PubMed Health⌕ Search

Biomedical subjects

Philippe Otal

Publications and source records attributed to Philippe Otal.

At least 19 recordsLinked to original sources

Endovascular repair of traumatic rupture of the aortic isthmus: midterm results.

OBJECTIVE: The endovascular management of aortic traumatic ruptures has been proposed as an alternative to classical surgical procedures. The aim of this work was to report the midterm results of the endovascular treatment of traumatic ruptures of the isthmic aorta. METHODS: Between January 1996 and July 2005, endovascular repair of blunt traumatic aortic ruptures was performed in 33 patients (mean age, 40 +/- 17 years). The stent grafts used were either Talent Medtronic (n = 27), Gore Excluder (n = 4), or Boston Vanguard (n = 2) grafts. Follow-up was 94.9% complete and averaged 32.4 +/- 28.8 months (maximum, 8 years). RESULTS: Stent graft deployment was successful in all cases without need for surgical conversion. Except for one iliac rupture, which was treated with an iliofemoral bypass during the same procedure, there was no major perioperative complication. The early complications consisted of 3 primary endoleaks (1 type I and 2 type IV), 1 transient paraparesis, 1 occlusion of the main left bronchus, 1 thrombosis, and 2 pseudoaneurysms of the brachial artery. All the primary endoleaks healed within the first month. No patient died, and no aortic reinterventions were performed. The midterm complications were a mild circumferential thrombus at the distal part of the stent graft and a fracture of the nitinol stent. Both complications were asymptomatic and were discovered on systematic computed tomographic scan examination. Actuarial freedom from complication at 1 year was 96.1% +/- 3.8% and 85.5% +/- 10.6% at 3 and 5 years, respectively. CONCLUSION: This study demonstrates that the endovascular treatment of blunt thoracic aortic traumatisms is a safe and effective therapeutic method without increased midterm morbidity and mortality rates.

Adult↗

Midterm results of endovascular treatment of atherosclerotic aneurysms of the descending thoracic aorta.

OBJECTIVE: We sought to determine the midterm results of endovascular repair of atherosclerotic aneurysms of the thoracic descending aorta by using second-generation, commercially available stent grafts. METHODS: Between 1996 and 2005, 45 patients (mean age, 68 +/- 11 years) with aneurysms of the descending thoracic aorta underwent endovascular repair. Aortic dissections, penetrating ulcers, and traumatisms were excluded. The mean follow-up was 24.7 +/- 21.6 months (maximum, 6.7 years). RESULTS: No patients died, and no conversion to surgical intervention was required during the procedures. Three (6.7%) patients died during the first month, and 6 (14.7%) died later on. The main complications were strokes (13.3%), vascular access complications (8.9%), aortic complications (6.6%), paraplegia (4.4%), and sudden deaths (4.4%). Nineteen (42%) primary endoleaks were encountered: 3 required reinterventions, 15 spontaneously thrombosed, and 1 patient died. Except for 2 sudden unexplained deaths, no aortic complications were observed after 1 month. Actuarial survival estimates at 1, 3, and 5 years were 87.6% +/- 5.3%, 76.9% +/- 7.4%, and 70.6% +/- 9.2%, respectively. Actuarial freedom from death related to the treated aortic disease was 94.3% +/- 4.0%, 94.3% +/- 4.0%, and 86.4% +/- 8.4% at 1, 3, and 5 years, respectively. Aspirin status of greater than 3 (P = .005), high aortic diameter (P = .007), and long covered lengths (P = .02) were determinant for mortality. Actuarial freedom from complication was 62.6% +/- 7.7%, 58.9% +/- 8.1%, and 58.9% +/- 8.1% at 1, 3, and 5 years, respectively. The location of the aneurysm (P = .05) and a high aortic diameter (P = .04) were both determinants for endoleaks. CONCLUSIONS: Stent grafting of atherosclerotic aneurysm of the thoracic descending aorta is safe and effective. Further studies are mandatory to determine the most relevant indications and the long-term efficacy of such treatment.

Aged↗

[Colonography].

Explore the source record for details and available documents.

Colonoscopy↗

Midterm results of aortic diameter outcomes after thoracic stent-graft implantation for aortic dissection: a multicenter study.

PURPOSE: To evaluate aortic diameter outcomes after stent-graft implantation for aortic dissection in the descending thoracic aorta. METHODS: Fifty patients with type A dissection after ascending aortic surgery (n = 10), type B dissection (n = 34), or intramural hematoma (n = 6) underwent stent-graft repair in 3 centers. Thrombosis and aortic diameter were analyzed by computed tomographic angiography at different levels of the aorta before stent-graft implantation, at discharge, and at follow-up. Measurements were standardized. RESULTS: In all, 67 stent-grafts were implanted for acute (n = 18) and chronic (n = 32) dissection. Stent-graft placement was successfully performed with high technical success (100%) despite 4 major complications (iliac thrombosis in 2 cases, aortic rupture, and a type A dissection) in 3 (6%) patients. Complete thrombosis of the thoracic false lumen was observed in 42% and 63% of cases at discharge and at follow-up (mean 15 months), respectively. At follow-up, the diameters of the entire aorta (mean 5 mm, p < 0.05) and the false lumen (mean 11 mm, p < 0.0001) decreased. Diameters of the abdominal aorta remained stable in association with persistent false lumen perfusion at this level. Aortic diameter results were better in the subgroup of patients with intramural hematoma compared to patients with Marfan syndrome. Three early deaths unrelated to the stent-graft procedure occurred; 2 patients with partial thrombosis of the false lumen died in follow-up secondary to aortic diameter growth. CONCLUSION: Complete thrombosis of the false lumen by stent-graft coverage of the entry tear results in decreased diameter of the entire aorta. In patients with partial thrombosis of the false lumen, the aneurysm continues to enlarge.

Adult↗

Post-traumatic venous and systemic air embolism associated with spinal epidural emphysema: multi-slice computed tomography diagnosis.

A 30-year-old man was admitted with chest trauma after a road traffic accident. The patient was paraplegic and suffered from transient monoparesia of the left arm. The chest X-ray revealed a severe right tension pneumothorax and thoracic spine fractures. Emergency right thoracic drainage was carried out followed by angiography. Unfortunately the patient died and an autopsy was not permitted. Consequently post-mortem multi-slice computed tomography (MSCT) was performed, revealing presence of air inside the right cerebral arteries, bilateral pneumothorax accompanied by a severe right tension pneumothorax, bilateral haematic pleural effusion, pneumomediastinum and bilateral lung contusions. Air was also observed within the right coronary artery, ascending aorta and right ventricle. Thoracic and cervical spinal epidural emphysema were diagnosed. Venous air embolism followed by arterial air embolism producing paradoxical embolism was diagnosed. To the best of our knowledge, this is the first case illustrating by post-mortem MSCT such simultaneous complications after chest trauma as spinal epidural emphysema and cerebral and coronary air embolism.

Accidents, Traffic↗

Improved clinical outcome using polytetrafluoroethylene-coated stents for TIPS: results of a randomized study.

BACKGROUND & AIMS: A 50% dysfunction rate at 1 year is one of the main drawbacks of the transjugular intrahepatic portosystemic shunt procedure. Preliminary experimental and clinical studies suggest that the use of stents covered with polytetrafluoroethylene could tremendously decrease this risk. METHODS: Eighty patients with cirrhosis and uncontrolled bleeding (n = 23), recurrent bleeding (n = 25), or refractory ascites (n = 32) were randomized to be treated by transjugular intrahepatic portosystemic shunts with either a polytetrafluoroethylene-covered stent (group 1; 39 patients) or a usual uncovered prosthesis (group 2; 41 patients). Follow-up Doppler ultrasound was scheduled at day 7, at 1 month, and then every 3 months for 2 years. Angiography and portosystemic pressure gradient measurements were performed 6, 12, and 24 months after the transjugular intrahepatic portosystemic shunt procedure and whenever dysfunction was suspected. Dysfunction was defined as a >50% reduction of the lumen of the shunt at angiography or a portosystemic pressure gradient >12 mm Hg. RESULTS: After a median follow-up of 300 days, 5 patients (13%) in group 1 and 18 (44%) in group 2 experienced shunt dysfunction (P < 0.001). Clinical relapse occurred in 3 patients (8%) in group 1 and 12 (29%) in group 2 (P < 0.05). Actuarial rates of encephalopathy were 21% in group 1 and 41% in group 2 at 1 year (not significant). Estimated probabilities of survival were 71% and 60% at 1 year and 65% and 41% at 2 years in groups 1 and 2, respectively (not significant). CONCLUSIONS: The use of polytetrafluoroethylene-covered prostheses improves transjugular intrahepatic portosystemic shunt patency and decreases the number of clinical relapses and reinterventions without increasing the risk of encephalopathy.

Adult↗

Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations.

The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean+/-SD value: 34+/-12.9 vs 43+/-13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean+/-SD value: 17+/-2.75 vs 14+/-3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening ( n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%).

Aged↗

Endovascular treatment of acute complications associated with aortic dissection: midterm results from a multicenter study.

PURPOSE: To evaluate endovascular procedures in the management of acute ischemic complications and rupture of the false lumen in aortic dissections. METHODS: Data on patients with aortic dissection and noncardiac acute complications (peripheral ischemia or thoracic aortic rupture) treated with endovascular techniques were collected from 10 institutions and retrospectively analyzed. From March 1997 to January 2000, 58 patients (50 men; mean age 59.6+/-12.8 years) were treated for 19 (33%) type A and 39 (67%) type B dissections. Twelve (21%) patients had thoracic aortic rupture; 46 (79%) patients had one or more peripheral ischemic complications that included bowel pain (19, 41%), anuria associated with acute renal insufficiency (18, 39%), lower limb ischemia (15, 33%), and/or uncontrolled hypertension with renal ischemia (14, 30%). RESULTS: In the thoracic rupture cohort, all 12 patients were treated successfully with stent-grafts; one distal endoleak required a secondary procedure. There were 2 (12%) periprocedural deaths; one patient developed transient paraplegia after a secondary surgical procedure. In the 46 patients treated with stent implantation, fenestration, or both for peripheral ischemic symptoms, 44 (96%) had patency restored to the malperfused vessel. Eight (17%) patients died within 30 days. Over a mean follow-up of 8.2+/-8.9 months, the false lumen had thrombosed in 7 (70%) of the stent-graft patients. In the 38 surviving ischemic patients, the diameters of the true and false lumens and maximum transverse aorta all increased; only 4 (11%) had total thrombosis of the false lumen. CONCLUSIONS: Endovascular treatment of noncardiac acute complications associated with aortic dissection has favorable early and midterm outcomes.

Acute Disease↗

Midterm outcomes of thoracic aortic stent-grafts: complications and imaging techniques.

PURPOSE: To evaluate the midterm outcomes of thoracic aortic stent-grafting and the performance of computed tomographic angiography (CTA), radiography, and magnetic resonance angiography (MRA) in endograft surveillance. METHODS: Forty-seven patients with traumatic thoracic aortic ruptures (n=16), aneurysms (n=14), false aneurysms (n=3), penetrating ulcers (n=3), and dissections (n=11) treated with stent-grafts were monitored in follow-up using chest radiography and CTA in all patients and MRA in 23 patients. Two perpendicular maximal aortic diameters, the sum of these diameters, and the elliptical cross-sectional area were determined and compared to baseline for the entire group and in subgroup analyses according to lesion type. CTA, MRA, and radiography were compared for their ability to detect endoleak, monitor stent-graft configuration, and measure aortic diameters. RESULTS: The mortality rate was 8.5%. Severe complications were observed in 14.8% (6% neurological complications); 12 (25.5%) patients had primary endoleaks. Over a mean 11-month follow-up (range 0.25-46 months), the aortic diameters decreased for all patients without endoleak (p<0.001). In the diameter/area subgroup analyses, only the traumatic rupture cohort demonstrated significant decreases in all 4 measurements. CTA and MRA measurements correlated well, but chest radiography was superior to both for visualizing stent-graft shape. In terms of endoleak detection, MRA missed only 1 (12.5%) endoleak (type II) seen on CTA; there were no false positive results with MRA. CONCLUSIONS: Morbidity and mortality observed after thoracic stent-grafting are acceptable. Radiography is better for monitoring stent-graft conformation, while CTA provides the best overall morphological information. The performance of MRA in endoleak detection is encouraging.

Adolescent↗

Adolescents with partial growth hormone (GH) deficiency develop alterations of body composition after GH discontinuation and require follow-up.

It is now a consensus to resume GH treatment in adolescents with severe GH deficiency (GHD) at retesting to prevent the occurrence of adult GHD syndrome. However, we do not have any data on the follow-up of adolescents with nonsevere GHD at completion of treatment. This report presents preliminary data from a 1-yr prospective study that includes the first 91 patients retested. Anthropometric data, IGF-I and IGF binding protein-3 levels, glycemia and insulinemia, lipid profile, and body composition using dual x-ray absorptiometry and abdominal computed tomography scan were recorded at completion of GH treatment and 1 yr later. Body composition was significantly different at both evaluations, with increased total body fat and decreased lean body mass in the partial GHD group vs. the normal group. Moreover, these alterations worsened after 1 yr without GH in the partial GHD group, whereas there were no modifications in the normal group. We did not find any metabolic alterations such as elevated triglyceride, total cholesterol, or insulin levels. Adolescents with reconfirmed partial GHD exhibit alterations in body composition after 1 yr without GH, whereas those retested normal do not. These changes are similar to those described in severe GHD, although less marked, and justify a precise follow-up.

Abdomen↗

Transjugular intrahepatic portosystemic shunt in the treatment of portal hypertension using memotherm stents: a prospective multicenter study.

PURPOSE: In a prospective multicenter study, efficacy and safety of transjugular intrahepatic portosystemic shunts (TIPS) were evaluated in the treatment of the complications of portal hypertension using a new self-expanding mesh-wire stent (Memotherm). METHODS: One hundred and eighty-one patients suffering from variceal bleeding (either acute or recurrent) or refractory ascites were enrolled. Postinterventional follow-up lasted for 8.4 months on average. Differences were analyzed by the log-rank test (chi-square) or Wilcoxon test. RESULTS: Shunt insertion was completed successfully in all patients (n = 181 patients, 100%). During follow-up, shunt occlusion was evident in 23 patients, and shunt stenosis was found in 33 patients (12.7% and 18.2%, respectively). Variceal rebleeding occurred in 20 of 139 patients (14.4%), with at least one episode of bleeding before TIPS treatment. The overall mortality rate of the patients treated by TIPS was 39.8%. In 51.4% of these cases (37 of 72 patients), however, the patients died within 30 days after TIPS placement. Analysis of subgroups showed that patients who underwent emergency TIPS for acute variceal bleeding had a significantly higher early mortality compared with other patient groups (p = 0.0014). CONCLUSION: In the present prospective multicenter study, we were able to show that insertion of Memotherm stents is an effective tool for TIPS. The occlusion rates seem to be comparable to those reported for the Palmaz stent. It could be shown that in particular, those patients who were treated for acute bleeding were at high risk of early mortality. Consequently, in such a critical condition, the indication for TIPS has to be set carefully.

Adult↗

[Imaging of the aorta].

Imaging of the aorta has greatly been improved by the recent development of helical computed tomography and magnetic resonance imaging. This report develops typical features of variety of aortic diseases including dissections, aneurysms, aortic rupture, non aneurismal atherosclerotic diseases, arteritis, aortic coarctation and postoperative aorta. The place for the different imaging modalities is discussed according to the disease involved.

Aortic Dissection↗

Endovascular treatment of aberrant systemic arterial supply to normal basilar segments of the right lower lobe: case report and review of the literature.

We report the case of a 17-year-old man with acute chest pain due to a partial thrombosis of a pseudosequestration. Unlike a true sequestration, there was a normal bronchial distribution and the involved lung parenchyma was normal on CT scan. A therapeutic transarterial embolization of the aberrant systemic artery from the proximal abdominal aorta was performed successfully. The patient did not suffer from further chest pain during the follow-up of 12 months. A contrast-enhanced CT scan 4 months later demonstrated complete occlusion of the embolized aberrant artery. Our case represents an alternative treatment to surgery for this rare abnormality.

Adolescent↗

A useful endovascular technique for treating modular limb disconnection in a bifurcated stent-graft.

PURPOSE: To report a technique for treating a type III endoleak owing to disconnection of an iliac graft limb from a modular aortic stent-graft. TECHNIQUE: A hydrophilic guidewire is introduced via a homolateral femoral access and passed through the thrombosed iliac extension. Once the errant graft limb is recanalized, wire exchange for an extra stiff guidewire facilitates passage of an angioplasty balloon into the stent. Inflated under low pressure, the balloon is used to push the thrombosed limb retrograde into the aneurysm sac. With the aortoiliac axis restored, a new covered stent can be deployed. CONCLUSIONS: This approach is one of several that may be used to treat a type III endoleak arising from a disconnected and occluded stent-graft limb. It avoids the bleeding complications of thrombolysis and restores the aortoiliac axis so that another stent-graft may be implanted to re-exclude the aneurysm.

Aged↗

Preliminary results of a new expanded-polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt procedures.

OBJECTIVE: The purpose of our study was to evaluate the feasibility and the safety of transjugular intrahepatic portosystemic shunts (TIPS) with a new expanded-polytetrafluoroethylene-covered stent and the influence of the covering on occlusion rate. SUBJECTS AND METHODS: Twenty cirrhotic patients (57 +/- 11 years old) admitted with a history of esophageal variceal bleeding (n = 11), refractory ascites (n = 5), or both (n = 4) were included. Five of the patients were treated for TIPS revision, and 15 as de novo TIPS placements. The endoprostheses used were composed of a 2-cm noncovered nitinol stent and a 4- to 8-cm expanded-polytetrafluoroethylene graft covering, and were placed from the portal vein to the ostium of the hepatic vein. Patients underwent Doppler sonography at discharge and again at 1, 3, 6, 9, 12, and 15 months and underwent venography with portosystemic pressure gradient measurement at 6 months and whenever necessary. RESULTS: At the time of this writing, complications included three TIPS restenoses and one recurrent ascites successfully treated by balloon dilation, two cases of segmentary liver ischemia, and one patient with encephalopathy that required shunt reduction. After TIPS placement, the portosystemic pressure gradient dropped from 18 +/- 5 to 5 +/- 4 mm Hg. Primary and secondary patency rates were 80% and 100%, respectively, at 387 days. CONCLUSION: These results clearly show the feasibility of TIPS placement with the Gore TIPS endoprosthesis stent-graft and its improved patency compared with results in the literature for bare stents. These preliminary results must be certified further with randomized comparative trials between covered and noncovered TIPS stents.

Adult↗

Stent-graft treatment of penetrating thoracic aortic ulcers.

PURPOSE: To evaluate the efficacy of stent-graft placement for the treatment of penetrating thoracic aortic ulcers. METHODS: Ten patients (7 men; mean age 73.8 years, range 69-79) were treated for penetrating thoracic aortic ulcers using Talent or Excluder stent-grafts. Preoperative examinations included computed tomographic angiography (CTA), transesophageal echography, and digital subtraction angiography (DSA). Follow-up included predischarge multimodal imaging and periodic CTA scans after discharge. Endoleaks, aortic diameter changes, and clinical complications were tracked. RESULTS: Technical success was achieved in 100%, but 1 major neurological complication led to death 3 months after the procedure. Radiological follow-up detected 4 early, endoleaks (3 type I and a type II), all of which spontaneously regressed, and 1 secondary type II endoleak. The mean aortic diameter decreased by 22% over a mean 9-month follow-up. CONCLUSIONS: Aortic ulcers are potentially lethal lesions. Considering its low morbidity and mortality, endovascular repair could widen the treatment options for these lesions.

Aged↗