A new enzyme-linked chemiluminescent immunosorbent digoxin assay is virtually free from interference of spironolactone, potassium canrenoate, and their common metabolite canrenone.

Spironolactone and potassium canrenoate (aldosterone antagonist diuretics) are sometimes used in conjunction with digoxin for patient management. Spironolactone, potassium canrenoate, and their common metabolite canrenone interfere with serum digoxin measurement using various immunoassays. Recently a new enzyme-linked chemiluminescent immunosorbent digoxin assay (ECLIA-Digoxin) became commercially available for application on the ADVIA IMS 800i modular system (Bayer HealthCare, Tarrytown, NY). We investigated the potential interference of spironolactone and related compounds in this assay by comparing the results with the fluorescence polarization immunoassay (FPIA), which is known to have significant cross-reactivity with these compounds as well as a turbidimetric assay for digoxin with no known cross-reactivity with spironolactone and related compounds. Aliquots of drug free serum were supplemented with therapeutic and above therapeutic concentrations of spironolactone, canrenone, and potassium canrenoate, and apparent digoxin concentrations were measured. No apparent digoxin concentration was observed using the ECLIA-Digoxin or turbidimetric assay. When serum pools prepared from patients receiving digoxin were further supplemented with these compounds, we observed no significant change in digoxin concentrations in the presence of these compounds with the ECLIA-Digoxin. We conclude that this assay is virtually free from interferences from spironolactone, potassium canrenoate and their common metabolite canrenone.

Artifacts↗

The new enzyme-linked immunosorbent digoxin assay on the ADVIA Integrated Modular System is virtually free from oleander interference.

Despite known toxicity of oleander, this product is used in herbal preparations. Oleander interferes with various digoxin immunoassays. It is possible that a person taking digoxin also may take oleander-containing herbal products, and digoxin immunoassays interfering with oleander cannot be used for therapeutic monitoring of digoxin. Recently, Bayer Diagnostics introduced a new enzyme-linked chemiluminescent immunosorbent digoxin assay for application on the ADVIA IMS System (ECLIA-digoxin). We studied potential interference of oleander with this new digoxin assay and found that this assay is virtually free from oleander interference. When aliquots of drug-free serum pools were supplemented with ethyl alcohol extract of oleander leaf or pure oleandrin standard, we observed significant apparent digoxin concentration when measured by the fluorescence polarization immunoassay (FPIA) but minimal digoxin-like immunoreactivity using the ECLIA digoxin assay. Because cross-reactivity should be studied in the presence of primary analyte, we prepared 2 serum pools using sera from patients receiving digoxin. Then aliquots of first digoxin pool were supplemented with oleandrin standard and aliquots of second digoxin pool with oleander extract. We observed significant increases in apparent digoxin concentration in the presence of both oleandrin and oleander extract using the FPIA. However, we observed no statistically significant change in digoxin concentration when ECLIA digoxin assay was used, indicating that this assay is virtually free from oleander interference.

Cardenolides↗

False-positive serum tricyclic antidepressant concentrations using fluorescence polarization immunoassay due to the presence of hydroxyzine and cetirizine.

A recent report indicates that hydroxyzine and its active metabolite cetirizine interfere with the PENTINA carbamazepine assay. The potential interference of hydroxyzine and cetirizine with the fluorescence polarization immunoassay (FPIA) and CEDIA assay of carbamazepine as well as with the fluorescence polarization immunoassay of tricyclic antidepressants (TCA) was studied. Aliquots of drug-free serum pools were supplemented with various concentrations of hydroxyzine and cetirizine representing therapeutic, mild to moderate toxic as well as very toxic concentrations. Then apparent carbamazepine and TCA concentrations were measured by immunoassays. Although no interference of hydroxyzine and cetirizine was observed with carbamazepine assays (FPIA and CEDIA), significant apparent TCA concentrations were observed when aliquots of drug-free serum were supplemented with hydroxyzine or cetirizine. Mathematical formula was devised to predict hydroxyzine and/or cetirizine concentration in serum based on observed apparent TCA levels. Hydroxyzine and cetirizine also falsely increased total TCA values when aliquots of serum pool prepared from patients receiving TCA were further supplemented with these drugs. In conclusion, hydroxyzine and cetirizine do not interfere with the FPIA and CEDIA carbamazepine assays but interfere with the measurement of total TCA using the FPIA.

Antidepressive Agents, Tricyclic↗

New enzyme-linked chemiluminescent immunosorbent digoxin assay is free from interference of Chinese medicine DanShen.

DanShen is a traditional Chinese medicine indicated for cardiovascular diseases. The potential interference of DanShen with serum digoxin measurement was investigated using a new enzyme-linked chemiluminescent immunosorbent (ECLIA) digoxin assay. Aliquots of drug-free serum were supplemented with ethyl acetate extract of DanShen (4 different brands studied), and apparent digoxin concentrations were measured by the ECLIA as well as fluorescence polarization immunoassay (FPIA) and a turbidimetric assay for comparison. Mice were also fed 4 DanShen preparations and apparent digoxin concentrations were subsequently measured. In another experiment, serum pools containing digoxin were further supplemented with DanShen extracts and digoxin concentrations were measured again by all 3 assays. No apparent digoxin concentration was observed when aliquots of drug-free serum pools were supplemented with DanShen and digoxin concentrations were measured by the ECLIA or the turbidimetric assay. In contrast, significant apparent digoxin concentrations were observed using FPIA, and the highest apparent digoxin concentration was observed with brand 4 of DanShen extract. Similarly, when mice were fed with this herb, significant apparent digoxin concentrations were also observed using FPIA, but neither ECLIA nor turbidimetric assay showed any apparent digoxin concentration. When aliquots of digoxin pool were further supplemented with various DanShen extract, the apparent digoxin concentrations were significantly increased when FPIA was used. In contrast, digoxin concentrations in the presence of DanShen extract compared well with the digoxin concentration of the original pool when ECLIA or turbidimetric assay was used. We conclude that DanShen does not interfere with serum digoxin measurement using a more recently released ECLIA digoxin assay.

Animals↗

Analytical performance evaluation of a new turbidimetric immunoassay for valproic acid on the ADVIA 1650 analyzer: effect of gross hemolysis and high bilirubin.

Valproic acid is an anticonvulsant that requires careful therapeutic drug monitoring. Valproic acid is also used in psychiatric patients. Bayer Diagnostics (Tarrytown, NY) recently marketed a turbidimetric immunoassay for monitoring valproic acid concentrations in serum or plasma using the ADVIA 1650 analyzer. We evaluated the performance of this new assay by comparing it with a widely used fluorescence polarization immunoassay (FPIA) on the AxSYM analyzer (Abbott Laboratories, Abbott Park, IL). The total coefficient of variation (CV) for the low control of this new assay was 6.8% (mean = 30.7, SD = 2.1 microg/mL, n = 44) while the corresponding CVs for the medium and high controls were 3.3% (mean = 81.0, SD = 2.7 microg/mL, n = 44) and 5.9% (mean = 142.9, SD = 8.4 microg/mL, n = 44), respectively. The assay is linear up to a serum valproic acid concentration of 170 microg/mL, and the detection limit is 4.4 microg/mL. We observed an excellent correlation between the FPIA of valproic acid and the turbidimetric assay using specimens from 52 different patients who were receiving valproic acid. Using the valproic acid concentrations obtained by the FPIA as the x-axis, and the corresponding valproic acid concentrations obtained by the turbidimetric assay as the y-axis, we developed the following regression equation: y = 1.03 x+1.55 (r = 0.98). With this new assay, high concentrations of bilirubin (unconjugated 30 mg/dL and conjugated 30 mg/dL) and gross hemolysis (4+, hemoglobin: 1,500 mg/dL) have no effect on measurements of valproic acid concentration. We conclude that the new turbidimetric assay for valproic acid can be used for routine therapeutic drug monitoring of valproic acid in clinical laboratories.

Anticonvulsants↗

Analytic performance evaluation of a new turbidimetric immunoassay for carbamazepine on the ADVIA 1650 analyzer: effect of carbamazepine 10,11-epoxide.

Carbamazepine, an anticonvulsant, requires therapeutic drug monitoring. Recently Bayer HealthCare, Diagnostics Division released a turbidimetric immunoassay of carbamazepine on the ADVIA 1650 analyzer. We evaluated the analytic performance of this assay by comparing values obtained with this new assay in sera of 54 patients receiving carbamazepine with the values obtained by using a widely used fluorescence polarization immunoassay (FPIA) and a chemiluminescent immunoassay (CLIA). The new turbidimetric immunoassay for carbamazepine showed excellent precision. The low control showed a total CV of 4.9% (mean 2.86, SD 0.14 microg/mL), the medium control demonstrated a total CV of 3.5% (mean 7.79, SD 0.27 microg/mL), and the high control showed a total CV of 4.8% (mean 16.15, SD 0.78 microg/mL). The assay was linear up to a carbamazepine concentration of 20 microg/mL. The assay showed excellent dilution recovery and recovery of samples supplemented with carbamazepine (mean recovery 102.2%). We observed an excellent correlation between the values obtained by the FPIA (x-axis) assay and the new turbidimetric (y-axis) assay (y = 0.96 x - 0.46, r = 0.99, n = 54). We also observed excellent correlation between the values obtained by the CLIA (x-axis) and the turbidimetric (y-axis) assay (y = 1.10 x -0.32, r = 0.99, n = 54). However, the slope of 1.10 was higher than the slope of 0.96 observed with the regression equation obtained by using values obtained by the FPIA and the turbidimetric assay. The positive bias obtained with the new turbidimetric assay compared with the CLIA assay resulted from lower cross reactivity of carbamazepine 10,11-epoxide, the active metabolite of carbamazepine, with CLIA. On the other hand, the cross reactivity of the metabolite is similar between the new turbidimetric assay and the FPIA assay. We conclude that the new turbidimetric assay can be used for routine monitoring of carbamazepine in clinical laboratories.

Carbamazepine↗

New enzyme-linked immunosorbent digoxin assay on the ADVIA IMS 800i system is virtually free from interference of endogenous digoxin-like immunoreactive factors.

Endogenous digoxin-like immunoreactive factors (DLIF) may crossreact with antidigoxin antibody and falsely elevate immunoassay results. Recently, a new enzyme-linked immunosorbent chemiluminescent assay for digoxin has been available for use on the ADVIA IMS (Integrated Modular System) 800i analyzer (Bayer Diagnostics). We studied potential interference of DLIF with this new digoxin assay. We analyzed 30 serum specimens from patients who have pathologic conditions that may increase serum DLIF concentrations. These patients were never exposed to digoxin or other agents that may lead to a measurable digoxin concentration. We also analyzed 10 specimens from neonates, 10 cord blood specimens, and 10 amniotic fluid specimens. Apparent digoxin concentrations were measured using the new enzyme-linked immunosorbent digoxin assay (IMS-Digoxin), a fluorescence polarization immunoassay (FPIA), and also a chemiluminescent immunoassay (CLIA, run on ACS:180(R) system from Bayer Diagnostics). We observed measurable apparent digoxin levels with the FPIA in 4 uremic patients (range 0.21-0.36 ng/mL, digoxin equivalent), 7 patients with liver disease (range 0.21-0.72 ng/mL), and 3 patients in the third trimester of pregnancy (0.22-0.66 ng/mL). We also observed measurable DLIF concentrations with the FPIA in 2 neonates (0.22 and 0.36 ng/mL), 5 cord blood specimens (range 0.21-1.18 ng/mL), and 5 amniotic fluid specimens (0.21-0.50 ng/mL). None of these DLIF-positive specimens showed any measurable digoxin concentration using the IMS-Digoxin or the CLIA assay. When serum specimens containing elevated concentrations of DLIF but no digoxin (as measured by FPIA) were supplemented with known concentrations of digoxin, we observed falsely elevated digoxin concentrations, as expected, only by the FPIA. In contrast, we observed a good agreement between the target and observed concentrations when the new IMS-Digoxin or the CLIA assay was used. We conclude that the IMS-Digoxin assay is free from interference of DLIF.

Adult↗

Analytic performance evaluation of a new turbidimetric immunoassay for phenytoin on the ADVIA 1650 analyzer: effect of phenytoin metabolite and analogue.

Phenytoin is an anticonvulsant that requires therapeutic drug monitoring. Recently, Bayer HealthCare, Diagnostics Division released a turbidimetric immunoassay of phenytoin on the ADVIA 1650 analyzer. We evaluated the analytic performance of this assay by comparing values obtained in 52 patients receiving Phenytoin using this new assay with the values obtained by using a widely used fluorescence polarization immunoassay (FPIA). The new turbidimetric immunoassay for phenytoin showed the following imprecision with the low, medium, and high controls: total CV of 5.2% (mean 4.81 microg/mL), 3.7% (mean 16.24 microg/mL), and 4.1% (mean 22.65 microg/mL), respectively. The detection limit of the assay was 0.79 microg/mL, and the assay was linear up to a phenytoin concentration of 46.1 microg/mL. The assay showed excellent dilution recovery and recovery of spiked samples (mean recovery 101.4% and 94.4%, respectively). We observed an excellent correlation between the values obtained by the FPIA (x-axis) assay and the new turbidimetric (y-axis) assay (y=1.06 x-0.61, r=0.98, n=52). We also determined the cross-reactivity of 5-(p-hydroxyphenyl)-5-phenylhydantoin (HPPH), a major metabolite of phenytoin, and of oxaprozine, an analogue with a similar chemical structure to phenytoin, in both phenytoin assays. Both assays showed almost no cross-reactivity to oxaprozine and only small (5%-8%) cross-reactivity to HPPH. We also found that the turbidimetric assay was free from interference at least up to 1200 mg/dL of hemolysis, 30 mg/dL of free bilirubin, 34.5 mg/dL of conjugated bilirubin, and 750 mg/dL of triglyceride (Intralipid). When a drug-free serum was followed by a serum sample containing 38.5 microg/mL of phenytoin, no sample probe carryover effect was observed. We conclude that the new turbidimetric assay can be used for routine monitoring of phenytoin in clinical laboratories.

Bilirubin↗

Interference of endogenous digoxin-like immunoreactive factors in serum digoxin measurement is minimized in a new turbidimetric digoxin immunoassay on ADVIA 1650 analyzer.

Endogenous digoxin-like immunoreactive factors (DLIF) cross-react with antidigoxin antibody and falsely elevate or lower measured serum digoxin concentrations, depending on the assay design. Recently, Bayer Diagnostics released a turbidimetric assay for digoxin on the ADVIA 1650 analyzer. We studied potential interference of DLIF with this new digoxin assay. We analyzed 40 serum specimens from patients who have pathologic conditions that may increase serum DLIF concentrations. These patients were never exposed to digoxin or other agents that may lead to a measurable digoxin concentration. We also analyzed five specimens from autopsy and five specimens from neonates. Apparent digoxin concentrations were measured using the new turbidimetric digoxin assay, the fluorescence polarization immunoassay (FPIA, Abbott Laboratories, Abbott Park, IL), and also the chemiluminescent immunoassay (CLIA, Bayer Diagnostics). We observed measurable apparent digoxin levels with the FPIA in 5 uremic patients (range 0.24-0.86 ng/mL), 6 patients with liver disease (range 0.21-0.72 ng/mL), in 3 patients in the third trimester of pregnancy (0.21-26 ng/mL), and in 3 neonates (range 0.21-0.46 ng/mL). Four out of 5 autopsy specimens showed measurable apparent digoxin concentrations (0.23-0.81 ng/mL). In contrast, only 1 specimen (a uremic patient) showed an apparent digoxin concentration of 0.26 ng/mL with the turbidimetric digoxin immunoassay (FPIA value 0.86 ng/mL, CLIA value 0.32 ng/mL). Because DLIF is absent in the protein-free ultrafiltrate, we also measured free digoxin concentrations in DLIF-positive patients to ensure that the apparent digoxin concentrations were caused by DLIF. We observed no apparent digoxin concentrations in the protein-free ultrafiltrate in any DLIF-positive specimens. When serum specimens containing elevated concentrations of DLIF but no digoxin were supplemented with a known concentration of digoxin, we observed falsely elevated digoxin concentrations by the FPIA, as expected. In contrast, we observed a good agreement between the target and observed concentrations when the new turbidimetric assay was used. We conclude that DLIF has minimal effect on serum digoxin measurements by the new turbidimetric assay.

Adult↗

Rapid detection of oleander poisoning using digoxin immunoassays: comparison of five assays.

Oleander is an ornamental shrub that grows in the United States, Australia, India, Sri Lanka, China, and other parts of the world. All parts of the plant are poisonous because the presence of cardiac glycoside oleandrin. Despite its toxicity, oleander extract is used in folk medicines. Because of its structural similarity, oleandrin cross-reacts with the fluorescence polarization immunoassay (FPIA) for digoxin. We studied the potential of detecting oleandrin in serum using 5 common digoxin immunoassays (FPIA, MEIA, both from Abbott; Beckman digoxin assay on Synchron LX, Chemiluminescent assay, CLIA from Bayer Diagnostics) and a recently FDA-approved turbidimetric assay on the ADVIA 1650 analyzer (Bayer). Aliquots of drug-free and digoxin-like immunoreactive substances (DLIS)-free serum pools were supplemented with ethanol extract of oleander leaves or oleandrin (Sigma Chemicals) in amounts expected in vivo after severe overdose. We observed significant apparent digoxin concentration with FPIA, Beckman, and the new turbidimetric assay (1 mL drug-free serum supplemented with 5.0 microL of oleander extract: apparent digoxin 2.36 ng/mL by the FPIA, 0.32 ng/mL by the MEIA, 0.93 ng/mL by the Beckman, 0.82 ng/mL by the new turbidimetric assay). The CLIA showed no cross-reactivity. Similar observations were made when serum pools were supplemented with oleandrin. Because cross reactivity should be tested in the presence of the primary analyte, we supplemented serum pools prepared from patients receiving digoxin with oleander extract or oleandrin. The measured digoxin concentrations were falsely elevated with the FPIA, Beckman, and turbidimetric assays, the highest false elevation being observed with the FPIA. Surprisingly, apparent digoxin concentrations were falsely lowered when MEIA was used. Digibind neutralizes free apparent digoxin concentration in vitro in serum pools supplemented with oleander extract, and this effect can be measured by the FPIA. We conclude that FPIA is most sensitive to detect the presence of oleander in serum. In contrast, the CLIA (no cross-reactivity) should be used for monitoring digoxin in a patient receiving digoxin and self-medicated with a herbal remedy containing oleander.

Confidence Intervals↗

Evaluation of an automated chemiluminescent immunoassay for complexed PSA on the Bayer ACS:180 system.

Prostate-specific antigen (PSA), the most important tumor marker for the detection of prostate cancer, exists in serum in a free, uncomplexed form (free PSA [fPSA]), and as bound to protease inhibitors (mainly alpha1-antichymotrypsin [ACT]). The measurement of complexed PSA (cPSA) concentration in serum has been shown to have better sensitivity and specificity than serum total PSA concentration. A new chemiluminescent immunoassay for cPSA for use on the Bayer ACS:180 fully automated system (Bayer Corp, Tarrytown, NY) has been developed and evaluated. The precision of the new assay was <3.9% (within-run coefficient of variation [CV]) and <5.0% (total CV). The analytical sensitivity (95% upper limit of noise at zero calibrator) was <0.03 ng/mL. A comparison of the ACS:180 cPSA results with the cPSA concentrations calculated from the ACCESS (Beckman-Coulter) PSA and fPSA assays yielded the following regression equation: ACS:180 cPSA=0.93* (calculated ACCESS cPSA)+0.43, R=0.993, n=95. The mean dilution and spike recovery for five samples were both 98%. No interference was observed from hemoglobin, triglyceride, or bilirubin (NCCLS protocol). These results indicate that the ACS:180 cPSA assay is precise, and compares well with the calculated cPSA from ACCESS total and free-PSA results.

Antigen-Antibody Reactions↗

A new turbidometric digoxin immunoassay on the ADVIA 1650 analyzer is free from interference by spironolactone, potassium canrenoate, and their common metabolite canrenone.

Spironolactone and potassium canrenoate (aldosterone antagonist diuretics) are often used with digoxin in clinical practice. It has been well documented in the literature that spironolactone, potassium canrenoate, and their common metabolite canrenone cross-react with the fluorescence polarization immunoassay (FPIA) for digoxin and falsely elevate measured serum digoxin concentrations. Recently a new turbidometric assay for digoxin became commercially available from Bayer Diagnostic for application on the ADVIA 1650 Chemistry analyzer. We studied the potential interference of these compounds in this new digoxin assay. Aliquots of drug-free serum were supplemented with therapeutic and above-therapeutic concentrations of spironolactone, canrenone, and potassium canrenoate, and apparent digoxin concentrations were measured. We observed apparent digoxin concentrations with the FPIA digoxin assay as expected but observed no apparent digoxin levels with the new turbidometric immunoassay. When serum pools prepared from patients receiving digoxin were supplemented with these compounds in concentrations expected in serum in patients receiving these medications, we observed falsely elevated digoxin levels with the FPIA digoxin assay, but no statistically significant change was observed with the new turbidometric assay. We conclude that the new turbidometric assay for digoxin is free from interference by spironolactone, potassium canrenoate, and their common metabolite canrenone.

Canrenoic Acid↗

Effect of Asian and Siberian ginseng on serum digoxin measurement by five digoxin immunoassays. Significant variation in digoxin-like immunoreactivity among commercial ginsengs.

Asian and Siberian ginsengs contain glycosides with structural similarities to digoxin. We studied potential interference of ginseng in 5 digoxin immunoassays in 3 Asian (2 liquid extracts, 1 capsule) and 3 Siberian ginseng preparations (1 liquid extract, 2 capsules). With the fluorescence polarization immunoassay (FPIA), we observed apparent digoxin activity in 1 Asian liquid preparation and in the liquid extract and 1 capsule form of Siberian ginseng. In mice fed ginseng, we observed digoxin activities in the serum (Asian, 0.48-0.68 ng/mL [0.6-0.9 nmol/L]; Siberian, 0.20-0.47 ng/mL [0.3-0.6 nmol/L]), indicating that such interferences also occur in vivo. Serum pools prepared from samples from patients receiving digoxin and then supplemented with Asian or Siberian ginseng showed falsely increased digoxin values using the FPIA (e.g., for Asian ginseng, 1.54 ng/mL [2.0 nmol/L] vs control value, 1.10 ng/mL [1.4 nmol/L]) and falsely decreased values using the microparticle enzyme immunoassay (MEIA; 0.73 ng/mL [0.9 nmol/L] vs control value, 1.04 ng/mL [1.3 nmol/L]). Digoxin-like immunoreactive substances (DLISs) showed synergistic effects with ginsengs in interfering with the FPIA and MEIA for digoxin. No interference was observed with 3 other digoxin assays, even in the presence of elevated DLISs.

Animals↗

Bidirectional (positive/negative) interference of spironolactone, canrenone, and potassium canrenoate on serum digoxin measurement: elimination of interference by measuring free digoxin or using a chemiluminescent assay for digoxin.

Spironolactone and potassium canrenoate (aldosterone antagonist diuretics) are often used with digoxin in clinical practice. Spironolactone, potassium canrenoate, and their common metabolite canrenone cross-react with the fluorescence polarization immunoassay (FPIA) for digoxin, and can falsely elevate serum digoxin concentrations. Serum digoxin concentrations were falsely lowered when the microparticle enzyme immunoassay (MEIA) was used. Aliquots of drug-free serum were supplemented with therapeutic and above-therapeutic concentrations of spironolactone, canrenone, and potassium canrenoate, and apparent digoxin activities were measured. We observed digoxin-like activities in the FPIA, but observed no activity with the MEIA or the chemiluminescent assay (CLIA). However, when serum digoxin pools prepared from patients receiving digoxin were supplemented with these compounds, we observed suppression of total digoxin levels with the MEIA. In contrast, no interference was observed in the presence of these compounds when CLIA was used for digoxin measurement. These compounds are strongly protein-bound, and no apparent digoxin activity was observed in the protein-free ultrafiltrate when drug-free sera were spiked with high levels of these compounds. Taking advantage of strong protein binding of these compounds and weak protein binding of digoxin (25%), interference of spironolactone, canrenone, and potassium canrenoate in FPIA and MEIA digoxin assays can be mostly eliminated by monitoring free digoxin concentration. Another approach to avoid this interference is to use the CLIA digoxin assay.

Canrenoic Acid↗

In vivo digoxin-like immunoreactivity in mice and interference of Chinese medicine Danshen in serum digoxin measurement: elimination of interference by using a chemiluminescent assay.

BACKGROUND: Danshen, a traditional Chinese medicine used in the management of cardiovascular diseases, is available without prescription in the US. Because Danshen is used to treat cardiovascular diseases, we studied the potential interference of Danshen with serum digoxin measurement using various immunoassays. METHODS: Blood was collected 1 day before and then 1 and 2 h after feeding mice with Danshen. The apparent digitoxin activities were measured by the fluorescence polarization immunoassay (FPIA). We also added microliter amounts of Danshen extract to digoxin pools prepared from patients receiving digoxin. The digoxin concentrations were measured using the fluorescence polarization immunoassay (FPIA), microparticle enzyme immunoassay (MEIA) and chemiluminescent assay (CLIA). The observed values were compared with original values. We also fed mice with Danshen. RESULTS: We observed measurable digoxin-like immunoreactivity in sera of mice after feeding with Danshen. We also observed falsely lower digoxin concentrations (negative interference) when MEIA was used for digoxin measurement. However, serum digoxin concentrations were falsely elevated with FPIA. We observed no interference of Danshen in serum digoxin measurement using the CLIA. CONCLUSION: Danshen appears to contain digoxin-like immunoreactivity but does not interfere with serum digoxin measurement when CLIA was used.

Animals↗

Effect of Chinese medicines Chan Su and Danshen on EMIT 2000 and Randox digoxin immunoassays: wide variation in digoxin-like immunoreactivity and magnitude of interference in digoxin measurement by different brands of the same product.

Chan Su is a Chinese medicine prepared from the skin gland of a Chinese toad and is used in treating arrhythmia and other heart diseases. Danshen is prepared from the Chinese medicinal plant and is used for various cardiovascular diseases including angina pectoris. The authors studied the potential interference of such medicines with the widely used EMIT 2000 (Dade Behring; Deerpark, IL) digoxin assay and the recently marketed Randox digoxin assay (Randox Laboratories Ltd, Antrim, United Kingdom) (both run on the Bayer ADVIA 1650 analyzer) (Bayer Diagnostics, Tarrytown, NY) and compared their results with an FPIA (Abbott Laboratories) and a chemiluminescent immunoassay (CLIA; Bayer Diagnostics) for digoxin. Aliquots of drug-free serum were supplemented with 1 microL ethyl acetate extract of Danshen or aqueous extract of Chan Su, and apparent digoxin concentrations were measured by all four digoxin immunoassays (FPIA, EMIT, Randox, CLIA). The authors also supplemented aliquots of several different serum pools prepared from patients taking digoxin with very small amounts of Chan Su or Danshen extract and compared digoxin values with the control digoxin values (serum pool containing no Chinese medicine). The authors observed no interference of Danshen in either EMIT, Randox, or CLIA assay but observed an interference with the FPIA assay. On the other hand, the authors observed high interference of Chan Su in the FPIA assay but moderate interference with the EMIT 2000 and Randox digoxin assays. CLIA assay was again free from any interference. The authors also observed a wide variation in digoxin-like immunoreactivity and magnitude of interference in digoxin immunoassay in different brands of Chan Su and Danshen, indicating poor quality control in manufacturing of these Chinese medicines. Taking advantage of the high protein binding of digoxin-like immunoreactive components of Chan Su, the authors further demonstrated that interference of Chan Su in EMIT 2000 and Randox assays can be mostly eliminated by monitoring free digoxin.

Bufanolides↗