PubMed Health⌕ Search

Biomedical subjects

Pierre Schnyder

Publications and source records attributed to Pierre Schnyder.

At least 37 records · Page 2Linked to original sources

Admission perfusion CT: prognostic value in patients with severe head trauma.

PURPOSE: To assess the prognostic value of admission perfusion computed tomography (CT) in patients with severe head trauma. MATERIALS AND METHODS: This prospective study included 130 patients with severe trauma, aged 19-86 years, admitted with a Glasgow Coma Scale score of 8 or less. They underwent perfusion CT as part of their admission CT survey. Clinical data, unenhanced cerebral CT findings, and perfusion CT scans were evaluated with respect to the Glasgow Outcome Scale (GOS) score at 3 months. Perfusion CT features were evaluated in patients with intracranial hypertension, cerebral contusions, and juxtadural hematomas. Ordered logistic regression was used to determine risk factors for an unfavorable GOS score at 3 months. RESULTS: Perfusion CT was more sensitive than conventional unenhanced CT in the detection of cerebral contusions. Perfusion CT featured specific patterns with respect to patient outcome, with normal brain perfusion or hyperemia in patients with favorable outcome, and oligemia in patients with unfavorable outcome. The number of arterial territories with low regional cerebral blood volume at perfusion CT was an independent prognostic factor (P =.008), as were mean arterial pressure at the scene of accident (P =.083), base excess at admission (P =.002), presence of skull fractures (P =.041), and signs of herniation (P =.013) at admission unenhanced cerebral CT. Perfusion CT also showed a range of brain perfusion alterations in patients with juxtadural collections, cerebral edema, or intracranial hypertension. CONCLUSION: Perfusion CT in patients with severe head trauma provides independent prognostic information regarding functional outcome.

Adult↗

Prevention of atelectasis formation during the induction of general anesthesia in morbidly obese patients.

UNLABELLED: Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (body mass index >35 kg/m(2)) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H(2)O and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H(2)O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% +/- 4.8% in control group versus 1.7% +/- 1.3% in PEEP group; P < 0.001). After intubation with a fraction of inspired oxygen of 1.0, PaO(2) was significantly higher in the PEEP group compared with the control group (457 +/- 130 mm Hg versus 315 +/- 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation. IMPLICATIONS: Application of positive end-expiratory pressure during induction of general anesthesia in morbidly obese patients prevents atelectasis formation and improves oxygenation. Therefore, this technique should be considered for anesthesia induction in morbidly obese patients.

Adult↗

Brain perfusion in children: evolution with age assessed by quantitative perfusion computed tomography.

OBJECTIVE: The objective of this study was to assess the age-related variations of brain perfusion through quantitative cerebral perfusion computed tomography (CT) results in children without brain abnormality. METHODS: Brain perfusion CT examinations were performed in 77 children, aged 7 days to 18 years. These patients were admitted at our institution for both noncontrast and contrast-enhanced cerebral CT. Only children whose conventional cerebral CT and clinical/radiologic follow-up, including additional investigations, were normal were taken into account for this study (53 of 77). RESULTS: The average regional rCBF amounts to 40 (mL/100 g per minute) for the first 6 months of life, peaks at approximately 130 (mL/100 g per minute) at approximately 2 to 4 years of age, and finally stabilizes at approximately 50 (mL/100 g per minute) at approximately 7 to 8 years of age, with a small increase of rCBF values at approximately 12 years of age. The rCBF in the gray matter averages 3 times that in the white matter, except for the first 6 months of life. The global CBF represents 10% to 20% of the global cardiac output for the first 6 months of life, peaks at approximately 55% by 2 to 4 years of age, and finally stabilizes at approximately 15% by 7 to 8 years of age. Specific age-related evolution patterns were identified in the different anatomic areas of the cerebral parenchyma, which could be related to the development of neuroanatomic structures and to the emergence of corresponding cognitive functions. CONCLUSIONS: Quantitative perfusion CT characterization of brain perfusion shows specific age variations. Brain perfusion of each cortical area evolves according to a specific time course, in close correlation with the psychomotor development.

Adolescent↗

Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients.

BACKGROUND AND PURPOSE: Numerous parameters are involved in dynamic perfusion CT (PCT). We assessed the influence of the temporal sampling rate and the volume of contrast material. METHODS: Sixty patients with ischemic hemispheric stroke lasting > or = 12 hours underwent PCT. Groups of 15 patients each received 30, 40, 50, or 60 mL of contrast agent. Regional cerebral blood volume (rCBV), regional cerebral blood flow (rCBF), mean transit time (MTT), and time-to-peak (TTP) maps were calculated for temporal sampling intervals of 0.5, 1, 2, 3, 4, 5, and 6 seconds. Results were statistically compared. Signal-to-noise ratios (SNRs), duration of arterial entrance to venous exit, and radiation dose were also assessed. RESULTS: Increasing temporal sampling intervals lead to significant overestimation of rCBV, rCBF, and TTP and significant underestimation of MTT compared with values for an interval of 1 second. Maximal allowable intervals to avoid these effects were 2, 3, 3, and 4 seconds for 30, 40, 50, and 60-mL boluses, respectively. Venous exit of contrast material occurred in 97.5% of patients after 36, 42, 42, and 48 seconds, respectively, for the four volumes. SNRs did not differ with volume. The effective radiation dose varied between 0.852 and 1.867 mSv, depending on the protocol. The cine mode with two 40-mL boluses and the toggling-table technique with one 60-mL bolus had the lowest doses. CONCLUSION: Temporal sampling intervals greater than 1 second can be used without altering the quantitative accuracy of PCT. Increased sampling intervals reduce the radiation dose and may allow for increased spatial coverage.

Aged↗

Radio-frequency tissue ablation of the liver: in vivo and ex vivo experiments with four different systems.

The aim of this study was to test the efficacy of four different radio-frequency ablation (RFA) systems in normal hepatic parenchyma in large animals. The RFA was applied to pig livers in vivo and to calf livers ex vivo using the Radionics cluster needle, RITA starburst XL needle, Radiotherapeutics Le Veen 4.0 needle, and the Berchtold 14-G saline-perfused 15-mm active-tip needle based on constructor specifications. The volume of tissue coagulation from RF was calculated from measurements of the vertical diameter (Dv) and transverse diameter (Dt). Lesion shape was characterized using the ratio between Dt/Dv. Radiotherapeutics and RITA produced in vivo lesion volume of 42+/-10, 39+/-4 cm3 with a reproducible spherical shape (Dt/Dv of 1.01+/-0.16 and 0.97+/-0.1, respectively). Radionics produced in vivo RF lesions volume of 29+/-11 cm3) with an ovoid shape (Dt/Dv 0.88+/-0.09). The RF lesions with the Berchtold device could not be assessed in vivo as 5 of 8 animals died during treatment. Ex vivo RF lesions had similar volumes with each system; however, the Radiotherapeutics device produced more reproducible shaped lesions than the other systems. In our experimental study, we found no difference between expandable needle systems in vivo. Cooled needles produced slightly smaller and ovoid shape in vivo lesions.

Animals↗

Thoracolumbar spine fractures in patients who have sustained severe trauma: depiction with multi-detector row CT.

PURPOSE: To determine if multi-detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi-detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another's reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi-detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi-detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi-detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi-detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi-detector row CT, respectively, were 145 and 880 US dollars per patient. CONCLUSION: Multi-detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Adult↗

Pulse-inversion harmonic imaging improves lesion conspicuity during US-guided biopsy.

PURPOSE: To assess the feasibility of percutaneous biopsy of low-conspicuity focal liver lesions with use of pulse-inversion harmonic imaging (PIHI) guidance in the late phase after injection of microbubble contrast agent. MATERIALS AND METHODS: Twelve patients referred for ultrasound (US)-guided biopsy had liver lesions lacking adequate conspicuity to undergo biopsy under conventional ultrasound (US) guidance. They underwent biopsy procedures performed with the use of PIHI guidance in the late phase after injection of Levovist. The conspicuity of lesions, procedure time, number of passes, and success and complication rates were documented and compared to a control group. The control group consisted of retrospective analysis of 19 patients who had undergone conventional US-guided biopsy procedures performed by the same radiologist. RESULTS: After contrast material injection, all lesions had sufficient increases in conspicuity to be targeted under PIHI guidance. Procedure time was prolonged in the PIHI group (66 minutes; range, 30-120 min; vs control, 33 min; range, 15-77 min; P <.01, Wilcoxon signed-rank test). The number of passes was greater in the PIHI group (1.9 +/- 0.3; vs control, 1.4 +/- 0.6; P <.01, chi(2) test). No statistically significant difference was observed when comparing success and complication rates. CONCLUSION: PIHI in the late phase after injection of Levovist generated clear delineation of focal liver lesions in all cases, allowing an accurate and safe sampling. This technique broadens the scope of US-guided biopsy to lesions lacking adequate conspicuity on conventional US.

Adult↗

Enterobiliary fistula after radiofrequency ablation of liver metastases.

A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.

Adenocarcinoma↗

Influence of scatter reduction method and monochromatic beams on image quality and dose in mammography.

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.

Computer Simulation↗

Exclusion of pulmonary embolism using C-reactive protein and D-dimer. A prospective comparison.

Our goal was to evaluate the diagnostic utility of C-reactive protein (CRP) alone or combined with clinical probability assessment in patients with suspected pulmonary embolism (PE), and to compare its performance to a D-dimer assay. We conducted a prospective study in which we performed a common immuno-turbidimetric CRP test and a rapid enzyme-linked immunosorbent assay (ELISA) D-dimer test in 259 consecutive outpatients with suspected PE at the emergency department of a teaching hospital. We assessed clinical probability of PE by a validated prediction rule overridden by clinical judgment. Patients with D-dimer levels > or = 500 microg/l underwent a work-up consisting of lower-limb venous ultrasound, spiral computerized tomography, ventilation-perfusion scan, or pulmonary angiography. Patients were followed up for three months. Seventy-seven (30%) of the patients had PE. The CRP alone had a sensitivity of 84% (95% confidence interval [CI).: 74 to 92%) and a negative predictive value (NPV) of 87% (95% CI: 78 to 93%) at a cutpoint of 5 mg/l. Overall, 61 (24%) patients with a low clinical probability of PE had a CRP < 5 mg/l. Due to the low prevalence of PE (9%) in this subgroup, the NPV increased to 97% (95% CI: 89 to 100%). The D-dimer (cutpoint 500 micro g/l) showed a sensitivity of 100% (95% CI: 95 to 100%) and a NPV of 100% (95% CI: 94 to 100%) irrespective of clinical probability and accurately rule out PE in 56 (22%) patients. Standard CRP tests alone or combined with clinical probability assessment cannot safely exclude PE.

Adult↗

Clinical experience with retrievable Günther Tulip vena cava filters.

PURPOSE: To report clinical experience with retrievable Günther Tulip filters from implantation to retrieval and their status in nonretrieved situations. METHODS: Seventy-five Günther Tulip filter implantations were performed in 71 patients (43 women; mean age 55 years). Indications for filter placement were pulmonary embolism (PE) or iliofemoral deep vein thrombosis (DVT) in patients with a contraindication to anticoagulation (43, 61%) or perioperative PE prophylaxis (28, 39%) in patients with confirmed iliofemoral DVT. Retrieval procedures were planned for each patient. Patients with nonretrieved filters were followed with plain radiography and duplex sonography. RESULTS: Technical success of filter insertion was 97.3% (73/75). Eighteen (25%) patients died from unrelated causes prior to retrieval attempts, and 6 other patients were too critically ill for a retrieval procedure. Of 49 (67%) planned retrieval attempts, 14 (19%) filters could not be removed owing to large trapped thrombi. The mean implantation period for the 35 (48%) retrieved filters was 8.2 days (range 1-13). Delivery tilt was observed in 12 (16%) filters and during retrieval attempts in 1 more case. For 9 nonretrieved filters, tilt and migration were observed in 22% at a mean follow-up of 30 months, but no venous thrombosis was assessed. CONCLUSIONS: Our data confirm the clinical efficacy of the Günther Tulip filter during implantation and the feasibility of its retrieval. Further long-term follow-up should be conducted on nonretrieved filters to confirm our results.

Adult↗

Prevention of atelectasis formation during induction of general anesthesia.

UNLABELLED: General anesthesia promotes atelectasis formation, which is augmented by administration of large oxygen concentrations. We studied the efficacy of positive end-expiratory pressure (PEEP) application during the induction of general anesthesia (fraction of inspired oxygen [FIO(2)] 1.0) to prevent atelectasis. Sixteen adult patients were randomly assigned to one of two groups. Both groups breathed 100% O(2) for 5 min and, after a general anesthesia induction, mechanical ventilation via a face mask with a FIO(2) of 1.0 for another 5 min before endotracheal intubation. Patients in the first group (PEEP group) had continuous positive airway pressure (CPAP) (6 cm H(2)O) and mechanical ventilation via a face mask with a PEEP of 6 cm H(2)O. No CPAP or PEEP was applied in the control group. Atelectasis, determined by computed radiograph tomography, and analysis of blood gases were measured twice: before the beginning of anesthesia and directly after the intubation. There was no difference between groups before the anesthesia induction. After endotracheal intubation, patients in the control group showed an increase of the mean area of atelectasis from 0.8% +/- 0.9% to 4.1% +/- 2.0% (P = 0.0002), whereas the patients of the PEEP group showed no change (0.5% +/- 0.6% versus 0.4% +/- 0.7%). After the intubation with a FIO(2) of 1.0, PaO(2) was significantly higher in the PEEP group than in the control (591 +/- 54 mm Hg versus 457 +/- 99 mm Hg; P = 0.005). Atelectasis formation is prevented by application of PEEP during the anesthesia induction despite the use of large oxygen concentrations, resulting in improved oxygenation. IMPLICATIONS: Application of positive end-expiratory pressure during the induction of general anesthesia prevents atelectasis formation. Furthermore, it improves oxygenation and probably increases the margin of safety before intubation. Therefore, this technique should be considered for all anesthesia induction, at least in patients at risk of difficult airway management during the anesthesia induction.

Adolescent↗

Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiography.

OBJECT: The goal of this study was to assess the diagnostic accuracy of computerized tomography (CT) angiography performed with the aid of multislice technology (MSCT angiography) in the investigation of intracranial aneurysms, by comparing this method with intraarterial digital subtraction (IADS) angiography. METHODS: Fifty consecutive adult patients, who successively underwent MSCT angiography (four rows) and IADS angiography of intracranial vessels, were prospectively identified. The MSCT angiography studies consisted of 1.25-mm slices, with 0.8-mm reconstruction intervals, a pitch of 0.75, and timing determined by a test bolus. Two neuroradiologists, who were blinded to the initial interpretation of the MSCT angiograms as well as to those of the IADS angiograms, independently reviewed the MSCT angiograms for the detection and characterization of intracranial aneurysms. Forty-nine intracranial aneurysms were identified in 40 patients; 33 of these lesions were responsible for subarachnoid hemorrhage. The sensitivity, specificity, and accuracy of MSCT angiography in the detection of intracranial aneurysms were 94.8, 95.2, and 94.9%, respectively, on a per-aneurysm basis and 99, 95.2, and 98.3%, respectively, on a per-patient basis. Interobserver agreement was 98%. There was an excellent correlation between aneurysm size assessed using MSCT angiography and that determined by IADS angiography (slope = 0.916, r = 0.877, p < 0.001); however, 2 mm stood as the cutoff size below which the sensitivity of MSCT angiography was statistically lower. That method displayed great accuracy in characterizing the morphological characteristics of the aneurysm. CONCLUSIONS: Multislice CT angiography is an accurate and robust noninvasive screening test for intracranial aneurysms. It performs better than that reported for single-slice CT angiography. Introduction of eight- and especially 16-row MSCT angiography will provide further progression through thinner slices, a lower pitch, and a purely arterial phase.

Angiography, Digital Subtraction↗

Prospective comparison of MR enteroclysis with multidetector spiral-CT enteroclysis: interobserver agreement and sensitivity by means of "sign-by-sign" correlation.

Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.

Artifacts↗