PubMed Health⌕ Search

Biomedical subjects

Piet Meijer

Publications and source records attributed to Piet Meijer.

15 recordsLinked to original sources

Pyoderma gangrenosum after caesarean section: a case report.

BACKGROUND: Pyoderma gangrenosum is a rare ulcerative skin disease. The diagnosis is based on clinical features and excluding other causes of skin ulcers, as it does not have characteristic histopathology or laboratory findings. The etiology is poorly understood. Lesions can develop spontaneously, after surgery or after trauma. CASE PRESENTATION: We present the case of a 32-year-old woman with ulcerative wound defect after caesarean section. The wound was not healing despite standard wound care and antibiotic treatment. Pyoderma gangrenosum was diagnosed and after high dose corticosteroids wound healing started. CONCLUSION: Early diagnosis and subsequent treatment of pyoderma gangrenosum are crucial for limiting scar tissue. Diagnosis of pyoderma gangrenosum could easily be missed since gynaecologists are rarely confronted with this disorder.

Journal Article↗

Comparative effects of a contraceptive vaginal ring delivering a nonandrogenic progestin and continuous ethinyl estradiol and a combined oral contraceptive containing levonorgestrel on hemostasis variables.

OBJECTIVE: This study aimed to compare the effects on hemostasis variables of a contraceptive vaginal ring with those of an oral contraceptive. STUDY DESIGN: Twenty-three and 22 healthy premenopausal women were randomized to the contraceptive vaginal ring (150 microg Nestorone and 15 microg ethinyl estradiol) or Stediril 30 during 3 cycles. Analysis of covariance was performed with baseline values as covariate. RESULTS: The contraceptive vaginal ring changed most hemostasis variables similarly but raised (95% confidence intervals of percent treatment differences) Factor VIIt (28% to 49%), extrinsic activated protein C resistance (14% to 65%), and sex hormone-binding globulin (117% to 210%) and lowered Protein S (-32% to -16%) and the global activated partial thromboplastin time-based activated protein C resistance (-12% to -2%) more than the oral contraceptive. CONCLUSION: The contraceptive vaginal ring affected some measured hemostasis variables and sex hormone-binding globulin differently from the oral contraceptive, most likely because of difference in androgenicity of the progestins. The results suggest that the contraindications for oral contraceptive use would also apply to the tested contraceptive vaginal ring.

Activated Protein C Resistance↗

An external quality assessment program for von Willebrand factor laboratory analysis: an overview from the European concerted action on thrombosis and disabilities foundation.

The laboratory diagnosis of von Willebrand disease (vWD) is complex and requires a panel of different laboratory tests. Because of this complexity, a proper quality control process is necessary. Since 2003, the European Concerted Action on Thrombosis and Disabilities Foundation has provided an external quality control program for several laboratory tests included in the diagnosis of vWD. Currently, ~180 different laboratories participate in this program, of which the vast majority perform both von Willebrand factor (vWF):antigen (Ag) and activity tests. The lowest between-laboratory variation was observed for the vWF antigen assay (10 to 24%), with a better performance for the latex immunoassay (8 to 24%) than the enzyme immunoassay (13 to 25%). Both the ristocetin cofactor activity assay (RCo) and the collagen-binding assay showed a higher between-laboratory variation (20 to 40% and 17 to 29%, respectively). We have observed that the within-laboratory repeatability for normal samples ranged from 0 to 40% for the antigen assay and from 0 to 86% for the ristocetin cofactor activity assay. Normal samples were interpreted correctly by the majority of the participants. However, type 1 vWD samples were wrongly interpreted by 20 to 40% of the participants, which was mainly caused by a discordance in the vWF:RCo/vWF:Ag ratio. It can be concluded that further improvement in the laboratory diagnosis of vWD is necessary.

Clinical Laboratory Techniques↗

Effect of garlic powder on C-reactive protein and plasma lipids in overweight and smoking subjects.

BACKGROUND: Epidemiologic studies suggest that garlic may have beneficial effects on risk factors associated with cardiovascular disease (CVD). However, these findings are not unambiguously supported by randomized placebo-controlled clinical trials. OBJECTIVE: We sought to investigate the effects of a chemically well-characterized garlic preparation on biomarkers for inflammation, endothelial function, and lipid metabolism in subjects with risk factors for CVD. DESIGN: This was a double-blind, randomized, placebo-controlled trial in 90 overweight [body mass index (in kg/m2) > 24.5] subjects aged 40-75 y who smoked >10 cigarettes/d. The subjects were randomly assigned to 3 parallel treatment groups: garlic powder (2.1 g/d), atorvastatin (40 mg/d), or placebo. Duplicate measurements were performed at baseline and after 1 and 3 mo of treatment. Treatments were compared with analysis of covariance with baseline as the covariate, and differences between the treatments were reported as mean percentage difference and corresponding 97.5% CI. RESULTS: None of the variables showed significant differences between the garlic-treated and the placebo groups. In contrast, compared with the placebo group, atorvastatin treatment resulted in significantly lower plasma concentrations of C-reactive protein (20.2%; 1.7%, 35.3%), total cholesterol (37.2%; 33.1%, 41.1%), LDL cholesterol (52.7%; 47.9%, 57.1%), triacylglycerols (31.9%; 20.8%, 41.5%), and tumor necrosis factor alpha (TNF-alpha; 41.9%; 19.0%, 58.3%) and increased the ratio of ex vivo whole blood lipopolysaccharide-stimulated to nonstimulated TNF-alpha concentrations (109.7%; 37.9%, 218.9%). CONCLUSION: We conclude that a chemically well-characterized garlic preparation has no significant effect on inflammatory biomarkers, endothelial function, or lipid profile in normolipidemic subjects with risk factors for CVD.

Adult↗

A model for the harmonisation of test results of different quantitative D-dimer methods.

The numerical test results of different D-dimer assays vary widely. Because of the complexity of the analyte of target as well as the variability in specificity of different D-dimer assays, only harmonisation of the test results seems to be feasible. The use of a single conversion factor does not take into account for several methods the lack of commutability between test results and consensus values at different D-dimer levels. This is probably related to the mutually different response of methods to high and low levels. We therefore designed a harmonisation model based on the transformation of a method-specific regression line to a reference regression line. We used the data for the measurement of a set of plasma samples with different D-dimer levels by 353 different laboratories using 7 of the most frequently used quantitative D-dimer methods. For each method we calculated the method-specific consensus value for each sample. The overall median value was also estimated. Per method linear regression was applied throughout the method-specific consensus values using the amount of patient pooled plasma added to the different plasma samples as the independent variable. The line through the overall median values of all 7 methods was used as the reference line. Harmonisation between the methods was obtained by transformation of the method-specific regression line to the reference line. This harmonisation resulted in a reduction of the variability between the method-specific consensus values from about 75% to about 5.5%. Clinical validation of this concept had shown significant improvement of the test result comparability. We conclude that this model is a feasible approach in the harmonisation of D-dimer methods. If the harmonisation procedure is included in the calibration procedure by the manufacturers, customers will automatically obtain harmonised test results.

Biomarkers↗

Genetic influences on fibrinogen, tissue plasminogen activator-antigen and von Willebrand factor in males and females.

Differences in genetic influence on death from CHD between males and females have been reported. Haemostatic factors have consistently been associated with risk for coronary heart disease (CHD), but sex differences in genetic architecture have not been studied. This study in middle-aged twins investigates whether there are sex differences in means and in genetic and/or environmental variance components of haemostatic risk factors for CHD. A total of 93 monozygotic twin pairs (44 male and 49 female) and 116 dizygotic twin pairs (36 male, 40 female and 40 opposite sex) were available for this study. Structural equation modelling was used to estimate the relative influence of genetic and environmental factors on variation in levels of fibrinogen, tissue plasminogen activator (tPA) antigen and von Willebrand factor (vWF). Mean levels of tPA and vWF increased with age. Oral contraceptive pill (OCP) and menopause had significant influences on levels of fibrinogen and tPA. Genetic influences explained 39, 66 and 72% of the variation in levels of fibrinogen, tPA and vWF, respectively. No quantitative or qualitative differences of genetic influences on haemostatic levels were seen between males and females. Haemostatic factors may account for a significant part of the genetic risk for cardiovascular disease. No difference in genetic architecture for levels of fibrinogen, tPA or vWF was observed between males and females.

Adult↗

A national field study of quality assessment of CoaguChek point-of-care testing prothrombin time monitors.

A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by experienced staff at 9 Netherlands Thrombosis Centers and results compared with certified INR. A 15% or more deviation has been classified as significant deviation. Overall mean and certified INR values were similar, but 20.3% of participants showed a 15% or more deviation from the certified INR on at least 1 of the 5 QA plasma samples. Statistically significant differences in results with different lots of CoaguChek test strips were found. There is need for large scale QA of CoaguChek monitors. The importance of the 5 CoaguChek certified INR QA plasma samples being tested on a single occasion is demonstrated.

International Normalized Ratio↗

Performance goals for the laboratory testing of antithrombin, protein C and protein S.

To achieve a reliable analytical quality for both monitoring and diagnostic testing, laboratories need to fulfil the widely accepted analytical performance goals based on the biological variation of the analytes of testing. Not only is the short-term analytical performance, which regularly is assessed by internal quality control procedures, of importance, but also the long-term analytical performance. To assess the long-term analytical performance, data obtained from an external quality assessment programme can be used. In this study we have used the evaluation model designed by the ECAT Foundation for the assessment of the longterm analytical performance, including imprecision, bias and total analytical error. The model was applied to the data from 136 different laboratories for the assay of antithrombin (activity), protein C (activity and antigen) and protein S (activity, total and free antigen). The imprecision (median; range), reflected by the long-term analytical coefficient of variation (LCV (A) ), was the lowest for antithrombin (7.6%; 2.6 - 43.8%) and the highest for protein S activity (17.2%; 4.3 - 88.6%). For bias and total error the same pattern was observed (antithrombin: 3.8%; 0.3 - 17.1% and 9.1%; 3.4 - 34.3%, respectively; protein S activity: 12.8%; 3.1 - 34.8% and 24.5%; 9.9 - 87.0%, respectively). For the majority of the laboratories (70 - 85%) the imprecision contributes considerably more to the total error than the bias. However the effect of the bias on the analytical quality is not negligible. Assays for antithrombin, protein C and protein S are mainly used for diagnostic testing. About 70 - 100% of the laboratories can fulfil the desirable performance goal for imprecision. The desirable performance goal for bias was reached by 50 - 95% of the laboratories. In all cases the highest numbers of laboratories fulfilling performance goals was obtained for the protein C variables. To improve the analytical quality in assays of antithrombin, protein C and protein S it is highly recommended that primarily imprecision (non-systematic failures) be suppressed. However the effect of the bias (systematic failures) on the analytical quality should not be neglected. A useful tool for determining the imprecision (LCV (A) ) and bias is the long-term analytical performance evaluation model as used by the ECAT Foundation.

Antithrombin III↗

External quality assessment and the laboratory diagnosis of thrombophilia.

External quality assessment is a tool to compare the result of a particular laboratory test in relation to those of other laboratories as well as to assess the performance of a laboratory test over a prolonged period of time. We evaluated the relationship between the between-laboratory variation and the sample category (normal, borderline, and abnormal) for antithrombin, protein C, protein S, and the activated protein C resistance test. Only for antithrombin and protein S was a significant relationship (0.004 < p < 0.012) observed. The effect of the between-laboratory variation of the different sample categories on the clinical interpretation was investigated. With the exception of free protein S antigen, all variables showed a significant relationship (0.004 < p < 0.045) between the sample category and the percentage of misclassification. Because in clinical practice a stable test performance over a prolonged period of time is important, we evaluated the quality of test performance using the long-term analytical coefficient of variation (LCVa). A wide range in the LCVa was observed for antithrombin, protein C, and protein S. Less than half of the participants could fulfill the quality specification for diagnostic testing (LCVa < or = 0.58 x total biological variation). This study shows that a more stable performance of laboratory tests involved in the screening of thrombophilia over a prolonged period of time is necessary.

Antithrombins↗

The performance of quantitative D-dimer assays in laboratory routine.

Assessment of D-dimer in plasma is routinely used for the exclusion of venous thrombosis and the monitoring of hypercoagulability. Little information is available about the performance of D-dimer assays in clinical laboratories examined by external quality assessment schemes. We obtained results from 423 laboratories measuring plasma pools from patients with elevated D-dimer levels mixed with human normal plasma. The results from five samples were reported containing D-dimer from the lower normal range up to a 20-fold increased level. In addition, information about the assignment of a cut-off point and the medical need to apply these assays was obtained by standardized questionnaire. Participants reported results and additional information from 20 different assays. Lack of standardization regarding the calibration concepts obstructs comparability of results. Results in one sample varied up to 20-fold between the assays applied. In addition, a high variability was reported around the cut-off values introduced for the exclusion of venous thrombosis and pulmonary embolism. As a consequence, generally accepted cut-off values cannot be established. For cut-off assignment, 62% of participants used the kit insert but also 14% used local validation. In conclusion, standardization or at least harmonization of D-dimer assays is necessary to ensure comparability of D-dimer plasma levels measured in clinical routine.

Blood Chemical Analysis↗

Protein S assays: an analysis of North American Specialized Coagulation Laboratory Association proficiency testing.

To assess current laboratory practice and the performance of different reagent-instrument combinations for protein S testing, protein S results from the North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency testing surveys for 2002 and the first half of 2003 were analyzed. A written survey of NASCOLA laboratories also was performed to further assess current laboratory practices for protein S testing. The free protein S antigen assays and the Diagnostica Stago Staclot protein S assay were extremely accurate in detecting a heterozygous type I protein S deficiency. Another functional protein S assay and most total protein S assays were less reliable, depending to some extent on the instrument. All assays used by NASCOLA laboratories appropriately identified normal protein S specimens. NASCOLA laboratories performed at least as well as European Concerted Action on Thrombosis laboratories in the proficiency tests. The results suggest that the diagnosis of heterozygous protein S deficiency may be problematic with some currently available assays. Many total protein S antigen assays do not add to the diagnosis and can be unreliable for protein S deficiency subtyping. Better standardization of functional and antigenic assays is needed.

Biological Assay↗

Genetics of dizygotic twinning: a feasibility study for a biobank.

To locate the genes that make a substantial contribution to variation in natural dizygotic twinning in humans, large-scale studies are needed. New studies should not stop at DNA genotyping, but collect material that allow gene-expression analysis, transcriptomics, proteomics and endocrinology. In this article we describe a pilot study to examine the feasibility, effectiveness and logistics of large-scale nationwide sample collection in Dutch families in which two or more sisters have given birth to spontaneous dizygotic twins. Pedigree data and addresses from family members of proband mothers were collected by telephone. Blood and urine samples were collected during a home visit, and handled in the afternoon. All participants were bled between 7 a.m. and 10 a.m. after overnight fasting. Blood samples of fertile women with a natural cycle were collected on the second, third or fourth day of their menstrual cycle. The effects of transportation and storage on blood quality, lipids, RNA with and without challenge, lymphocytes and other parameters were examined. Genomic DNA was isolated from blood and cells were immortalized using Epstein-Barr virus. In 78.6% of the women with a natural cycle blood samples were collected on the second, third or fourth day of the menstrual cycle. This percentage is likely to increase with the more dense geographical distribution of participants in the larger population. We conclude that the pilot study demonstrated the feasibility of this protocol to collect good quality of plasma, DNA, RNA and lymphocyte samples by home visits.

DNA↗

Diagnostic strategies for C-reactive protein.

BACKGROUND: Serum C-reactive protein (CRP) has been identified in prospective epidemiological research as an independent risk marker for cardiovascular disease. In this paper, short-term biological variation of CRP is documented and a strategy to test the reliability of a single CRP sample is proposed. METHODS: Data were obtained from three groups of healthy volunteers: men, no oral contraceptives (OC-)using women and OC-using women. Blood samples were obtained 3 times in men and twice in women during a workweek. RESULTS AND DISCUSSION: CRP values were highest in the OC-using women, followed by the men, and lowest in the no OC-using women. Averaged over the three groups the within-subject coefficients of variation (CVi) was 49.24% for CRP, and 29.90% for lnCRP. Using the repeated measures, individual samples were identified that reflected a 'suspicious' unreliable high value, i.e. a value that was more than 2 standard deviations higher than the lowest value obtained from the same subject. In an a posteriori analysis, three strategies to identify these suspicious high CRP values were then tested. In terms of maximizing detection of suspicious values and minimizing unnecessary resampling, best results were obtained for the most pragmatic criterion of using an absolute level, stratified for gender, and OC-use, to decide whether a second sample should be obtained. CONCLUSION: A single high CRP value must be followed by re-sampling when it is above 1.75 mg/l for men, above 1.00 mg/l for no OC-using women, and above 2.00 mg/l for OC-using women.

Adult↗

Long-term analytical performance of hemostasis field methods as assessed by evaluation of the results of an external quality assessment program for antithrombin.

BACKGROUND: It is important for a laboratory to know the stability of performance of laboratory tests over time. The aim of this study was to adapt from the field of clinical chemistry a method to assess the long-term analytical performance of hemostasis field methods. METHODS: The linear regression model was used to compare the laboratory results with the consensus mean value of a survey. This model was applied to plasma antithrombin activity using the data for 82 laboratories, collected between 1996 and 1999 in the European Concerted Action on Thrombosis (ECAT) external quality assessment program. The long-term total, random, and systematic error were calculated. The variables introduced to define the long-term performance in this model were the long-term analytical CV (LCV(a)) and the analytical critical difference (ACD), which indicates the minimum difference necessary between two samples measured on a long-term time-scale to consider them statistically significantly different. RESULTS: The systematic error (bias) ranged from 4.5 to 103 units/L. The random error ranged from 24.4 to 242 units/L. For the majority of the laboratories, random error was the main component (>75%) of the total error. The LCV(a), after adjustment for the contribution of the bias, ranged from 2.8% to 48%. The ACD ranged from 78 to 1290 units/L with a median value of 190 units/L. No statistically significant differences were observed for either LCV(a) or ACD between the two different measurement principles for antithrombin activity based on the inhibition of either thrombin or factor Xa. CONCLUSIONS: This linear regression model is useful for assessing the total error, random error, and bias for hemostasis field methods. The LCV(a) and ACD for measurement on a long-term time-scale appear to be useful for assessing the long-term analytical performance.

Antithrombins↗