Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging.

OBJECTIVES: The aim of this study was to perform a head-to-head comparison between multi-slice computed tomography (MSCT) and myocardial perfusion imaging (MPI) in patients with an intermediate likelihood of coronary artery disease (CAD) and to compare non-invasive findings to invasive coronary angiography. BACKGROUND: Multi-slice computed tomography detects atherosclerosis, whereas MPI detects ischemia; how these 2 techniques compare in patients with an intermediate likelihood of CAD is unknown. METHODS: A total of 114 patients, mainly with intermediate likelihood of CAD, underwent both MSCT and MPI. The MSCT studies were classified as having no CAD, nonobstructive (<50% luminal narrowing) CAD, or obstructive CAD. Myocardial perfusion imaging examinations were classified as showing normal or abnormal (reversible and/or fixed defects). In a subset of 58 patients, invasive coronary angiography was performed. RESULTS: On the basis of the MSCT data, 41 patients (36%) were classified as having no CAD, of whom 90% had normal MPI. A total of 33 patients (29%) showed non-obstructive CAD, whereas at least 1 significant (> or =50% luminal narrowing) lesion was observed in the remaining 40 patients (35%). Only 45% of patients with an abnormal MSCT had abnormal MPI; even in patients with obstructive CAD on MSCT, 50% still had a normal MPI. In the subset of patients undergoing invasive angiography, the agreement with MSCT was excellent (90%). CONCLUSIONS: Myocardial perfusion imaging and MSCT provide different and complementary information on CAD, namely, detection of atherosclerosis versus detection of ischemia. As compared to invasive angiography, MSCT has a high accuracy for detecting CAD in patients with an intermediate likelihood of CAD.

Aged↗

In situ determination of solidosity profiles during activated sludge electrodewatering.

Two non-invasive techniques were evaluated for the on-line measurement of sludge solidosity profiles during both pressure and electrodewatering operations. In a first approach, a radioactive tracer adsorbed onto the sludge solids was monitored by a gamma camera. Although this technique appeared very flexible in use, the lack of resolution highly limited its usefulness for (electro)dewatering experiments. Improvement in gamma camera resolution by the development of new detectors might, however, increase the future applicability of this technique. In a second technique, nuclear magnetic resonance measurements on a specially designed electrodewatering unit were made. Hereby, reliable on-line measurements of the solidosity profiles of activated sludge during electrodewatering could be made, with a resolution of less than 1mm. Thus, the mechanisms of electroosmotic- and pressure-driven cake dewatering could be illustrated. Given the measurement time required for measuring one sludge profile, both techniques appeared mainly suited for slowly varying processes, such as activated sludge expression, and not for fast changing processes, such as the initial phases of sludge filtration.

Electrochemistry↗

Comparison among tomographic radionuclide ventriculography algorithms for computing left and right ventricular normal limits.

BACKGROUND: Various algorithms have been developed to compute right ventricular (RV) and left ventricular (LV) end-diastolic volumes, end-systolic volumes, and ejection fractions (EF) from tomographic radionuclide ventriculography (TRV). The aims of this investigation were to establish sex-specific normal limits, to determine whether different algorithms produce the same normal values, and to compare TRV normal limits vs for magnetic resonance imaging values in the literature. METHODS: Fifty-one healthy volunteers (29 men, 22 women) were studied prospectively. All subjects had normal electrocardiograms and echocardiographic examinations, and underwent both planar radionuclide ventriculography and TRV. Four algorithms were used to process TRV data. RESULTS: Normal limits for most functional parameters differed significantly from one algorithm to another. Volumes were greater in men, but no statistically significant differences were found between men and women for LV EF or RV EF values for any method. Normal LV and RV EF and volumes were largely consistent with the literature for cardiac magnetic resonance imaging. CONCLUSIONS: Ventricular measurements differ significantly among TRV algorithms. Therefore, it is important to apply sex-specific normal limits that are specific to a given TRV algorithm in interpreting LV and RV EF and volume measurements for each patient.

Adult↗

Intracoronary injection of CD133-positive enriched bone marrow progenitor cells promotes cardiac recovery after recent myocardial infarction: feasibility and safety.

BACKGROUND: Bone marrow CD133-positive (CD133+) cells possess high hematopoietic and angiogenic capacity. We tested the feasibility, safety, and functional effects of the use of enriched CD133+ progenitor cells after intracoronary administration in patients with recent myocardial infarction. METHODS AND RESULTS: Among 35 patients with acute myocardial infarction treated with stenting, 19 underwent intracoronary administration of CD133+ progenitor cells (12.6+/-2.2 x 10(6) cells) 11.6+/-1.4 days later (group 1) and 16 did not (group 2). At 4 months, left ventricular ejection fraction increased significantly in group 1 (from 45.0+/-2.6% to 52.1+/-3.5%, P<0.05), but only tended to increase in case-matched group 2 patients (from 44.3+/-3.1% to 48.6+/-3.6%, P=NS). Likewise, left ventricular regional chordae shortening increased in group 1 (from 11.5+/-1.0% to 16.1+/-1.3%, P<0.05) but remained unchanged in group 2 patients (from 11.1+/-1.1% to 12.7+/-1.3%, P=NS). This was paralleled by reduction in the perfusion defect in group 1 (from 28.0+/-4.1% to 22.5+/-4.1%, P<0.05) and no change in group 2 (from 25.0+/-3.0% to 22.6+/-4.1%, P=NS). In group 1, two patients developed in-stent reocclusion, 7 developed in-stent restenosis, and 2 developed significant de novo lesion of the infarct-related artery. In group 2, four patients showed in-stent restenosis. In group 1 patients without reocclusion, glucose uptake shown by positron emission tomography with 18fluorodeoxyglucose in the infarct-related territory increased from 51.2+/-2.6% to 57.5+/-3.5% (P<0.05). No stem cell-related arrhythmias were noted, either clinically or during programmed stimulation studies at 4 months. CONCLUSIONS: In patients with recent myocardial infarction, intracoronary administration of enriched CD133+ cells is feasible but was associated with increased incidence of coronary events. Nevertheless, it seems to be associated with improved left ventricular performance paralleled with increased myocardial perfusion and viability.

AC133 Antigen↗

Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging.

BACKGROUND AND AIM: Left and right ventricular ejection fractions (LVEF and RVEF) and end-diastolic and end-systolic volumes (LVEDV, RVEDV, LVESV and RVESV) can be calculated from tomographic radionuclide ventriculography (TRV). The aim of this study was to validate and compare these parameters obtained using four different TRV software programs (QBS, QUBE, 4D-MSPECT and BP-SPECT). METHODS: LVEF obtained from planar radionuclide ventriculography (PRV) was compared with LVEF obtained from TRV using the four different software programs in 166 patients. Furthermore, ventricular volumes obtained using TRV (QBS, QUBE and 4D-MSPECT) were compared with those obtained using BP-SPECT, the latter being the only method with the validation of ventricular volumes in the literature. RESULTS: The correlation of LVEF between PRV and TRV was good for all methods: 0.81 for QBS, 0.79 for QUBE, 0.71 for 4D-MSPECT and 0.79 for BP-SPECT. The mean differences+/-standard deviation (SD) were 3.16+/-9.88, 10.72+/-10.92, 3.43+/-11.79 and 2.91+/-10.39, respectively. The correlation of RVEF between BP-SPECT and QUBE and QBS was poor: 0.33 and 0.38, respectively. LV volumes calculated using QBS, QUBE and 4D-MSPECT correlated well with those obtained using BP-SPECT (0.98, 0.90 and 0.98, respectively), with mean differences+/-SD of 7.31+/-42.94, -22.09+/-36.07 and -40.55+/-39.36, respectively. RV volumes showed poorer correlation between QBS and BP-SPECT and between QUBE and BP-SPECT (0.82 and 0.57, respectively). CONCLUSION: LVEF calculated using TRV correlates well with that calculated using PRV, but is not interchangeable with the value obtained using PRV. Volume calculations (for left and right ventricle) and RVEF require further validation before they can be used in clinical practice.

Algorithms↗

Impact of waiting on the perception of service quality in nuclear medicine.

BACKGROUND: This is the first study examining the link between waiting and various dimensions of perceived service quality in nuclear medicine. METHODS: We tested the impact of selected waiting experience variables on the evaluation of service quality, measured using the Servqual tool, of 406 patients in nuclear medicine, with objective and subjective waiting times as co-variates. The sequence of events in service delivery in nuclear medicine (waiting time before injection, waiting time before scanning and total waiting time) is taken into account. RESULTS: Patients underestimated the waiting time before injection and the total waiting time, while overestimated the waiting time before scanning. Our results show that the total subjective waiting time has more impact on the reliability dimension (R2(adj)=0.148) than on the other service quality dimensions of Servqual. Providing information about the reasons for delay had a significant main effect on the perception of reliability (F=9.64, P=0.02). CONCLUSIONS: The study stresses the importance of explaining the causes for delay to increase patients' perceptions of reliability of the nuclear medicine department and contains several findings that should assist service managers to formulate more effective waiting perception strategies.

Adolescent↗

Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom.

UNLABELLED: Various automatic algorithms are now being developed to calculate left ventricular (LV) and right ventricular (RV) ejection fraction from tomographic radionuclide ventriculography. We tested the performance of 4 of these algorithms in estimating LV and RV volume and ejection fraction using a dynamic 4-chamber cardiac phantom. METHODS: We developed a realistic physical, dynamic 4-chamber cardiac phantom and acquired 25 tomographic radionuclide ventriculography images within a wide range of end-diastolic volumes, end-systolic volumes, and stroke volumes. We assessed the ability of 4 algorithms (QBS, QUBE, 4D-MSPECT, and BP-SPECT) to calculate LV and RV volume and ejection fraction. RESULTS: For the left ventricle, the correlations between reference and estimated volumes (0.93, 0.93, 0.96, and 0.93 for QBS, QUBE, 4D-MSPECT, and BP-SPECT, respectively; all with P < 0.001) and ejection fractions (0.90, 0.93, 0.88, and 0.92, respectively; all with P < 0.001) were good, although all algorithms underestimated the volumes (mean difference [+/-2 SDs] from Bland-Altman analysis: -39.83 +/- 43.12 mL, -33.39 +/- 38.12 mL, -33.29 +/- 40.70 mL, and -16.61 +/- 39.64 mL, respectively). The underestimation by QBS, QUBE, and 4D-MSPECT was greater for higher volumes. QBS, QUBE, and BP-SPECT could also be tested for the right ventricle. Correlations were good for the volumes (0.93, 0.95, and 0.97 for QBS, QUBE, and BP-SPECT, respectively; all with P < 0.001). In terms of absolute volume estimation, the mean differences (+/-2 SDs) from Bland-Altman analysis were -41.28 +/- 43.66 mL, 11.13 +/- 49.26 mL, and -13.11 +/- 28.20 mL, respectively. Calculation of RV ejection fraction correlated well with true values (0.84, 0.92, and 0.94, respectively; all with P < 0.001), although an overestimation was seen for higher ejection fractions. CONCLUSION: Calculation of LV and RV ejection fraction based on tomographic radionuclide ventriculography was accurate for all tested algorithms. All algorithms underestimated LV volume; estimation of RV volume seemed more difficult, with different results for each algorithm. The more irregular shape and inclusion of a relatively hypokinetic RV outflow tract in the right ventricle seemed to cause the greater difficulty with delineation of the right ventricle, compared with the left ventricle.

Algorithms↗

Accuracy of commercially available processing algorithms for planar radionuclide ventriculography using data for a dynamic left ventricular phantom.

BACKGROUND: Automatic and semi-automatic algorithms to calculate ejection fraction (EF) from planar radionuclide ventriculography (PRV) have been used for many years in nuclear medicine. Validation of these algorithms is scarce and often performed on outdated versions of the software. Nevertheless, clinical trials where PRV is being used as the 'gold standard' for EF are numerous. Because of the importance attributed to the EF calculated by these programs, the accuracy of the resulting EF was assessed with a dynamic left ventricular physical phantom. METHODS: A dynamic left ventricular phantom was used to simulate 21 combinations of various ejection fractions (7-66%) and end diastolic volumes (27-290 ml). For each combination, a planar radionuclide ventriculograph was acquired, converted to an interfile format and transferred into processing stations with 10 different contemporaneously available commercial algorithms. The gold standard was the 'real' EF of the phantom, derived from the exact volume of the ventricle in end diastolic and end systolic position. Correlation and Bland-Altman analysis was performed between the real EF and the calculated EF. RESULTS: The correlation for all data was excellent (r=0.98), the mean difference was very acceptable (0.98%). Nevertheless, Bland-Altman analysis showed a significant trend in the difference between real and calculated EF, with a growing underestimation for higher ranges of EF, due to an overestimation of background in larger volumes compared to smaller ones. CONCLUSION: The determination of EF from PRV, calculated with commercially available algorithms, correlates closely to the real EF of a dynamic left ventricular phantom. This phantom can be used in the development and validation of algorithms for PRV studies, in software audits and in quality assurance procedures.

Algorithms↗

Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom.

UNLABELLED: We have developed a biventricular dynamic physical cardiac phantom to test gated blood-pool (GBP) SPECT image-processing algorithms. Such phantoms provide absolute values against which to assess accuracy of both right and left computed ventricular volume and ejection fraction (EF) measurements. METHODS: Two silicon-rubber chambers driven by 2 piston pumps simulated crescent-shaped right ventricles wrapped partway around ellopsoid left ventricles. Twenty experiments were performed at Ghent University, for which right and left ventricular true volume and EF ranges were 65-275 mL and 55-165 mL and 7%-49% and 12%-69%, respectively. Resulting 64 x 64 simulated GBP SPECT images acquired at 16 frames per R-R interval were sent to Columbia University, where 2 observers analyzed images independently of each other, without knowledge of true values. Algorithms automatically segmented right ventricular activity volumetrically from left ventricular activity. Automated valve planes, midventricular planes, and segmentation regions were presented to observers, who accepted these choices or modified them as necessary. One observer repeated measurements >1 mo later without reference to previous determinations. RESULTS: Linear correlation coefficients (r) of the mean of the 3 GBP SPECT observations versus true values for right and left ventricles were 0.80 and 0.94 for EF and 0.94 and 0.95 for volumes, respectively. Correlations for right and left ventricles were 0.97 and 0.97 for EF and 0.96 and 0.89 for volumes, respectively, for interobserver agreement and 0.97 and 0.98 for EF and 0.96 and 0.90 for volumes, respectively, for intraobserver agreement. No trends were detected, though volumes and right ventricular EFs were significantly higher than true values. CONCLUSION: Overall, GBP SPECT measurements correlated strongly with true values. The phantom evaluated shows considerable promise for helping to guide algorithm developments for improved GBP SPECT accuracy.

Computer Simulation↗

The exceptional brain of Maurice Ravel.

This historical review describes the brain disease which afflicted the great impressionist-classicist composer Maurice Ravel (1875-1937). The usual interpretation of the symptoms Ravel exhibited during his disease is primary progressive aphasia / Pick's disease. Some authors see this as the cause for his lost musical creativity during the last years of his life. By contrast, in our review it is presented why a car accident in 1932, with the probable consequence of a mild to moderate traumatic brain injury, could be the key event in his life, triggering the loss of his ability to compose. In addition, the influence of Ravel's disease on his musical style is evaluated. Although some authors see a link, we try to explain why there is no clear evidence for this.

Brain Injuries↗

Day-to-day variability of global left ventricular functional and perfusional measurements by quantitative gated SPECT using Tc-99m tetrofosmin in patients with heart failure due to coronary artery disease.

BACKGROUND: Although myocardial gated single photon emission computed tomography (SPECT) is routinely used for functional measurements in patients with coronary artery disease (CAD) and heart failure, day-to-day variability of left ventricular ejection fraction (LVEF), left ventricular (LV) volumes, and global perfusion scoring has not yet been investigated. METHODS AND RESULTS: In 20 consecutive patients with CAD and an LVEF lower than 40% who routinely underwent a resting tetrofosmin gated SPECT study, we performed an additional gated SPECT study at rest 1 to 5 days later under the same circumstances. LV volumes and LVEF were calculated from the gated SPECT data by commercially available software (QGS). Myocardial perfusion was scored visually by use of a 20-segment, 5-point scoring method. For global LV function and perfusion, agreement between data was investigated by use of Bland-Altman plotting. The 95% limits of agreement found by Bland-Altman analysis were -0.9% +/- 6.0% for LVEF, 3 +/- 20 mL for LV end-diastolic volume, and 4 +/- 20 mL for LV end-systolic volume. CONCLUSION: In CAD patients with an LVEF lower than 40%, day-to-day variability of measurements of global myocardial function and perfusion is quite similar to interobserver and intraobserver variability. Day-to-day variability of global LV functional parameters obtained by gated cardiac SPECT is fairly small, which indicates that myocardial gated SPECT can be used in daily clinical practice to determine changes in global LV function and perfusion over time in patients with diminished LV function.

Aged↗

Model dependence of gated blood pool SPECT ventricular function measurements.

BACKGROUND: Calculation differences between various gated blood pool (GBP) single photon emission computed tomography (SPECT) (GBPS) algorithms may arise as a result of different modeling assumptions. Little information has been available thus far regarding differences for right ventricular (RV) function calculations, for which GBPS may be uniquely well suited. METHODS AND RESULTS: Measurements of QBS (Cedars-Sinai Medical Center, Los Angeles, Calif) and BP-SPECT (Columbia University, New York, NY) algorithms were evaluated. QBS and BP-SPECT left ventricular (LV) ejection fraction (EF) correlated strongly with conventional planar-GBP LVEF for 422 patients (r = 0.81 vs r = 0.83). QBS correlated significantly more strongly with BP-SPECT for LVEF than for RVEF (r = 0.80 vs r = 0.41). Both algorithms demonstrated significant gender differences for 31 normal subjects. BP-SPECT normal LVEF (67% +/- 9%) was significantly closer to values in the magnetic resonance imaging (MRI) literature (68% +/- 5%) than QBS (58% +/- 9%), but both algorithms underestimated normal RVEF (52% +/- 7% and 50% +/- 9%) compared with the MRI literature (64% +/- 9%). For 21 patients, QBS correlated similarly to MRI as BP-SPECT for LVEF (r = 0.80 vs r = 0.85) but RVEF correlation was significantly weaker (r = 0.47 vs r = 0.81). For 16 dynamic phantom simulations, QBS LVEF correlated similarly to BP-SPECT (r = 0.81 vs r = 0.91) but QBS RVEF correlation was significantly weaker (r = 0.62 vs r = 0.82). Volumes were lower by QBS than BP-SPECT for all data types. CONCLUSIONS: Both algorithms produced LV parameters that correlated strongly with all forms of image data, but all QBS RV relationships were significantly different from BP-SPECT RV relationships. Differences between the two algorithms were attributed to differences in their underlying ventricular modeling assumptions.

Algorithms↗

Incremental prognostic value of combined perfusion and function assessment during myocardial gated SPECT in patients aged 75 years or older.

BACKGROUND: Perfusion and functional data obtained during gated single photon emission computed tomography (SPECT) have proven prognostic value in the middle-aged patient population. The aim of this study was to investigate whether perfusion and functional cardiac gated SPECT data have prognostic value in patients aged 75 years or older. METHODS AND RESULTS: We studied clinical and gated SPECT predictors of cardiac and all-cause death in 294 patients aged 75 years or older with known or suspected coronary artery disease who were referred for tetrofosmin cardiac gated SPECT imaging. Summed perfusion scores were calculated in a 17-segment model by use of commercially available software (4D-MSPECT). Left ventricular functional data were calculated by use of QGS gated SPECT software. The median age of the study population was 78 years (range, 75-91 years). There were 160 men (54%) and 134 women (46%). During a median follow-up of 25.9 months (range, 1.8-36 months), 47 patients (16%) died (27 cardiac deaths). In a multivariate Cox proportional hazards regression analysis, the summed rest score (chi2 gain = 8.0, P = .009), transient ischemic dilatation index (chi2 gain = 6.3, P = .012), and resting left ventricular ejection fraction (chi2 gain = 7.0, P = .030) were independent predictors of all-cause death. The summed rest score (chi2 gain = 8.2, P = .004) and resting end-systolic volume (chi2 gain = 13.7, P = .005) were independent predictors of cardiac death. CONCLUSIONS: This study showed that gated SPECT left ventricular functional data assessed during myocardial gated SPECT provide independent and incremental information above clinical and perfusion SPECT data for the prediction of cardiac and all-cause death in patients aged 75 years or older referred for myocardial SPECT imaging.

Aged↗