An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position.

We have designed and implemented a new stereotactic linac QA test with stereotactic precision. The test is used to characterize gantry sag, couch wobble, cone placement, MLC offsets, and room lasers' positions relative to the radiation isocenter. Two MLC star patterns, a cone pattern, and the laser line patterns are recorded on the same imaging medium. Phosphor plates are used as imaging medium due to their sensitivity to red light. The red light of room lasers erases some of the irradiation information stored on the phosphor plates enabling accurate and direct measurements for the position of room lasers and radiation isocenter. Using film instead of the phosphor plate as imaging medium is possible, however, it is less practical. The QA method consists of irradiating four phosphor plates that record the gantry sag between the 0 degrees and 180 degrees gantry angles, the position and stability of couch rotational axis, the sag between the 90 degrees and 270 degrees gantry angles, the accuracy of cone placement on the collimator, the MLC offsets from the collimator rotational axis, and the position of laser lines relative to the radiation isocenter. The estimated accuracy of the method is +/- 0.2 mm. The observed reproducibility of the method is about +/- 0.1 mm. The total irradiation/ illumination time is about 10 min per image. Data analysis, including the phosphor plate scanning, takes less than 5 min for each image. The method characterizes the radiation isocenter geometry with the high accuracy required for the stereotactic radiosurgery. In this respect, it is similar to the standard ball test for stereotactic machines. However, due to the usage of the MLC instead of the cross-hair/ball, it does not depend on the cross-hair/ball placement errors with respect to the lasers and it provides more information on the mechanical integrity of the linac/couch/laser system. Alternatively, it can be used as a highly accurate QA procedure for the nonstereotactic machines. Noteworthy is its ability to characterize the MLC position accuracy, which is an important factor in IMRT delivery.

Journal Article↗

Dynamic IMRT treatments of sinus region tumors: comparison of Monte Carlo calculations with treatment planning system calculations and ion chamber measurements.

Results are presented comparing Monte Carlo (MC) calculations for dynamic IMRT treatments of tumors in the sinus region with Eclipse treatment planning system dose calculations, and ion chamber measurements. The EGS4nrc MC code, BEAMnrc, was commissioned to simulate a Varian 21Ex Linac for both open and IMRT fields. The accuracy of the simulation for IMRT plans was evaluated using a head phantom by comparing MC, Eclipse, TLD results, and ion chamber in solid water phantom measurements. The MC code was then used to simulate dose distributions for five patients who were treated using dynamic IMRT for tumors in the sinus region. The results were compared with absolute and relative dose distributions calculated using Eclipse (pencil beam, modified-Batho inhomogeneity correction). Absolute dose differences were also compared with ion chamber results. Comparison of the doses calculated on the head phantom using MC, compared with Eclipse, ion chamber, and TLD measurements showed differences of -3.9%, -1.4%, and -2.0%, respectively (MC is colder). Relative dose distributions for the patient plans calculated using MC agreed well with those calculated using Eclipse with respect to targets and critical organs, indicating the modified-Batho correction is adequate. Average agreement for mean absolute target doses between MC and Eclipse was -3.0 +/-; 2.3% (1 s.d.). Agreement between ion chamber and Eclipse for these patients was -2.2 +/- 1.9%, compared with 0.2 +/- 2.0% for all head and neck IMRT patients. When Eclipse doses were corrected based on ion chamber results, agreement between MC and Eclipse was -0.7 +/- 2.0%, indicating a small systematic uncertainty in the doses calculated using the treatment planning system for this subset of patients.

Head and Neck Neoplasms↗

Maximum MLC opening effect in dynamic delivery of IMRT: leaf-positional analysis.

The analysis of dynamic multileaf collimator (MLC) positions for the delivered intensity-modulated radiotherapy (IMRT) plans is crucial in that it may capture dose delivery problems otherwise difficult to observe and quantify in the conventional dosimetric measurements with film or with an ionization chamber. In some IMRT systems, delivery of IMRT fields starts with a maximum MLC opening (roughly the shape of the target in the beam's-eye view) and then proceeds to the subsequent dynamic MLC subfields. No irradiation is required in going from the initial segment (maximum opening) to the next one, and theoretically, no dose should be delivered in that initial moment. However, due to a finite sampling time of the MLC controller, the finite speed of the MLC, and a finite leaf tolerance, there may be some dose delivered between the first and the second segment. The amount of the excess dose is higher for larger dose rates and for a smaller number of the total monitor units per IMRT field. The magnitude of the dose errors could be in the order of a few percent. Effects similar to the maximum MLC opening may occur in other situations as well, for instance, when leaves are forced to move over large distances in a short time. Confounding this are dose errors due to the uncertainty in the MLC transmission. The analysis of the actual leaf positions recorded in the dynamic MLC log file is helpful in differentiating between the two types of errors and in determining the optimal dynamic MLC delivery parameters.

Computer Simulation↗

Dependence of fluence errors in dynamic IMRT on leaf-positional errors varying with time and leaf number.

In d-MLC based IMRT, leaves move along a trajectory that lies within a user-defined tolerance (TOL) about the ideal trajectory specified in a d-MLC sequence file. The MLC controller measures leaf positions multiple times per second and corrects them if they deviate from ideal positions by a value greater than TOL. The magnitude of leaf-positional errors resulting from finite mechanical precision depends on the performance of the MLC motors executing leaf motions and is generally larger if leaves are forced to move at higher speeds. The maximum value of leaf-positional errors can be limited by decreasing TOL. However, due to the inherent time delay in the MLC controller, this may not happen at all times. Furthermore, decreasing the leaf tolerance results in a larger number of beam hold-offs, which, in turn leads, to a longer delivery time and, paradoxically, to higher chances of leaf-positional errors (< or = TOL). On the other end, the magnitude of leaf-positional errors depends on the complexity of the fluence map to be delivered. Recently, it has been shown that it is possible to determine the actual distribution of leaf-positional errors either by the imaging of moving MLC apertures with a digital imager or by analysis of a MLC log file saved by a MLC controller. This leads next to an important question: What is the relation between the distribution of leaf-positional errors and fluence errors. In this work, we introduce an analytical method to determine this relation in dynamic IMRT delivery. We model MLC errors as Random-Leaf Positional (RLP) errors described by a truncated normal distribution defined by two characteristic parameters: a standard deviation sigma and a cut-off value deltax0 (deltaxo approximately TOL). We quantify fluence errors for two cases: (i) deltax0 >> sigma (unrestricted normal distribution) and (ii) deltax0 << sigma (deltax0--limited normal distribution). We show that an average fluence error of an IMRT field is proportional to (i) sigma/ALPO and (ii) deltax0/ALPO, respectively, where ALPO is an Average Leaf Pair Opening (the concept of ALPO was previously introduced by us in Med. Phys. 28, 2220-2226 (2001). Therefore, dose errors associated with RLP errors are larger for fields requiring small leaf gaps. For an N-field IMRT plan, we demonstrate that the total fluence error (if we neglect inhomogeneities and scatter) is proportional to 1/square root of N, where N is the number of fields, which slightly reduces the impact of RLP errors of individual fields on the total fluence error. We tested and applied the analytical apparatus in the context of commercial inverse treatment planning systems used in our clinics (Helios and BrainScan). We determined the actual distribution of leaf-positional errors by studying MLC controller (Varian Mark II and Brainlab Novalis MLCs) log files created by the controller after each field delivery. The analytically derived relationship between fluence error and RLP errors was confirmed by numerical simulations. The equivalence of relative fluence error to relative dose error was verified by a direct dose calculation. We also experimentally verified the truthfulness of fluences derived from the log file data by comparing them to film data.

Humans↗