Three-dimensional echocardiographic evaluation of aortic disorders with rotational multiplanar imaging: experimental and clinical studies.

Transesophageal echocardiography has become a highly valuable method to assess aortic disorders. With this method, however, aortic disease has been visualized only in two-dimensional views. Advances in computer technology have introduced three-dimensional (3D) echocardiography as a developing modality in cardiac imaging. Previous efforts to obtain 3D reconstructions of the aorta, by various techniques, had limited clinical applicability. In this study we attempted to explore the feasibility and potential of 3D reconstructions of the aorta employing a widely used multiplane transesophageal imaging technique in an experimental setting and in patients. In the in vitro study, we created 35 lesions in 28 pig aortic trees (15 aortic dissections, five saccular aneurysms, five coarctations, five atheromas, and five clots within dissections). Suspending these specimens in a water bath, sequential two-dimensional images were acquired over a 180-degree rotation with a commercially available multiplane transesophageal probe and ultrasound system with a 3D software package. Data processing (digital reformation, interpolation, and segmentation) and 3D display were accomplished on an off-line computer system. 3D reconstructions were achieved and displayed in wire-frame, surface-rendered, and volume-rendered images. These 3D reconstructions corresponded well with the actual anatomic specimens in delineating the various pathologic findings. In patient studies, we collected a total of 36 studies in both adults and children with a mean age of 44.5 years (range 1 month to 82 years). In addition to normal aortas (n = 13), the spectrum of abnormalities studied included six atheromatous lesions, four aortic dissections, 10 coarctations, one aneurysm with a thrombus, and one dilated aortic root. We were able to accomplish volume-rendered 3D images depicting the aortic lesions in their true form that could be viewed in many different perspectives in all patients. We conclude that 3D echocardiography is able to display the aorta and aortic disease in a realistic manner. Although this modality still has limitations, further improvements in computer and ultrasound technology would strengthen 3D echocardiography as a clinically viable diagnostic tool, in the evaluation of aortic disorders.

Adolescent↗

Automatic backscatter analysis of regional left ventricular systolic function using color kinesis.

Assessment of regional wall motion by 2-dimensional echocardiography can be performed by either semiquantitative wall motion scoring or by quantitative analysis. The former is subjective and requires expertise. Quantitative methods are too time-consuming for routine use in a busy clinical laboratory. Color kinesis is a new algorithm utilizing acoustic backscatter analysis. It provides a color encoded map of endocardial motion in real time. In each frame a new color layer is added; the thickness of the color beam represents endocardial motion during that frame. The end-systolic image has multiple color layers, representing regional and temporal heterogeneity of segmental motion. The purpose of this study was to validate the use of color kinesis for semiquantitative analysis of regional left ventricular systolic function and quantitatively in measurement of endocardial excursion. Semiquantitative wall motion scoring was performed in 18 patients using both 2-dimensional echo and color kinesis. Scoring was identical in 74% of segments; there was 84% agreement in definition of normal vs. abnormal. There was less interobserver variability in wall motion scoring using color kinesis. Endocardial excursion was quantified in 21 patients. 70% of the imaged segments were suitable for analysis. Correlation between 2-dimensional echocardiographic measurements and color kinesis was excellent, r = 0.87. The mean difference in excursion as measured by the 2 methods was -0.05 +/- 2.0 mm. In conclusion, color kinesis is a useful method for assessing regional contraction by displaying a color map of systolic endocardial excursion. This algorithm may improve the confidence and accuracy of assessment of segmental ventricular function by echocardiographic methods.

Adult↗

Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: validation in an in vitro model.

Accurate evaluation of atrial septal defect (ASD) size and shape is very important for the selection of patients for transcatheter occlusion. The ability of volume-rendered, three-dimensional echocardiography (3DE) in displaying ASDs in a dynamic mode has been demonstrated; however, its accuracy in sizing ASDs is unknown. To assess this, we performed 3DE of 10 explanted pig hearts in which ASDs of various locations, sizes, and shapes had been experimentally created. From en face 3DE views of the atrial septum containing the defects, major and minor diameters of the defect were measured by a blinded observer, and these data were compared to direct anatomic measurements. The correlations between 3DE and anatomy for the major and minor ASD diameters were y = 0.83x + 3.4 (r = 0.97, p < 0.0001) and y = 0.92x + 1.3 (r = 0.92, p < 0.0001) respectively. The correlation between the measures for major and minor axis ratio was y = 1.06 x - 0.052, r = 0.91, p < 0.0002. Good agreement between both methods of measurements was demonstrated for all measurements. In addition, 3DE portrayed the location and shape of the defects accurately. Thus 3DE provides excellent visualization of ASD and is able to accurately define the size of the defects. These qualitative and quantitative capabilities enhance the clinical potential of this technique in the appraisal of ASDs for decisions regarding application of closure devices.

Animals↗

Dynamic three-dimensional echocardiographic assessment of intracardiac blood flow jets.

Transthoracic dynamic 3-dimensional reconstruction of the heart with tissue depiction has been proved to be feasible when using various methods of data acquisition. The same method can theoretically be applied to color Doppler flows to generate dynamic 3-dimensional images of intracardiac blood flow jets. To explore the feasibility of this approach, we studied 41 patients with various valvular disorders or intracardiac shunts. We acquired sequential 2-dimensional images along with color Doppler information using rotational scanning from a transthoracic or a subcostal window. Images were digitized and processed for 3-dimensional reconstruction using dedicated software. After adequate segmentation, the flow jets were displayed in 3 dimensions in a gray scale format. With use of this approach, 3-dimensional reconstruction of color Doppler flows was possible in all but 1 patient. Still frames allowed immediate appreciation of the shape of the jets, their location in the cardiac chambers, and their size related to that cavity. Dynamic display was even more striking by showing the flow in real time. Dynamic 3-dimensional images enabled visualization of flow jets in projections not available in conventional color flow Doppler, looking directly at the views of shunt and regurgitant flows, and also permitted 3-dimensional delineation of flow convergence zones. We conclude that dynamic visualization of various intracardiac flows in 3 dimensions using transthoracic echocardiography is possible. It provides a better understanding of the shape and size of the jets, and can potentially aid in flow quantification by displaying the actual shape of flow convergence regions.

Adolescent↗

Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography.

OBJECTIVES: This study attempted to determine the site, relative size and dynamic geometry of atrial septal defects using dynamic three-dimensional echocardiography. BACKGROUND: Recent studies have demonstrated the feasibility of dynamic three-dimensional echocardiography. Images are acquired from computerized reconstruction of sequential, tomographic ultrasound "slices" of the heart. Ultrasound images can be obtained by linear progression of a transducer within a transesophageal imaging probe. In small infants and children the large transducer size has not allowed transesophageal placement, and the probe has been placed on the thorax or in the subcostal position. Other scanning devices, housed in plastic containers, acquire images in a rotational format and can also be placed in a transthoracic or subcostal position. METHODS: Specially designed transesophageal probes and a dedicated computer unit were used for two-dimensional image retrieval and reconstruction of three-dimensional images. Sixteen patients with atrial septal defects were studied (median age 18 months, range 1 day to 18 years). In one patient, images were obtained by transesophageal probe placement; in the other 15 patients, the probe was placed in the transthoracic or subcostal position. RESULTS: A dynamic three-dimensional echocardiogram of the atrial septal defect could be obtained in 13 of the 16 patients. The distinguishing features of the atrial septal defects and their spatial orientation could be visualized in unique three-dimensional views. CONCLUSIONS: Dynamic three-dimensional imaging could be applied to the specific evaluation of atrial septal defects. Unique views of the heart allowed for spatial comprehension of the defects, rendering potentially important clinical information.

Echocardiography, Transesophageal↗

Transthoracic real-time three-dimensional echocardiography using a fan-like scanning approach for data acquisition: methods, strengths, problems, and initial clinical experience.

Three-dimensional echocardiography is an emerging clinical method to assess cardiovascular disorders. The feasibility of using a linear mode scanning (parallel slicing) for transthoracic data acquisition has been demonstrated. In this study, we evaluated the feasibility of real-time transthoracic three-dimensional imaging of the heart using a fan-like scanning mode of echocardiographic data acquisition. We used a computer-driven motor to sequentially angulate transthoracic transducers over a fan-like arc up to 90 degrees. With careful ECG and respiratory gating, we acquired basic two-dimensional data set via parasternal and subcostal windows and performed dynamic three-dimensional reconstructions. The problems encountered included the need to repeat data acquisition sequences because of transducer movement or inappropriate gain and gray scale settings. From 15 scanning sequences in four patients, we were able to use ten sets of data. These yielded good quality three-dimensional studies projecting normal valves, a stenotic mitral valve, and an atrial septal defect, in a number of novel views. The valves could be visualized from above and from below as well as in other orientations, and the detailed anatomy appraised. Spatial relationships of the atrial septal defect with inferior and superior vena cava, coronary sinus, or tricuspid annulus could be uniquely displayed through views from the right side of the heart. This technique provided adequate new imaging planes not available from two-dimensional echocardiography. This experience demonstrates for the first time that transthoracic three-dimensional echocardiography using a fan-like scanning mode of data acquisition is feasible, and that it provides adequate visualization of intracardiac structures in unique projections.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Clinical, echocardiographic, and hemodynamic evidence of cardiac tamponade caused by large pleural effusions.

Large pleural effusions are typically associated with dyspnea and potential respiratory compromise. Experimental evidence suggests that with large effusions, increased intrapleural pressure may be transmitted to the pericardial space, resulting in impaired cardiac filling and reduced stroke volume. We report two cases in which large pleural collections were complicated by hypotension. The effusions were due to an infected right hepatic hydrothorax (Case 1) and a left malignant effusion (Case 2). Echocardiography demonstrated right and left ventricular diastolic collapse, respectively, confirming a diagnosis of cardiac tamponade. Large volume thoracentesis resulted in immediate hemodynamic improvement as demonstrated by a reduction in right ventricular and atrial pressures (Case 1) and echocardiographic resolution of left ventricular diastolic collapse (Case 2). These cases establish that large pleural effusions can cause hemodynamically significant cardiac tamponade. In addition, they illustrate how the demonstration of cardiac compressive physiology can significantly alter the therapeutic approach to large pleural effusions.

Adult↗

Determination of cardiac output using acoustic quantification in critically ill patients.

The reliability of automated acoustic quantification (AQ) in yielding real-time left ventricular (LV) area, volume, and ejection fraction has been validated. The purpose of this study was to explore the potential of AQ in providing accurate immediate determination of cardiac output in critically ill patients. A total of 48 patients were studied. One group consisted of 37 critically ill patients with indwelling Swan-Ganz catheters. In these patients, cardiac output by AQ, manual tracing of end-diastolic and end-systolic frames of 2-dimensional images, and thermodilution were measured. AQ was also compared with Doppler calculation of flow through the left and right ventricles in 11 additional patients. Adequate data for calculation of cardiac output with AQ were obtained in 78% of critically ill patients. There was an excellent correlation between AQ and off-line manual analysis for LV volumes (r = 0.94 and 0.91 for end-diastole and end-systole), ejection fraction (r = 0.85), and cardiac output (r = 0.93). AQ also correlated well with Doppler analysis (r = 0.97) and thermodilution technique (r = 0.95) in the determination of cardiac output. However, AQ slightly underestimated thermodilution measurements, with rather wide limits of agreement (-0.3 +/- 1.1 liter/min). There was a similar underestimation of cardiac output with manual analysis when compared with thermodilution. Given the absence of significant differences between AQ and manual analysis, this observation suggests that the bias is related to the echocardiographic determination of stroke volume, and not to errors from the automated border detection. It is concluded that AQ, besides providing information on LV volumes and ejection fraction, also can yield rapid measurements of cardiac output in most patients who are acutely ill.

Acoustics↗

Simulation of intraoperative visualization of cardiac structures and study of dynamic surgical anatomy with real-time three-dimensional echocardiography.

Most prior efforts of 3-dimensional (3-D) reconstruction of echocardiographic images have focused on quantitation of ventricular size and function. The resulting images have been displayed in the wire mesh format. Recently, a method for 3-D transesophageal echocardiography using a computer-controlled probe that acquires parallel tomographic slices has been described. This technique provides dynamic 3-D volume-rendered images of the heart. This study was designed to determine if surgical visualization of intracardiac anatomy could be simulated using this imaging system. Data acquired from 8 patients with congenital and acquired heart disease were analyzed. Real-time 3-D images of the cardiac chambers and valves were obtained. Images of the cardiac pathology including fibrocalcific nodules on the aortic valve, mitral valve endocarditis, rheumatic mitral stenosis, and an ostium secundum atrial septal defect were displayed in 3 dimensions that simulated surgical exposure of these structures. These 3-D representations of cardiac anatomy were in some ways superior to standard intraoperative visualization in that they demonstrated the heart as a dynamic structure, as opposed to the empty, nonbeating heart observed while on cardiopulmonary bypass. In conclusion, 3-D images of cardiac structures as seen by the surgeon intraoperatively can be provided using a computer-driven tomographic transesophageal echocardiographic probe. This imaging system can be potentially useful in the planning and evaluation of cardiac surgery. Technical improvements such as 3-D representation of flow jets, the ability to manipulate images to simulate cardiac surgery, and on-line reconstruction can make this a powerful tool in the future.

Computer Simulation↗

Clinical usefulness of multiplane transesophageal echocardiography: comparison to biplanar imaging.

The increased diagnostic usefulness of multiplane over biplane transesophageal echocardiography has not yet been conclusively determined. In this study the diagnostic yield of multiplanar and biplanar imaging was compared blindly by using the information content obtained from multiplane transesophageal echocardiography to that derived from biplanar type of imaging planes available in the multiplane echocardiography recordings in 80 patients with a variety of cardiac disorders. Among these patients 9 new abnormalities were identified by multiplane transesophageal echocardiography in 8 patients. Multiplane imaging yielded better delineation of 40 various lesions in 31 patients. Thus multiplane transesophageal echocardiography has a greater diagnostic yield than biplane imaging by depicting more lesions in 10% of patients and by enhanced delineation of the extent of pathologic characteristics in 39% of patients. This versatility, coupled with the ease of obtaining a vast assembly of imaging planes without undue probe manipulations, makes multiplane transesophageal echocardiography more useful than biplanar imaging.

Echocardiography↗

Dynamic three-dimensional echocardiographic imaging of congenital heart defects in infants and children by computer-controlled tomographic parallel slicing using a single integrated ultrasound instrument.

Three-dimensional cardiac reconstruction generated from transesophageal interrogation can be performed using an integrated unit that captures, processes, and postprocesses tomographic parallel slices of the heart. This probe was used for infants and young children in the transthoracic position to evaluate the feasibility of producing three-dimensional cardiac images with capability for real-time dynamic display. Twenty-two infants and children (range 1 day-3.5 years) underwent image acquisition using a 16 mm 5 MHz 64 element probe placed over the precordium. Two infants were also imaged from the subcostal position. Data was obtained and stored over a single cardiac cycle after acceptable cardiac and respiratory gating intervals were met. The transducer was advanced in 0.5-1 mm increments over the cardiac structures using identical acquisition criteria. The images were reconstructed from the stored digital cubic format and could be oriented in any desired plane. In 9 of the 22 infants the images obtained were of optimal quality. The images obtained displayed normal cardiac structures emphasizing depth relationships as well as visualization of planes not generally demonstrated by two-dimensional imaging. Several lesions were also depicted in a unique fashion using this technique. Though the method employed was limited by movement artifact and reconstruction time, the quality of the three-dimensional display was excellent and enhanced by real-time demonstration. The transthoracic approach was successful in capturing sufficient data to create three-dimensional images, which may have further application in more accurate diagnosis of complex cardiac abnormalities and generation of planes of view which could duplicate surgical visualization of a lesion. Further assessment of the technique in infants with congenital heart disease is warranted.

Child, Preschool↗

Enhanced comprehension of dynamic cardiovascular anatomy by three-dimensional echocardiography with the use of mixed shading techniques.

Advances in ultrasound instrumentation and computer technology provide us an opportunity to develop methods to perform three-dimensional echocardiography in patients. Optimal methods of displaying three-dimensional images are critical for the perception of depth and distances. We examined the utility of various shading techniques in volume-rendered three-dimensional images in 22 patients with a variety of cardiac defects. Distance coding, gray level gradient shading, texture shading, and mixtures of these shading techniques were used. Our observations suggest that the mixture of shading techniques portray the dynamic three-dimensional anatomy better than a single type of shading. Appropriate mix of shadings could provide dynamic three-dimensional echocardiograms of clinical utility.

Echocardiography↗

Left ventricular diastolic collapse in regional left heart cardiac tamponade. An experimental echocardiographic and hemodynamic study.

OBJECTIVES: This study was designed to describe the hemodynamic abnormalities associated with the appearance of left ventricular diastolic collapse in the setting of regional left heart cardiac tamponade. BACKGROUND: Cardiac tamponade after heart surgery is frequently associated with localized pericardial effusion. Although right ventricular diastolic collapse and right atrial collapse are reliable echocardiographic findings in patients with circumferential pericardial effusion and tamponade, they are often not present in postoperative patients with localized pericardial effusion and regional left heart tamponade. Left ventricular diastolic collapse has been described in such patients, but the degree of hemodynamic alteration that exists with this finding is not known. METHODS: Acute regional left heart tamponade was produced 14 times in seven spontaneously breathing anesthetized dogs by infusing fluid into an isolated compartment created in the pericardial space adjacent to the left ventricular free wall. Continuous echocardiographic imaging and hemodynamic monitoring of left ventricular, systemic arterial, right atrial, pulmonary capillary wedge and pericardial pressures were performed. Measurements at baseline were compared with those made at the onset of left ventricular diastolic collapse and at decompensated tamponade. RESULTS: Left ventricular diastolic collapse was noted in all 14 episodes of regional tamponade. It occurred when pressure in the left pericardial compartment exceeded left ventricular diastolic pressure by 3.0 +/- 1.9 mm Hg. At the onset of left ventricular diastolic collapse, cardiac output and mean arterial pressure were significantly reduced from the control value (p < 0.05). Systolic hypotension was noted only twice at this stage, respiratory variation in systolic pressure > 10 mm Hg only once. The appearance of this sign was also associated with elevated left heart filling pressures. CONCLUSIONS: Left ventricular diastolic collapse is a reliable sign of regional left ventricular tamponade and is associated with a reduction in cardiac output. This echocardiographic finding usually occurs before the development of arterial hypotension and pulsus paradoxus. Thus, left ventricular diastolic collapse is potentially more reliable than hypotension or pulsus paradoxus in the diagnosis of regional left ventricular tamponade.

Acute Disease↗

[Increased concentration of plasma atrial natriuretic peptide in patients with acute stroke and its significance].

Plasma atrial natriuretic peptide (ANP) was measured with radioimmunoassay in 39 patients with acute stroke. The mean level was 144.3 +/- 8.7 pg/ml; this was significantly higher in comparison with those in normal controls (55.8 +/- 4.7 pg/ml, n = 20) and hypertension patients (87.7 +/- 8.0 pg/ml, n = 15). Serial measurement of ANP level in 6 patients showed that it was elevated on the first day of the stroke, reached to its peak on the second or third day and returned to normal after two weeks. Five patients had hyponatremia following the attack of stroke and the plasma ANP level was further elevated. It is suggested that elevated plasma ANP level might be a pathogenetic factor of the accompanying hyponatremia in stroke.

Aged↗

Multiplane transesophageal echocardiography. Imaging planes, echocardiographic anatomy, and clinical experience with a prototype phased array OmniPlane probe.

Multiplane transesophageal echocardiography is a new exciting development in echocardiography. We examined the methodology and echo-anatomic correlations of multiplane transesophageal echocardiography and its clinical applications in 100 patients. We used a 5-MHz phased array multiplane (OmniPlane) transesophageal probe. In this instrument, the transducer array can be steered through 180 degrees from any transducer location. This provides a vast assembly of imaging planes, allowing for detailed visualization of all dimensions of cardiac anatomy. This report presents our observations on the echocardiographic anatomy seen in various image planes and the unique clinical potential of multiplane transesophageal echocardiography in the diagnostic assessment of cardiovascular disorders. This technique appears to provide incremental diagnostic information that enhances the interpretative ability. Less esophageal probe manipulation is required with consequent decrease in patient discomfort. We conclude that multiplane transesophageal echocardiography enhances the versatility of transesophageal examination and offers many new avenues for developments such as three-dimensional echocardiography.

Echocardiography↗

Three-dimensional and four-dimensional transesophageal echocardiographic imaging of the heart and aorta in humans using a computed tomographic imaging probe.

We evaluated the clinical applicability of a prototype tomographic transesophageal echocardiographic (TEE) system, which not only provides conventional TEE images but also three-dimensional tissue reconstruction and four-dimensional display capabilities. The probe was used in 16 patients in the echocardiographic laboratory, intensive care unit, and the operating room. The instrument is a 5-MHz, 64-element, phased array unit mounted on a sliding carriage within a casing. After appropriate probe placement within the esophagus, the probe is straightened, a balloon surrounding the probe is inflated, and data acquisition begun with ECG and respiration gating. With computer controlled transducer movement at 1-mm increments, a complete cardiac cycle is recorded at each tomographic level. These are processed using a dedicated four-dimensional software, and displayed as a dynamic three-dimensional tissue image of the heart. We were able to see the dynamic motion of the ventricles and all the valves in the four-dimensional format. In addition to four-dimensional display, we were able to cut and visualize the heart in dynamic mode in any desired plane and also in multiple planes. Patients tolerated the procedure well. We conclude that this tomographic four-dimensional approach, which does not require tedious off-line processing, can easily be performed in patients and has a strong clinical potential.

Aorta↗

Role of transforming growth factor beta in the proliferative effect of 2,3,7,8-tetrachlorodibenzo-p-dioxin on human squamous carcinoma cells.

The highly toxic environmental contaminant 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) has recently been shown to stimulate proliferation of two human squamous carcinoma cell lines, SCC-15G and SCC-25, by decreasing the sensitivity of the cells to high density growth arrest. TCDD is known to alter the activity of several endogenous growth-regulatory compounds, and this study was undertaken to investigate the possibility that modulation of transforming growth factor beta (TGF-beta) activity might be involved in the mechanism of growth stimulation by TCDD. TGF-beta inhibited monolayer growth and DNA synthesis of SCC-15G and SCC-25 cells equally well in the presence and the absence of 10 nM TCDD. TCDD alone stimulated proliferation and inhibited differentiation in both cell lines but had no effect on binding of 125I-TGF-beta to or secretion of TGF-beta by SCC-15G cells. Inhibition of growth of SCC-15G cultures by TGF-beta was incomplete, in that cell number continued to increase even in the presence of 100 pM TGF-beta, although at a greatly reduced rate compared to non-TGF-beta-treated controls. These cells, grown in 100 pM TGF-beta alone, reached growth arrest at the same density as non-TGF-beta-treated cultures but failed to reach density-dependent growth arrest when treated with TCDD. Cells treated for 12 h with TCDD exhibited maximal induction of ethoxyresorufin-O-deethylase activity. TGF-beta inhibited this induction in a dose-dependent manner even when added after a 12-h TCDD pretreatment. The inhibition was rapidly reversible after removal of TGF-beta, indicating that it occurred via a mechanism which did not involve inhibition of very early steps in the TCDD response pathway. These results demonstrate that the stimulatory effect of TCDD on keratinocyte proliferation is not mediated through alterations in TGF-beta activity and that TCDD and TGF-beta appear to exert their opposite effects on cellular proliferation by independent mechanisms.

Biological Transport↗