complementary information on coronary anatomy and pathophysiologic lesion severity. We present, what is to our knowledge, the first clinical evaluation of integrated PET/CT for combined acquisition of coronary anatomy and perfusion. METHODS: On an integrated PET/CT scanner, contrast-enhanced CT angiography (CTA) and rest/adenosine-stress myocardial perfusion scanning with (13)N-ammonia were performed on 25 patients with CAD documented by coronary angiography. Contrast-enhanced CTA was performed with retrospective electrocardiography gating after injection of 150 mL of intravenous contrast medium. Decisions on whether to treat with revascularization (anatomic lesion plus ischemia) or conservatively (no lesion or no ischemia) based on PET/CT were compared with those based on PET plus coronary angiography. RESULTS: Of the 100 coronary artery segments (left main, left anterior descending, left circumflex, and right in 25 patients), 7 (in 5 patients) were considered impossible to evaluate by CT because of rapid vessel movement but were correctly categorized by PET alone. In the remaining 93 segments, the sensitivity and specificity of PET/CT versus PET plus coronary angiography were 90% and 98%, respectively. Positive and negative predictive values were 82% and 99%, and accuracy was 97%. CONCLUSION: The data of this preliminary study suggest that PET/CT allows accurate noninvasive clinical decision making about CAD. Because of its high negative predictive value, PET/CT may play an important role in noninvasive selection of CAD patients for revascularization. Integration of higher-performance multislice spiral CT scanners into PET/CT hybrids will accelerate the clinical implementation of this technique.

Adult↗