PubMed Health⌕ Search

Biomedical subjects

Piet Claus

Publications and source records attributed to Piet Claus.

25 records · Page 2Linked to original sources

Defining the transmurality of a chronic myocardial infarction by ultrasonic strain-rate imaging: implications for identifying intramural viability: an experimental study.

BACKGROUND: In a correlative functional/histopathologic study, we investigated the regional deformation characteristics of both chronic nontransmural and transmural infarctions before and after a dobutamine challenge. METHODS AND RESULTS: After stenosing copper-coated stent implantation to produce circumflex artery endothelial proliferation, 18 pigs were followed up for 5 weeks. Posteuthanasia histology showed 10 to have a nontransmural and 8 a transmural infarction. Eight nonstented animals served as controls. Regional radial function was monitored by measuring ultrasound-derived peak systolic strain rates (SR(SYS)) and systolic strains (epsilon(SYS)) (1) before stent implantation and (2) at 5 weeks, at baseline (bs) and during an incremental dobutamine infusion. In controls, dobutamine induced a linear increase in SR(SYS) (dobutamine: bs, 4.8+/-0.4 s(-1); 20 microg x kg(-1) x min(-1), 9.9+/-0.7 s(-1); P<0.0001) and an initial increase of epsilon(SYS) at low dose (bs, 58+/-5%; at 5 microg x kg(-1) x min(-1), 78+/-6%; P<0.05) but a subsequent decrease during higher infusion rates. In the nontransmural group, bs SR(SYS) and epsilon(SYS) were significantly lower than prestent values (SR(SYS), 2.9+/-0.5 s(-1) and epsilon(SYS), 32+/-6%, P<0.05 versus prestent). During dobutamine infusion, SR(SYS) increased slightly at 5 microg x kg(-1) x min(-1) (4.7+/-0.6 s(-1), P<0.05) but fell during higher infusion rates, whereas epsilon(SYS) showed no change. For nontransmural infarctions, transmural scar extension correlated closely with epsilon(SYS) at bs (r=0.88). For transmural infarctions, SR(SYS) at bs was significantly reduced and epsilon(SYS) was almost not measurable (SR(SYS), 1.8+/-0.3 s(-1); epsilon(SYS), 3+/-4%). Both deformation parameters showed no further change during the incremental dobutamine infusion. CONCLUSIONS: Ultrasonic deformation values could clearly differentiate chronic nontransmural from transmural myocardial infarction. The transmural extension of the scar could be defined by the regional deformation response.

Animals↗

One-dimensional ultrasonic strain and strain rate imaging: a new approach to the quantitation of regional myocardial function in patients with aortic stenosis.

Abnormalities in regional left ventricular (LV) function in aortic stenosis (AS) have yet to be appropriately characterized. One-dimensional strain (epsilon) and strain rate imaging (SRI), new ultrasound (US) indices for quantifying regional wall deformation, might allow this. The aims of this study were 1. to define regional radial and longitudinal epsilon /SR in AS; 2. to establish if they are related to the severity of the disease; and 3. to determine if regional deformation is further altered by coexistent coronary artery disease (CAD). A total of 40 patients were studied: Group I with isolated AS (10 women, 10 men; mean age 66 years) and group II with AS and concomitant CAD (CAD/AS) (13 women, 7 men, mean age 68 years). Data were compared to 20 age-matched healthy people (N). Regional systolic maximal velocity/SR and end-systolic and maximal epsilon were measured. The maximal systolic velocity/SR in AS and CAD/AS patients were significantly reduced compared to N. The two patient groups could be further differentiated by end-systolic and maximal epsilon, which demonstrated a further reduction in both epsilon indices in CAD/AS (i.e., maximal radial epsilon 29.3%, AS; 23.7%, CAD/AS; 40.4%, N; AS and CAD/AS vs. N, AS vs. CAD/AS, p < 0.05). Indices of radial and longitudinal deformation correlated both with aortic valve area (AVA) and stroke volume (SV) (i.e., radial maximal epsilon and AVA, r = 0.77, p < 0.05). A significant correlation was also found between epsilon indices and the severity of left anterior descending (LAD) or circumflex artery (CX) coronary artery. Regional myocardial deformation in AS is abnormal. In the absence of CAD, the degree of abnormality correlates with aortic valve area (AVA). The severity of the disease was best expressed by changes in regional epsilon. In CAD/AS patients, there was a significant further reduction in end-systolic and maximal epsilon. These changes correlated with the severity of coronary narrowing in the subtending vessel.

Adult↗

Can regional strain and strain rate measurement be performed during both dobutamine and exercise echocardiography, and do regional deformation responses differ with different forms of stress testing?

BACKGROUND: Regional strain (epsilon) and strain rate (SR) measurement could be the optimal approach to quantifying stress echocardiography images. However, signal noise could preclude their use. Study aims Our aim was to compare the feasibility of regional peak systolic (p) velocity (Vel), pSR/epsilon measurement, and their normal responses during upright (group 1, n = 10) and supine (group 2, n = 10) bicycle exercise and (group 3, n = 10) dobutamine stress. METHODS: For each type of stress study, pVel/pSR/epsilon data were acquired at baseline, low (100-120 bpm), and peak (140-160 bpm) heart rate (HR); and during recovery. RESULTS: During dobutamine pVel/pSR/epsilon were interpretable in >95% of segments at every stress stage, whereas in groups 1 and 2 pSR/epsilon responses were noninterpretable in >36% of segments (P <.0002). The highest proportions of data exclusions were from the lateral and anterior walls. In all groups, regional systolic pVel and SR values increased linearly and reached maximal value at peak HR (P <.0006 vs baseline). Pepsilon showed a biphasic response, initially increasing at low HR, and then remaining constant or falling at peak HR. CONCLUSION: PSR/pepsilon quantification of stress echocardiography may currently be restricted to dobutamine as increased signal noise precludes adequate data acquisition during exercise. For all forms of stress both pSR and pVel increased linearly, whereas pepsilon response was biphasic as a result of the reduced filling at higher HRs.

Adult↗

Differential changes in regional right ventricular function before and after a bilateral lung transplantation: an ultrasonic strain and strain rate study.

The evaluation of regional right ventricular function by ultrasound remains a challenge. This case report demonstrates the potential value of the new cardiac deformation indices, strain and strain rate imaging, in determining the differing regional abnormalities in longitudinal right ventricular function before and after bilateral lung transplantation. These indices were measured in a patient with severe right ventricular dysfunction as a result of primary pulmonary hypertension.

Adult↗

Quantification of regional right and left ventricular function by ultrasonic strain rate and strain indexes after surgical repair of tetralogy of Fallot.

The quantification of regional myocardial function in tetralogy of Fallot (TOF) by conventional M-mode and 2-dimensional echocardiography is difficult because of the complex right ventricular (RV) and altered left ventricular (LV) geometry. In 30 asymptomatic postoperative TOF patients (aged 4 to 16 years) with a low pressure in the right ventricle and with varying degrees of pulmonary regurgitation and in 30 aged-matched healthy children, the ultrasonic-derived regional deformation parameters peak systolic strain rate (SR) and systolic strain (epsilon) were acquired from ventricles and compared. In TOF RV free walls, SR, and epsilon were reduced in the basal, mid-, and apical segments and averaged -1.5 +/- 0.6 second(-1) for SR and -22 +/- 8% for epsilon, respectively (p <0.001 vs normals). Peak systolic SR of the basal RV free wall correlated significantly with the QRS duration of the electrocardiogram (r = 0.81, p <0.0001). Abnormalities in RV deformation were more marked in patients with transannular patches versus infundibular patches. In the septum there was a homogeneous reduction in SR and epsilon in the basal, mid-, and apical segments. These averaged -1.4 +/- 0.3 second(-1) for SR and -19 +/- 4% for epsilon, respectively (p <0.01 vs normals). Longitudinal SR and epsilon values of the 3 LV lateral wall segments (averaged SR = -1.6 +/- 0.4 second(-1), averaged epsilon = -20 +/- 5%; p <0.05 vs normals), and radial SR and epsilon of the LV posterior wall (SR = 3.3 +/- 0.9 second(-1); epsilon = 51 +/- 14%; p <0.05 vs normals) were significantly reduced. Thus, abnormalities in regional RV and LV systolic myocardial function in asymptomatic postoperative TOF patients were quantified by the deformation parameters SR and epsilon. RV deformation abnormalities are associated with electrical depolarization abnormalities.

Adolescent↗

Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate.

For porcine myocardium, ultrasonic regional deformation parameters, systolic strain (epsilon(sys)) and peak systolic strain rate (SR(sys)), were compared with stroke volume (SV) and contractility [contractility index (CI)] measured as the ratio of end-systolic strain to end-systolic wall stress. Heart rate (HR) and contractility were varied by atrial pacing (AP = 120-180 beats/min, n = 7), incremental dobutamine infusion (DI = 2.5-20 microg. kg(-1). min(-1), n = 7), or continuous esmolol infusion (0.5 mg. kg(-1). min(-1)) + subsequent pacing (120-180 beats/min) (EI group, n = 6). Baseline SR(sys) and epsilon(sys) averaged 5.0 +/- 0.4 s(-1) and 60 +/- 4%. SR(sys) and CI increased linearly with DI (20 microg. kg(-1). min(-1); SR(sys) = 9.9 +/- 0.7 s(-1), P < 0.0001) and decreased with EI (SR(sys) = 3.4 +/- 0.1 s(-1), P < 0.01). During pacing, SR(sys) and CI remained unchanged in the AP and EI groups. During DI, epsilon(sys) and SV initially increased (5 microg. kg(-1). min(-1); epsilon(sys) = 77 +/- 6%, P < 0.01) and then progressively returned to baseline. During EI, SV and epsilon(sys) decreased (epsilon(sys) = 38 +/- 2%, P < 0.001). Pacing also decreased SV and epsilon(sys) in the AP (180 beats/min; epsilon(sys) = 36 +/- 2%, P < 0.001) and EI groups (180 beats/min; epsilon(sys) = 25 +/- 3%, P < 0.001). Thus, for normal myocardium, SR(sys) reflects regional contractile function (being relatively independent of HR), whereas epsilon(sys) reflects changes in SV.

Adrenergic beta-Antagonists↗