PubMed Health⌕ Search

Biomedical subjects

Pierre J Obeid

Publications and source records attributed to Pierre J Obeid.

3 recordsLinked to original sources

Rapid analysis of genetically modified organisms by in-house developed capillary electrophoresis chip and laser-induced fluorescence system.

A microfabricated, inexpensive, reusable glass capillary electrophoresis chip and a laser-induced fluorescence system were developed in-house for the rapid DNA-based analysis of genetically modified organisms (GMOs). The 35S promoter sequence of cauliflower mosaic virus and the terminator of the nopaline synthase (NOS) gene from Agrobacterium tumefaciens were both detected since they are present in most genetically modified organisms. The detection of genetically modified soybean in the presence of unaltered soybean was chosen as a model. Lectin, a plant-specific gene, was also detected for confirmation of the integrity of extracted DNA. The chip was composed of two glass plates, each 25 x 76 mm, thermally bonded together to form a closed structure. Photomasks with cross-topology were prepared rapidly by using polymeric material instead of chrome plates. The widths of the injection and separation channels were 30 and 70 microm, respectively, the effective separation length 4.5 cm. The glass slide was etched to a depth of 30 microm for both the injection and separation channel. The cost of the chip was less than 1 $ and required 2 days for photomask preparation and microfabrication. The separation and detection of polymerase chain reaction-amplified NOS, 35S, and lectin sequences (180, 195, and 181 bp, respectively) was completed in less than 60 s. As low as 0.1% GMO content was detectable by the proposed system after 35 and 40 amplification cycles for 35S and NOS, respectively, using 25 ng of extracted DNA as starting material. This corresponds to only 20 genome copies of genetically modified soybean.

Amino Acid Oxidoreductases↗

Microfabricated systems for nucleic acid analysis.

High throughput and automation of nucleic acid analysis are required in order to exploit the information that has been accumulated from the Human Genome Project. Microfabricated analytical systems enable parallel sample processing, reduced analysis-times, low consumption of sample and reagents, portability, integration of various analytical procedures and automation. This review article discusses miniaturized analytical systems for nucleic acid amplification, separation by capillary electrophoresis, sequencing and hybridization. Microarrays are also covered as a new analytical tool for global analysis of gene expression. Thus. instead of studying the expression of a single gene or a few genes at a time we can now obtain the expression profiles of thousands of genes in a single experiment.

DNA↗

Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection.

We have developed a high-throughput microfabricated, reusable glass chip for the functional integration of reverse transcription (RT) and polymerase chain reaction (PCR) in a continuous-flow mode. The chip allows for selection of the number of amplification cycles. A single microchannel network was etched that defines four distinct zones, one for RT and three for PCR (denaturation, annealing, extension). The zone temperatures were controlled by placing the chip over four heating blocks. Samples and reagents for RT and PCR were pumped continuously through appropriate access holes. Outlet channels were etched after cycles 20, 25, 30, 35, and 40 for product collection. The surface-to-volume ratio for the PCR channel is 57 mm(-1) and the channel depth is 55 microm, both of which allow very rapid heat transfer. As a result, we were able to collect PCR product after 30 amplification cycles in only 6 min. Products were collected in 0.2-mL tubes and analyzed by agarose gel electrophoresis and ethidium bromide staining. We studied DNA and RNA amplification as a function of cycle number. The effect of the number of the initial DNA and RNA input molecules was studied in the range of 2.5 x 10(6) - 1.6 x 10(8) and 6.2 x 10(6) - 2 x 10(8), respectively. Successful amplification of a single-copy gene (beta-globin) from human genomic DNA was carried out. Furthermore, PCR was performed on three samples of DNA of different lengths (each of 2-microL reaction volume) flowing simultaneously in the chip, and the products were collected after various numbers of cycles. Reverse transcription was also carried out on four RNA samples (0.7-microL reaction volume) flowing simultaneously in the chip, followed by PCR amplification. Finally, we have demonstrated the concept of manually pumped injection and transport of the reaction mixture in continuous-flow PCR for the rapid generation of amplification products with minimal instrumentation. To our knowledge, this is the first report of a monolithic microdevice that integrates continuous-flow RT and PCR with cycle number selection.

DNA↗