PubMed Health⌕ Search

Biomedical subjects

Prashanthi Vemuri

Publications and source records attributed to Prashanthi Vemuri.

2 recordsLinked to original sources

Automatic detection of three-dimensional vascular tree centerlines and bifurcations in high-resolution magnetic resonance angiography.

OBJECTIVES: We sought to develop a simple and robust algorithm capable of automatically detecting centerlines and bifurcations of a three-dimensional (3D) vascular bed. MATERIALS AND METHODS: After necessary preprocessing, an appropriate cost function is computed for all vessel voxels and Dijkstra's minimum-cost-path algorithm is implemented. By back tracing all the minimum-cost paths, centerlines and bifurcation are detected. The detected paths are then split into segments between adjacent nodes (bifurcations or vessel end-points) and smoothed by curve fitting. RESULTS: Application of the algorithm to both simulated 3D vessels and 3D magnetic resonance angiography (MRA) images of an actual intracranial arterial tree produced well-centered vessel skeletons. Quantitative assessment of the algorithm was performed. For the simulated data, the root mean square error for centerline detection is about half a voxel. For the human intracranial MRA data, the sensitivity, positive predictive value (PPV), and accuracy of bifurcation detection were calculated for different cost functions. The best case gave a sensitivity of 91.4%, a PPV of 91.4%, and an RMS error of 1.7 voxels. CONCLUSIONS: To the extent that imperfections are eliminated from the segmented image, the algorithm is effective and robust in automatic and accurate detection of centerlines and bifurcations. The cost function and algorithm used are demonstrated to be an improvement over similar algorithms in the literature.

Algorithms↗

Statistics-based approach for aneurysm volume measurements.

PURPOSE: To evaluate the ability of high-resolution MRA to monitor changes in intracranial aneurysm volume, and devise a highly reliable technique for obtaining these measurements. MATERIALS AND METHODS: To obtain a baseline estimate of the repeatability of MRA scans and validate the statistics-based technique for aneurysm volume measurement, multiple scans were obtained on individual subjects over a period of up to 1 year. These 3D MRA data sets were coregistered and then analyzed using the volumetric analysis of segmented data and the proposed statistical method. RESULTS: It was shown that high-resolution MRA provides highly repeatable data sets. Both methods used for the aneurysm volume measurements showed consistent results. However, the proposed statistical method had lower error and was much less sensitive to the choice of segmentation parameter than the volumetric analysis of segmented data. A change of 1 mm in the average radius of the aneurysm was detectable with the statistics-based technique. CONCLUSIONS: This study demonstrates that the statistical method of aneurysm volume measurement in high-resolution MRA allows reliable and accurate assessments of aneurysm volume changes.

Cerebrovascular Circulation↗