Qiao Lin

Publications and source records attributed to Qiao Lin.

7 recordsLinked to original sources

Synthesis and in situ atomic force microscopy characterization of temperature-responsive hydrogels based on poly(2-(dimethylamino)ethyl methacrylate) prepared by atom transfer radical polymerization.

Well-defined copolymers of 2-(dimethylamino)ethyl methacrylate (DMAEMA) and benzophenone methacrylate (BPMA) with different compositions were synthesized via atom transfer radical polymerization. The molecular weights of these copolymers were Mn approximately 30 000 g/mol, while the BPMA content varied from 2.5 to 10 mol %. The copolymers with a low content of BPMA (2.5 and 5 mol %) exhibited a sharp thermal transition at 33-36 degrees C in aqueous solution. A hydrogel was immobilized and patterned on a silicon wafer via UV treatment of the spin-coated polymer layer using a photomask technique. The thermoresponsive behavior of the patterned polymer gel was quantitatively investigated by variable temperature in situ contact mode atomic force microscopy, which revealed the presence of two lower critical solution temperature regions. One region was between 25 and 30 degrees C, corresponding to the topmost layer of the hydrogel film, and the other region, around 40 degrees C, corresponded to the bulk of the hydrogel. Concurrent lateral force microscopy measurements revealed that, just above the transition temperature, the bulk region exhibited enhanced friction.

Free Radicals↗

[The informatics of human genome and traditional Chinese medicine].

Guided by the theory and methodology of yin-yang set derived from Changing Book and Medicine Canon, and using genetics as a bridge, we have tried to bring together the ancient functional systematology and modern structural one as well as Eastern and Western medicine, thereby promoting the modernization of traditional Chinese medicine (TCM) in theory and in clinical practice. Herein, we used virtual technology to transform the genetic information in OMIM of NCBI (National Center for Biotechnology Information of USA, http://www.ncbi.nlm.nih.gov ) into a secondary database in the form of webpages. There are sixteen kinds of the database named gene morbidity ones as followings as: the nature of gene, the profile of common phenotype, a interaction of endogenous, the disease of a organ or a viscera pathogenesis phenomenon, TCM, the sign of diagnosis of western medicine, the gene response to environment, syndrome, disease, nerve and -endocrine, tumor and cancer, psychology and behavior, morbidity, endo-factor of molecular information, expression, the interaction between endogenous and exogenous in which there is 4 711 words, files. The advantages of the database are its aptness for using human fuzzy intelligence to recognize things, suitability to uncovering the noumenon (yinyang) nature of an object and applicability to clinical use.

Computational Biology↗

A model for laminar diffusion-based complex electrokinetic passive micromixers.

This paper presents a model for the efficient and accurate simulations of laminar diffusion-based complex electrokinetic passive micromixers by representing them as a system of mixing elements of relatively simple geometry. Parameterized and analytical models for such elements are obtained, which hold for general sample concentration profiles and arbitrary flow ratios at the element inlet. A lumped-parameter and system-level model is constructed for a complex micromixer, in which the constituent mixing elements are represented by element models, in such a way that an appropriate set of parameters are continuous at the interface between each pair of adjacent elements. The system-level model, which simultaneously computes electric circuitry and sample concentration distributions in the entire micromixer, agrees with numerical and experimental results, and offers orders-of-magnitude improvements in computational efficiency over full numerical simulations. The efficiency and usefulness of the model is demonstrated by exploring a number of laminar diffusion based mixers and mixing networks that occur in practice.

Journal Article↗

Engineering approaches for the detection and control of orthopaedic biofilm infections.

Artificial joints are subject to chronic infections associated with bacterial biofilms, which only can be eradicated by the traumatic removal of the implant followed by sustained intravenous antibiotic therapy. We have adopted an engineering approach to develop electrical-current-based approaches to bacterial eradication and microelectromechanical systems that could be embedded within the implanted joint to detect the presence of bacteria and to provide in situ treatment of the infection before a biofilm can form. In the former case we will examine the combined bactericidal effects of direct and indirect electrical fields in combination with antibiotic therapy. In the latter case, bacterial detection will occur by developing a microelectromechanical-systems-based biosensor that can "eavesdrop" on bacterial quorum-sensing-based communication systems. Treatment will be effected by the release of a cocktail of pharmaceutical reagents contained within integral reservoirs associated with the implant, including a molecular jamming signal that competitively binds to the bacteria's quorum sensing receptors (which will "blind" the bacteria, preventing the production of toxins) and multiple high dose antibiotics to eradicate the planktonic bacteria. This approach is designed to take advantage of the relatively high susceptibility to antibiotics that planktonic bacteria display compared with biofilm envirovars. Here we report the development of a generic microelectromechanical systems biosensor that measures changes in internal viscosity in a base fluid triggered by a change in the external environment.

Biofilms↗

A model for Joule heating-induced dispersion in microchip electrophoresis.

This paper presents an analytical and parameterized model for analyzing the effects of Joule heating on analyte dispersion in electrophoretic separation microchannels. We first obtain non-uniform temperature distributions in the channel resulting from Joule heating, and then determine variations in electrophoretic velocity, based on the fact that the analyte's electrophoretic mobility depends on the buffer viscosity and hence temperature. The convection-diffusion equation is then formulated and solved in terms of spatial moments of the analyte concentration. The resulting model is validated by both numerical simulations and experimental data, and holds for all mass transfer regimes, including unsteady dispersion processes that commonly occur in microchip electrophoresis. This model, which is given in terms of analytical expressions and fully parameterized with channel dimensions and material properties, applies to dispersion of analyte bands of general initial shape in straight and constant-radius-turn channels. As such, the model can be used to represent analyte dispersion in microchannels of more general shape, such as serpentine- or spiral-shaped channels.

Complex Mixtures↗

Surface micromachined electrostatically actuated micro peristaltic pump.

An electrostatically actuated micro peristaltic pump is reported. The micro pump is entirely surface micromachined using a multilayer parylene technology. Taking advantage of the multilayer technology, the micro pump design enables the pumped fluid to be isolated from the electric field. Electrostatic actuation of the parylene membrane using both DC and AC voltages was demonstrated and applied to fluid pumping based on a 3-phase peristaltic sequence. A maximum flow rate of 1.7 nL min(-1) and an estimated pumping pressure of 1.6 kPa were achieved at 20 Hz phase frequency. A dynamic analysis was also performed with a lumped-parameter model for the peristaltic pump. The analysis results allow a quantitative understanding of the peristaltic pumping operation, and correctly predict the trends exhibited by the experimental data. The small footprint of the micro pump is well suited for large-scale integration of microfluidics. Moreover, because the same platform technology has also been used to fabricate other devices (e.g. valves, electrospray ionization nozzles, filters and flow sensors), the integration of these different devices can potentially lead to versatile and functional micro total analysis systems (microTAS).

Equipment Design↗

System-oriented dispersion models of general-shaped electrophoresis microchannels.

This paper presents a system-oriented model for analyzing the dispersion of electrophoretic transport of charged analyte molecules in a general-shaped microchannel, which is represented as a system of serially connected elemental channels of simple geometry. Parameterized analytical models that hold for analyte bands of virtually arbitrary initial shape are derived to describe analyte dispersion, including both the skew and broadening of the band, in elemental channels. These models are then integrated to describe dispersion in the general-shaped channel using appropriate parameters to represent interfaces of adjacent elements. This lumped-parameter system model offers orders-of-magnitude improvement in computational efficiency over full numerical simulations, and is verified by results from experiments and numerical simulations. The model is used to perform a systematic parametric study of serpentine channels consisting of a pair of complementary turn microchannels, and the results indicate that dispersion in a particular turn can contribute to either an increase or decrease of the overall band broadening. The efficiency and accuracy of the system model is further demonstrated by its application to general-shaped channels that occur in practice, including a serpentine channel with multiple complementary turns and a multi-turn spiral-shaped channel. The results indicate that our model is an accurate and efficient simulation tool useful for designing optimal electrophoretic separation microchips.

Electrophoresis, Capillary↗