PubMed Health⌕ Search

Biomedical subjects

Philipp Schuch

Publications and source records attributed to Philipp Schuch.

2 recordsLinked to original sources

Long-term neurocognitive function after mechanical aortic valve replacement.

BACKGROUND: Mechanical aortic valves are a possible source of microemboli potentially causing cerebral injury. Therefore, the long-term impact of mechanical aortic valve replacement on neurocognitive function is uncertain. METHODS: In this prospective, contemporary study, we followed 32 consecutive patients (aged 51 +/- 8 years; range, 38 to 70; EuroSCORE [European System for Cardiac Operative Risk Evaluation] 4.4 +/- 1.7) undergoing isolated aortic valve replacement with a mechanical prosthesis. A cohort of age- and sex-matched patients (n = 28, aged 50 +/- 7 years) served as nonsurgical controls. After aortic valve replacement, neurocognitive function was serially reevaluated at 7-day (n = 32), 4-month (n = 31), and 3-year (n = 29) follow-up. Neurocognitive function was measured by means of P300 auditory evoked potentials. RESULTS: Before the operation, P300 peak latencies were comparable between surgical patients (361 +/- 32 ms) and nonsurgical controls (365 +/- 33 ms, p = 0.783). In patients undergoing aortic valve replacement, P300 peak latencies were prolonged 7 days after surgery (380 +/- 32 ms) as compared with before the operation (361 +/- 32 ms, p < 0.0001) and as compared with nonsurgical controls (364 +/- 34 ms, p = 0.002). At 4-month (369 +/- 30 ms, p = 0.752) and 3-year (370 +/- 31 ms, p = 0.825) follow-up, P300 peak latencies normalized as compared with before operation and as compared with nonsurgical controls (4-month follow-up 363 +/- 31 ms, p = 0.832; 3-year follow-up 366 +/- 32 ms, p = 0.432). We found no difference in patients with different valve types. CONCLUSIONS: Despite previous assumptions based on the potential occurrence of microemboli in patients with mechanical valves, mechanical aortic valve replacement has no adverse long-term impact on neurocognitive function. This finding is only valid for patients with a comparable age range undergoing isolated aortic valve replacement.

Adult↗

Neurocognitive deficit following coronary artery bypass grafting: a prospective study of surgical patients and nonsurgical controls.

BACKGROUND: To objectively measure long-term neurocognitive deficit in patients undergoing coronary artery bypass grafting and compare the findings with nonsurgical controls. METHODS: We prospectively measured neurocognitive function in patients undergoing coronary artery bypass grafting (CABG) with cardiopulmonary bypass (n = 104; mean age 64.1 years old; EuroSCORE 2.7 [means]). A cohort of age- and sex-matched patients (n = 80; mean age 63.4 years old) served as nonsurgical controls. After CABG, neurocognitive function was serially reevaluated at 7-day (n = 104), 4-month (n = 100), and 3-year follow-up (n = 88). Neurocognitive function was objectively measured by means of cognitive P300 evoked potentials. Additionally, standard psychometric tests were performed (Trailmaking Test A, Mini Mental State Examination). RESULTS: As compared to preoperative measures (364 +/- 36 ms), cognitive P300 evoked potentials were prolonged (=impaired) at 7-day (381 +/- 36 ms; p = 0.001), 4-month (378 +/- 31 ms; p = 0.08), and 3-year follow-up (379 +/- 35 ms; p = 0.002), respectively. Trailmaking Test A was abnormal, as compared to preoperative, at 3-year follow-up (p < 0.001). Before the operation, surgical patients were fully comparable in P300 measures to nonsurgical controls (363 +/- 32 ms; p = 0.362). Most importantly, throughout the entire postoperative follow-up cognitive measures in surgical patients were prolonged (=impaired) as compared with controls (7-day p = 0.001; 4-month p = 0.002 and 3-year p = 0.003, respectively). In stepwise multivariate regression analysis, neurocognitive deficit at 4-month follow-up (p < 0.001), age (p = 0.012), and persistent atrial fibrillation (p = 0.024) were predictive for long-term neurocognitive deficit at 3-year follow-up. CONCLUSIONS: As shown by means of objective measures, and in comparison to nonsurgical controls, coronary artery bypass grafting with cardiopulmonary bypass grafting causes long-term neurocognitive deficit.

Aged↗