PubMed Health⌕ Search

Biomedical subjects

Q J Fu

Publications and source records attributed to Q J Fu.

18 recordsLinked to original sources

Birefringence effect as a tool for astrophysical plasma study.

Group delay between two magnetoionic modes is discovered and spectrally confirmed ( deltat(g) proportional, variantf(-3)) for the first time for quasiperiodic narrow band millisecond solar radio pulsations. Analysis of cross delays and autodelays proves that both X and O modes originate at the same source, so the radiation is weakly polarized originally. This finding allows one to specify the emission mechanism of the pulsations to be a nonlinear plasma mechanism operating at the second harmonics. Physical parameters of the solar corona are determined by the use of the theory of the nonlinear plasma mechanism; they agree well with independent observations of solar millisecond pulsations.

Journal Article↗

Recognition of time-distorted sentences by normal-hearing and cochlear-implant listeners.

This study evaluated the effects of time compression and expansion on sentence recognition by normal-hearing (NH) listeners and cochlear-implant (CI) recipients of the Nucleus-22 device. Sentence recognition was measured in five CI users using custom 4-channel continuous interleaved sampler (CIS) processors and five NH listeners using either 4-channel or 32-channel noise-band processors. For NH listeners, recognition was largely unaffected by time expansion, regardless of spectral resolution. However, recognition of time-compressed speech varied significantly with spectral resolution. When fine spectral resolution (32 channels) was available, speech recognition was unaffected even when the duration of sentences was shortened to 40% of their original length (equivalent to a mean duration of 40 ms/phoneme). However, a mean duration of 60 ms/phoneme was required to achieve the same level of recognition when only coarse spectral resolution (4 channels) was available. Recognition patterns were highly variable across CI listeners. The best CI listener performed as well as NH subjects listening to corresponding spectral conditions; however, three out of five CI listeners performed significantly poorer in recognizing time-compressed speech. Further investigation revealed that these three poorer-performing CI users also had more difficulty with simple temporal gap-detection tasks. The results indicate that limited spectral resolution reduces the ability to recognize time-compressed speech. Some CI listeners have more difficulty with time-compressed speech, as produced by rapid speakers, because of reduced spectral resolution and deficits in auditory temporal processing.

Adult↗

Recognition of spectrally asynchronous speech by normal-hearing listeners and Nucleus-22 cochlear implant users.

This experiment examined the effects of spectral resolution and fine spectral structure on recognition of spectrally asynchronous sentences by normal-hearing and cochlear implant listeners. Sentence recognition was measured in six normal-hearing subjects listening to either full-spectrum or noise-band processors and five Nucleus-22 cochlear implant listeners fitted with 4-channel continuous interleaved sampling (CIS) processors. For the full-spectrum processor, the speech signals were divided into either 4 or 16 channels. For the noise-band processor, after band-pass filtering into 4 or 16 channels, the envelope of each channel was extracted and used to modulate noise of the same bandwidth as the analysis band, thus eliminating the fine spectral structure available in the full-spectrum processor. For the 4-channel CIS processor, the amplitude envelopes extracted from four bands were transformed to electric currents by a power function and the resulting electric currents were used to modulate pulse trains delivered to four electrode pairs. For all processors, the output of each channel was time-shifted relative to other channels, varying the channel delay across channels from 0 to 240 ms (in 40-ms steps). Within each delay condition, all channels were desynchronized such that the cross-channel delays between adjacent channels were maximized, thereby avoiding local pockets of channel synchrony. Results show no significant difference between the 4- and 16-channel full-spectrum speech processor for normal-hearing listeners. Recognition scores dropped significantly only when the maximum delay reached 200 ms for the 4-channel processor and 240 ms for the 16-channel processor. When fine spectral structures were removed in the noise-band processor, sentence recognition dropped significantly when the maximum delay was 160 ms for the 16-channel noise-band processor and 40 ms for the 4-channel noise-band processor. There was no significant difference between implant listeners using the 4-channel CIS processor and normal-hearing listeners using the 4-channel noise-band processor. The results imply that when fine spectral structures are not available, as in the implant listener's case, increased spectral resolution is important for overcoming cross-channel asynchrony in speech signals.

Adult↗

[Effects of Bay K8644 and nifedipine on L-type Ca2+ channels in hypothalamic neurons of rats].

To investigate the effects of Bay K8644 and nifedipine on L-type of Ca2+ channels in hypothalamic neurons, the cell-attached patch-clamp technique was used to record Ca2+ current from isolated neurons. The results showed that the averaged open time and NPo were markedly increased by Bay K8644, but had no effect on channel conductance. Nifedipine, on the contrary, had an inhibitory effect on the L-type Ca2+ channels.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Human hearing enhanced by noise.

Noise was traditionally regarded as a nuisance, which should be minimized if possible. However, recent research has shown that addition of an appropriate amount of noise can actually improve signal detection in a nonlinear system, an effect called stochastic resonance. While stochastic resonance has been described in a variety of physical and biological systems, its functional significance in human sensory systems remains mostly unexplored. Here we report psychophysical data showing that signal detection and discrimination can be enhanced by noise in human subjects whose hearing is evoked by either normal acoustic stimulation or electric stimulation of the auditory nerve or the brainstem. Our results suggest that noise is an integral part of the normal sensory process and should be added to auditory prostheses.

Adult↗

Effects of dynamic range and amplitude mapping on phoneme recognition in Nucleus-22 cochlear implant users.

OBJECTIVE: To determine the consequences for phoneme recognition of errors in setting threshold and loudness levels in cochlear implant listeners using a 4-channel continuous interleaved sampling (CIS) speech processor. DESIGN: Three Nucleus-22 cochlear implant listeners, who normally used the SPEAK speech processing strategy participated in this study. An experimental 4-channel CIS speech processor was implemented in each listener as follows. Speech signals were band-pass filtered into four broad frequency bands and the temporal envelope of the signal in each band was extracted by half-wave rectification and low-pass filtering. A power function was used to convert the extracted acoustic amplitudes to electric currents. The electric currents were dependent on the exponent of the mapping power function and the electrode dynamic range, which was determined by the minimum and maximum stimulation levels. In the baseline condition, the minimum and maximum stimulation levels were defined as the psychophysically measured threshold level (T-level) and maximum comfortable level (C-level). In the experimental conditions, the maximum stimulation levels were fixed at the C-level and the dynamic range (in dB) was changed by varying the minimum stimulation levels on all electrodes. This manipulation simulates the effect of an erroneous measurement of the T-level. Phoneme recognition was obtained as the dynamic range of electrodes was changed from 1 dB to 20 dB and as the exponent of the power-law amplitude mapping function was changed from 0.1 to 0.4. RESULTS: For each mapping condition, the electric dynamic range had a significant, but weak effect on vowel and consonant recognition. For a strong compression (p = 0.1), best vowel and consonant scores were obtained with a large dynamic range (12 dB). When the exponent of the mapping function was changed to 0.2 and 0.4, the dynamic range producing the highest scores decreased to 6 dB and 3 dB, respectively. CONCLUSIONS: Phoneme recognition with a 4-channel CIS strategy was only mildly affected by large changes in both electric threshold and loudness mapping. Errors in threshold by a factor of 2 (6 dB) and in the loudness mapping exponent by a factor of 2 were required to produce a significant decrease in performance. In these extreme conditions, the effect of the electric dynamic range on phoneme recognition could be due to two independent factors: abnormal loudness growth and a reduction in the number of discriminable intensity steps. The decrease in performance caused by a reduced electric dynamic range can be compensated by a more expansive power-law mapping function, as long as the number of discriminable intensity steps is moderately large (e.g., >8).

Acoustic Stimulation↗

Effect of stimulation rate on phoneme recognition by nucleus-22 cochlear implant listeners.

This study investigated the effect of pulsatile stimulation rate on medial vowel and consonant recognition in cochlear implant listeners. Experiment 1 measured phoneme recognition as a function of stimulation rate in six Nucleus-22 cochlear implant listeners using an experimental four-channel continuous interleaved sampler (CIS) speech processing strategy. Results showed that all stimulation rates from 150 to 500 pulses/s/electrode produced equally good performance, while stimulation rates lower than 150 pulses/s/electrode produced significantly poorer performance. Experiment 2 measured phoneme recognition by implant listeners and normal-hearing listeners as a function of the low-pass cutoff frequency for envelope information. Results from both acoustic and electric hearing showed no significant difference in performance for all cutoff frequencies higher than 20 Hz. Both vowel and consonant scores dropped significantly when the cutoff frequency was reduced from 20 Hz to 2 Hz. The results of these two experiments suggest that temporal envelope information can be conveyed by relatively low stimulation rates. The pattern of results for both electrical and acoustic hearing is consistent with a simple model of temporal integration with an equivalent rectangular duration (ERD) of the temporal integrator of about 7 ms.

Adult↗

Effects of phase duration and electrode separation on loudness growth in cochlear implant listeners.

Loudness estimates were obtained in a group of four adult subjects implanted with the Nucleus-22 multielectrode cochlear implant device, for a range of pulse amplitudes and different fixed phase durations and electrode separations. The stimulus was a 200-ms long train of biphasic pulses presented at 500 pulses/s. Subjects estimated loudness as a number from 0 ("don't hear it") to 100 ("uncomfortably loud"). Loudness was found to grow exponentially with pulse amplitude, at a rate that was dependent upon the phase duration as well as the electrode separation. An equation of the form L = e(lambda + gamma M)(D theta)I, where L is the estimated loudness, M is the separation between electrodes of a stimulating pair, D is the phase duration, I is current amplitude, and lambda, gamma, and theta are constants, appears to describe the observed data adequately. The findings are remarkably consistent across subjects.

Adult↗

Effects of electrode location and spacing on phoneme recognition with the Nucleus-22 cochlear implant.

OBJECTIVE: The objective of this paper was to determine how phoneme identification was affected by the cochlear location and spacing of the electrodes in cochlear implant listeners. DESIGN: Subjects were initially programmed with the full complement of 20 active electrodes, in which each electrode was assigned to represent the output of one filter in the normal SPEAK processor. In the present study several four-electrode processors were constructed by assigning the output of more than one filter to a single electrode. In all conditions speech sounds were still analyzed into 20 frequency bands and processed according to the usual SPEAK processing strategy, but the location and spacing of the four stimulated electrode pairs were varied systematically. In Experiment I, the spacing between stimulated electrodes was fixed at 3.75 mm and the cochlear location of the four electrode pairs was shifted from the most-apical position up to 3.0 mm toward the base in 0.75 mm steps. In Experiment II, the spatial separation between the four electrode pairs (each bipolar-plus-one) was systematically changed from 1.5 mm to 4.5 mm while holding the most apical active electrode fixed. In Experiment III, the spacing of active electrodes was varied to represent equal tonotopic spacing to equal linear frequency intervals between pairs. Recognition of medial vowels and consonants was measured in three subjects with these custom four-electrode speech processors. RESULTS: In Experiment I, results showed that both vowel and consonant recognition were best when the electrodes were in the most apical locations. In Experiment II, best speech recognition occurred when electrode pairs were separated by 3 to 3.75 mm. In Experiment III, both vowel and consonant recognition scores decreased when the spacing of electrode pairs was changed from equal tonotopic spacing to equal linear frequency intervals. Overall, vowel and consonant recognition were best at the most apical electrode locations and when the spacing of electrodes matched the frequency intervals of the analysis filters. Consonant recognition was relatively robust to alterations in electrode location and spacing. The best vowel scores with four-electrode speech processors were about 10 percentage lower than scores obtained with the full 20-electrode speech processors. However, the best consonant scores with four-electrode speech processors were similar to those obtained with the full 20-electrode speech processors. Information transmission analysis revealed that temporal envelope cues (voicing and manner) were not strongly affected by changes in electrode location and spacing, whereas spectral cues, as represented by vowel recognition and consonantal place of articulation, were strongly affected. Both spectral and temporal phoneme cues were strongly affected by the degree of tonotopic warping, created by altering both the location and spacing of the activated electrodes. CONCLUSION: The cochlear location and spacing of the activated electrodes had a clear effect on phoneme recognition. Temporal cues were less affected by tonotopic shifts or linear tonotopic stretching or shrinking, but were susceptible to nonlinear tonotopic warping. Spectral cues were sensitive to all tonotopic manipulations: shifting, linear stretching, and nonlinear warping. However, the present experiments could not differentiate whether the optimal mapping between analysis frequency bands and stimulation electrodes was determined by the normal acoustic tonotopic pattern or by the pattern learned from experience with the 20-electrode implant.

Adult↗

Effects of electrode configuration and frequency allocation on vowel recognition with the Nucleus-22 cochlear implant.

OBJECTIVE: This study was conducted to understand vowel recognition in cochlear implants as a function of the cochlear location and separation of the stimulated electrode pairs and as a function of the matching between speech spectral information and the location of the stimulated electrodes. DESIGN: Four-electrode speech processors with a continuous interleaved sampling speech processing strategy were implemented through a custom interface in five subjects implanted with the Nucleus-22 cochlear implant. The temporal envelopes from four broad frequency bands were used to modulate 500 pps, 100 microsec/phase interleaved pulse trains delivered to four electrode pairs. Ten different frequency allocations and five sets of four-electrode configurations were tested. Each frequency allocation represented the same cochlear extent but different cochlear locations based on Greenwood's frequency-to-place formula. Recognition of multi-talker medial vowels was measured for each combination of parameters with no period of practice or adjustment. RESULTS: Results showed that recognition of multi-talker vowels was highly dependent on frequency allocation for all electrode configurations. For a given electrode configuration maximum vowel recognition was observed with a specific frequency allocation. When the stimulated electrodes were shifted basally by 3 mm, the frequency allocation that produced the best performance also shifted basally by 3 mm. A similar pattern of vowel recognition was observed as a function of frequency allocation for electrode configurations that had the same apical-most electrode in each pair, regardless of location of the basal-most electrode in the pair. Subjects with different electrode insertion depths had similar trends in vowel recognition for each frequency allocation. CONCLUSIONS: For a given electrode configuration, the best performance was obtained with processors with a specific frequency allocation. In addition, the apical-most member of each electrode pair had a much stronger influence on vowel recognition in electric hearing. Finally, results from this study also suggest that over time, patients with implants can partially adapt to a basal shift in place of stimulation.

Adult↗

Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearing.

The present study measured the recognition of spectrally degraded and frequency-shifted vowels in both acoustic and electric hearing. Vowel stimuli were passed through 4, 8, or 16 bandpass filters and the temporal envelopes from each filter band were extracted by half-wave rectification and low-pass filtering. The temporal envelopes were used to modulate noise bands which were shifted in frequency relative to the corresponding analysis filters. This manipulation not only degraded the spectral information by discarding within-band spectral detail, but also shifted the tonotopic representation of spectral envelope information. Results from five normal-hearing subjects showed that vowel recognition was sensitive to both spectral resolution and frequency shifting. The effect of a frequency shift did not interact with spectral resolution, suggesting that spectral resolution and spectral shifting are orthogonal in terms of intelligibility. High vowel recognition scores were observed for as few as four bands. Regardless of the number of bands, no significant performance drop was observed for tonotopic shifts equivalent to 3 mm along the basilar membrane, that is, for frequency shifts of 40%-60%. Similar results were obtained from five cochlear implant listeners, when electrode locations were fixed and the spectral location of the analysis filters was shifted. Changes in recognition performance in electrical and acoustic hearing were similar in terms of the relative location of electrodes rather than the absolute location of electrodes, indicating that cochlear implant users may at least partly accommodate to the new patterns of speech sounds after long-time exposure to their normal speech processor.

Adult↗

Within-channel gap detection using dissimilar markers in cochlear implant listeners.

Temporal gap detection thresholds were measured between perceptually dissimilar electrical markers in cochlear implant listeners. Both markers were presented to the same electrode pair. The amplitude and pulse rate of the first marker were fixed, and gap thresholds were measured as a function of either the pulse rate or the amplitude of the second marker. In either case, U-shaped functions were obtained, with lowest gap thresholds occurring when the two markers were similar in both amplitude and pulse rate. Because the two markers were presented to the same electrode pair, the data cannot be accounted for on the basis of across-channel interactions. It is hypothesized that when different markers are used, the perceptual discontinuity from the first marker to the second is similar to the sensation of a brief gap, and dominates the gap detection process. Thus, gap threshold functions with electrically dissimilar markers serve more as indicators of perceptual distance between the markers and less as measures of temporal resolution.

Auditory Threshold↗

Importance of tonal envelope cues in Chinese speech recognition.

Recent studies have shown that temporal waveform envelope cues can provide significant information for English speech recognition. This study investigated the use of temporal envelope cues in a tonal language: Mandarin Chinese. In this study, the speech was divided into several frequency analysis bands; the amplitude envelope was extracted from each band by half-wave rectification and low-pass filtering and was used to modulate a noise of the same bandwidth as the analysis band. These manipulations preserved temporal and amplitude cues in each frequency band, but removed the spectral detail within each band. Chinese vowels, consonants, tones and sentences were identified by 12 native Chinese-speaking listeners with 1, 2, 3, and 4 noise bands. The results showed that the recognition score of vowels, consonants, and sentences increased monotonically with the number of bands, a pattern similar to that observed in English speech recognition. In contrast, tones were consistently recognized at about 80% correct level, independent of the number of bands. This high level of tone recognition produced a significant difference in the open-set sentence recognition between Chinese (11.0%) and English (2.9%) for the one-band condition where no spectral information was available. The data also revealed that, with primarily temporal cues, the falling-rising tone (tone 3) and the falling tone (tone 4) were more easily recognized than the flat tone (tone 1) and the rising tone (tone 2). This differential pattern in tone recognition resulted in a similar pattern in word recognition: words having either tone 3 or 4 were more likely to be recognized while words having tone 1 and 2 were not. The quantitative role of tones in Chinese speech recognition was further explored using a power-function model and found to play a significant role in relating phoneme recognition to sentence recognition.

Adult↗

Effects of amplitude nonlinearity on phoneme recognition by cochlear implant users and normal-hearing listeners.

It is widely assumed that the proper transformation of acoustic amplitude to electric amplitude is a critical factor affecting speech recognition in cochlear implant users and normal-hearing listeners. A four-channel noise-band speech processor was implemented, reducing spectral information to four bands. A power-law transformation was applied to the amplitude mapping stage in the speech processor design, and the exponent of the power function varied from a strongly compressive (p = 0.05) to a weakly compressive (p = 0.75) for implant listeners and from 0.3 to 3.0 for acoustic listeners. Results for implants showed that the best performance was achieved with an exponent of about 0.2, and performance gradually deteriorated when either more compressive or less compressive exponents were applied. The loudness growth functions of the four activated electrodes in each subject were measured and those data were well fit by a power function with a mean exponent of 2.72. The results indicated that the best performance was achieved when the normal loudness growth was restored. For acoustic listeners, results were similar to those observed with cochlear implant listeners, except that best performance was achieved with no amplitude nonlinearity (p = 1.0). The similarity of results in both acoustic and electric stimulation indicated that the performance deterioration observed for extreme nonlinearity was due to similar perceptual effects. The function relating amplitude mapping exponent and performance was relatively flat, indicating that phoneme recognition was only mildly affected by amplitude nonlinearity.

Adult↗

Effects of noise and spectral resolution on vowel and consonant recognition: acoustic and electric hearing.

Current multichannel cochlear implant devices provide high levels of speech performance in quiet. However, performance deteriorates rapidly with increasing levels of background noise. The goal of this study was to investigate whether the noise susceptibility of cochlear implant users is primarily due to the loss of fine spectral information. Recognition of vowels and consonants was measured as a function of signal-to-noise ratio in four normal-hearing listeners in conditions simulating cochlear implants with both CIS and SPEAK-like strategies. Six conditions were evaluated: 3-, 4-, 8-, and 16-band processors (CIS-like), a 6/20 band processor (SPEAK-like), and unprocessed speech. Recognition scores for vowels and consonants decreased as the S/N level worsened in all conditions, as expected. Phoneme recognition threshold (PRT) was defined as the S/N at which the recognition score fell to 50% of its level in quiet. The unprocessed speech had the best PRT, which worsened as the number of bands decreased. Recognition of vowels and consonants was further measured in three Nucleus-22 cochlear implant users using either their normal SPEAK speech processor or a custom processor with a four-channel CIS strategy. The best cochlear implant user showed similar performance with the CIS strategy in quiet and in noise to that of normal-hearing listeners when listening to correspondingly spectrally degraded speech. These findings suggest that the noise susceptibility of cochlear implant users is at least partly due to the loss of spectral resolution. Efforts to improve the effective number of spectral information channels should improve implant performance in noise.

Adult↗