PubMed Health⌕ Search

Biomedical subjects

Pierre Alain Gevenois

Publications and source records attributed to Pierre Alain Gevenois.

17 recordsLinked to original sources

Assessment of pretest probability of pulmonary embolism in the emergency department by physicians in training using the Wells model.

INTRODUCTION: Assessment of pretest probability should be the initial step in investigation of patients with suspected pulmonary embolism (PE). In teaching hospitals physicians in training are often the first physicians to evaluate patients. OBJECTIVE: To evaluate the accuracy of pretest probability assessment of PE by physicians in training using the Wells clinical model and to assess the safety of a diagnostic strategy including pretest probability assessment. PATIENTS AND METHODS: 291 consecutive outpatients with clinical suspicion of PE were categorized as having a low, moderate or high pretest probability of PE by physicians in training who could take supervising physicians' advice when they deemed necessary. Then, patients were managed according to a sequential diagnostic algorithm including D-dimer testing, lung scan, leg compression ultrasonography and helical computed tomography. Patients in whom PE was deemed absent were followed up for 3 months. RESULTS: 34 patients (18%) had PE. Prevalence of PE in the low, moderate and high pretest probability groups categorized by physicians in training alone was 3% (95% confidence interval (CI): 1% to 9%), 31% (95% CI: 22% to 42%) and 100% (95% CI: 61% to 100%) respectively. One of the 152 untreated patients (0.7%, 95% CI: 0.1% to 3.6%) developed a thromboembolic event during the 3-month follow-up period. CONCLUSION: Physicians in training can use the Wells clinical model to determine pretest probability of PE. A diagnostic strategy including the use of this model by physicians in training with access to supervising physicians' advice appears to be safe.

Adolescent↗

Severe pulmonary embolism:pulmonary artery clot load scores and cardiovascular parameters as predictors of mortality.

PURPOSE: To retrospectively evaluate pulmonary artery (PA) clot load scores and computed tomographic (CT) cardiovascular parameters as predictors of mortality in patients with severe pulmonary embolism (PE). MATERIALS AND METHODS: Institutional review board approval was obtained with waiver of informed consent. A total of 82 consecutive patients (42 women, 40 men; mean age+/-standard deviation, 61 years+/-15) were admitted to the intensive care unit for PE-related conditions and were evaluated by using CT pulmonary angiography. Two independent readers who were blinded to clinical outcome quantified PA clot load by using four scoring systems. Cardiovascular measurements included right ventricular (RV) and left ventricular (LV) short-axis measurements; RV short axis to LV short axis (RV/LV) ratios; main PA, ascending aorta, azygos vein, and superior vena cava diameters; and main PA diameter to aorta diameter ratios. Reflux of contrast medium into the inferior vena cava, leftward bowing of the interventricular septum, pleural or pericardial effusion, pulmonary consolidation, infarct, platelike atelectasis, and mosaic ground-glass opacity were also recorded. Results were correlated with patient outcome during hospital stay by using the Wilcoxon rank sum and chi2 tests. RESULTS: Twelve patients died within 1-14 days. RV and LV short axis; RV/LV ratio; azygos vein, superior vena cava, and aorta diameters; and contrast medium reflux into the inferior vena cava were significantly different between survivors and nonsurvivors (P<.05). No significant relationship was found between PA clot load and mortality rate. RV/LV ratio and azygos vein diameter allowed correct prediction of survival in 89% of patients (P<.001). CONCLUSION: RV/LV ratio and azygos vein diameter are predictors of mortality in patients with severe PE.

Adult↗

Pulmonary emphysema: objective quantification at multi-detector row CT--comparison with macroscopic and microscopic morphometry.

PURPOSE: To prospectively compare pulmonary function tests and helical computed tomographic (CT) indexes for quantifying pulmonary emphysema with macroscopic and microscopic morphometry. MATERIALS AND METHODS: The investigation was approved by the local ethics committee, and written informed consent was obtained from patients. Multi-detector row CT of the thorax was performed with simultaneous acquisition of four 1-mm sections in 80 patients (57 men, 23 women; age range, 38-79 years) referred for surgical resection of lung cancer. From the raw data, 1.25-mm-thick sections were reconstructed at 10-mm intervals. Relative areas of lung with attenuation coefficients lower than nine thresholds and eight percentiles of the distribution of attenuation coefficients were calculated. Relative areas and percentiles were compared with areas found macroscopically to have emphysema and with two microscopic indexes assessed on resected specimens. Pulmonary function tests were measured 24-48 hours before surgery. Spearman correlation coefficients were calculated between each set of CT data obtained with the nine tested thresholds and eight percentiles with macroscopic and microscopic measurements. RESULTS: For relative lung areas, the strongest correlation with macroscopy was observed with a threshold of -970 HU (r = 0.543, P < .001) and that with microscopy was observed at -960 and -970 HU, depending on the index considered (r = 0.592, P < .001 and r = -0.546, P < .001, respectively). For percentiles, 1st percentile showed the strongest correlation with both macroscopy (r = -0.463, P < .001) and microscopy (r = -0.573, P < .001; and r = 0.523, P < .001 for each microscopic measurement). Forced expiratory volume in 1 second and vital capacity ratio, diffusing capacity of lung for carbon monoxide, and each of the three CT indexes were complementary to predict microscopic indexes. CONCLUSION: Relative lung areas with attenuation coefficients lower than -960 or -970 HU and 1st percentile are valid indexes to quantify pulmonary emphysema on multi-detector row CT scans.

Adult↗

Elastase-induced pulmonary emphysema in rats: comparison of computed density and microscopic morphometry.

PURPOSE: To prospectively compare computed tomographic (CT) quantification of pulmonary emphysema in elastase-treated rats with morphometry and to evaluate the information yielded by CT quantification and pulmonary function tests. MATERIALS AND METHODS: This study was approved by the local committee on care and use of animals in research. Thirty-six animals were used. Emphysema was produced by means of one or two tracheal injections of 300 IU of elastase, 8 weeks apart, in seven and 12 rats, respectively. As a control group, 10 rats received an injection of normal saline. The dynamic resistance, dynamic compliance, and static compliance were measured. CT was performed with 1-mm section thickness and 3-mm intervals. Relative areas of lung with attenuation coefficients lower than nine chosen thresholds (from -900 to -980 HU) and eight percentiles (from 1st to 18th percentiles) of the distribution of attenuation coefficients were compared with measurements of alveoli size--that is, mean interwall distance (MIWD) and mean perimeter per field (MP). Correlations between data obtained with thresholds and percentiles and MIWD and MP were investigated by means of Spearman coefficients (r(s)). Values of pulmonary function tests, most appropriate relative area threshold, and percentile were investigated by means of stepwise multiple regressions. RESULTS: For thresholds, relative surface area with attenuation coefficients less than -940 HU (RA(940)) showed the strongest correlations with findings at microscopy (r(s) = 0.676, P < .001 for MIWD; r(s) = -0.720, P < .001 for MP). For percentiles, the 3rd percentile showed the strongest correlations (r(s) = -0.647, P < .001 for MIWD; r(s) = 0.701, P < .001 for MP). Dynamic compliance and RA(940) or 3rd percentile were complementary for predicting microscopic measurements. CONCLUSION: In rats, RA(940) and the 3rd percentile reflect the extent of elastase-induced pulmonary emphysema and are complementary to dynamic compliance to predict microscopic extent.

Animals↗

Involvement of the anterior portion of the subacromial-subdeltoid bursa in the painful shoulder.

OBJECTIVE: The purpose of our study was to verify that increased widening of the anterior portion of the subacromial-subdeltoid bursa is associated with anteromedial shoulder pain. MATERIALS AND METHODS: Bursography, sonography, and CT were performed in six cadaver shoulders and compared with anatomic sections in neutral position and while the humerus was extended and internally rotated. For the clinical study, the width of the anterior portion of the bursa was measured in both positions in both shoulders of 27 patients referred because of shoulder pain and in eight asymptomatic volunteers. Pain was coded as absent, experienced in the anteromedial portion of the shoulder, or experienced elsewhere but not anteromedially, and we compared the pain scores between shoulder positions. RESULTS: In all cadaver shoulders, when compared with CT scans and anatomic sections, sonography showed the morphology of the bursa, its relationships with surrounding structures, and morphologic changes associated with position. In volunteers, the mean width of the bursa was 0.74 +/- 0.05 and 0.93 +/- 0.09 mm (p = 0.013), respectively, in neutral and stress position. In patients, the same values were 0.70 +/- 0.07 and 0.81 +/- 0.14 mm (p = 0.286) in the asymptomatic side and 1.20 +/- 0.11 and 1.75 +/- 0.23 mm (p < 0.001) in the symptomatic side, respectively. The bursa was wider in patients experiencing pain anteromedially than in those who experienced pain elsewhere and volunteers (p = 0.002 and < 0.001, respectively), and the bursa was wider in symptomatic shoulders than in asymptomatic shoulders (p < 0.001). CONCLUSION: Widening of the anterior portion of the subacromial-subdeltoid bursa is associated with anteromedial shoulder pain and the clinical syndrome of coracoid impingement.

Adult↗

Suspected acute colon diverticulitis: imaging with low-dose unenhanced multi-detector row CT.

PURPOSE: To prospectively compare the sensitivity and specificity of unenhanced low-dose multi-detector row computed tomography (CT) with those of contrast material-enhanced standard-dose multi-detector row CT in patients suspected of having acute diverticulitis. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. One hundred ten consecutive patients (40 men, 70 women; age range, 30-82 years; mean, 57 years) suspected of having acute diverticulitis underwent unenhanced multi-detector row CT with 4 x 2.5-mm collimation, 120 kVp, and 30 effective mAs, as well as contrast-enhanced standard-dose multi-detector row CT with the same parameters but with 120 mAs. All scans were independently read by four readers. Intra- and interobserver agreements were calculated with the kappa statistic. Contrast-enhanced standard-dose scans read by three other experts and considered together with results from colonoscopy, surgery, and pathologic evaluation were used as reference. Differences in sensitivity and specificity between readers, radiation doses, and reading sessions were investigated. Pearson exact test and logistic regression models were used. RESULTS: Colon diverticulitis was present in 39 patients (34%) and was graded as mild in 22 patients (56%) and severe in 17 (44%). Agreement within and between readers was good to excellent. No significant difference was observed in sensitivity (P ranging from .081 to >.99) or in specificity (P ranging from .326 to >.99) for any sign or overall diagnosis between radiation doses by all readers, except wall thickening, which for one reader had a higher specificity at low dose than at standard dose (P = .025). No significant difference in misclassification was detected between doses, regardless of the reader (P ranging from .481 to >.99). At both doses, the most predictive sign for acute diverticulitis was retroperitoneal fat stranding (P < .001). CONCLUSION: Low-dose unenhanced multi-detector row CT has a diagnostic performance similar to that of contrast-enhanced standard-dose multi-detector row CT in patients suspected of having acute diverticulitis.

Acute Disease↗

Multi-detector row CT pulmonary angiography: comparison of standard-dose and simulated low-dose techniques.

PURPOSE: To compare standard-dose and simulated low-dose multi-detector row computed tomography (CT) pulmonary angiography. MATERIALS AND METHODS: The institutional review board approved the study protocol and waived patient informed consent because the study was based on existing data. Raw data from 21 CT scans obtained at 90 mAs (effective) in 11 women and 10 men aged 25-74 years (mean, 52 years) that showed at least one filling defect within a pulmonary artery were used to simulate CT pulmonary angiography with reduced radiation doses, at 60, 40, 20, and 10 mAs. Three independent readers coded each central and segmental pulmonary artery twice as positive, negative, or inconclusive for presence of a filling defect. The second reading of images obtained with 90 mAs was considered the reference standard. The potential dependence of results on reader, radiation dose, and/or pulmonary artery segment was investigated with analysis of variance. Positive and negative consistent values were calculated for standard-dose scans and simulated low-dose scans in the first reading session. The branching order of the artery with the most distal filling defect was recorded. The quality of intravascular contrast at each tube current-time product setting was scored on a five-point scale. Interreader agreement was investigated with kappa statistics. RESULTS: The frequencies of positive and inconclusive results (P = .21 and .08, respectively), positive and negative consistent values (P = .19 and .34, respectively), and branching order of the most distal artery with a filling defect (P = .41) did not depend on the radiation dose. Values for inter- and intrareader agreement were higher for central arterial segments than for branch arteries but were not influenced by dose reduction, regardless of arterial segment. The quality of intravascular contrast was not significantly changed when the tube current-time product was reduced from 90 to 40 mAs (P = .10 to >.99). CONCLUSION: The evaluated parameters remained stable when tube current-time product was reduced from 90 (effective) to 10 (simulated) mAs at multi-detector row CT pulmonary angiography.

Adult↗

Comparison of US and unenhanced multi-detector row CT in patients suspected of having acute appendicitis.

PURPOSE: To prospectively compare the diagnostic performance of ultrasonography (US) and unenhanced multi-detector row computed tomography (CT) in patients suspected of having acute appendicitis by using surgery or clinical follow-up as the reference standard. MATERIALS AND METHODS: The institutional review board approved the research protocol. Written informed consent was obtained from all patients or, for those who were adolescents, from their parents. Ninety-four patients (59 female and 35 male patients) aged 16-81 years (mean, 38 years) who were suspected of having acute appendicitis underwent both US and unenhanced multi-detector row CT of the entire abdomen. The examinations were performed within 1-2 hours of each other. US and CT images were obtained and prospectively interpreted by a different radiologist from a group of abdominal radiologists or a group of residents and general radiologists. Radiologists proposed an overall diagnosis and an alternative diagnosis. Data from US and CT were compared, and the definite diagnosis was established with surgical findings (n = 40) or results of clinical follow-up (n = 54) as the reference standard. Comparisons were made for each group of radiologists and the patient's age, body mass index (BMI), and sex. Proportion comparisons were made by using the Pearson chi2 test or the Fisher exact test. Continuous variables were compared between groups with the Mann-Whitney U test. RESULTS: Thirty patients had definite appendicitis. The sensitivity, specificity, positive and negative predictive values, and accuracy were not significantly different between US and CT or between groups of radiologists (P values ranged from .389 to >.99), regardless of the patient's BMI (P values ranged from .073 to >.99). Misclassifications were compared with the definite alternative diagnosis and were not significantly different between US and CT or between groups of radiologists (P = .061-.592), regardless of patient age (P = .875) or sex (P = .151 and >.99 for male and female patients, respectively). The frequency of inconclusive examinations, however, was significantly higher with US than with CT, regardless of radiologist experience (P = .020 and <.001, respectively). CONCLUSION: Although the diagnostic performances of US and multi-detector row CT are comparable, more inconclusive images were obtained with US.

Acute Disease↗

Silicosis: expiratory thin-section CT assessment of airway obstruction.

PURPOSE: To prospectively evaluate if findings on paired inspiratory and expiratory thin-section computed tomographic (CT) scans in patients with silicosis correlate with pulmonary function test results. MATERIALS AND METHODS: Institutional review board approval and patient consent were obtained. Thirty-seven men (mean age, 71 years; range, 53-88 years) with silicosis were included. All patients had undergone inspiratory and expiratory thin-section CT and spirometry. Silicotic nodules, large opacity, emphysema, reticular opacities, bronchiectasis, and air trapping were graded subjectively on CT images. Emphysema was quantified on these images with built-in software. CT numbers were correlated with spirometric findings by using Spearman rank correlation analyses. Ten healthy volunteers (three men and seven women; mean age, 58 years) served as control subjects. RESULTS: After exclusion of three patients with inadequate image quality, 34 patients (mean age, 70 years; range, 53-88 years) were enrolled in the study group. Spirometric values did not differ significantly between patients with simple (n = 20) and patients with complicated (n = 14) silicosis but were significantly lower in patients than in control subjects. CT findings included air trapping (n = 33), emphysema (n = 26), nodules (n = 32), bronchiectasis (n = 22), large opacity (n = 19), and reticulation (n = 5). The extent of both air trapping and emphysema correlated negatively with spirometric values; the air trapping score showed the strongest correlation (ratio of forced expiratory volume in 1 second to forced vital capacity [FVC]: rho = -0.632, P < .001; forced expiratory flow at 50% of the FVC: rho = -0.576, P = .001). Silicotic nodule, large opacity, and bronchiectasis scores did not correlate with obstructive functional impairments. CONCLUSION: In comparison with the spirometric value, the extent of air trapping proved the best CT index in the assessment of obstructive derangement in workers with exposure to silica dust.

Aged↗

Acute appendicitis: comparison of low-dose and standard-dose unenhanced multi-detector row CT.

PURPOSE: To prospectively compare low- and standard-dose unenhanced multi-detector row computed tomography (CT) in patients suspected of having acute appendicitis. MATERIALS AND METHODS: Ninety-five consecutive patients underwent two unenhanced multi-detector row CT examinations with 4 x 2.5-mm collimation, 120 kVp, and 30 and 100 effective mAs. Two radiologists independently read the images obtained at each dose during two sessions. Readers recorded visualization of the appendix and presence of gas in its lumen, appendicolith, periappendiceal fat stranding, cecal wall thickening, and abscess or phlegmon to measure the diameter of the appendix and to propose diagnosis (appendicitis or alternative). Data were compared according to dose and reader, with definite diagnosis established on basis of surgical findings (n = 37) or clinical follow-up. chi(2) tests and logistic regression were used. Measurement agreements were assessed with Cohen kappa statistics. RESULTS: Twenty-nine patients had a definite diagnosis of appendicitis. No difference was observed between the frequency of visualization of the appendix (P =.874) neither in its mean diameter (P =.101-.696, according to readers and sessions) nor in the readers' overall diagnosis (P =.788) at each dose. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of each sign were not different between doses. Fat stranding, appendicolith, and diameter were the most predictive signs, regardless of dose, yielding approximately 90% of correct diagnoses. The ability to propose a correct alternative diagnosis was not influenced by the dose. CONCLUSION: Low-dose unenhanced multi-detector row CT has similar diagnostic performance as standard-dose unenhanced multi-detector row CT for the diagnosis of acute appendicitis.

Acute Disease↗

Air trapping in heart-lung transplant recipients: variability of anatomic distribution and extent at sequential expiratory thin-section CT.

PURPOSE: To evaluate the intrapatient reproducibility of the extent and anatomic distribution of air trapping at sequential expiratory thin-section computed tomographic (CT) examinations in heart-lung transplant recipients. MATERIALS AND METHODS: Nineteen heart-lung transplant recipients (eight with and 11 without bronchiolitis obliterans syndrome [BOS]) underwent three expiratory CT examinations within 1 hour. Residual volumes were measured at CT. Anatomic distribution and extent of air trapping were scored by two observers at two independent readings, and the reproducibility of observations was calculated for each feature. CT examination results were compared by using an analysis of variance that took into account interobserver and BOS and non-BOS effects. The Spearman rank correlation coefficient was calculated to test the association between variability of residual volumes and variability of the extent of air trapping. RESULTS: Residual volumes did not significantly differ between the three CT examinations (P =.556). Reproducibility values for findings of anatomic distribution of air trapping ranged from 84% to 95%, with a tendency toward improved reproducibility in patients without BOS. Mean reproducibility values for the extent of air trapping ranged from 97.1% to 97.7%, and no substantial difference in these values between patients with and those without BOS was observed. The Spearman rank coefficient for the correlation between variability of residual volumes and variability of extent of air trapping ranged from 0.382 to 0.568 (P =.105-.016). No interobserver effect was detected (P =.944). CONCLUSION: Anatomic distribution and extent are reproducible characteristics of air trapping. No substantial variability of air trapping occurs in functionally stable heart-lung transplant recipients.

Adult↗

Low-dose unenhanced multidetector CT of patients with suspected renal colic.

OBJECTIVE: This study is designed to assess the intraobserver and interobserver agreements and the diagnostic performances of low-dose unenhanced multidetector CT (MDCT) in patients with suspected renal colic. SUBJECTS AND METHODS: The study included 106 patients who underwent unenhanced MDCT with 4 x 2.5 mm collimation, 120 kVp, 30 mAs, and, if necessary, additional focused acquisitions at 60 or 120 mAs on areas with an equivocal ureteral stone or with significant image noise. The effective radiation dose was computer-simulated with software based on the Monte Carlo model and International Commission on Radiological Protection recommendations. CT scans were archived and independently reviewed by three radiologists during two interpretation sessions on a workstation with three dimensions functions. Intraobserver and interobserver agreements were calculated with the kappa statistics. Accuracy for detection of ureteral stone on low-dose MDCT was calculated by comparison with combined clinical (stone passage), surgical (stone retrieval, extracorporeal shock wave lithotripsy), biologic (urinalysis, urine culture), and other imaging (excretory urography, standard-dose MDCT, follow-up sonography, and abdominal radiography) findings or by evidence for an alternative diagnosis. RESULTS: Ureteral stones were present in 38 (36%) of 106 patients. Thirty-six of 38 ureteral stones were detected by low-dose MDCT. From reviewer to reviewer, the number of true-positive, false-positive, true-negative, and false-negative findings ranged, respectively, from 34 to 36, 1 to 4, 64 to 68, and 2 to 4. The corresponding sensitivity, specificity, and accuracy ranged from 89.5% to 94.7%, from 94.1% to 100%, and from 93.4% to 98.1%, respectively. The intraobserver and interobserver agreements were excellent, with kappa values ranging from 0.87 to 0.98. In 13 patients, an alternative diagnosis explaining the patient's symptoms was proposed by all reviewers using images obtained at 30 mAs. No additional or alternative diagnosis was found at standard dose. At 30 mAs, the mean effective dose was 1.2 mSv in men and 1.9 mSv in women. Additional acquisitions at 60 mAs, all focused on the lower pelvis, were acquired in 20 patients, but the corresponding images were needed by the reviewers for only six of them. The acquisitions at 60 mAs were responsible for an additional mean effective dose of 0.5 in men and 0.8 mSv in women. CONCLUSION: Our study shows that low-dose unenhanced MDCT is appropriate for the diagnosis of ureteral stones, and that it provides excellent intraobserver and interobserver agreements and does not obscure alternative diagnoses.

Adolescent↗

Dose reduction in multidetector CT using attenuation-based online tube current modulation.

OBJECTIVE: This study was designed to quantify the radiation dose saved by attenuation-based online tube current modulation applied to multidetector CT (MDCT) of the adult trunk as a function of effective milliampere-second (mAs) presets, sex, and body habitus. SUBJECTS AND METHODS. One hundred twenty patients underwent MDCT of the trunk (60 thoracic, 60 abdominal) with an attenuation-based online tube current modulation. Consecutive acquisitions at standard and two lower effective mAs presets were obtained in each patient. Mean percentage effective mAs reductions were compared for each effective mAs preset, taking into account sex and body mass index. RESULTS: Mean effective mAs reduction was 16.9% and 20.0% for the chest and the abdomen, respectively. Mean percentage effective mAs reductions were found to be significantly different for sex (chest, p = 0.003; abdomen, p = 0.002) but not significantly different for the different effective mAs presets or body mass index. CONCLUSION: Attenuation-based online tube current modulation used with MDCT should be considered as a secondary tool of radiation dose reduction because it saves as much as 20% of the radiation dose on the adult trunk, regardless of initial mAs preset. However, initial decreases of mAs presets by the physician should be considered the primary tool for radiation dose reduction.

Adult↗

Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis.

OBJECTIVE: This study was designed to compare low- and standard-dose multidetector CT (MDCT) findings in patients with suspected chronic sinusitis. SUBJECTS AND METHODS. Fifty patients underwent MDCT at 10 and 150 effective mAs. The low-dose MDCT protocol delivered a radiation dose of 0.047 mSv in men and 0.051 mSv in women, whereas the standard-dose MDCT protocol delivered a radiation dose of 0.70 mSv in men and 0.76 mSv in women. Scans of the right and left sides of sinonasal cavities were reviewed by three radiologists, with each physician reviewing a scan twice over an interval of more than 2 weeks. The reviewers were asked to evaluate the scans for eight mucosal and two bone abnormalities. We calculated the number of discrepancies in observed abnormalities between pairs of reviewers, among all three reviewers, and between findings on scans acquired with the two radiation doses. RESULTS: The mean number of discrepancies in observed abnormalities on scans acquired with different radiation doses ranged from 0 to 5.2. Discrepancies between pairs of reviewers ranged from 1.0 to 12.8 for low-dose scans and from 1.0 to 13.0 for standard-dose scans. Discrepancies among all reviewers ranged from 1.0 to 10.3 for low-dose scans and from 1.0 to 8.7 for standard-dose scans. In analyzing cases of significant discrepancies in observations, we found greater variation between pairs of reviewers and among all three reviewers than between findings obtained with different dose levels. CONCLUSION: Dose reduction played a far less important role in discrepancies of detected abnormalities than did the human element of reviewer observation. Given this finding and the fact that low-dose MDCT delivers a radiation dose that is no higher than that delivered by a four-view radiographic examination, low-dose MDCT should be considered the imaging method of choice in patients with suspected chronic sinusitis.

Adolescent↗

Abnormal pulmonary vascular tone in canine oleic acid lung injury.

OBJECTIVE: To characterize the endothelium-dependent and endothelium-independent components of abnormal pulmonary vascular tone in canine oleic acid lung injury. DESIGN: Prospective, interventional study. SETTING: University laboratory. SUBJECTS: Twenty anesthetized mongrel dogs. INTERVENTIONS: Right heart catheterization was performed to measure pulmonary vascular resistance before and after induction of oleic acid lung injury in ten anesthetized and ventilated dogs. Pulmonary and internal mammary artery rings were sampled in these ten dogs with oleic acid injury and in ten anesthetized healthy control dogs. We also studied the responses to acetylcholine, to phenylephrine, and to hypoxia of the intact or endothelium-denuded rings mounted in organ baths. MEASUREMENTS AND MAIN RESULTS: Oleic acid lung injury was associated with an increase in pulmonary vascular resistance from 118 +/- 11 to 245 +/- 47 dyne.sec.cm-5.m-2 and a decrease in the Pao2/Fio2 ratio from 451 +/- 42 to 139 +/- 26 mm Hg (mean +/- se, p <.05 and p <.01, respectively). Acetylcholine-induced relaxation was decreased in the oleic acid pulmonary artery rings compared with the controls (85 +/- 3% vs. 99 +/- 6% of precontraction level, p <.05). Phenylephrine-induced contraction was decreased in denuded oleic acid pulmonary artery rings compared with the controls (81 +/- 8% vs. 102 +/- 10% of contraction to KCl 120 mM, p <.05). In vitro hypoxia induced a small endothelium-dependent contraction followed by an endothelium-independent relaxation. These responses were not different in oleic acid lung artery rings and in controls, except for a decrease in hypoxic contraction in the oleic acid pulmonary artery rings. In vitro hypoxic pulmonary vasoconstriction and relaxation were, respectively, directly (r =.48) and inversely (r = -.67) correlated with oleic acid-induced increase in pulmonary vascular resistance. There was no correlation between in vitro internal mammary artery reactivity and oleic acid-induced increase in pulmonary vascular resistance. CONCLUSIONS: Oleic acid-induced lung injury slightly impairs pulmonary arterial endothelium-dependent relaxation and endothelium-independent contraction. In vitro hypoxic pulmonary vasoreactivity is related to in vivo oleic acid-induced increase in pulmonary vascular resistance.

Animals↗

CT quantification of pulmonary emphysema: assessment of lung structure and function.

Accurate diagnosis and quantification of pulmonary emphysema in vivo is important to understand the natural history of the disease, to assess the extent of the disease, and to evaluate and follow-up therapeutic interventions. Because pulmonary emphysema is defined by pathology, new diagnostic methods for quantification should be validated by reference to pathological and histological standards. Recent studies have addressed the capability of computed tomography (CT) to accurately quantify pulmonary emphysema. These studies that have been overviewed in this article have been based on CT scans obtained after deep inspiration or expiration, on subjective visual grading, and on objective measurements of attenuation values by using dedicated software providing numerical data on two-dimensional and on three-dimensional approaches, and compared CT data with pulmonary function tests. More recently, fractal and textural analyses were applied to CT scans to assess the presence, extent, and types of emphysema. Quantitative CT has already been used in patient selection for surgical treatment of pulmonary emphysema and in pharmacotherapeutical trials. However, despite numerous and extensive studies already available, this technique has not yet been standardized, and important questions about how to best use CT for the quantification of pulmonary emphysema remain to be addressed.

Age Factors↗