Reproducibility of postprocessing of quantitative CT perfusion maps.

OBJECTIVE: The purpose of this study was to assess interobserver and intraobserver variability in evaluation of the reproducibility of quantitative data obtained in semiautomated postprocessing of CT perfusion data sets by observers of different levels of skill and experience and in fully automated postprocessing. MATERIALS AND METHODS: Twenty CT perfusion data sets were postprocessed by a neuroradiologist using an automated postprocessing program and by five observers (neuroradiology attending, neurology attending, radiology resident, senior and junior CT technologists) who received a brief training session in use of software for semiautomated postprocessing. For assessment of intraobserver variability, each observer repeated postprocessing of 10 CT perfusion data sets. Standard regions of interest were placed on identical locations for each observer's cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps of three brain regions: an ischemia-infarct region, normal cortical gray matter, and white matter. RESULTS: The variability in mean quantitative values of CBF, CBV, and MTT was 2.5-9.5% among all observers. Greater variability (20.4%) was introduced with the automated program. High correlation was found among all possible pairings of observers (r = 0.87-0.99). Low correlation was observed between automated postprocessing and postprocessing by all observers. Intraobserver variability in quantitative CT perfusion data ranged from 0.29% to 10.8%. High intraobserver correlation (r = 0.91-0.99) was found for the observers. CONCLUSION: Quantitative CBF, CBV, and MTT data obtained from postprocessing of CT perfusion data sets are reproducible among observers with varying levels of skill and experience. Observer interaction with the software is an important component for correct identification of user-defined parameters. Establishing a uniform and standard postprocessing technique is essential for maintaining good reproducibility.

Algorithms↗

Monitoring the effects of BCNU chemotherapy Wafers (Gliadel) in glioblastoma multiforme with proton magnetic resonance spectroscopic imaging at 3.0 Tesla.

Carmustine wafers (Gliadel Wafer) are implanted at resection in some patients with high-grade gliomas. Studies suggest that proton magnetic resonance spectroscopic imaging ((1)H MRSI) demonstrates early changes predictive of future failure or response to systemic chemotherapy. This study explores (1)H MRSI as a means to assess peri-tumoral tissue response post-resection and Gliadel((R)) implantation in patients with high-grade gliomas. Pilot (1)H MRSI data are presented that demonstrate noninvasive, serial monitoring of metabolic changes at the tumor site following Gliadel implantation. Three patients with newly diagnosed glioblastoma multiforme (GBM) underwent MRI and (1)H MRSI at 3.0 Tesla prior to resection and at 3-5 and > or =12 weeks post-operatively. Baseline MRS spectra of tumor tissue from all patients were characterized by marked increases of choline (CHO) and lactate (LAC), and a decrease of N-acetylaspartate (NAA), typical of GBM compared with normal contra-lateral brain tissue. Post-operatively, spectra were analyzed from the resection cavity and peri-tumoral regions and compared with normal tissue from the contra-lateral brain at baseline. In 2 of 3 patients, peri-tumoral NAA/CRE increased and CHO/NAA decreased compared to contra-lateral brain at 3-5 weeks compared with baseline following Gliadel therapy and surgery but prior to radiotherapy. This study indicates that (1)H MRSI has the ability to localize regions of heterogeneous response following Gliadel treatment. Although data are limited, these results suggest that metabolic indicators of outcome can be successfully monitored pre- and post-surgical resection and Gliadel implantation with (1)H MRSI. Additional study of patients receiving Gliadel Wafers using (1)H MRSI may serve to aid clinicians in assessing tumor regression and gauging efficacy of this chemotherapy treatment.

Aged↗

Vasospasm in aneurysmal subarachnoid hemorrhage: diagnosis, prevention, and management.

Cerebral vasospasm is a major cause of morbidity and mortality associated with subarachnoid hemorrhage (SAH). Advances in neuroimaging and development of newer intraparenchymal monitoring devices have improved the prediction and diagnosis of cerebral vasospasm significantly. Recent experimental and clinical trials have increased the armamentarium of preventive and treatment strategies for cerebral vasospasm. Vasospasm refractory to medical therapy usually is treated endovascularly with percutaneous transluminal balloon angioplasty (PTA) for proximal vessel vasospasm and vasodilator infusion for distal vessel vasospasm. Although vasospasm usually does not recur after PTA, recurrence is frequent after vasodilator infusion. The development of newer microballoon catheters has led to improvements in treatment of not only proximal but also distal vessel vasospasm with balloon angioplasty. This article reports on current knowledge in the diagnosis, prediction, prevention, and management of cerebral vasospasm.

Humans↗

Perfusion imaging of cerebrovascular reserve.

Cerebrovascular reserve reflects the capacity of the brain to maintain adequate blood flow in the face of decreased perfusion pressure. Perfusion imaging, combined with a physiologic or pharmacologic challenge, is a direct method of measuring cerebrovascular reserve. The authors discuss the strengths and drawbacks of each of the methods of cerebrovascular reserve assessment. They review the applications of cerebrovascular reserve testing, particularly in the assessment of stroke risk in the setting of chronic stenosis or occlusion of vessels in the head and neck.

Blood Pressure↗

Posterior reversible encephalopathy syndrome on computed tomography perfusion in a patient on "Triple H" therapy.

INTRODUCTION: This article reports a case of posterior reversible encephalopathy syndrome on compyted tomography (CT) perfusion in a patient on "Triple H" (hypertension, hypervolemia, and hemodilution) therapy following aneurysmal rupture repair. CASE REPORT: "Triple H" therapy is used in the postoperative course for treatment of vasospasm to prevent stroke and hemorrhage by maintaining cerebral perfusion pressure. DISCUSSION: A potential complication includes vasogenic edema from dysfunction of cerebral blood vessel autoregulation. CT perfusion can detect alterations in cerebral blood flow and volume caused by these hemodynamic changes.

Female↗

The effect of varying user-selected input parameters on quantitative values in CT perfusion maps.

RATIONALE AND OBJECTIVES: Deconvolution-based software can be used to calculate quantitative maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) from first-pass computed tomography perfusion (CTP) datasets. The application of this software requires the user to select multiple input variables. The purpose of this study was to investigate the degree to which both major and minor variations of these user-defined inputs would affect the final quantitative values of CBF, CBV, and MTT. MATERIALS AND METHODS: A neuroradiologist constructed CBF, CBV, and MTT maps using standard methodology with commercially available software (GE Functool Version 1.9s) from CTP datasets of three acute stroke patients. Each map was reconstructed multiple times by systematically and independently varying the following parameters: postenhancement and preenhancement cutoff values, arterial and venous region-of-interest (ROI) placement, and arterial and venous ROI size. The resulting quantitative CTP values were compared using identical ROIs placed at the infarct core. RESULTS: Major variations of either arterial ROI placement or arterial and venous ROI size had no significant effect on the mean CBF, CBV, and MTT values at the infarct core (p > .05). Even minor variations, however, in the choice of venous ROI placement or in pre- and postenhancement cutoff values significantly altered the quantitative values for each of the CTP maps, by as much as threefold. CONCLUSION: Even minor variations of user-defined inputs can significantly influence the quantitative, deconvolution-based CTP map values of acute stroke patients. Although quantitation was robust to the choice of arterial ROI placement and arterial or venous ROI size, it was strongly dependent on the choice of venous ROI location and pre- and postenhancement cut-off values. Awareness of these results by clinicians may be important in the creation of quantitatively accurate CTP maps.

Adult↗

Relationship of petrous temporal bone pneumatization to the eustachian tube lumen.

OBJECTIVES/HYPOTHESIS: Objectives were to determine the incidence of petrous apex pneumatization and to define the relationship between a pneumatized petrous temporal bone and the eustachian tube lumen. STUDY DESIGN: Retrospective study with institutional review board approval including only adult patients. METHODS: One hundred head computed tomography (ct) scans and 204 petrous temporal bone CT scans performed at a tertiary teaching hospital were reviewed. The two senior authors (s.h.s., p.c.s.) independently reviewed the petrous temporal bone CT scans for grade of pneumatization. Pneumatized CT scans were then reviewed for the presence of a direct communication with the eustachian tube lumen. Significance was determined using the chi test and Pearson correlation of ranks. RESULTS: The incidence of peritubal cells opening into the eustachian tube anterior to the tympanic orifice was 92%. CONCLUSION: The direct communication of peritubal cells with the bony eustachian tube may play a role in the development of persistent cerebrospinal fluid rhinorrhea after cerebellopontine angle surgery.

Adult↗

Role of CT angiography in guiding management decisions of newly diagnosed and residual arteriovenous malformations.

OBJECTIVE: Our aim was to show the usefulness of CT angiography for treatment planning of intracranial arteriovenous malformations. CONCLUSION: The conventional gold standard for analysis of these cerebrovascular lesions is digital subtraction angiography. Although this technique remains the gold standard, we have determined that CT angiography is a useful adjunct for characterization and stereotactic localization before surgical resection or radiosugical treatment of arteriovenous malformations. This multitechnique approach can lead to more accurate nidus localization and therefore more effective management strategies.

Adolescent↗

Safety and feasibility of using a central venous catheter for rapid contrast injection rates.

OBJECTIVE: Our aim was to determine the safety and feasibility of using a central venous catheter for rapid contrast injections during CT. MATERIALS AND METHODS: An in vitro experiment was performed using a 7-French Arrow-Howes multilumen central venous catheter. Each catheter port was tested by varying contrast agent flow rates delivered by a power injector. Contrast media specifications were kept similar to routine clinical practice. The in vivo experiment included 104 cases in which rapid contrast injections, 3.0-5.0 mL/sec, were delivered through a central venous catheter for dynamic CT examinations. Patient monitoring for early complications of contrast extravasation, cardiac arrhythmia, and allergic reactions was performed. Contrast injections were monitored for pressure limitation, automatic flow-rate adjustment, and catheter injury. Chart review was performed for delayed complications of mediastinal hematoma, infection, or catheter malfunction. RESULTS: During the in vitro experiment, all desired flow rates, 3.0-9.9 mL/sec, could be delivered through the central venous catheter with no catheter injury. No immediate or early patient or catheter complications were observed during the in vivo experiment. Follow-up evaluation revealed that 18 blood cultures and one catheter culture were positive for bacterial growth. In a subgroup of 43 patients, five contrast injections were pressure-limited by the power injector, and only one had the flow rate automatically adjusted to 3.6 mL/sec from 4.0 mL/sec. CONCLUSION: Rapid contrast injection rates, at 3.0-5.0 mL/sec, through the Arrow-Howes multilumen central venous catheter are feasible and safe in the clinical setting. However, a strict protocol should be followed to avoid possible serious complications.

Adult↗

Normal variation of vertebral artery on CT angiography and its implications for diagnosis of acquired pathology.

PURPOSE: CT angiography (CTA) is rapidly becoming a popular tool for the evaluation of cerebrovascular diseases. Noninvasive diagnosis of vertebral artery pathology using CTA relies in part on diminished vertebral artery size or eccentric position relative to the transverse foramen. However, normal variation of the vertebral artery on CT has not been systematically described. METHOD: Patients younger than 40 years who underwent CTA for reasons other than evaluation of vertebral artery disease were studied. Area measurements of the vertebral artery and the transverse foramen were performed by three radiologists. Variance component analysis was performed. RESULTS: There is marked variation in the size of the vertebral artery relative to the transverse foramen, with the vertebral artery occupying 8-85% of the foramen. In many patients, marked asymmetry in relative vertebral artery size and position was observed. This asymmetry would often vary markedly from level to level within the same patient. CONCLUSION: Vertebral artery size and position in the transverse foramina vary markedly in normal young subjects. These normal variations must be considered when evaluating vertebral artery pathology on CT angiograms.

Adult↗