Microinfusion using hollow microneedles.

PURPOSE: The aim of the study is to determine the effect of experimental parameters on microinfusion through hollow microneedles into skin to optimize drug delivery protocols and identify rate-limiting barriers to flow. METHODS: Glass microneedles were inserted to a depth of 720-1080 microm into human cadaver skin to microinfuse sulforhodamine solution at constant pressure. Flow rate was determined as a function of experimental parameters, such as microneedle insertion and retraction distance, infusion pressure, microneedle tip geometry, presence of hyaluronidase, and time. RESULTS: Single microneedles inserted into skin without retraction were able to infuse sulforhodamine solution into the skin at flow rates of 15-96 microl/h. Partial retraction of microneedles increased flow rate up to 11.6-fold. Infusion flow rate was also increased by greater insertion depth, larger infusion pressure, use of a beveled microneedle tip, and the presence of hyaluronidase such that flow rates ranging from 21 to 1130 microl/h were achieved. These effects can be explained by removing or overcoming the large flow resistance imposed by dense dermal tissue, compressed during microneedle insertion, which blocks flow from the needle tip. CONCLUSIONS: By partially retracting microneedles after insertion and other methods to overcome flow resistance of dense dermal tissue, protocols can be designed for hollow microneedles to microinfuse fluid at therapeutically relevant rates.

Drug Delivery Systems↗

Precise microinjection into skin using hollow microneedles.

Hollow needles of micron dimensions have previously been fabricated and envisioned for use with transdermal patches or infusion pumps to achieve painless delivery of drugs to the skin for local and systemic effects without the need for hypodermic needles. However, little work has been carried out to identify methods to effectively use hollow microneedles for drug delivery. To address this need, we inserted hollow, glass microneedles into hairless rat skin in vivo and human cadaver skin in vitro and then imaged infusion of dye molecules, insulin, polymer microparticles, and cells into the skin by brightfield and fluorescence microscopy. The depth of needle penetration into skin was controlled by inserting needles with a rotary drilling device, which enabled localized injection within the epidermis or dermis with +/-60 microm resolution. Although small quantities of fluid could be injected after needle insertion into skin, partial retraction of the needle by withdrawing back 100-300 microm or vibrating the microneedle array dramatically increased infusion flow rate. We conclude that hollow microneedles can be used for precise microinjection into skin, especially when a single needle is inserted by rotary drilling and then retracted part way before infusion or a microneedle array is inserted by mechanical vibration.

Cell Transplantation↗

Assessment of trueness of a glucose monitor using interstitial fluid and whole blood as specimen matrix.

BACKGROUND: Interstitial fluid (ISF) is a specimen of increasing interest for glucose measurements because it can be obtained in a minimally invasive manner. Our previous study showed that sufficient ISF can be obtained using microneedles to measure glucose with a conventional electrochemical glucose monitor. The aim of this study was to assess the trueness of this glucose monitor using split-sample comparison with whole blood. We used ISF as specimen and our gas chromatography/mass spectrometry (GC/MS) method as reference. METHODS: We obtained 50 ISF samples and 40 whole blood samples from hairless Sprague- Dawley rats and analyzed for glucose by both methods. RESULTS: For whole blood, a non-significant bias of 5.7% (+/-2 SD: -54.9% to 66.3%) was determined. ISF glucose measurements showed a significant constant bias of 29.5% (+/-2 SD: -85.0% to 144%), which seems to be caused in part by the lack of red blood cells in ISF. The correlation coefficients were 0.782 and 0.679 for whole blood and ISF, respectively. CONCLUSIONS: The assessed electrochemical glucose monitor shows a close agreement with our GC/MS reference method for whole blood, for which this monitor was optimized. When glucose measurements are performed with ISF as matrix, the observed bias needs to be taken into consideration. Further studies are necessary to elucidate the reasons for the wide dispersion of data for ISF.

Animals↗

Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles.

BACKGROUND: Compliance with glucose monitoring by patients with diabetes is poor because of the pain and inconvenience of conventional blood collection using lancets. To improve compliance, and thereby reduce morbidity and mortality associated with poor glucose control, this study sought to develop and test minimally invasive microneedles to extract dermal interstitial fluid (ISF) for glucose monitoring. METHODS: We used a thermal puller to fabricate individual or multi-needle arrays of glass microneedles with tip radii of 15-40 microm to penetrate 700-1,500 microm deep into the skin of anesthetized hairless rats or conscious, normal, adult, human subjects. After applying a vacuum of 200-500 mm Hg for 2-10 min, we extracted ISF and measured glucose concentration. These measurements were compared with glucose levels in blood collected from the tail vein of rats or finger stick on humans. RESULTS: Using this procedure, 1-10 microL of ISF was extracted out of holes punctured in the skin using microneedles. Human subjects generally reported the procedure as painless. ISF glucose concentration correlated well with blood levels based on 140 measurements on 15 rats and six measurements on six human subjects, where 95% of rat data and 100% of human data fell within the clinically acceptable A + B region in Clarke Error Grid analysis. A linear calibration factor was needed to correlate ISF and blood glucose concentrations using our standard procedure. Modifying the procedure to prevent ISF evaporation during extraction provided a one-to-one correlation that eliminated the need for calibration. ISF glucose measurements tracked rapidly changing blood glucose levels following insulin injection with a time lag of less than 20 min. CONCLUSIONS: These results suggest that microneedle devices can be used to extract ISF for painless glucose monitoring.

Animals↗

Fractal branching pattern of the monopodial canine airway.

Unlike the human lung, monopodial canine airway branching follows an irregular dichotomized pattern with fractal features. We studied three canine airway molds and found a self-similarity feature from macro- to microscopic scales, which formed a fractal set up to seven scales in the airways. At each fractal scale, lateral branches evenly lined up along an approximately straight main trunk to form three to four two-dimensional structures, and each lateral branch was the monopodial main trunk of the next fractal scale. We defined this pattern as the fractal main lateral-branching pattern, which exhibited similar structures from macro- to microscopic scales, including lobes, sublobes, sub-sublobes, etc. We speculate that it, rather than a mother-daughter pattern, could better describe the actual asymmetrical architecture of the monopodial canine airway.

Animals↗

Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: fabrication methods and transport studies.

Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 microm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo, including microinjection of insulin to reduce blood glucose levels in diabetic rats.

Administration, Cutaneous↗