PubMed Health⌕ Search

Biomedical subjects

Piotr J Slomka

Publications and source records attributed to Piotr J Slomka.

17 recordsLinked to original sources

Left ventricular shape index assessed by gated stress myocardial perfusion SPECT: initial description of a new variable.

BACKGROUND: Ventricular remodeling is predictive of congestive heart failure (CHF). We aimed to automatically quantify a new myocardial shape variable on gated myocardial perfusion single photon emission computed tomography (SPECT) (MPS) and to evaluate the association of this new SPECT parameter with the risk of hospitalization for CHF. METHODS AND RESULTS: A computer algorithm was used to measure the 3-dimensional (3D) left ventricular (LV) shape index (LVSI), derived as the ratio of maximum 3D short- and long-axis LV dimensions, for end systole and end diastole. LVSI normal limits were obtained from stress technetium 99m sestamibi MPS images of 186 patients (60% of whom were men) (control subjects) with a low likelihood of CAD (< 5%). These limits were tested in a consecutive series of 93 inpatients (85% of whom were men) having MPS less than 1 week after hospitalization, of whom 25 were hospitalized for CHF exacerbation. Variables associated with CHF hospitalization were tested by receiver operating characteristic curve and multivariate logistic regression analyses. LVSI repeatability was assessed in 52 patients with ischemic cardiomyopathy who had sequential stress MPS within 60 days after the initial MPS without clinical events in the interval between MPS studies. Control subjects had lower end-systolic and end-diastolic LVSIs compared with patients with CHF and those without CHF (P < .001). Receiver operating characteristic curve areas for the prediction of hospitalization as a result of CHF were similar for LV ejection fraction and end-systolic LVSI. End-systolic and end-diastolic LVSIs were independent predictors of CHF hospitalization by multivariate analysis; however, end-systolic LVSI had the greatest added value among all tested variables. Repeatability was excellent for both end-systolic LVSI (R2 = 0.85, P < .0001) and end-diastolic LVSI (R2 = 0.82, P < .001). CONCLUSION: LVSI is a promising new 3D variable derived automatically from gated MPS providing highly repeatable ventricular shape assessment. Preliminary findings suggest that LVSI might have clinical implications in patients with CHF.

Adult↗

Simplified normal limits and automated quantitative assessment for attenuation-corrected myocardial perfusion SPECT.

BACKGROUND: We aimed to compare normal limits and the detection of coronary artery disease (CAD) with attenuation-corrected (AC) and non-attenuation-corrected (NC) myocardial perfusion single photon emission computed tomography (MPS) by use of a recently improved automated quantification technique. METHODS AND RESULTS: We acquired 415 rest/stress technetium 99m MPS studies on a Vertex dual-detector camera with a gadolinium 153 line source (Vantage Pro). Gender-specific NC, AC, and gender-combined AC normal limits were created from rest/stress images of 50 women and 50 men with a low likelihood of CAD (< 5%) and a median body mass index (BMI) of 30 kg/m2 in each gender group. BMI-specific normal limits (< 30 kg/m2 and > or = 30 kg/m2) were also compared. Total perfusion deficit and 17-segment summed scores in 174 patients were compared with angiography, and normalcy rates were established from 141 studies of low-likelihood patients. There were no differences between low-BMI and high-BMI normal limits for AC or NC studies. Male and female normal limits differed in 12 of 17 segments for NC stress studies and in 3 of 17 segments for AC stress studies (P < .01). The sensitivity, specificity, and normalcy rates for stenoses with 70% narrowing or greater were 89%, 73%, and 91%, respectively, for NC studies and 87%, 80%, and 95%, respectively, for AC studies (P = not significant). CONCLUSION: Automated detection of CAD by AC and NC MPS demonstrated similar sensitivity, specificity, and normalcy rates. Some gender differences were noted for AC normal limits.

Aged↗

Rapid assessment of left ventricular segmental wall motion, ejection fraction, and volumes with single breath-hold, multi-slice TrueFISP MR imaging.

BACKGROUND AND OBJECTIVE: To reduce imaging time and complexity, we sought to determine whether single breath-hold, multi-slice TrueFISP (SB-MST) magnetic resonance imaging (MRI) method is comparable to standard multi-breath-hold, multi-slice TrueFISP (MB-MST) for assessment of left ventricular (LV) wall motion abnormality (WMA), volumes, and ejection fraction (EF). METHODS AND RESULTS: We studied 62 patients having cardiac MRI at 1.5-Tesla. After acquiring standard MB-MST (one slice per breath-hold), SB-MST was performed, acquiring 3 short- and 2 long-axis views over only 20 heartbeats. Using both techniques, wall motion was scored using a 6-point, 17-segment LV model for all scans (62 patients x 2 techniques/patient = 124 scans) on two separate occasions. Separately, EF and ventricular volumes were evaluated using both MB-MST and SB-MST. For all analyses, MB-MST was considered the standard against which SB-MST was compared. Twenty-six of 62 patients exhibited at least one segmental WMA by MB-MST. Exact agreement for wall motion was found in 965/1054 segments (92%, kappa = 0.74, p < 0.001), and agreement was within 1 score point in 1010/1054 segments (96%). Considering a score >1 abnormal, exact agreement for presence of WMA was found in 131/193 segments (68%) abnormal by MB-MST and for absence of WMA in 838/861 segments (97%) normal by MB-MST. Agreement within 1 score point occurred in 167/193 abnormal (87%) and in 843/861 normal segments (98%). There were no significant differences in agreement between first and second read of the data. Variability of SB-MST on read one versus read two was small (5%, 996/1054 segments read identically, p = ns) and statistically identical to variability of MB-MST on read one versus read two (4%, 1007/1054 segments read identically, p = ns). For end-diastolic volumes, end-systolic volumes, and EF using SB-MST compared to MB-MST, mean differences were 9 +/- 15 ml, 6 +/- 12 ml, and 2 +/- 5%, and correlations were r = 0.97, 0.98 and 0.95, respectively. CONCLUSION: SB-MST accurately assesses wall motion, volumes and EF. This approach may serve as a screening exam for assessment of WMA and, under select circumstances, may substitute for standard multi-breath-hold method in situations requiring rapid accurate assessments of LV function.

Aged↗

Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease.

UNLABELLED: Acquisition in the prone position has been demonstrated to improve the specificity of visually analyzed myocardial perfusion SPECT (MPS) for detecting coronary artery disease (CAD). However, the diagnostic value of prone imaging alone or combined acquisition has not been previously described using quantitative analysis. METHODS: A total of 649 patients referred for MPS comprised the study population. Separate supine and prone normal limits were derived from 40 males and 40 females with a low likelihood (LLk) of CAD using a 3 average-deviation cutoff for all pixels on the polar map. These limits were applied to the test population of 369 consecutive patients (65% males; age, 65 +/- 13 y; 49% exercise stress) without known CAD who had diagnostic coronary angiography within 3 mo of MPS. Total perfusion deficit (TPD), defined as a product of defect extent and severity scores, was obtained for supine (S-TPD), prone (P-TPD), and combined supine-prone datasets (C-TPD). The angiographic group was randomly divided into 2 groups for deriving and validating optimal diagnostic cutoffs. Normalcy rates were validated in 2 additional groups of consecutive LLk patients: unselected patients (n = 100) and patients with body mass index >30 (n = 100). RESULTS: C-TPD had a larger area under the receiver-operating-characteristic (ROC) curve than S-TPD or P-TPD for identification of stenosis >or=70% (0.86, 0.88, and 0.90 for S-TPD, P-TPD, and C-TPD, respectively; P < 0.05). In the validation group, sensitivity for P-TPD was lower than for S- or C-TPD (P < 0.05). C-TPD yielded higher specificity than S-TPD and a trend toward higher specificity than P-TPD (65%, 83%, and 86% for S-, P-, and C-TPD, respectively, P < 0.001; vs. S-TPD and P = 0.06 vs. P-TPD). Normalcy rates for C-TPD were higher than for S-TPD in obese LLk patients (78% vs. 95%, P < 0.001). CONCLUSION: Combined supine-prone quantification significantly improves the area under the ROC curve and specificity of MPS in the identification of obstructive CAD compared with quantification of supine MPS alone.

Coronary Artery Disease↗

Automatic detection and size quantification of infarcts by myocardial perfusion SPECT: clinical validation by delayed-enhancement MRI.

UNLABELLED: We aimed to validate the accuracy of a new automated myocardial perfusion SPECT quantification based on normal limits for detection and sizing of infarcts, using delayed-enhancement MRI (DE-MRI) as a gold standard. METHODS: Eighty-two immediate (201)Tl rest scans and 26 (201)Tl delayed redistribution scans were compared with resting DE-MRI scans acquired within 24 h of SPECT acquisition. The immediate (201)Tl scans were considered for validation of infarct detection and the delayed (201)Tl scans were considered for infarct sizing. A simplified quantification scheme was used in which defect extent (EXT) and total perfusion deficit (TPD) parameters were derived automatically from SPECT images by comparison with sex-matched normal limits and applying a 3.0 average deviation criterion. The total extent of hyperenhancement expressed as the percentage of the left ventricle was derived from DE-MRI images by visual definition of myocardial contours and defects. DE-MRI and SPECT images were fused in 3 dimensions for visual comparison. Phantom data were also quantified using the same EXT and TPD measures for defects ranging from 5% to 70% of the myocardium. RESULTS: The area under the receiver-operator-characteristic curve for the detection of infarct on immediate rest scans was 0.91 +/- 0.03 for EXT and 0.90 +/- 0.03 for TPD (P = not significant). The sensitivity and specificity for the detection of infarct by EXT on immediate (201)Tl rest scan were 87% and 91%, respectively, with the optimal defect size threshold of 4%. Six of 7 cases with DE-MRI defects < 5% were detected by SPECT. Infarct sizes obtained from DE-MRI correlated well with EXT (slope = 0.94, offset = 3.8%; r = 0.84) and TPD (slope = 0.75, offset = 4.2%; r = 0.85) obtained from delayed SPECT (201)Tl scans. Excellent correlation was observed between the SPECT quantification and the physical defect size for the phantom data. The actual size of the defect was better estimated by EXT (slope = 1.00, offset 1.33%; r = 0.99) than by TPD (slope = 0.79, offset = 1.9%; r = 0.99). CONCLUSION: Automated quantification of the EXT on myocardial perfusion SPECT images can reliably detect infarcts and measure infarct sizes.

Aged↗

Assessment of diastolic function using 16-frame 99mTc-sestamibi gated myocardial perfusion SPECT: normal values.

UNLABELLED: The purposes of this study were (a) to assess the feasibility of diastolic function (DFx) evaluation using standard 16-frame postexercise gated (99m)Tc-sestamibi myocardial perfusion SPECT (MPS), (b) to determine the relationship of the 2 common DFx parameters, peak filling rate (PFR) and time to peak filling (TTPF), to clinical and systolic function (SFx) variables in patients with normal myocardial perfusion and SFx, and (c) to derive and validate normal limits. METHODS: Ninety patients (71 men; age, 30-79 y) with normal exercise gated MPS were studied. None had hypertension, diabetes, rest electrocardiogram abnormality, or known cardiac disease. All patients reached > or = 85% of maximum predicted heart rate (HR). The population was randomized into derivation (n = 50) and validation (n = 40) groups. Univariable and multivariable approaches were deployed to assess the influence of clinical and functional variables on DFx parameters. RESULTS: PFR and TTPF were assessed in all patients. Mean values of PFR and TTPF in the whole study population were 2.62 +/- 0.46 end-diastolic volumes per second (EDV/s) and 164.6 +/- 21.7 ms, respectively. By applying a 2-SD cutoff to the mean values in the derivation group, the threshold for abnormal PFR and the threshold for abnormal TTPF were < 1.71 EDV/s and > 216.7 ms, respectively. The normalcy rates in the validation group for PFR and TTPF were both 100%. The PFR showed weak but significant correlations with age, EDV, end-systolic volume, left ventricular ejection fraction (LVEF), and poststress HR. However, TTPF did not correlate with these parameters. Final normal thresholds determined from the combined populations were PFR = 1.70 EDV/s and TTPF = 208 ms. Multivariable analysis showed that age, sex, LVEF, and HR are strong predictors for PFR, whereas TTPF was not influenced by any clinical or SFx variable. CONCLUSION: With a new algorithm in QGS, assessment of LV DFx is feasible using 16-frame gated MPS even without bad-beat rejection, resulting in normal limits similar to those reported with gated blood-pool studies. However, due to the dependency of PFR on SFx parameters, sex, HR, and age, TTPF appears to be a stable and more useful parameter with this approach. The clinical usefulness of these findings requires further study.

Adult↗

Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging.

PURPOSE: To develop an automatic registration method for electrocardiogram-gated myocardial perfusion single-photon emission computed tomography (SPECT) and cardiac cine-magnetic resonance imaging (MRI). MATERIALS AND METHODS: Paired myocardial perfusion SPECT (MPS) and MRI from 20 patients were considered. MR images were presegmented by heart localization based on detection of cardiac motion and optimal thresholding. A registration algorithm based on mutual information was subsequently applied to all time frames or a selected subset from both modalities. RESULTS: A preprocessing step significantly improved the accuracy of the registration when compared to automatic registration performed without preprocessing. Errors in translation parameters (T(x), T(y), T(z)) averaged (1.0 +/- 1.5, 1.1 +/- 1.3, 0.9 +/- 0.9) pixels with MRI segmentation and (4.6 +/- 3.2, 3.4 +/- 2.6, 3.0 +/- 3.4) pixels without MRI segmentation. Errors in rotation parameters (R(x), R(y), R(z)) averaged (5.4 +/- 2.9, 3.4 +/- 2.7, 4.5 +/- 3.6) degrees with MRI segmentation and (9.3 +/- 6.1, 4.8 +/- 4.3, 14.6 +/- 12.6) degrees without MRI segmentation. Error was calculated as the absolute difference between the expert manual and the automatic registration transformation. CONCLUSION: Automatic registration of gated MPS and cine MRI is possible with the use of a mutual information-based technique when MR images are presegmented. Cardiac motion can be used to isolate the left ventricle (LV) on the MR images automatically, and subsequently the segmented MR images can be coregistered with gated MPS.

Algorithms↗

Acceleration of 3D, nonlinear warping using standard video graphics hardware: implementation and initial validation.

Thin Plate Spline (TPS) transformations are used in many medical imaging algorithms, but are time-prohibitive for iterative or interactive use. We have utilized current generation consumer 3D graphics cards to accelerate the application of the TPS nonlinear transformation by combining hardware accelerated 3D textures, vertex shaders and trilinear interpolation. Our hardware accelerated algorithm warped a 512x512x173 Computed Tomography (CT) dataset in 2.3 s, and the same study, scaled to 256x256x173, in 0.5 s, using a set of 92 landmarks. An accelerated software implementation of the TPS transformation warped the 512x512x173 study in 32.9 s and the 256x256x173 study in 9.5 s. Subtracted images were used for qualitative analysis of the warp and the Mutual Information (MI) and Sum of Absolute Difference (SAD) similarity metrics were used to quantitatively compare the output of the hardware accelerated algorithm to that of the software algorithm. The hardware accelerated algorithm provided a 7-65 times performance increase when compared to the software algorithm, and produced output of comparable quality (MI > 300 and SAD < 1.75%).

Algorithms↗

Software approach to merging molecular with anatomic information.

Software image registration is a powerful and versatile tool that allows the fusion of molecular and anatomic information. Image registration can be applied to compare anatomic information with function, localize organs and lesions, and plan radiation therapy, biopsy, or surgery. Automatic volume-based image registration techniques have been devised for both linear and nonlinear image alignment. Challenges remain in the validation of the accuracy of software registration. Image registration has been applied clinically in neurology and oncology and may be particularly practical in radiotherapy applications. Potential new applications in cardiology could allow the combination of CT angiography with perfusion and viability images obtained by PET, SPECT, or MRI. Software methods allow versatility in the choice of modalities and facilitate retrospective and selective application. Fully automatic registration algorithms are needed for routine clinical applications. Connectivity, compatibility, and cooperation between various clinical departments are essential for the successful application of software-based image fusion in a hospital setting.

Algorithms↗

Automatic quantification of myocardial perfusion stress-rest change: a new measure of ischemia.

UNLABELLED: In myocardial perfusion SPECT (MPS), ischemia is typically quantified as the difference between stress and rest defect sizes obtained by separate comparisons with stress and rest normal limits. Such an approach is not optimal because images are not compared directly with each other and a complex set of stress and rest normal limits is required. METHODS: We developed a fully automatic technique to quantify stress-rest change. We applied it to 204 patients whose SPECT images were acquired using a same-day dual-isotope (99m)Tc/(201)Tl protocol and on whom coronary angiography had been performed. A 10-parameter registration of rest and stress images was performed by an iterative search of best translational, rotational, scaling, and optimal stress-rest count normalization parameters. Identical stress-rest 3-dimensional left ventricle (LV) contours were automatically derived from stress images. Integrated deficit counts (normalized rest-stress) within the LV volume were derived from registered image pairs. A global measure of ischemia (ISCH) was calculated as the ratio of the total deficit stress LV counts to the total rest LV counts. RESULTS: Registration and derivation of quantitative measures were fully automatic. The average processing time was <40 s on a 2-GHz processor. When compared for prediction of stenosis, the area under the receiver operating characteristic curve (0.88 +/- 0.03) was significantly better for ISCH than that obtained by existing quantitative approaches, which use reference databases (0.80-0.82 +/- 0.03). The normalized stress-rest change could be visualized and localized directly on raw patient images using overlay display. CONCLUSION: Automatic stress-rest MPS image registration allows a direct estimation of ischemia from SPECT that does not require comparisons with normal limits.

Adenosine↗

"Motion-frozen" display and quantification of myocardial perfusion.

UNLABELLED: Gated myocadial perfusion SPECT (MPS) incorporates functional and perfusion information of the left ventricle (LV). To improve the image quality and accuracy of gated MPS we propose to eliminate the influence of cardiac LV motion in the display and quantification by a novel "motion-frozen" (MF) technique. METHODS: Three-dimensional LV contours were identified on images of the individual time phases. Three-dimensional phase-to-phase motion vectors were derived by sampling of the epi- and endocardial surfaces. A nonlinear image warping (thin-plate spline) was applied to warp all image phases to fit the end-diastolic (ED) phase. Warped images were created to provide the LV image in the ED phase but containing counts from an arbitrary number of time intervals. MF quantification has been performed using the same phase-to-phase motion vectors. MF normal perfusion limits were created from (99m)Tc sestamibi gated MPS studies of 40 females and 40 males with low likelihood (<5%) of coronary artery disease. All MF processing was completely automated. In the initial evaluation, we assessed the display quality and quantification of stress images using MF processing in 51 consecutive patients with 16-frame electrocardiographic gating and available coronary angiography. RESULTS: The display quality was significantly better for MF images as assessed visually. The MF images had the appearance of ED frames but were less noisy and of higher resolution than the summed images. MF images had higher maximum count values in the LV (116% +/- 6%) and higher contrast (12.5 +/- 7.7 vs. 9.5 +/- 3.2) than the corresponding summed images. The area under the receiver operator characteristic curve for prediction of stenoses > or = 70% by the MF method was 0.92 +/- 0.04 versus 0.89 +/- 0.04 by standard quantification (P = not significant). The computation time for automated MF quantification and warping was <25 s for each case. CONCLUSION: We have developed a novel technique for display and quantification of gated myocardial perfusion images, which retrospectively eliminates blur due to cardiac motion. Such processing of gated MPS appears to improve the effective resolution of images. Initial evaluation indicates that it may improve the accuracy of gated MPS in detection of coronary artery disease.

Aged↗

Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.

UNLABELLED: Image registration and fusion of whole-body (18)F-FDG PET with thoracic CT would allow combination of anatomic detail from CT with functional PET information, which could lead to improved diagnosis or PET-based radiotherapy planning. METHODS: We have designed a practical and fully automated algorithm for the elastic 3-dimensional image registration of whole-body PET and CT images, which compensates for the nonlinear deformation due to breath-hold CT imaging. A set of 18 PET and CT patient datasets has been evaluated by the algorithm. Initially, a 9-parameter linear registration is performed by maximizing the mutual information (MI)-based cost function, between the CT and the combination of emission and transmission PET volumes, using progressively increased matrix sizes to increase speed and provide better convergence. Subsequently, lung contours on transmission maps and corresponding contours on CT volumes are automatically detected. A large number (few hundreds) of corresponding point pairs are automatically derived, defining a thin-plate-spline (TPS) elastic transformation of PET emission and transmission scans to match the CT scan. RESULTS: In all 18 patients the automatic linear registration with multiresolution converged close to the final alignment, but, in 10 cases, the nonlinear differences in the diaphragm position and chest wall were still clearly visible. The nonlinear adjustment, which was in the order of 40-75 mm, significantly improved the alignment between breath-hold CT and PET, especially in the areas of the diaphragm. Lung volumes measured from transmission and CT scans match closely after the warping has been applied. The average computation time is <40 s for the linear component and <30 s for the nonlinear component for a typical PET scan with 4-6 bed positions. CONCLUSION: We have developed a technique for automatic nonlinear registration of CT and PET whole-body images to common spatial coordinates. This technique may be applied for automatic fusion of PET with CT acquired on stand-alone scanners during normal breathing or breath-hold data acquisition.

Algorithms↗

Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces: creating stereoscopic panoramas.

A major limitation of the use of endoscopes in minimally invasive surgery is the lack of relative context between the endoscope and its surroundings. The purpose of this work was to fuse images obtained from a tracked endoscope to surfaces derived from three-dimensional (3-D) preoperative magnetic resonance or computed tomography (CT) data, for assistance in surgical planning, training and guidance. We extracted polygonal surfaces from preoperative CT images of a standard brain phantom and digitized endoscopic video images from a tracked neuro-endoscope. The optical properties of the endoscope were characterized using a simple calibration procedure. Registration of the phantom (physical space) and CT images (preoperative image space) was accomplished using fiducial markers that could be identified both on the phantom and within the images. The endoscopic images were corrected for radial lens distortion and then mapped onto the extracted surfaces via a two-dimensional 2-D to 3-D mapping algorithm. The optical tracker has an accuracy of about 0.3 mm at its centroid, which allows the endoscope tip to be localized to within 1.0 mm. The mapping operation allows multiple endoscopic images to be "painted" onto the 3-D brain surfaces, as they are acquired, in the correct anatomical position. This allows panoramic and stereoscopic visualization, as well as navigation of the 3-D surface, painted with multiple endoscopic views, from arbitrary perspectives.

Algorithms↗

Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients.

BACKGROUND: The diagnostic value of gated myocardial perfusion single-photon emission computed tomography (MPS) with combined supine and prone acquisitions to detect coronary artery disease (CAD) in obese and nonobese patients has not been defined. METHODS AND RESULTS: We studied 1511 patients without prior myocardial infarction or coronary revascularization who either had coronary angiography within 3 months of MPS (n = 785) or had a low pretest likelihood of CAD (n = 726). All patients underwent rest thallium 201/gated exercise or adenosine stress technetium 99m sestamibi MPS in both the supine and prone positions. According to body mass index (BMI), patients were categorized as normal weight (BMI of 18.5-24.9 kg/m2), overweight (BMI of 25.0-29.9 kg/m2), or obese (BMI > or = 30.0 kg/m2). There were no significant differences in stress, fixed, or ischemic defects among patients in different weight categories. The sensitivity of MPS was 85%, 86%, and 89% for detecting patients with 50% or greater coronary stenosis and 89%, 91%, and 92% for detecting those with 70% or greater coronary stenosis in the normal-weight, overweight, and obese groups, respectively. Normalcy rates were nearly identical among the 3 weight groups (99%, 98%, and 99%, respectively). Multivariate logistic regression analysis further confirmed that BMI was a nonsignificant predictor for the detection of CAD. In a subset of 290 patients, automated quantitative MPS analysis confirmed that combined supine and prone MPS increased specificity (86%) in identifying CAD, without a significant reduction in sensitivity (83% for > or = 50% stenosis and 88% for > or = 70% stenosis). CONCLUSION: The findings of this study suggest that MPS performed with gating and combined supine and prone acquisitions without attenuation correction had a similar diagnostic accuracy for the detection of CAD in normal-weight, overweight, and obese patients.

Aged↗

Automated quantification of myocardial perfusion SPECT using simplified normal limits.

BACKGROUND: To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds. METHODS AND RESULTS: Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance. CONCLUSION: Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.

Aged↗