PubMed Health⌕ Search

Biomedical subjects

Purnendu K Dasgupta

Publications and source records attributed to Purnendu K Dasgupta.

At least 19 recordsLinked to original sources

Tailoring elution of tetraalkylammonium ions. Ideal electrostatic selectivity elution order on a polymeric ion exchanger.

Although ion exchange is often depicted as a process driven by electrostatic forces, ionic solvation or hydrophobic forces contribute greatly to ion exchange selectivity and is often the dominant factor. On a variety of commercial anion exchange columns, monovalent ClO4- elutes after doubly charged SO42- and even triply charged PO43-. For identically charged alkali metal ions, electrostatic charge densities based on crystal radii would suggest Li+ to be the most strongly retained on a cation exchanger. In practice, it is typically the least strongly held cation on most cation exchangers, because of its very high hydration energy and with most eluents its capacity factor approaches zero. Even when the ion is very poorly solvated, as with tetraalkylammonium (NR4+) cations, there has never been a report on a polymeric ion exchanger of an ideal electrostatic selectivity order where NR4+ cations elute in their increasing charge density order: R = n-butyl first, followed by n-propyl, ethyl, and last, methyl. We show that this selectivity order is easily achieved on recently described methracrylate-based monolithic capillary cation exchange columns (Ueki, Y.; Umemura, T.; Li, J. X.; Odake, T; Tsunoda, K. Anal. Chem. 2004, 76, 7007-7012) with minor amounts of hydroorganic modifiers. Indeed, under such conditions, Li+ (and other alkali cations) elutes after NMe4+.

Journal Article↗

Perchlorate in the United States. Analysis of relative source contributions to the food chain.

Perchlorate has been considered by some a potential threat to human health, especially to developing infants and children because it may inhibit iodide uptake by the sodium iodide symporter (NIS) of the thyroid. In the United States, during the last several decades, environmental perchlorate has had three recognized sources stemming from (a) its use as an oxidizer (including in rocket propellants), (b) its presence in Chilean nitrate fertilizer (CNF), and (c) natural production. An analysis of the relative source strengths and how they may influence entry into the food chain has not been conducted. Averaged over the last --60 years, we estimate that the source strengths have been (a) 10.6, (b) 0.75, and (c) 0.13-0.64 Gg/y for the United States as a whole. Of this, while (b) and (c) represent actual dispersed amounts, the figure in (a) is the amount of perchlorate produced and only a fraction (f) of it has been dispersed and often in a more localized fashion. In addition, dispersal of (b) has taken place only over agricultural land. Considering that the total land area in the United States is 5.5 x the arable land area, in terms of incorporation into the food chain,the figure cited in (b) has a proportionately greater impact. Most estimates of fwill thus suggest that over the considered period, the contribution of CNF to incorporation of perchlorate in the food chain has likely been comparable to oxidizer perchlorate, with natural production being a lesser source. Fireworks presently constitute a potentially important source of increasing importance but a quantitative impact cannotyet be assessed.

Biological Availability↗

Measurement of ammonia in human breath with a liquid-film conductivity sensor.

Measurement of breath NH3 is of interest in clinical applications as it can be used as a measure of kidney/liver functions as well as halitosis. We have developed a liquid-film conductivity sensor to measure NH3 in human breath. A film of dilute H2SO4 is formed on the top of two metal capillary tubes placed in a concentric annular arrangement. The tube exterior has been specially treated to render it hydrophilic. As breath passes over the sensor tip, the film collects NH3 and the solution conductivity (measured by the concentric capillaries functioning as electrodes) decreases accordingly. This initial rate of conductivity decrease was determined to be the best metric (most rapid and least dependent on breath pCO2) for ammonia, relative to time to attain complete neutralization (conductivity minimum) or the final rate of conductivity increase as more ammonia dissolves after neutralization. The absorbing solution composition was optimized so that CO2 does not interfere. Both dynamic measurement using mask sampling and offline balloon sampling were performed. Ammonia readily absorbs on surfaces when significant concentrations of water vapor are present. As such, memory effects are common when analyzing human breath for ammonia. This problem was successfully eliminated. The results from this sensor agreed well with data obtained by a solution-phase fluorometric technique using a porous membrane diffusion scrubber and o-phthalaldehyde derivatization chemistry. For breath CO2 measurement, the applicability of a similar sensor that relies on a NaOH film was also demonstrated.

Ammonia↗

A gas-phase chemiluminescence-based analyzer for waterborne arsenic.

We show a practical sequential injection/zone fluidics-based analyzer that measures waterborne arsenic. The approach is capable of differentiating between inorganic As(III) and As(V). The principle is based on generating AsH3 from the sample in a confined chamber by borohydride reduction at controlled pH, sparging the chamber to drive the AsH3 to a small reflective cell located atop a photomultiplier tube, allowing it to react with ozone generated from ambient air, and measuring the intense chemiluminescence that results. Arsine generation and removal from solution results in isolation from the sample matrix, avoiding the pitfalls encountered in some solution-based analysis techniques. The differential determination of As(III) and As(V) is based on the different pH dependence of the reducibility of these species to AsH3. At pH < or =1, both As(III) and As(V) are quantitatively converted to arsine in the presence of NaBH4. At a pH of 4-5, only As(III) is converted to arsine. In the present form, the limit of detection (S/N = 3) is 0.05 microg/L As at pH < or =1 and 0.09 microg/L As(III) at pH approximately 4-5 for a 3-mL sample. The analyzer is intrinsically automated and requires 4 min per determination. It is also possible to determine As(III) first at pH 4.5 and then determine the remaining As in a sequential manner; this requires 6 min. There are no significant practical interferences. A new borohydride solution formulation permits month-long reagent stability.

Journal Article↗

Soap bubbles in analytical chemistry. Conductometric determination of sub-parts per million levels of sulfur dioxide with a soap bubble.

Soap bubbles provide a fascinating tool that is little used analytically. With a very low liquid volume to surface area ratio, a soap bubble can potentially provide a very useful interface for preconcentration where mass transfer to an interfacial surface is important. Here we use an automated system to create bubbles of uniform size and film thickness. We utilize purified Triton-X 100, a nonionic surfactant, to make soap bubbles. We use such bubbles as a gas-sampling interface. Incorporating hydrogen peroxide into the bubble provides a system where electrical conductance increases as the bubble is exposed to low concentrations of sulfur dioxide gas. We theoretically derive the conductance of a hollow conducting spherical thin film with spherical cap electrodes. We measure the film thickness by incorporating a dye in the bubble making solution and laser transmission photometry and find that it agrees well with the geometrically computed thickness. With the conductance of the bubble-making soap solution being measured by conventional methods, we show that the measured values of the bubble conductance with known bubble and electrode dimensions closely correspond to the theoretically computed value. Finally, we demonstrate that sub-ppm levels of SO(2) can readily be detected by the conductivity change of a hydrogen peroxide-doped soap bubble, measured in situ, when the gas flows around the bubble.

Journal Article↗

Hybrid fluorometric flow analyzer for ammonia.

We describe a robust, highly sensitive instrument for the determination of ambient ammonia. The instrument uses two syringe pumps to handle three liquids. The flow configuration is a hybrid between traditional flow injection (FI) and sequential injection (SI) schemes. This hybrid flow analyzer spends approximately 87% of its time in the continuous flow FI mode, providing the traditional FI advantages of high baseline stability and sensitivity. The SI fluid handling operation in the remaining time makes for flexibility and robustness. Atmospheric ammonia is collected in deionized water by a porous membrane diffusion scrubber at 0.2 L/min with quantitative collection efficiency, derivatized on-line to 1-sulfonatoisoindole, and measured by fluorometry. In the typical range for ambient ammonia (0-20 ppbv), response is linear (r2 = 0.9990) with a S/N = 3 limit of detection of 135 pptv (15 nM for 500 microL of injected NH4+(aq)) with an inexpensive light emitting diode photodiode-based detector. Automated operation in continuously repeated, 8-min cycles over 9 days shows excellent overall precision (n = 1544 p(NH)3 = 5 ppbv, RSD = 3%). Precision for liquid-phase injections is even better (n = 1520, [NH4+(aq)] = 2.5 microM, RSD = 2%). The response decreases by 3.6% from 20 to 80% relative humidity.

Ammonia↗

Versatile gas/particle ion chromatograph.

A new, compact gas/particle ion chromatograph has been developed for measuring ionic constituents in PM2.5 (particulate matter of aerodynamic diameter < or = 2.5 microm) and water-soluble ionogenic gases. The instrument has separate sampling channels for gases and particles. In one, a membrane denuder collects soluble gases for preconcentration and analysis. In the other, a cyclone removes larger particles, a membrane denuder removes soluble gases, and a continuously wetted hydrophilic filter collects particles. A single, multiport, syringe pump handles liquid transport, and one conductivity detector measures anions and ammonium for both channels. Electrodialytically generated gradient hydroxide eluent permits 20 min chromatographic runs. Gas/particle samples are each collected for 40 min, butthe sampling intervals are staggered by 20 min. Liquid samples from the gas denuder and particle collector are aspirated and preconcentrated on sequential cation and anion concentrators and transferred respectively to an ammonia transfer device and an anion separation column. The flow configuration results in an ammonium peak before anion peaks in the chromatogram. The system measures ammonia, organic acids (such as acetic, formic, and oxalic acids), HCl, HONO, SO2, HNO3, and the corresponding ions in the aerosol phase. Low ng/m3 to sub-ng/m3 limits of detection (LODs) are attained for most common gases and particulate constituents, the LODs for gaseous SO2 to NH3 range, for example, from sub parts per trillion by volume (sub-pptv) to approximately 5 pptv.

Aerosols↗

Continuous collection of soluble atmospheric particles with a wetted hydrophilic filter.

Approximately one-third of the area (14-mm diameter of a 25-mm diameter) of a 5-microm uniform pore size polycarbonate filter is continuously wetted by a 0.25 mL/min water mist. The water forms a continuous thin film on the filter and percolates through it. The flowing water substantially reduces the effective pore size of the filter. At the operational air sampling flow rate of 1.5 standard liters per minute, such a particle collector (PC) efficiently captures particles down to very small size. As determined by fluorescein-tagged NaCl aerosol generated by a vibrating orifice aerosol generator, the capture efficiency was 97.7+% for particle aerodynamic diameters ranging from 0.28 to 3.88 microm. Further, 55.3 and 80.3% of 25- and 100-nm (NH4)2SO4 particles generated by size classification with a differential mobility analyzer were respectively collected by the device. The PC is integrally coupled with a liquid collection reservoir. The liquid effluent from the wetted filter collector, bearing the soluble components of the aerosol, can be continuously collected or periodically withdrawn. The latter strategy permits the use of a robust syringe pump for the purpose. Coupled with a PM2.5 cyclone inlet and a membrane-based parallel plate denuder at the front end and an ion chromatograph at the back end, the PC readily operated for at least 4-week periods without filter replacement or any other maintenance.

Journal Article↗

Speciation-capable field instrument for the measurement of arsenite and arsenate in water.

Hydride generation to form arsine and in-line preconcentration of the arsine into an alkaline KMnO4 receiver followed by molybdenum blue (MB) colorimetric determination of the arsenate formed is proposed for the highly sensitive and separate measurement of total inorganic As and As(III). Reduction of As to AsH3 is carried out by NaBH4; when the reduction is carried out at pH 1, all the inorganic As is reduced to AsH3, and when carried out at pH 7, only As(III) is reduced. Reductions at the two different pH levels are carried out in two different arsine generators simultaneously using constant addition of NaBH4 with solenoid pumps. The AsH3 is collected by individual porous membrane diffusion scrubbers filled with a stationary solution of KMnO4, and the contents of the two scrubbers sequentially enter a flow analysis stream. MB is formed by merging with a ammonium molybdate-ascorbic acid reagent, passing through a heated reactor, and is then measured by a LED/photodiode-based absorbance detector. Robustness was confirmed for total As using three types of certified natural water samples. Speciation analysis data from well water samples analyzed by this method agree well with HPLC-ICPMS measurements in a different laboratory. The system has been successfully applied to field measurements of As(III) and As(V), where levels were significantly below 1 mug/L. For a 20-mL sample, the limits of detection (LODs) for this inexpensive instrument are 0.3 microg/L for both As(III) and total As. When an 80-mL sample is analyzed, LODs are 0.07 microg/L As(III) and 0.09 microg/L total As. The general approach should be applicable to many other analyte species of interest that can be isolated from the matrix by the formation of a suitable volatile compound that can be recaptured.

Journal Article↗

Gas-phase ion association provides increased selectivity and sensitivity for measuring perchlorate by mass spectrometry.

Perchlorate (ClO4-) competitively inhibits the uptake of iodide by the thyroid gland. Trace quantities of perchlorate are being increasingly detected in food and environmental samples. There is great concern that perchlorate contamination may be far more widespread than believed until now. Increasingly sensitive and unambiguous methods are needed for measuring perchlorate. We report here an ion chromatography-ion association-electrospray ionization-mass spectrometry (IC/IA-ESI-MS) method of substantially greater selectivity and sensitivity than other available single-stage MS approaches. A long chain dipositive cationic agent (D2+) is added postcolumn in low concentration. This ion associates with perchlorate, even in the gas phase. Perchlorate is, thus, detected as DClO4+ in the positive ion mode at an m/z value between 300 and 400 (depending on the choice of D2+). This results in much better S/N and selectivity, as compared to detecting 35ClO4- at m/z 99, where H34SO4- also responds. We show results for various dicationic agents which vary in their selectivity and affinity for ClO4-, typically being at least 1 order of magnitude more selective for ClO4- over HSO4-. For a 100-microL injected standard, limits of detection (LOD, S/N = 3) are as good as 25 ng/L on a single quadrupole mass spectrometer. Calibration for concentrations up to 100 microg/L displays an r2 value of > or =0.9993. We show applicability to various real samples. A number of the studied reagents are suitable for such applications.

Journal Article↗

Summertime ambient formaldehyde in five U.S. metropolitan areas: Nashville, Atlanta, Houston, Philadelphia, and Tampa.

First, we briefly review the atmospheric chemistry and previous intercomparison measurements for HCHO, with special reference to the diffusion scrubber Hantzsch reaction based fluorescence instrument used in the field studies reported herein. Then we discuss summertime HCHO levels in five major U.S. cities measured over 1999-2002, primarily from ground-based measurements. Land-sea breeze circulations play a major role in observed concentrations in coastal cities. Very high HCHO peak mixing ratios were observed in Houston (>47 ppb) where the overall median mixing ratio was 3.3 ppb; the corresponding values in Atlanta were approximately >18 and 7.9 ppb, respectively. The peak and median mixing ratios (9.3 and 2.3 ppb) were the lowest for Tampa, where the land-sea breeze also played an important role. In several cities, replicate HCHO measurements were made by direct spectroscopic instruments; the instruments were located kilometers from each other and addressed very different heights (e.g., 106 vs 10 m). Even under these conditions, there was remarkable qualitative and often quantitative agreement between the different instruments, when they were all sampling the same air mass within a short period of each other. Local chemistry dominates how HCHO is formed and dissipated. The high concentrations in Houston resulted from emissions near the ship channel; the same formaldehyde plume was measured at two sites and clearly ranged over tens of kilometers. Local micrometeorology is another factor. HCHO patterns measured at a high-rise site in downtown Nashville were very much in synchrony with other ground sites 12 km away until July 4 celebrations whence HCHO concentrations at the downtown site remained elevated for several days and nights. The formation and dissipation of HCHO in the different cities are discussed in terms of other concurrently measured species and meteorological vectors. The vertical profiles of HCHO in and around Tampa under several different atmospheric conditions are presented. The extensive data set represented in this paper underscores that urban HCHO measurements can now be made easily; the agreement between disparate instruments (that are independently calibrated or rely on the absolute absorption cross section) further indicates that such measurements can be done reliably and accurately for this very important atmospheric species. The data set presented here can be used as a benchmark for future measurements if the use of formaldehyde precursors such as methanol or methyl tert-butyl ether (MTBE) as oxygenated fuel additives increases in the future.

Air Pollutants↗

Perchlorate and iodide in dairy and breast milk.

Perchlorate inhibits iodide uptake and may impair thyroid and neurodevelopment in infants. Recently, we unambiguously identified the presence of perchlorate in all seven brands of dairy milk randomly purchased from grocery stores in Lubbock, TX. How widespread is perchlorate in milk? Perchlorate in 47 dairy milk samples from 11 states and in 36 human milk samples from 18 states were measured. Iodide was also measured in a number of the samples. Perchlorate was detectable in 81 of 82 samples. The dairy and breast milk means were, respectively, 2.0 and 10.5 microg/L with the corresponding maximum values of 11 and 92 microg/L. Perchlorate is present in virtually all milk samples, the average concentration in breast milk is five times higher than in dairy milk. Although the number of available measurements are few at this point, for breast milk samples with a perchlorate content greater than 10 microg/L, the iodide content is linearly correlated with the inverse of the perchlorate concentration with a r2 of >0.9 (n = 6). The presence of perchlorate in the milk lowers the iodide content and may impair thyroid development in infants. On the basis of limited available data, iodide levels in breast milk may be significantly lower than it was two decades ago. Recommended iodine intake by pregnant and lactating women may need to be revised upward.

Animals↗

The origin of naturally occurring perchlorate: the role of atmospheric processes.

Perchlorate, an iodide uptake inhibitor, is increasingly being detected in new places and new matrices. Perchlorate contamination has been attributed largelyto the manufacture and use of ammonium perchlorate (the oxidizer in solid fuel rockets) and/or the earlier use of Chilean nitrate as fertilizer (approximately 0.1% perchlorate). However, there are regions such as the southern high plains (Texas Panhandle) where there is no clear historical or current evidence of the extensive presence of rocket fuel or Chilean fertilizer sources. The occurrence of easily measurable concentrations of perchlorate in such places is difficult to understand. In the southern high plains groundwater, perchlorate is better correlated with iodate, known to be of atmospheric origin, compared to any other species. We show that perchlorate is readily formed by a variety of simulated atmospheric processes. For example, it is formed from chloride aerosol by electrical discharge and by exposing aqueous chloride to high concentrations of ozone. We report that perchlorate is present in many rain and snow samples. This strongly suggests that some perchlorate is formed in the atmosphere and a natural perchlorate background of atmospheric origin should exist.

Atmosphere↗

Asymmetric membrane fiber-based carbon dioxide removal devices for ion chromatography.

The application of hollow and filament-filled single asymmetric membrane fibers, consisting of a thin silicone layer on a tubular microporous support, for removing CO(2) in suppressed ion chromatography effluents is described. With appropriate choice of the removal device and operating conditions, the CO(2) can be essentially quantitatively (99+%) removed. For carbonate-based eluents, the use of such devices greatly reduces or eliminates the water dip, permitting better quantitation of poorly retained anions that elute close to the dip, allows practical gradient chromatography, and improves noise levels and attainable detection limits. In hydroxide eluent chromatography, the device largely removes the response from CO(2) present in the samples; this greatly aids atmospheric trace gas analysis by IC. Device dimensions are such that the dispersion introduced by the device is small.

Journal Article↗

Durable microfabricated high-speed humidity sensors.

We describe a durable microfabricated humidity sensor made of interdigitated rhodium electrodes on a silicon substrate covered with a sensing film of Nafion perfluorosulfonate ionomer. Rhodium electrodes are much less prone to oxidative degradation compared to previously described gold electrode-based sensors. Even with dc excitation, Rh electrode sensors exhibit excellent long-term response stability. It has been found that low-amplitude (+/-1 V) square wave excitation can prolong the usability of gold electrode-based sensors to at least several months; however, this mode of interrogation cannot provide subsecond response times. Rhodium deposition on the microsensors is much more difficult than that of gold. We were able to attain crack-free Rh deposits by adaptation of pulsed electroplating techniques. At excitation voltages of >2 V dc, the Rh sensors respond to moisture with 10 <--> 90% rise and fall times of 30-50 ms. These are the fastest microfabricated water vapor sensors reported to date. We demonstrate applications as a breath monitor. Such sensors should also be of utility in atmospheric eddy measurements. Short-term repeatability is better than 0.6% RSD (n = 7).

Biosensing Techniques↗

Field instrument for simultaneous large dynamic range measurement of atmospheric hydrogen sulfide, methanethiol, and sulfur dioxide.

We describe a membrane-based collection/analysis system that differentially monitors H2S and CH3SH, and to which a conductometric SO2 analyzer using the same collector was coupled. A diffusion scrubber (DS) comprised of a Nafion tube collects H2S selectively while a porous polytetrafluoroethylene (pPTFE) DS collects both H2S and CH3SH. Both gases are measured via their ability to react with fluorescein mercuric acetate (FMA) which results in decreased fluorescence. The limited dynamic range of a negative signal procedure was overcome by using dual DS units comprised of short and long scrubbers, placed serially in the liquid flow line. Different DS designs and membrane materials were investigated. H2S, CH3SH, and SO2 from a biogenic point source were continuously measured, and the H2S/CH3SH data compared well with a standard procedure involving Tedlar bag collection, preconcentration and thermal desorption from a Tenax trap, and measurement by gas chromatography/flame photometric detection. Walkaround portability of the instrument and very large dynamic range measurement of H2S and SO2 were demonstrated around the Mt. Aso volcano.

Air Pollutants↗

Membrane-based parallel plate denuder for the collection and removal of soluble atmospheric gases.

A continuously wetted cellulose acetate membrane-based parallel plate diffusion denuder is described. This is the first membrane-based denuder that has a small enough internal liquid holdup volume to permit reasonably rapid response time (10 --> 90% rise time of approximately 1.2 min for a transient event at a liquid flow rate of 500 microL/min) while permitting quantitative removal of common soluble atmospheric trace gases at flow rates up to 1.7 L/min. The latter attribute permits the use of the device as the first element in a particle sampling and analysis system for the quantitative removal of potentially interfering soluble trace gases. Particle losses in the denuder range from 0.9 to 2.9% over an aerodynamic diameter range of 0.38-3.48 microm, averaging 1.8%. However, only approximately 0.5% of the particles actually appears in the denuder effluent liquid. The relatively compact (300 mm H x 57 mm W x 26 mm D) wet denuder should be attractive in a number of applications. We show excellent agreement for HONO measurements with a conventional larger parallel plate wetted denuder in field measurements.

Journal Article↗

Capillary ion chromatography.

This review summarizes progress in capillary ion chromatography. Theoretical aspects and practical limitations of packed and open tubular capillary columns are considered. Applications of packed and open tubular capillary IC are described. Emerging technologies such chip-scale IC and the use of monolithic columns are discussed.

Journal Article↗