PubMed Health⌕ Search

Biomedical subjects

Pramod Upadhyay

Publications and source records attributed to Pramod Upadhyay.

4 recordsLinked to original sources

Enhanced transdermal-immunization with diptheria-toxoid using local hyperthermia.

In this study we have investigated how mild local hyperthermia could be used for transdermal-immunization. Mild hyperthermia is found unique in many ways. It activates the immune system and it also results in higher mass transport of high molecular weight molecules and nanometer size quantum dots labeled antigens across the skin in experimental animals. Hyperthermia increases the expression of co-stimulatory molecules such as CD80 and CD86. Mice transdermally immunized with diphtheria toxoid, without any adjuvant or penetration enhancing reagent but under the conditions of local hyperthermia generate an antibody response. In the memory recall assay, the splenocytes of hyperthermia enhanced transdermal-immunized mice undergo proliferation, when exposed to diphtheria toxoid. Comparable response was generated when mice were immunized with diphtheria toxoid by hyperthermia enhanced transdermal route or by conventional inter-muscular injection. Hyperthermia enhanced transdermal-immunization procedure is likely to have higher compliance as it does not cause any pain or visible damage to the skin.

Administration, Cutaneous↗

Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering.

BACKGROUND: The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. METHODS: POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. RESULTS: The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. CONCLUSION: Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.

Bandages↗

Design and evaluation of an aerosol infection chamber for small animals.

In this report, we describe the design of an aerosol exposure chamber to reproducibly produce uniformly distributed clouds of droplet nuclei. The device can deliver desired number of bacilli (20-2000) in lungs of mice. All safety measures to handle infectious bacteria have been incorporated in the design and it is controlled remotely by a personal computer. It is an indispensable device to study the protective efficacy of vaccine candidates against Mycobacterium tuberculosis infection. This device would also be useful to study immunization and drug delivery by nasal route in experimental animals.

Aerosols↗

A novel ultrasound-enhanced latex agglutination test for the detection of antibodies against Mycobacterium tuberculosis in serum.

A novel ultrasound-enhanced latex agglutination test is described for the detection of serum antibodies against Mycobacterium tuberculosis. The use of ultrasound to detect the low level of antibodies in serum enhances the sensitivity of the test. The technique is based on the fact that suspended latex particles become concentrated in an ultrasonic standing wave field, thereby increasing the rate of particle-particle collisions compared to the standard agglutination test procedure. Reactions were performed on piezo-ceramic wafers, which were connected to an oscillator at a frequency of 100 kHz. This method improved sensitivity significantly so that even 20 times diluted serum samples exhibited agglutination, which was clearly visible to the naked eye.

Antibodies, Bacterial↗