PubMed Health⌕ Search

Biomedical subjects

Q H Zhao

Publications and source records attributed to Q H Zhao.

9 recordsLinked to original sources

Influence of affinity and antigen density on antibody localization in a modifiable tumor targeting model.

A persistent question in the field of antibody imaging and therapy is whether increased affinity is advantageous for the targeting of tumors. We have addressed this issue by using a manipulatable model system to investigate the impact of affinity and antigen density on antibody localization. In vitro enzyme-linked immunosorbent assays and bead-binding assays were carried out using BSA conjugated with high and low densities (HD and LD, respectively) of the chemical hapten rho-azophenyl-arsonate as an antigen. Isotype-matched monoclonal antibodies (mAbs) 36-65 and 36-71, with identical epitope specificity but 200-fold differences in affinity, were chosen as targeting agents. The relative in vitro binding of 36-65 and 36-71 was compared with an artificial "tumor" model in vivo using antigen-substituted beads s.c. implanted into SCID mice. Nonsubstituted BSA beads were implanted in the contralateral groin as a nonspecific control. The efficacy of the targeting of [125I]-labeled antibodies was assessed by the imaging of animals on a gamma-scintillation camera using quantitative region-of-interest image analysis over the course of 2 weeks and by postmortem tissue counting. In vitro, both antibodies bound well to the HD antigen, whereas only the high-affinity mAb 36-71 bound effectively to the LD antigen. In vivo, high-affinity mAb 36-71 bound appreciably to both LD and HD beads. In contrast, there was no specific localization of low-affinity mAb 36-65 to LD antigen beads, although the antibody did bind to the beads with the HD antigen. Whereas the high-affinity mAb 36-71 increased its binding to HD beads throughout the 14 days of observation, binding of the high affinity antibody to LD beads and of the low affinity antibody to HD beads plateaued between 10-14 days. These in vitro and in vivo findings demonstrate that the need for a high-affinity antibody is dependent on the density of the target antigen. High-affinity antibodies bind effectively even with a single antigen-Fab interaction, irrespective of the antigen density. In contrast, low-affinity antibodies, because of weak individual antigen-Fab interactions, require the avidity conferred by divalent binding for effective attachment, which can only occur if antigen density is above a certain threshold. An understanding of the differential behavior of high- and low-affinity antibodies and the impact of avidity is useful in predicting the binding of monovalent antibody fragments and engineered antibody constructs and underlies the trend toward development of multivalent immunological moieties. Consideration of the relative density of the antigen on the tumor and the background tissues may enable and even favor targeting with low-affinity antibodies in selected situations.

Animals↗

The mammary gland iodide transporter is expressed during lactation and in breast cancer.

The sodium/iodide symporter mediates active iodide transport in both healthy and cancerous thyroid tissue. By exploiting this activity, radioiodide has been used for decades with considerable success in the detection and treatment of thyroid cancer. Here we show that a specialized form of the sodium/iodide symporter in the mammary gland mediates active iodide transport in healthy lactating (but not in nonlactating) mammary gland and in mammary tumors. In addition to characterizing the hormonal regulation of the mammary gland sodium/iodide symporter, we demonstrate by scintigraphy that mammary adenocarcinomas in transgenic mice bearing Ras or Neu oncogenes actively accumulate iodide by this symporter in vivo. Moreover, more than 80% of the human breast cancer samples we analyzed by immunohistochemistry expressed the symporter, compared with none of the normal (nonlactating) samples from reductive mammoplasties. These results indicate that the mammary gland sodium/iodide symporter may be an essential breast cancer marker and that radioiodide should be studied as a possible option in the diagnosis and treatment of breast cancer.

Amino Acid Sequence↗

Remotely pollable Geiger-Müller detector for continuous monitoring of iodine-131 therapy patients.

UNLABELLED: In many countries, patients treated with therapeutic amounts of (131)I are hospitalized because of radiation safety considerations. To determine when they can return home, radiation levels are intermittently monitored at bedside using a handheld Geiger-MIller (GM) counter, although this procedure can be cumbersome and inexact. METHODS: We have developed and tested a remotely pollable system for continuous radiation monitoring of (131)I therapy inpatients, using readily available hardware and standard telephone lines. The remote detector system, consisting of a palmtop IBM-compatible personal computer, specialized software, PCMCIA modem and miniature serial port-based GM detector, is placed opposite the patient's bed at a fixed distance, and continuous 1-min acquisitions are started. Initially and at least twice daily, the remote palmtop is contacted by modem, and all interval data are uploaded onto the operator's base computer over the telephone line, including measurements taken with the patient in a predetermined standardized position. Continuous minute-to-minute data may be viewed in native form or can be imported into graphing and spreadsheet programs. Points acquired with the patient in standardized position are specially marked to highlight the constant geometry used. The ratio of initial counting rate to administered dose is used to estimate residual (131)I body burden by proportionality. Display of data as a semilogarithmic plot facilitates extrapolation of the activity curves and prediction of the patient's earliest time of discharge. RESULTS: We have characterized the remote GM detector system to confirm accuracy, counting rate linearity and reliability of data transfer. We describe examples that illustrate the applicability and usefulness of this method for remote monitoring of inpatient (131)I therapy levels. CONCLUSION: Monitoring patients with the described remotely pollable GM detector is an accurate and easy-to-implement technique that could conceivably lead to shortened hospital stays for (131)I therapy inpatients. Continuous quantitative data obtained are useful for kinetic and dosimetric analyses, which may be applied to study other gamma-emitting radiopharmaceuticals as well. The flexibility of the technique may permit its use in the monitoring of therapy on an outpatient basis, where allowed.

Equipment Design↗

[Role of afferent renal nerves in 2K2C Goldblatt hypertension].

In order to study the role of afferent renal nerves in 2K2C Goldblatt hypertension, the renal afferent nerves were selectively lesioned by bilateral T9-L2 spinal dorsal rhizotomy before clipping (internal diameter, 0.3 mm) of birenal arteries. Systolic blood pressure of the rat was measured by tail-cuff method. Concentrations of catecholamines, Ang II, and aldosterone were determined respectively by HPLC-EC and RIA, and vascular structural changes were measured by blood vessel micro-image analysis system coupled with a computer. The results showed that the concentrations of NE and E in medulla oblongata, adrenal gland and plasma, and of plasma Ang II and aldosterone as well as body weight of the rat were all significantly increased. The heart coefficient (heart wt/body wt), the media thickness, and the media thickness/lumen diameter in superior mesenteric arteries were also increased in 2K2C hypertensive rats (clipping, 6 wk) as compared with those in control rats. Bilateral rhizotomy delayed development of 2K2C hypertension and prevented above-mentioned vascular structural changes, the NE and E concentrations of medulla oblongata, adrenal gland and plasma were all decreased, hypothalamic NE and E were increased, and plasma Ang II level was not significantly changed. These results suggest that afferent renal nerves may play a partial role in the development of hypertension in 2K2C rats by activating sympathetic nervous system as a result of affecting metabolic activities of brain catecholaminergic neurons, and that high-plasma Ang II and aldosterone as well as heart hypertrophy and proliferation of vascular smooth muscle cells may also participate in the pathogenesis of hypertension in 2K2C rats.

Afferent Pathways↗

Theoretical analysis of in vivo macrophage adhesion and foreign body giant cell formation on polydimethylsiloxane, low density polyethylene, and polyetherurethanes.

Quantitative description of foreign body giant cell (FBGC) formation on implanted polymer surfaces as a function of time can conceivably correlate cell adhesion with polymer properties and possibly predict the behavior of the polymer in vivo. In the present study, the formation of FBGCs on various biomedical polymers was quantified by two parameters: the density of adherent macrophages present initially that participate in FBGC formation (d0) and the rate constant for cell fusion (k); both kinetic parameters were used to calculate the time-dependent FBGC density (dfc). The materials used were: three Pellethane poly(etherurethanes) (PEUs) varying in weight percent of hard segment, one poly(etherurethane urea) (PEUU), and NHLBI-DTB primary reference materials: low density polyethylene (LDPE), silica-free polydimethylsiloxane (PDMS). The results indicated that up to 5 weeks of implantation, FBGCs were formed from the fusion of one population of adherent macrophages present by 3 days post-implantation. Furthermore, only a small fraction (< 8%) of this initial adherent macrophage population participated in FBGC formation. Based on the results of previous studies and the current study, it was concluded that increase in PEU hard segment weight percent, surface hardness and hydrophobicity increased total protein adsorption and effectively increased d0 and dfc. No further correlations between the material properties of all polymers and the cell kinetics can be made at this time. However, this study demonstrated that macrophage adhesion and FBGC formation can be quantified with the cell fusion model, and are modulated by various polymer properties.

Adsorption↗

Human plasma alpha 2-macroglobulin promotes in vitro oxidative stress cracking of Pellethane 2363-80A: in vivo and in vitro correlations.

It is hypothesized in this study that the phenomenon of environmental stress cracking (ESC) in polyetherurethane is caused by a synergistic action of biological components in the body fluids, oxidative agents, and stress. An in vitro system is designed to mimic the in vivo system; human plasma contains certain biological components that can act as a stress cracking promoter, while H2O2 (Co) solution provides an oxidative reaction comparable to that observed in the respiratory burst of adherent macrophages and foreign-body giant cells. It is demonstrated that the phenomenon of in vivo stress cracking in Pellethane 2363-80A is duplicated by an in vitro system that involves a pretreatment of prestressed specimens with human plasma at 37 degrees C for 7 days followed by oxidation in 10% hydrogen peroxide with 0.10M cobalt chloride at 50 degrees C for 10 days. The pretreatment with plasma has a synergistic effect with the oxidation by H2O2 (Co) treatment to produce ESC. A plasma component responsible for promoting stress cracking in Pellethane polyurethane is identified to be alpha 2-macroglobulin (alpha 2M).

Animals↗

Biotolerance of a semisolid hydrophobic biodegradable poly(ortho ester) for controlled drug delivery.

We evaluated the biotolerance of a new semisolid poly(ortho ester) (POE) intended for controlled drug delivery. Two different investigations were carried out in rats: subcutaneous injections and the cage-implant system. Sodium hyaluronate (SH), 1%, in phosphate buffer was used as a noninflammatory control. When injected subcutaneously in rats, the POE induced a mild and local inflammation at 3 and 7 days followed by a minimal chronic inflammation at 14 and 21 days. When using the cage-implant system, we quantified the inflammatory components of the exudate surrounding the implanted material within the cage system at 3, 7, 14, and 21 days. The total leukocyte and macrophage concentrations were higher only at 7 days for both SH and POE compared to the control (empty cage). The other parameters were not significantly different from the control. These results show that POE is well-tolerated by rats when used subcutaneously.

Animals↗

Radionuclide bone scanning in routine clinical practice.

Bone scintigraphy (scanning) is a quick and cost-effective method for evaluating potential bone lesions not visualized on plain radiography. Uses include evaluation of primary and metastatic bone tumors, treatment of bone pain due to tumor invasion, detection of occult fractures and stress injury, evaluation of postprosthesis joint pain, evaluation of metabolic bone disorders, and diagnosis of osteomyelitis. The main advantage of bone scanning is the ability to evaluate the entire skeleton rapidly with high sensitivity.

Bone Diseases↗