PubMed Health⌕ Search

Biomedical subjects

Philipp Angenendt

Publications and source records attributed to Philipp Angenendt.

11 recordsLinked to original sources

Progress in protein and antibody microarray technology.

The success of genome sequencing projects has led to a shift from the description of single molecules to the characterisation of complex samples. At the same time, there is growing interest not only in studying organisms at the genomic level, but in the characterization of their proteome. Such a task would not be possible without the availability of appropriate technologies. Protein and antibody microarray technologies are, in addition to two-dimensional gel electrophoresis followed by mass spectrometry, two of the most propitious technologies for the screening of complex protein samples. Nevertheless, to succeed, protein and antibody microarrays have to overcome their current limitations. This review aims to introduce these new technologies and highlights their current prospects and limitations.

Antibodies↗

Subnanoliter enzymatic assays on microarrays.

Many areas of research today are based on enzymatic assays most of which are still performed as enzyme-linked immunosorbent assays in microtiter plates. The demand for highly parallel screening of thousands of samples eventually led to a miniaturization and automation of these assays. However, the final transfer of enzymatic assays from a microtiter-based technology to microarrays has proven to be difficult for various reasons, such as the inability to maintain unbound reaction products on the spot of reaction or the missing capability of multiplexing. Here, we have conducted multiplex enzymatic assays in subnanoliter volumes on a single microarray using the multiple spotting technology. We were able to measure enzymatic activity with a sensitivity down to 35 enzyme molecules, applying only conventional flat microarray surfaces and standard microarray hardware. We have performed assays of inhibition and applied this format for the detection of prognostic markers, such as cathepsin D. The new approach allows the rapid and multiplex screening of thousands of samples on a single microarray with applications in drug screening, metagenomics, and high-throughput enzyme assays.

Alkaline Phosphatase↗

Bacterial protein microarrays for identification of new potential diagnostic markers for Neisseria meningitidis infections.

Neisseria meningitidis is the most common cause of meningitis and causes epidemic outbreaks. One trait of N. meningitidis, which is associated with most of the currently recognized virulence determinants, is the presence of phase-variable genes that are suspected to enhance its ability to cause an invasive disease. To detect the immune responses to phase-variable expressed proteins, we applied protein microarray technology for the screening of meningitis patient sera. We amplified all 102 known phase-variable genes from N. meningitidis serogroup B strain MC58 by polymerase chain reaction and subcloned them for expression in Escherichia coli. With this approach, we were able to express and purify 67 recombinant proteins representing 66% of the annotated genes. These were spotted robotically onto coated glass slides to generate protein microarrays, which were screened using 20 sera of patients suffering from meningitis, as well as healthy controls. From these screening experiments, 47 proteins emerged as immunogenic, exhibiting a variable degree of seroreactivity with some of the patient sera. Nine proteins elicited an immune response in more than three patients, with one of them, the phase-variable opacity protein OpaV (NMB0442), showing responses in 11 patient sera. This is the first time that protein microarray technology has been applied for the investigation of genetic phase variation in pathogens. The identification of disease-specific proteins is a significant target in biomedical research, as such proteins may have medical, diagnostic, and commercial potential as disease markers.

Bacterial Proteins↗

Multiplex approaches in protein microarray technology.

The success of genome sequencing projects has provided the basis for systematic analysis of protein function and has led to a shift from the description of single molecules to the characterization of complex samples. Such a task would not be possible without the provision of appropriate high-throughput technologies, such as protein microarray technology. In addition, the increasing number of samples necessitates the adaptation of such technologies to a multiplex format. This review will discuss protein microarray technology in the context of multiplex analysis and highlight its current prospects and limitations.

Animals↗

Seeing better through a MIST: evaluation of monoclonal recombinant antibody fragments on microarrays.

Automation is the key approach for genomewide and proteomewide screening of function and interaction. Especially for proteomics, antibody microarrays are a useful tool for massive parallel profiling of complex samples. To meet the requirements of antibody microarrays and to obtain a great variety of antibodies, new technologies such as phage display have partly replaced the classical hybridoma method. While the selection process for phage-displayed antibody fragments itself has been automated, the bottleneck was shifted further downstream to the identification of monoclonal binders obtained from the selections. Here, we present a new approach to reduce time, material, and waste to extend automation beyond the selection process by application of conventional microarray machinery. We were able to express recombinant antibody fragments in a single inoculation and expression step and subjected them without purification directly to an automated high-throughput screening procedure based on the multiple spotting technique (MIST). While obtaining comparable sensitivities to enzyme-linked immunosorbent assays, we minimized manual interaction steps and streamlined the technique to be accessible within the automated selection procedure.

Antibodies, Monoclonal↗

Cell-free protein expression and functional assay in nanowell chip format.

The expression and characterization of large protein libraries requires high-throughput tools for rapid and cost-effective expression and screening. A promising tool to meet these requirements is miniaturized high-density plates in chip format, consisting of an array of wells with submicroliter volumes. Here, we show the combination of nanowell chip technology and cell-free transcription and translation of proteins. Using piezoelectric dispensers, we transferred proteins into nanowells down to volumes of 100 nL and successfully detected fluorescence using confocal laser scanning. Moreover, we showed cell-free expression of proteins on a nanoliter scale using commercially available coupled transcription and translation systems. To reduce costs, we demonstrated the feasibility of diluting the coupled in vitro transcription and translation mix prior to expression. Additionally, we present an enzymatic inhibition assay in nanowells to anticipate further applications, such as the high-throughput screening of drug candidates or the identification of novel enzymes for biotechnology.

Cell-Free System↗

Evaluation of antibodies and microarray coatings as a prerequisite for the generation of optimized antibody microarrays.

Antibody microarrays are becoming a major tool for the parallel analysis of complex samples. So far, many efforts have been made to increase the complexity and sensitivity of antibody microarrays. In contrast to enzyme-linked immunosorbent assay (ELISA) experiments, not all antibodies remain functional in the microarray format. Sensitivity is very much dependent on the type of coating and its application. The method described in this chapter is a quick and reliable method that has been very useful in determining the functionality of antibodies and the suitability of coatings for antibody microarrays. At the same time, a detailed description of how to prepare an inexpensive and highly efficient antibody microarray surface is given.

Animals↗

Protein and antibody microarray technology.

Following the age of genomics having sequenced the human genome, interest is shifted towards the function of genes. This new age of proteomics brings about a change of methods to study the properties of gene products on a large scale. Protein separation technologies are now applied to allow high-throughput purification and characterisation of proteins. Two-dimensional-gel electrophoresis (2DE) and mass spectrometry (MS) have become widely used tools in the field of proteomics. At the same time, protein and antibody microarrays have been developed as successor of DNA microarrays to soon allow the proteome-wide screening of protein function in parallel. This review is aimed to introduce this new technology and to highlight its current prospects and limitations.

Antibodies↗

3D protein microarrays: performing multiplex immunoassays on a single chip.

The enzyme-linked immunosorbent assay (ELISA) is typically applied in the format of microtiter plates. To increase throughput and reduce consumption of precious samples, efforts have been made to transfer ELISA to the microchip format using conventional microarrays, microfluidic systems, and chips bearing microwells. However, all three formats lack the possibility to screen several analytes on several immobilized binders at a time or require complicated liquid handling, surface modifications, and additional equipment. Here, we describe an immunoassay performed on a standard microscope slide without the requirement for wells or tubes to separate the samples using standard surfaces and machinery already available for microarray technology. The new multiple spotting technique (MIST) comprises immobilization of a binder onto a surface and subsequent spotting of the second compound on the same spot, on top of the immobilized binder. We show that the analytes bind their ligands immediately within the confined space of separate droplets on the chip surface, thereby eliminating the need for extra incubation time. We illustrate the feasibility of the new technique by spotting dilution rows of proteins or monoclonal and polyclonal antibodies on top of their immobilized binders. Moreover, we demonstrate specificity by applying a mixture of antibodies in a multiplex format and demonstrate that the technique is compatible with conventional microarray protocols, such as total incubation. Finally, we indicate that the technique is capable of quantifying as little as 400 zmol (240,000 molecules) of analyte.

Antibodies↗

Next generation of protein microarray support materials: evaluation for protein and antibody microarray applications.

The performance of protein and antibody microarrays is dependent on various factors, one of which is the use of an appropriate microarray surface for the immobilisation of either protein or antibody samples. We have investigated the properties of seven new surfaces in the context of both protein and antibody microarray technology. We have demonstrated the functionality of all new slide coatings and investigated the mean signal to spotted concentration ratio, determined detection limits and calculated coefficients of variation. Moreover, new concepts for slide coatings such as dendrimer and poly(ethylene glycol)-epoxy slides were evaluated and improved qualities of novel slide surfaces were observed. Optimal slide coatings for antibody and protein chips were proposed and the requirements for both technologies were discussed.

Antibodies↗

Toward optimized antibody microarrays: a comparison of current microarray support materials.

With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.

Acrylic Resins↗