PubMed Health⌕ Search

Biomedical subjects

Qianyong Zhu

Publications and source records attributed to Qianyong Zhu.

2 recordsLinked to original sources

Genomewide oligonucleotide microarray analysis on placentae of pre-eclamptic pregnancies.

OBJECTIVE: Human placentae from normal and pre-eclamptic pregnancies were evaluated for possible changes in gene expression by microarray analysis to uncover new clues for the research of the etiology of pre-eclampsia. METHODS: Placentae from five normal pregnancies and five pregnancies complicated by pre-eclampsia were collected. mRNA levels of five pre-eclamptic placentae were examined using genome-wide 70-mer oligonucleotide microarrays (CapitalBio, Beijing, China) in comparison with the pooled control consisting of total RNA from five normotensive placentae. RESULTS: Ninety-six genes were found consistently down- or up-regulated in at least four pre-eclamptic samples. Most of them were related to an imbalance of reactive oxygen metabolites in placenta, abnormal trophoblast invasion, disorders of lipoprotein metabolism and signal transduction, or some that have been reported to have close correlation to the pathology of pre-eclampsia. The microarray data were also confirmed by the measurement of real-time PCR. CONCLUSION: DNA microarray is a high throughput and time-saving method to monitor altered gene expression. The results could provide interesting clues to the etiology of pre-eclampsia and lead to further studies in a more targeted fashion.

Adult↗

Multichannel piezoelectric genesensor for the detection of human papilloma virus.

OBJECTIVE: To establish a method for rapid detection and sub-typing of human papilloma virus (HPV). METHODS: We utilized the piezoelectric genosensor (PG) technique, which is a combination of the piezoelectric biosensor and gene chips for HPV identification in 22 recurrent biopsy specimens and 22 corresponding original biopsy specimens. The control samples came from normal tissue of healthy persons. A combined reaction took place on the sensor surface between the target genes and probes. The frequency of the piezoelectric sensor will decrease when such reactions occur, and the frequency decrease depends on the concentration of the target gene. Specimens were also analyzed with conventional PCR and dot blot. RESULTS: Of the 22 recurrent specimens, 15 contained HPV6 DNA, 2 HPV11 DNA, and 4 HPV16 DNA. Only one specimen was negative. All the 22 original specimens were positive: 17 harbored HPV6 DNA, 3 sequence homologous HPV11 DNA, and 2 HPV16 DNA. No HPV18 DNA was detected in any specimen. When compared with PCR and dot blot analysis, the results were essentially the same except for one specimen, which was shown to contain other sub-types of HPV. CONCLUSION: Our results show that the piezoelectric genosensor technique is a rapid and specific method to analyze HPV.

Biosensing Techniques↗