Below Knee Impact Responses using Cadaveric Specimens.

Knee injuries represent about 10% of all injuries suffered during car crashes. Efforts to assess the injury risk to the posterior cruciate ligament (PCL) have been based on a study available in the literature (Viano et al., 1978), in which only two of the five knees tested had PCL ruptures. The aims of the current study were to repeat the study with a higher number of samples, study the effects of other soft tissues on knee response, and assess the adequacy of the experimental setup for the identification of a PCL tolerance. A total of 14 knees were tested using a high-speed materials testing machine. Eight were intact knees (with the patella and all the muscular and ligamentous structures), three were PCL-only knees (patella and all the muscular and ligamentous structures other than the PCL removed), and the last three were PCL-only knees with the tibia protected from bending fracture. Of the eight intact knees tested, only one had PCL mid substance rupture, one had a partial articular fracture of the tibia below the plateau, and six had simple transverse fracture of the tibial metaphysis. Of the three PCL-only knees without tibial protection, one had PCL mid substance rupture, one had avulsion at the posterior intercondylar attachment point, and the last one had a simple oblique fracture of the tibial metaphysis. Of the three PCL only knees with tibia protection, two had PCL mid-substance ruptures and the third one had an avulsion at the tibial insertion site with partial articular fracture of the lateral plateau. Overall, the results of the current study were similar to those observed by Viano et al. (1978). The average displacement at failure for all PCL related injuries was 17.2+/-2.8 mm for the current study (n=6) and 16.2+/-3.9 mm for Viano et al. (1978) (n=4). This value is higher than the Injury Assessment Reference Value of 15 mm proposed by Mertz (1984) and used in various regulations. Both studies suggest that the existence of the soft tissues other than the PCL affect the injury outcome and that the intact knee would suffer predominantly tibial metaphyseal fractures possibly due to bending. Consequently, it is concluded that the current experimental setup can produce isolated PCL injuries but the data available are inadequate to characterize PCL tolerance. A Hybrid III knee equipped with a ball bearing knee slider was also tested using a pendulum setup. Apart from the initial higher stiffness, the overall response of this knee lies within the force-deflection corridors defined using the response of the cadaver knees with PCL mid-substance failure.

Journal Article↗

The influence of surrogate blood vessels on the impact response of a physical model of the brain.

Cerebral blood vessels are an integral part of the brain and may play a role in the response of the brain to impact. The purpose of this study was to quantify the effects of surrogate vessels on the deformation patterns of a physical model of the brain under various impact conditions. Silicone gel and tubing were used as surrogates for brain tissue and blood vessels, respectively. Two aluminum cylinders representing a coronal section of the brain were constructed. One cylinder was filled with silicone gel only, and the other was filled with silicone gel and silicone tubing arranged in the radial direction in the peripheral region. An array of markers was embedded in the gel in both cylinders to facilitate strain calculation via high-speed video analysis. Both cylinders were simultaneously subjected to a combination of linear and angular acceleration using a two-segment pendulum. Marker motion was tracked, and maximum shear strain (MSS) and maximum principal strain (MPS) were calculated using markers clustered in groups of three. Four test series were conducted. Peak angular acceleration varied from 2,600 to 26,000 rad/s2, and peak angular speed varied from 17 to 29 rad/s. For a given impact condition, the test-to-test variation of these values was less than 5.5%. For all clusters, the peak MSS and peak MPS for both physical models were less than 26% and 32%, respectively. For 90% of the cluster locations, the absolute value of the difference in peak MSS and peak MPS between the physical models was 4% and 6%, respectively. In the physical model with tubing, strain tended to decrease in the periphery (near to the tubing), while it tended to increase toward the center (away from the tubing). Strain amplitudes were found to be sensitive to the peak angular speeds. In general, this study suggests that the vasculature could influence the deformation response of the brain.

Journal Article↗

Structural Response of Lower Leg Muscles in Compression: A Low Impact Energy Study Employing Volunteers, Cadavers and the Hybrid III.

Little has been reported in the literature on the compressive properties of muscle. These data are needed for the development of finite element models that address impact of the muscles, especially in the study of pedestrian impact. Tests were conducted to characterize the compressive response of muscle. Volunteers, cadaveric specimens and a Hybrid III dummy were impacted in the posterior and lateral aspect of the lower leg using a free flying pendulum. Volunteer muscles were tested while tensed and relaxed. The effects of muscle tension were found to influence results, especially in posterior leg impacts. Cadaveric response was found to be similar to that of the relaxed volunteer. The resulting data can be used to identify a material law using an inverse method.