PubMed Health⌕ Search

Biomedical subjects

Q Peng

Publications and source records attributed to Q Peng.

At least 37 records · Page 2Linked to original sources

Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.

PURPOSE: To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. RESULTS: The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. CONCLUSIONS: Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.

Acrylic Resins↗

Linkage analysis of the 5q31-33 candidate region for asthma in 240 UK families.

Atopy and asthma are complex genetic diseases resulting from the interactions of a number of genetic and environmental factors. We had previously reported allelic association between the IL9 marker on chromosome 5q31-33 and atopy. In order to further investigate the role of susceptibility genes on 5q31-33 in the development of atopy and asthma we have studied 240 UK families comprising 131 families selected at random, 60 multiplex families with affected sib pairs, and 49 single proband nuclear families. Polymorphic markers on 5q31-33 were genotyped and both single and multipoint linkage analysis was undertaken using the BETA program. We have used both affection status and quantitative scores for atopy and asthma for phenotypic variables, combining data into scores for asthma and atopy. The strongest suggestion of linkage using multipoint analysis was centred around D5S410 with a maximum Lod of 1.946 at location 171.3 cM and a standard error of 3.3 for the asthma quantitative score. There was no evidence of linkage with atopy, the atopy quantitative score or total serum IgE.

Asthma↗

[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].

BACKGROUND: The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape. MATERIALS AND METHODS: Human eyes obtained post-mortem implanted with 3-piece silicone optic - PMMA haptic (SI 40 NB) and 3-piece silicone optic - Prolene haptic (SI 30 NB) designs IOLs, accessioned between January 1993 and December 2000 were evaluated by gross examination from behind under an operating microscope using the Miyake-Apple posterior photographic technique. The area and intensity of Soemmerring's ring and type of fixation was studied in 457 eyes. The mean diameter of the CCC and relation of the CCC edge to the optic rim were analyzed in 221 eyes. RESULTS: 1) The amount of Soemmerring's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy in both the SI 40 NB and SI 30 NB design than in the IOLs without capsulotomies. 2) The percentage of not in-the-bag fixated IOLs in both the SI 40 NB and SI 30 NB design was larger in the "Nd:YAG groups", without being statistically significant. 3) The "Nd:YAG groups" showed a significant higher amount of non overlapping clock hours of the CCC edge in relation to the optic rim. CONCLUSION: 1) The data confirm the clinical assumption that the incidence of PCO is correlated with the cortical clean up. 2) Our findings also support the clinical assumption, that poor IOL fixation increases the risk of PCO. 3) This study also verifies the relation of the CCC to PCO, namely a relatively small CCC covering the entire optic rim is best to reduce the Nd:YAG laser rate.

Cataract↗

[Postoperative opacification of posterior chamber intraocular lenses - a review].

Postoperative opacification of intraocular lenses (IOLs) is a very unpleasant complication for the ophthalmic surgeon and the patient. We report on our experiences with opacification of different foldable IOL designs and rigid poly (methyl methacrylate) (PMMA) posterior chamber lenses.1. Snowflake degeneration of PMMA IOLs: This condition is an unanticipated and surprising late postoperative finding 8 to 15 years after implantation. In our opinion, this complication is probably not related to the PMMA biomaterial itself, but rather it appears to represent a manufacturing problem that has affected a selected, albeit large number of lenses manufactured in the 1980s-mid 1990s.2. Degeneration of UV absorber material and calcium deposits within the optic of hydrophilic IOLs: Two years postoperatively degenerations of UV absorber material and calcium deposits within the optic of single piece hydrophilic acrylic lenses SC60B-OUV manufactured by MDR (Medical developmental research Inc. Clearwater FL, USA) can occur. Although the precise mechanism is not fully known, it was assumed that these opacifications are due to premature aging of the UV blocking agent incorporated in the lens biomaterial and calcification.3. Calcification on the surface of the Bausch & Lomb Hydroviewtrade mark IOLs: Twelve to 15 months postoperatively granular surface calcifications in Hydroviewtrade mark IOLs occured. The mechanism is not fully understood. According to Bausch and Lomb studies, part of the components of the packaging contained silicone, which may have come off the packaging onto the lens optic, where it then appears to be a catalyst for calcium precipitation. The manufacturer has correlated a change in packaging with the appearance of the opacification. The manufacturer now believes that this problem has been solved. However, final verification will require a careful 1 - 2 years clinical study.4. Glistenings in the hydrophobic acrylic AcrySoftrade mark IOLs: The time frame of glistenings in the AcrySoftrade mark IOLs is highly variable. It has been suggested that the occurrence of glistenings may be related to variations in the temperature of the lens just prior to and or during insertion into the eye. Formation of vacuoles may occur within the submersed acrylic polymer when there is a transient increase and then decrease in temperature during the surgical procedure. "Glistenings" may then subsequently form by ingress of anterior chamber fluid. Contrast sensitivity can been decreased in some patients, but clinically significant decrease of visual acuity has been rare.

Biocompatible Materials↗

[Millenniums update on posterior capsule opacification (PCO) scores, centration, biocompatibility and fixation of foldable intraocular lenses (IOL) - an analysis of 1,221 pseudophakic post mortem globes].

BACKGROUND: The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States. MATERIAL AND METHODS: We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique. RESULTS: The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySoftrade mark IOL displays the the lowest (best) biocompatibility score. CONCLUSIONS: Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing.

Autopsy↗

Endogenous production of protoporphyrin IX induced by 5-aminolevulinic acid in leukemia cells.

AIM: To explore the photosensitization of 5-aminolevulinic acid (ALA) in myeloid leukemia cell line. METHODS: Using the technique of fluorescence spectra, the A LA induced protoporphyrin IX (Pp IX) was measured in myeloid leukemia JCS cells. Cofocal laser scanning microscopy (CLSM) combined with fluorescence organelle probe was used to detect the localization of Pp IX in JCS cells at the subcellular levels. MTT assay was used to measure the cell survival after light irradiation. RESULTS: ALA successfully produced endogenous PpI X in leukemia JCS cells. PpIX was observed to be distributed in the cytoplasm and mitochondria was exhibited as the one of binding sites of PpIX. As a photosensitizer, PpIX initiated photodynamic reaction after light irradiation and effectively photodamaged leukemia cells. CONCLUSION: ALA-based photosensitization could be used for inactivation of leukemia cells.

Aminolevulinic Acid↗

[Determination of trace amount of cadmium with vapor generation and atomic absorption spectrometry].

OBJECTIVE: This study aimed to establish a sensitive method for the determination of trace amount of cadmium. METHODS: The reaction systems for the generation of volatile cadmium species were investigated with vapor generation and atomic absorption spectrometry. RESULTS: It was found that potassium ferricyanide with hydroxylamine hydrochloride greatly enhanced the generation efficiency of the volatile species. The reaction parameters using ferricyanide-hydroxyamine-tetrahydroborate in acidic acqueous solution were optimized for efficient generation of volatile cadmium species. A detection limit (3 sigma blank, peak height mode) of 11 pg/ml was obtained under optimized conditions. The RSD of the determinations for 0.2 ngCd/ml was 3.4%. The effects of 33 diverse ions on the generation of the cadmium volatile species were investigated. The method was applied to the determination of cadmium in standard reference materials, the results obtained were in good agreement with the certified values. CONCLUSION: The method can be applied to the determination of trace cadmium in environment and food samples.

Cadmium↗

[Analysis of the lineshape of laser frequency modulation].

In this paper, we analyze the dependence of the output signal spectral lineshape and intensity on the modulation, waveform and modulation index in first- and second-harmonic detection of triangle modulation, square demodulation and saw modulation square demodulation. The signal lineshape in the case of saw modulation, square demodulation is quite different from, whereas the signal lineshape in the case of triangle modulation, square demodulation is similar to that in traditional sine modulation, sine demodulation. Experiments of tunable IR laser frequency modulation absorption spectrum of methane are also done to verify the theoretical analysis. Then we reach a conclusion; the lineshape and intensity of frequency modulation spectrum can be influenced by modulation waveform, demodulation waveform and modulation index. Calculation results can be used to choose better experimental parameters and optimize experimental designs.

Algorithms↗

Pycnogenol inhibits tumor necrosis factor-alpha-induced nuclear factor kappa B activation and adhesion molecule expression in human vascular endothelial cells.

The transcriptional regulatory protein nuclear factor kappa B (NF-kappa B) participates in the control of gene expression of many modulators of inflammatory and immune responses, including vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1). The heightened expression of these adhesion molecules has been reported to play a critical role in atherosclerosis, inflammation, ischemic vascular disorders, diabetes, and cancer metastasis. In the present study, we investigated the effect of pycnogenol, an antioxidant phytochemical, on the activation of NF-kappa B and the induction of VCAM-1 and ICAM-1 in tumor necrosis factor (TNF)-alpha-treated human umbilical vein endothelial cells (HUVECs). Gel-shift analysis of HUVEC demonstrated that pretreatment with pycnogenol exhibited a concentration-dependent suppression of TNF-alpha-induced activation of NF-kappa B. Induction of VCAM-1 and ICAM-1 surface expression by TNF-alpha was dose-dependently reduced by pycnogenol. TNF-alpha significantly increased the release of superoxide anion and hydrogen peroxide from HUVECs. Pycnogenol dose-dependently inhibited their release. The ability of pycnogenol to inhibit NF-kappa B activation and VCAM-1 and ICAM-1 expression suggests that this phytochemical may play an important role in halting or preventing the atherogenic process.

Antioxidants↗

Anterior capsule opacification: a histopathological study comparing different IOL styles.

OBJECTIVE: To compare the degree of anterior capsule opacification (ACO) in human eyes obtained post-mortem containing various rigid and foldable posterior chamber intraocular lens (PC-IOL) designs. DESIGN: Comparative autopsy tissue study with clinicopathologic correlations. MATERIALS: Four hundred sixty human globes containing the following PC-IOL styles were analyzed: (1) one-piece polymethylmethacrylate (PMMA) optic-PMMA haptic (n = 50), (2) one-piece silicone-plate IOL, large hole (n = 40), (3) one-piece silicone-plate IOL, small hole (n = 67), (4) three-piece PMMA optic-PMMA/Prolene haptic (n = 51), (5) three-piece acrylic optic-PMMA haptic (n = 96), (6) three-piece silicone optic-PMMA haptic (n = 24), (7) three-piece silicone optic-polyimide haptic (n = 40), and (8) three-piece silicone optic-prolene haptic (n = 92). TESTING: The globes were sectioned in the equatorial plane for gross examination and then processed through paraffin; sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome stains; and examined by light microscopy. MAIN OUTCOME MEASURES: Anterior capsule opacification was scored in each eye by grading the histologic sections from 0 to III, according to the amount (thickness) of proliferative tissue and cells measured in sagittal sections on the inner surface of the anterior capsule at the capsulorhexis margin. RESULTS: The difference among the eight groups was significant (P < 0.0001). Mean ACO scores were highest with the large and small hole one-piece silicone-plate lenses (1.77 +/- 0.86 and 1.28 +/- 0.77, respectively). The lowest mean score was observed in the group of three-piece acrylic optic-PMMA haptics lenses (0.51 +/- 0.52). CONCLUSIONS: Our results confirm previous clinical observations that the rate of ACO is relatively high with plate-haptic silicone IOLs. The lowest rate was noted with the three-piece acrylic optic-PMMA haptic IOL. The IOL design and IOL material are significant factors in the development of ACO.

Cataract↗

Surgical prevention of posterior capsule opacification. Part 3: Intraocular lens optic barrier effect as a second line of defense.

PURPOSE: To emphasize an important aspect of preventing posterior capsule opacification (PCO), the barrier effect established by the optic of a posterior chamber intraocular lens (PC IOL), and present a new classification regarding capsular bag status after extra-capsular cataract extraction, including phacoemulsification. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: This analysis included 150 consecutive eyes obtained postmortem with United States-manufactured PC IOLs including (1) poly(methyl methacrylate), (2) silicone, and (3) hydrophobic acrylic designs that were accessioned in the Center from September 1995 to January 1, 1998. Gross photographs from behind (Miyake-Apple views) were taken and serial histologic sections prepared. RESULTS: Microscopic analysis of the 150 eyes showed that the morphologic appearance of the capsular bag could be grouped into 2 categories: (1) those with little or no evidence of retained cortical material and cells, and (2) those with retained cortical material and cells in which a Soemmering's ring formed. With the latter, when a distinct barricade to cellular migration created by the IOL optic was noted, 2 discrete configurations occurred, depending on the different geometries of the optic components. With a classic biconvex optic with a curved and tapered edge, in many instances some ingrowth of cells proceeded posteriorly around the edge of the IOL optic in the direction of the central axis. With a lens optic that had a squared, truncated, and relatively thick edge, there was often abrupt termination of cells at the peripheral edge of the optic. The posterior capsule subtending the entire optic zone was therefore relatively or totally cell free. CONCLUSIONS: The barrier effect of the IOL optic appears to be of critical importance in retarding ingrowth of cells, functioning as a second line of defense when cortical cleanup is incomplete. Analysis of PC IOLs obtained postmortem showed that a square, truncated optic edge seemed to provide the maximum impediment to cell growth behind the IOL optic.

Acrylic Resins↗

Surgical prevention of posterior capsule opacification. Part 1: Progress in eliminating this complication of cataract surgery.

PURPOSE: To evaluate over almost 2 decades the success of a component of cataract surgery that represents a critical step in reducing the incidence of posterior capsule opacification (PCO); namely, the efficacy of cortical cleanup. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Department of Ophthalmology, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Accessioned from the early 1980s to 1997, 3320 eyes obtained postmortem with posterior chamber intraocular lenses were analyzed with respect to formation of a postoperative Soemmering's ring. This anatomic lesion, the precursor of clinical PCO, represents an important and measurable indication of the quality of cortical cleanup. Its formation was documented using Miyake-Apple posterior photographic analysis. RESULTS: The quality and thoroughness of cortical cleanup and overall effectiveness in eliminating retained and/or regenerating cortical cells, as measured by scoring of Soemmering's rings, showed virtually no net change since the early 1980s. The intensity of Soemmering's ring was higher in the most recent specimens than in those in the early 1980s. CONCLUSION: The results indicate that renewed attention to cortical cleanup in cataract surgery is warranted for significant reduction in incidence or the elimination of PCO. More attention to the hydrodissection (cortical cleaving hydrodissection) step of the procedure is likely a practical, immediately implementable, and inexpensive remedy.

Cadaver↗