PubMed Health⌕ Search

Biomedical subjects

Pierre Lantéri

Publications and source records attributed to Pierre Lantéri.

3 recordsLinked to original sources

Characterization and comparison of the chromatographic performance of different types of reversed-phase stationary phases.

The chromatographic performance of several base-deactivated stationary phases was evaluated with a specific chromatographic test. Seven basic test compounds, possessing different physico-chemical properties were injected on different supports with two mobile phases: one at pH 7.0 (acetonitrile-phosphate buffer, 40:60, v/v), and the other at pH 3.0 (acetonitrile-phosphate buffer, 15:85, v/v). Chromatographic parameters obtained under these conditions were treated by principal component analysis (PCA) to separate base deactivated supports according to their silanol activity (pH 7.0 mobile phase) and hydrophobic properties (pH 3.0 mobile phase). The information given by the specific test column evaluation was improved with complementary chemometric tools such as hierarchical cluster analysis. The same base deactivated supports were also tested following a general test procedure issued from the literature and obtained fundamental properties (in particular silanol activity and hydrophobicity) were compared with column evaluation obtained with the specific test: results were in good agreement, although the use of the specific test offered a better differentiation between numerous base-deactivated supports.

Chemical Phenomena↗

Influence of metal salts on the photodegradation of imazapyr, an imidazolinone pesticide.

The behaviour of imazapyr (2-(4-isopropyl-4-methyl-5-oxo-2-imidazolin-2-yl)nicotinic acid), a broad spectrum herbicide of the imidazolinone family, has been studied under UV radiation in the presence of metal salts. Complexation interactions between imazapyr and metal ions decreased imazapyr photolysis. A chemometric study compared the photodegradation of imazapyr in aqueous solutions in the presence of Na+, Ca2+ or Cu2+ and their concomitant anionic species (Cl-, NO3-) at various pesticide/metal ion molar ratios. The study showed the major role of metal ions in the degradation of imazapyr and its main photoproducts. The molecules were strongly stabilised on complexation with metal ions, leading to an increase in persistence of the pesticide.

Copper↗

A study of interlaboratory influence on column evaluation.

A liquid chromatography method for the characterization of base deactivated columns was investigated in a collaborative study involving six laboratories. This work was carried out on two chromatographic supports (Xterra RP 18 and Symmetry Shield). Different cooling systems, namely water bath and air oven, were tested and it was shown that column thermoregulation did not significantly influence chromatographic data. In order to control the mobile phase composition, the latter was prepared by weight rather than volume. Thanks to the injection of a set of selected neutral compounds, extra-column effects were evaluated in each of the participating laboratories. The results showed that chromatographic supports tested in different laboratories and following the same test protocol could be effectively compared.

Chromatography, High Pressure Liquid↗