PubMed Health⌕ Search

Biomedical subjects

Pierluigi Cuomo

Publications and source records attributed to Pierluigi Cuomo.

5 recordsLinked to original sources

Double-bundle "anatomic" anterior cruciate ligament reconstruction: a cadaveric study of tunnel positioning with a transtibial technique.

PURPOSE: The aim of this study was to examine whether a double-bundle anterior cruciate ligament (ACL) reconstruction with a transtibial approach could position the tibial and femoral tunnels accurately in the native bundle attachments. METHODS: In 21 fresh-frozen knees the tibial and femoral attachments of the anteromedial (AM) and posterolateral (PL) bundles were outlined. The AM tibial tunnel guidewire was drilled with the 65 degree Howell tibial guide (Arthrotek, Warsaw, IN) located against the femur in the extended knee. The PL tibial wire was drilled through a prototype attachment to the Howell guide. Of the knees, 14 were available for the femoral part of the study. The AM femoral guidewire used an aimer offset 3 mm from the over-the-top position. The PL wire was drilled transtibially at 70 degrees of flexion, with external rotation and posterior drawer loads being applied. The plateaus and condyles were photographed and the wire positions measured. RESULTS: With regard to the tibia, 17 of 21 AM wires were in the AM bundle attachment (at 61% and 36% of the natural ACL posteroanterior and mediolateral length, respectively) and 19 of 21 PL wires were in the PL bundle attachment (at 28% and 36% of the posteroanterior and mediolateral length, respectively). With regard to the femur, 12 of 14 AM wires and 9 of 14 PL wires were in the correct native bundle attachment. The AM wire was 3% more shallow than the center of the AM attachment (P = .03) and 6% more superior (P < .001), where 100% was the diameter of the posterior lateral condyle. The PL wire was 4% more shallow than the center of the PL attachment (P = .026) and 6% more superior (P < .001). CONCLUSIONS: Anatomic and reproducible tibial guidewire positioning was achieved. Femoral wires were reproducibly positioned, but both were superior to and more shallow than the natural ACL bundle attachments, so further development or a different approach is appropriate. CLINICAL RELEVANCE: The double-bundle reconstruction aims to restore anterior drawer and rotational stability. This technique ensures anatomic tibial positioning. Further improvements are needed with regard to the femur.

Anterior Cruciate Ligament↗

Single-and double-incision double-bundle ACL reconstruction.

Double-bundle anterior cruciate ligament (ACL) reconstruction is intended to replicate the anatomy and the function of the anteromedial and posterolateral bundles of the native ACL to improve patients' satisfaction and knee stability. We prospectively assigned 75 consecutive patients with an isolated ACL lesion to one of three sequential groups of 25 patients each. Group I received a single-bundle, single-incision transtibial ACL reconstruction. Groups II and III received a double-bundle reconstruction with a single-incision transtibial technique or a double-bundle, twoincision outside-in technique, respectively. We obtained subjective International Knee Documentation Committee and Knee Injury and Osteoarthritis Outcome Score evaluations and objective International Knee Documentation Committee scores and KT-1000 measurements preoperatively and at followup. All patients reached a minimum followup of 2 years. KT side-to-side difference in Groups I, II, and III were 2.4, 1.6 and 1.4 mm, respectively. Group III had fewer patients with a positive pivot shift than Group I. The double-bundle double-incision outside-in ACL reconstruction resulted in improved anteroposterior stability and less residual pivot shift than single-incision single-bundle technique.

Adult↗

Validation of the 65 degrees Howell guide for anterior cruciate ligament reconstruction.

PURPOSE: To study in cadaver knees the position of the tibial tunnel in anterior cruciate ligament (ACL) reconstruction using the 65 degrees Howell guide (Arthrotek, Ontario, CA). TYPE OF STUDY: Controlled laboratory study in vitro. METHODS: Twenty-one fresh-frozen cadaver knees were used. The ACL was resected and its tibial attachment was demarcated. To drill the guidewire, we used the Howell 65 degrees tibial guide, which references off of the intercondylar roof in extension to avoid impingement. The intra-articular position of the wire was digitized with a digital camera and referred to a transverse axis passing through the over-the-back position and a sagittal axis passing through the lateral aspect of the medial spine. The percentage position of the wire within the ACL attachment was also calculated, taking the posterior and medial limits as the 0% positions. RESULTS: All the wires were within the ACL attachment: 17 were in the ACL posterolateral bundle attachment and the other 4 in the anteromedial. The average distance of the wire from the transverse and sagittal axes was 12 mm (SD, 3 mm) anterior and 1 mm (SD, 1 mm) lateral, respectively. The wire was positioned at 38% (SD, 16%) of the length of the ACL attachment and at 40% (SD, 17%) of the width. Eighty percent of the wires were positioned at between 35% and 48% of the attachment length. CONCLUSIONS: The 65 degrees Howell guide, which positions the tibial tunnel in extension to avoid roof impingement, ensures anatomic positioning of the graft on the tibial side and reproducibility can be expected. CLINICAL RELEVANCE: This study proves that a commonly used drill guide succeeds in placing the ACL graft in the tibial anatomic attachment.

Anterior Cruciate Ligament↗

Femoral attachment of the anterior cruciate ligament.

Endoscopic anterior cruciate ligament (ACL) reconstruction is one of the most popular orthopaedic procedures. Correct tunnel positioning is a prerequisite to success. Current surgical techniques are unable to duplicate the complex anatomy and function of the native ACL. Surgery mainly aims at restoring anteroposterior laxity. The ACL is not isometric and only a few fibers are nearly isometric over the full range of motion. However, a nearly isometric behaviour of the ACL graft is desirable. Isometry is mainly influenced by femoral attachment; thus the femoral tunnel position has a greater effect than the tibial on graft length changes. The purpose of this article is to describe the anatomy of the femoral ACL insertion and to discuss the surgical techniques used to replicate it.

Anterior Cruciate Ligament↗

Anterior cruciate ligament reconstruction with double-looped semitendinosus and gracilis tendon graft directly fixed to cortical bone: 5-year results.

Forty-three patients who had undergone an anterior cruciate ligament (ACL) reconstruction using a doubled semitendinosus and gracilis graft were prospectively reviewed at 5-year follow-up. All had suffered subacute or chronic tears of the ligament. At surgery, the femoral tunnel was drilled first through the antero-medial portal. The correct position of the femoral and tibial guide wire was checked fluoroscopically. A cortical fixation to the bone was achieved in the femur with a Mitek anchor, directly passing the two tendons in the slot of the anchor, and in the tibia with an RCI screw, supplemented with a spiked washer and bicortical screw. Rehabilitation was aggressive, controlled and without braces. The International Knee Documentation Committee (IKDC) form, KT-1000 arthrometer, and Cybex dynamometer were employed for clinical evaluation. A radiographic study was also performed. At the 5-year follow-up all the patients had recovered full range of motion and 2% of them complained of pain during light sports activities. Four patients (9.5%) reported giving-way symptoms. The KT-1000 side-to-side difference was on average 2.1 mm at 30 lb, and 68% of the knees were within 2 mm. The final IKDC score showed 90% satisfactory results. There was no difference between the 2-year and 5-year evaluations in terms of stability. Extensor and flexor muscle strength recovery was almost complete (maximum deficit 5%). Radiographic study showed a tunnel widening in 32% of the femurs and 40% of the tibias. A correlation was found between the incidence of tibial tunnel widening and the distance of the RCI screw from the joint (the closer the screw to the joint, the lower the incidence of widening). In conclusion, we can state that, using a four-strand hamstring graft and a cortical fixation at both ends, we were able to achieve satisfactory 5-year results in 90% of the patients.

Adolescent↗