Biosensor for rapid determination of 3-hydroxybutyrate using bi-enzyme system.

A bi-enzyme-based Clark electrode was developed for the determination of 3-hydroxybutyrate. This sensor is based on the specific dehydrogenation by 3-hydroxybutyrate dehydrogenase (HBDH, E.C. 1.1.1.30) in combination with salicylate hydroxylase (SHL E.C. 1.14.13.1). The enzymes were entrapped by a poly(carbamoyl) sulfonate (PCS) hydrogel on a Teflon membrane. The principle of the determination scheme is as follows: the specific detecting enzyme, HBDH, catalyses the specific dehydrogenation of 3-hydroxybutyrate consuming NAD(+). The products, NADH, initiate the irreversible decarboxylation and the hydroxylation of salicylate by SHL in the presence of oxygen. SHL forces the equilibrium of dehydrogenation of 3-hydroxybutyrate by HBDH to the product side by consuming NADH. Dissolved oxygen acts as an essential material for SHL during its enzymatic reactions. This results in a detectable signal due to the SHL-enzymatic consumptions of dissolved oxygen in the measurement of 3-hydroxybutyrate. Interferences from different amino acids and electroactive substances were found to be minimal due to the specificity of HBDH and the application of a Teflon membrane. The sensor has a fast response (2s) and short recovery time (2 min) with a linear range between 8 and 800 microM 3-hydroxybutyrate and a detection limit of 3.9 microM. A good agreement (R(2)=0.9925) with theoretical calculation was obtained in spiked serum sample measurements.

3-Hydroxybutyric Acid↗

Amperometric biosensor for determining human salivary phosphate.

An amperometric biosensor was constructed for analysis of human salivary phosphate without sample pretreatment. The biosensor was constructed by immobilizing pyruvate oxidase (PyOD) on a screen-printed electrode. The presence of phosphate in the sample causes the enzymatic generation of hydrogen peroxide (H(2)O(2)), which was monitored by a potentiostat and was in proportion to the concentration of human salivary phosphate. The sensor shows response within 2s after the addition of standard solution or sample and has a short recovery time (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 to 625 microM phosphate with a detection limit of 3.6 microM. A total of 50 salivary samples were collected for the determination of phosphate. A good level of agreement (R(2)=0.9646) was found between a commercial phosphate testing kit and the phosphate sensor. This sensor maintained a high working stability (>85%) after 12h operation and required only a simple operation procedure. The amperometric biosensor using PyOD is a simple and accurate tool for rapid determinations of human salivary phosphate, and it explores the application of biosensors in oral and dental research and diagnosis.

Biosensing Techniques↗

A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater.

A screen-printed phosphate biosensor based on immobilized pyruvate oxidase (PyOD, E.C. 1.2.3.3) has been developed for monitoring phosphate concentrations in a sequencing batch reactor (SBR) system. The enzyme was immobilized by a nafion matrix and covered a poly(carbamoyl) sulfonate (PCS) hydrogel on a screen-printed electrode. PyOD consumes phosphate in the presence of pyruvate and oxygen and generates hydrogen peroxide (H2O2), carbon dioxide and acetylphosphate. The electroactive H2O2, monitored at +420 mV vs Ag/AgCl, is generated in proportion to the concentration of phosphate. The sensor has a fast response time (2 s) and a short recovery period (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 microM to 625 microM phosphate with a detection limit of 3.6 microM. There was good agreement (R2=0.9848) between the commercial phosphate testing kit and the phosphate sensor in measurements of synthetic wastewater in a SBR system. This sensor maintained a high working stability (>85%) after 12 h of operation and involved a simple operation procedure. It therefore serves as a useful tool for rapid and accurate phosphate measurements in the SBR system and probably for process control.

Bioreactors↗

Amperometric determination of lactate with novel trienzyme/poly(carbamoyl) sulfonate hydrogel-based sensor.

A novel trienzyme sensor for the amperometric determination of lactate was constructed by immobilizing salicylate hydroxylase (SHL, E.C. 1.14.13.1), l-lactate dehydrogenase (LDH, E.C. 1.1.1.27), and pyruvate oxidase (PyOD, E.C. 1.2.3.3) on a Clark-type oxygen electrode. The enzymes were entrapped by a poly(carbamoyl) sulfonate (PCS) hydrogel on a Teflon membrane. LDH catalyzes the specific dehydrogenation of lactate consuming NAD(+). SHL catalyzes the irreversible decarboxylation and the hydroxylation of salicylate in the presence of oxygen and NADH produced by LDH. PyOD decarboxylates pyruvate using oxygen and phosphate. SHL and PyOD force the equilibrium of dehydrogenation of lactate by LDH to the product side by consuming NADH and pyruvate, respectively. Dissolved oxygen acts as an essential material for both PyOD and SHL during their respective enzymatic reactions. Therefore, an amplified signal, caused by the consumptions of dissolved oxygen by the two enzymes, was observed in the measurement of lactate. Regeneration of cofactor was found in the trienzyme system. A Teflon membrane was used to fabricate the sensor in order to avoid interferences. The sensor has a fast response (2s) and short recovery times (2 min). The total test time for a measurement by using this lactate sensor (4 min) was faster than using a commercial lactate testing kit (up to 10 min). The sensor has a linear range between 10 and 400 microM lactate, with a detection limit of 4.3 microM. A good agreement (R2 = 0.9984) with a commercial lactate testing kit was obtained in beverage sample measurements.

Biosensing Techniques↗