The practical application of three validated in vitro embryotoxicity tests. The report and recommendations of an ECVAM/ZEBET workshop (ECVAM workshop 57).
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Philippe Vanparys.
Explore the source record for details and available documents.
An interlaboratory study was performed to validate an anti-CD71/flow cytometry-based technique for enumerating micronucleated reticulocytes (MN-RETs) in mouse peripheral blood. These experiments were designed to address International Workshop on Genotoxicity Test Procedures validation criteria by evaluating the degree of correspondence between MN-RET measurements generated by flow cytometry (FCM) with those obtained using traditional microscopy-based methods. In addition to these cross-methods data, flow cytometric MN-RET measurements for each blood sample were performed at two separate sites in order to evaluate the reproducibility of data between laboratories. In these studies, groups of male CD-1 mice were treated with vehicle (saline or vegetable oil), a negative control (saline or vegetable oil), or four dose levels of five known genotoxicants (clastogens: cyclophosphamide, benzo[a]pyrene, 5-fluorouracil, methotrexate; aneugen: vincristine sulfate). Exposure occurred on 3 consecutive days via intraperitoneal injection, and blood samples were obtained approximately 24 hr after the final treatment. MN-RET frequencies were determined for each sample based on the analysis of 2,000 (microscopy) and 20,000 (FCM) reticulocytes. Regardless of the method utilized, each genotoxic agent was observed to cause statistically significant increases in the frequency of MN-RETs, and each response occurred in a dose-dependent manner. Spearman's correlation coefficient (rs) for FCM versus microscopy-based MN-RET measurements (nine experiments, 252 paired measurements) was 0.740, indicating a high degree of correspondence between methods. The rs value for all flow cytometric MN-RET measurements performed at the two independent sites was 0.857 (n = 248), suggesting that the automated method is highly transferable between laboratories. Additionally, the flow cytometric system offered advantages relative to microscopy-based scoring, including a greater number of cells analyzed, much faster analysis times, and a greater degree of objectivity. Collectively, data presented in this report suggest that the overall performance of mouse peripheral blood micronucleus tests is enhanced by the use of the flow cytometric scoring procedure.
According to the current Organization of Economic Cooperation and Development (OECD) and International Committee on Harmonization (ICH) guidelines for the mammalian erythrocyte micronucleus (MN) test, analysis of peripheral blood reticulocytes (RETs) for the presence of micronuclei can be performed using flow cytometry. The MicroFlow PLUS method (Litron Laboratories, Rochester, NY) for MN analysis by flow cytometry is based on the binding of FITC-labeled antibodies to the CD71 transferrin receptor of immature RETs, on parallel RNA degradation, and on propidium iodide staining of DNA present as micronuclei. The objective of this study was to assess the sensitivity of this flow cytometry method to detect time- and dose-dependent induction of micronuclei in mouse peripheral blood RETs after treatment with nine chemical agents. Five known clastogens, two known aneugens, and two compounds previously reported to be inactive in the mouse bone marrow MN test were evaluated at three dose levels. Multiple blood sampling of the same animal before and at two time points after treatment was conducted. All known mutagens produced a dose-dependent increase in micronucleated reticulocytes (MN-RETs); the compounds previously shown to be inactive in the in vivo MN test were also negative using the present methodology. The highest frequency of MN-RETs was observed at 48 hr after treatment, except for 5-fluorouracil, which had its peak response at 72 hr. The results indicate that micronuclei can be measured by multiple blood sampling of the same animal before and after treatment without altering the sensitivity of the assay. The results confirm that the flow cytometric assessment of MN-RETs in mouse peripheral blood using MicroFlow PLUS is a sensitive method with high analysis throughput, and robust quality control.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In the pharmaceutical industry, toxicology testing is normally done by preclinical scientists during the Development phase. In the last decade, the implementation of high-throughput screens during the Discovery phase has resulted in an ever-increasing number of lead candidates to be selected for drug development. The low throughput of the conventional safety tests is a bottleneck in the drug-development process. The pharmaceutical industry needs new techniques, down-scaled tests and in vitro alternative test models to determine the absorption, distribution, metabolism, and excretion (ADME) and toxicology profiles of compounds in the late-Discovery phase and/or early in the Development phase. Medium-throughput ADME and toxicity tests will enhance the selection of safer new chemical entities for animals and/or humans. Consequently, this testing strategy will not only reduce the use of resources and the overall development time, but will also result in a substantial decrease in animal use.