PubMed Health⌕ Search

Biomedical subjects

Priti Mulchandani

Publications and source records attributed to Priti Mulchandani.

5 recordsLinked to original sources

Organophosphorus hydrolase multilayer modified microcantilevers for organophosphorus detection.

We report a biosensor based on organophosphorus hydrolase (OPH) multilayer modified microcantilever (MCL) for detection of organophosphorus compounds (OPs). The assay is based on substrate-dependent bending of the OPH functionalized MCLs. The cantilever bending amplitude at equilibrium was a function of the concentration of paraoxon with the dynamic range extending from 10(-7) to 10(-3)M. The lower detection limit of approximately 10(-7)M for paraoxon was an order of magnitude better than the OPH-based potentiometric and optical biosensors based on pH modulation. There was a good intra-sensor and an acceptable inter-sensor reproducibility as evidenced by the standard errors of 5% and 15%, respectively. OPs measured using this technique included parathion and diisopropyl fluorophosphate (DFP) in the order of paraoxon>DFP>parathion. The conformational change of the OPH was most likely the main origin of MCL bending.

Aryldialkylphosphatase↗

Highly sensitive and selective amperometric microbial biosensor for direct determination of p-nitrophenyl-substituted organophosphate nerve agents.

We report herein a whole cell-based amperometric biosensor for highly selective, highly sensitive, direct, single-step, rapid, and cost-effective determination of organophosphate pesticides with a p-nitrophenyl substituent. The biosensor was comprised of a p-nitrophenol degrader, Pseudomonas putida JS444, genetically engineered to express organophosphorus hydrolase (OPH) on the cell surface immobilized on the carbon paste electrode. Surface-expressed OPH catalyzed hydrolysis of the p-nitrophenyl substituent organophosphorus pesticides such as paraoxon, parathion, and methyl parathion to release p-nitrophenol, which was subsequently degraded by the enzymatic machinery of P. putida JS444. The electrooxidization current of the intermediates was measured and correlated to the concentration of organophosphates. The best sensitivity and response time were obtained using a sensor constructed with 0.086 mg dry weight of cells operating at 600 mV applied potential (vs Ag/AgCl reference) in 50 mM citrate--phosphate pH 7.5 buffer with 50 microM CoCl2 at room temperature. Under optimum operating conditions the biosensor measured as low as 0.28 ppb of paraoxon, 0.26 ppb of methyl parathion, and 0.29 ppb parathion. These detection limits are comparable to cholinesterase inhibition-based biosensors. Unlike the inhibition-based format, this biosensor manifests a selective response to organophosphate pesticides with a p-nitrophenyl substituent only, has a simplified single-step protocol with short response time, and can be used for repetitive/multiple and on-line analysis. The service life of the microbial amperometric biosensor was 5 days when stored in the operating buffer at 4 degrees C. The new biosensor offers great promise for rapid environmental monitoring of OP pesticides with nitrophenyl substituent.

Aryldialkylphosphatase↗

Direct determination of p-nitrophenyl substituent organophosphorus nerve agents using a recombinant Pseudomonas putida JS444-modified Clark oxygen electrode.

A microbial biosensor for rapid, sensitive, selective, and cost-effective determination of the total content of organophosphorus nerve agents with p-nitrophenyl substituent is reported. The biosensor consisted of genetically engineered PNP-degrader Pseudomonas putida JS444 expressing organophosphorus hydrolase (OPH) on its cell surface immobilized on a dissolved oxygen electrode. Surface-expressed OPH catalyzed the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, methyl parathion, and parathion to release p-nitrophenol that was oxidized by the enzymatic machinery of Pseudomonas putida JS444 to carbon dioxide while consuming oxygen. The oxygen consumption was measured and correlated to the concentration of organophosphates. The sensor signal and response time were optimized with 0.086 mg dry weight of cell and operating in 50 mM pH 7.5 citrate-phosphate buffer with 50 microM CoCl(2) at room temperature. When operated at optimized conditions, the biosensor measured as low as 55 ppb of paraoxon, 53 ppb of methyl parathion, and 58 ppb of parathion without interference from most phenolic compounds and other commonly used pesticides, such as atrazine, coumaphos, sutan, sevin, and diazinon. The operational life of the microbial biosensor was approximately 5 days when stored in the operating buffer at 4 degrees C.

Aryldialkylphosphatase↗

Amperometric microbial biosensor for p-nitrophenol using Moraxella sp.-modified carbon paste electrode.

An amperometric microbial biosensor for highly specific, sensitive and rapid quantitative determination of p-nitrophenol was developed. The biosensor takes advantage of the ability of Moraxella sp. to specifically degrade p-nitrophenol to hydroquinone, a more electroactive compound than p-nitrophenol. The electrochemical oxidation current of hydroquinone formed in biodegradation of p-nitrophenol was measured at Moraxella sp.-modified carbon paste electrode and correlated to p-phenol concentrations. The optimum response was realized by electrode constructed using 15 mg of dry cell weight per 1 g of carbon paste and operating at 0.3 V (versus Ag/AgCl reference) in pH 7.5, 20 mM sodium phosphate buffer. Operating at these optimum conditions the biosensor had excellent selectivity against phenol derivatives and was able to measure as low as 20 nM (2.78 ppb) p-nitrophenol with very good accuracy and reproducibility. The biosensor was stable for approximately 3 weeks when stored at 4 degrees C. The applicability of the biosensor to measure p-nitrophenol in lake water was demonstrated.

Biological Assay↗

Whole cell-enzyme hybrid amperometric biosensor for direct determination of organophosphorous nerve agents with p-nitrophenyl substituent.

In this paper, we reported the construction of a hybrid biosensor for direct, highly selective, sensitive, and rapid quantitative determination of organophosphate pesticides with p-nitrophenyl substituent using purified organophosphorus hydrolase (OPH) for the initial hydrolysis and Arthrobacter sp. JS443 for subsequent p-nitrophenol oxidation. The biocatalytic layer was prepared by co-immobilizing Arthrobacter sp. JS443 and OPH on a carbon paste electrode. OPH catalyzed the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon and methyl parathion to release p-nitrophenol that was oxidized by the enzymatic machinery of Arthrobacter sp. JS443 to carbon dioxide through electroactive intermediates 4-nitrocatechol and 1,2,4-benzenetriol. The oxidization current of the intermediates was measured and correlated to the concentration of organophosphates. The best sensitivity and response time were obtained using a sensor constructed with 0.06 mg dry weight of cell and 965 IU of OPH operating at 400 mV applied potential (vs. Ag/AgCl reference) in 50 mM citrate-phosphate pH 7.5 buffer at room temperature. Using these conditions, the biosensor measured as low as 2.8 ppb (10 nM) of paraoxon and 5.3 ppb (20 nM) of methyl parathion without interference from phenolic compounds, carbamate pesticides, triazine herbicides, and organophosphate pesticides that do not have the p-nitrophenyl substituent. The biosensor had excellent operational life-time stability with no decrease in response for more than 40 repeated uses over a 12-h period when stored at room temperature, while its storage life was approximately 2 days when stored in the operating buffer at 4 degrees C.

Actinobacteria↗