PubMed Health⌕ Search

Biomedical subjects

Qing X Yang

Publications and source records attributed to Qing X Yang.

15 recordsLinked to original sources

Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

PURPOSE: To investigate the effects of high dielectric material padding on RF field distribution in the human head at 7.0 T, and demonstrate the feasibility and effectiveness of RF passive shimming and focusing with such an approach. MATERIALS AND METHODS: The intensity distribution changes of gradient-recalled-echo (GRE) and spin-echo (SE) images of a human head acquired with water pads (dielectric constant = 78) placed in specified configurations around the head at 7.0 T were evaluated and compared with computer simulation results using the finite difference time domain (FDTD) method. The contributions to the B(1) field distribution change from the displacement current and conductive current of a given configuration of dielectric padding were determined with computer simulations. RESULTS: MR image intensity distribution in the human head with an RF coil at 7.0 T can be changed drastically by placing water pads around the head. Computer simulations reveal that the high permittivity of water pads results in a strong displacement current that enhances image intensity in the nearby region and alters the intensity distribution of the entire brain. CONCLUSION: The image intensity distribution in the human head at ultra-high field strengths can be effectively manipulated with high permittivity padding. Utilizing this effect, the B(1) field inside the human head of a given RF coil can be adjusted to reduce the B(1) field inhomogeneity artifact associated with the wave behavior (RF passive shimming) or to locally enhance the signal-to-noise ratio (SNR) in targeted regions of interest (ROIs; RF field focusing).

Brain↗

A generalization of the two-dimensional prolate spheroidal wave function method for nonrectilinear MRI data acquisition methods.

The two-dimensional (2-D) prolate spheroidal wave function (2-D PSWF) method was previously introduced as an efficient method for trading off between spatial and temporal resolution in magnetic resonance imaging (MRI), with minimal penalty due to truncation and partial volume effects. In the 2-D PSWF method, the k-space sampling area and a matching 2-D PSWF filter, with optimal signal concentration and minimal truncation artifacts, are determined by the shape and size of a given convex region of interest (ROI). The spatial information in the reduced k-space data is used to calculate the total image intensity over a nonsquare ROI instead of producing a low-resolution image. This method can be used for tracking dynamic signals from non-square ROIs using a reduced k-space sampling area, while achieving minimal signal leakage. However, the previous theory is limited to the case of rectilinear sampling. In order to make the 2-D PSWF method more suitable for dynamic studies, this paper presents a generalized version of the 2-D PSWF theory that can be applied to nonrectilinear data acquisition methods. The method is applied to an fMRI study using a spiral trajectory, which illustrates the methods efficiency at tracking hemodynamic signals with high temporal resolution.

Algorithms↗

Central brightening due to constructive interference with, without, and despite dielectric resonance.

PURPOSE: To aid in discussion about the mechanism for central brightening in high field magnetic resonance imaging (MRI), especially regarding the appropriateness of using the term dielectric resonance to describe the central brightening seen in images of the human head. MATERIALS AND METHODS: We present both numerical calculations and experimental images at 3 T of a 35-cm-diameter spherical phantom of varying salinity both with one surface coil and with two surface coils on opposite sides, and further numerical calculations at frequencies corresponding to dielectric resonances for the sphere. RESULTS: With two strategically placed surface coils it is possible to create central brightening even when one coil alone excites an image intensity pattern either bright on one side only or bright on both sides with central darkening. This central brightening can be created with strategic coil placement even when the resonant pattern would favor central darkening. Results in a conductive sample show that central brightening can similarly be achieved in weakly conductive dielectric materials where any true resonances would be heavily damped, such as in human tissues. CONCLUSION: Constructive interference and wavelength effects are likely bigger contributors to central brightening in MR images of weakly conductive biological samples than is true dielectric resonance.

Electromagnetic Fields↗

Measurement and correction of transmitter and receiver induced nonuniformities in vivo.

Signal intensity nonuniformities in high field MR imaging limit the ability of MRI to provide quantitative information and can negatively impact diagnostic scan quality. In this paper, a simple method is described for correcting these effects based on in vivo measurement of the transmission field B1+ and reception sensitivity maps. These maps can be obtained in vivo with either gradient echo (GE) or spin echo (SE) imaging sequences, but the SE approach exhibits an advantage over the GE approach for correcting images over a range of flip angles. In a uniform phantom, this approach reduced the ratio of the signal SD to its mean from around 30% before correction to approximately 6% for the SE approach and 9% for the GE approach after correction. The application of the SE approach for correcting intensity nonuniformities is demonstrated in vivo with human brain images obtained using a conventional spin echo sequence at 3.0 T. Furthermore, it is also shown that this in vivo B1+ and reception sensitivity mapping can be performed using segmented echo planar imaging sequences providing acquisition times of less than 2 min. Although the correction presented here is demonstrated with a simultaneous transmit and receive volume coil, it can be extended to the case of separate transmission and reception coils, including surface and phase array coils.

Algorithms↗

Hexagonal zero mode TEM coil: a single-channel coil design for imaging multiple small animals.

A novel hexagonal coil design for simultaneous imaging of multiple small animals is presented. The design is based on a coaxial cavity and utilizes the magnetic field formed between two coaxial conductors with hexagonal cross-sections. An analytical solution describing the B(1) field between conductors of the hexagonal coil was found from the Biot-Savart law. Both experimental results and analytical calculations showed a variation in the B(1) field within the imaging region of less than 10%. Numerical calculations predicted approximately 35% improvement in B(1) field homogeneity with the hexagonal coil design compared to a cylindrical coaxial cavity design. The experimentally-measured signal-to-noise ratio (SNR) of the hexagonal coil loaded with six 50-mM phantoms was only 4-5% lower than that of a single parallel plate resonator loaded with one phantom. In vivo spin-echo (SE) images of six 7-day-old rat pups acquired simultaneously demonstrated sufficient SNR for microimaging. The construction scheme of the coil, simple methods for tuning and matching, and an anesthesia device and animal holder designed for the coil are described. The hexagonal coil design utilizes a single receiver and allows for simultaneous imaging of six small animals with no significant compromise in SNR.

Animals↗

Functional magnetic resonance imaging study of human olfaction and normal aging.

BACKGROUND: The function of human olfaction declines with advancing age. An important question centers on whether functional alterations to olfactory brain structures accompany age-related behavioral changes. In the present study, we tested the hypothesis that aged adults have intact though reduced activity in the central olfactory system using functional magnetic resonance imaging (fMRI). METHODS: University of Pennsylvania Smell Identification Test (UPSIT) was used to test the smell function of 11 young (23.9 +/- 1.6 years) and 8 aged (66.4 +/- 4.4 years) healthy participants. Then, the participants received fMRI at 3.0 T with lavender and spearmint as stimulants. After fMRI, the participants provided ratings for the odorants' intensity and pleasantness. RESULTS: The average UPSIT score of the aged adults was 34.1 +/- 1.5, which was significantly lower than that of the young adults (37.3 +/- 1.1) (p =.0004). Both age groups showed significant activation in major olfactory brain structures, including the primary olfactory cortex, entorhinal cortex, hippocampus and parahippocampal cortex, thalamus, hypothalamus, orbitofrontal cortex, and insular cortex and its extension into the inferior lateral frontal region. The aged adults showed less brain activity in olfactory structures (p =.022), consistent with lower ratings of odor intensity and UPSIT scores. Activation intensity in bilateral primary olfactory cortex areas and right insular cortex was also comparatively weaker (p <.019). CONCLUSION: Results demonstrate that significant activation in aged adults can be observed in all the olfactory brain structures that are activated in young adults, but with lower activation volume and intensity. This finding provides a necessary baseline for further investigations in olfaction and aging.

Adult↗

Interphalangeal joint cartilage: high-spatial-resolution in vivo MR T2 mapping--a feasibility study.

The purpose of this study was to evaluate feasibility of magnetic resonance (MR) T2 mapping of the proximal interphalangeal joint of the index finger. Cartilage T2 maps with an in-plane resolution of 39 microm were obtained from five asymptomatic subjects-four men and one woman, aged 24-45 years-by using a 3.0-T MR imager. Image acquisition time was 9.6 minutes. All cartilage T2 maps demonstrated spatial variation similar to that reported previously for knee cartilage, with T2 values increasing toward the articular surface. These results demonstrate the feasibility of acquiring cartilage T2 maps of small joints in the hand. Application of T2 mapping techniques to non-weight-bearing joints may provide a means for differentiation of local biomechanical and systemic factors that can affect cartilage T2 values.

Adult↗

Age dependency of cartilage magnetic resonance imaging T2 relaxation times in asymptomatic women.

OBJECTIVE: Because the magnetic resonance imaging (MRI) transverse relaxation time (T2) of cartilage is sensitive to organization of collagen fibers in the cartilage, it may be a noninvasive image marker for senescent changes in cartilage collagen and early cartilage degeneration. The purpose of this study was to determine age-dependent differences in cartilage T2 values in healthy asymptomatic women. METHODS: Quantitative T2 maps of patellar cartilage from 30 asymptomatic women ages 22-86 years were obtained using a 3.0T MRI scanner. The study population was stratified by age into 4 cohorts: 18-30, 31-45, 46-65, and 66-86 years. Spatial differences in cartilage T2 were determined as a function of normalized distance from bone. Older groups were compared with the 18-30-year-old group to determine the effects of age on cartilage T2 values. Regions were considered statistically significantly different if the mean T2 values between groups differed at P < 0.05. RESULTS: Mean cartilage T2 profiles were nearly identical for the 2 youngest cohorts. Compared with the 18-30-year-old group, T2 values were statistically significantly longer in the superficial 40% of cartilage in the 46-65-year-old group and over the entire cartilage thickness in the 66-86-year-old group. CONCLUSION: The location of T2 elevations in women over the age of 45 years is consistent with the theory that senescent changes of cartilage collagen begin near the articular surface and progress to the deeper cartilage with advancing age.

Adolescent↗

Phantom design method for high-field MRI human systems.

A phantom design method suitable for high-field MRI based on the RF field wave characteristics of sample and experimental validations at 7.0 T and 3.0 T are presented. The RF field distribution in a phantom with a given RF coil system is primarily determined by the sample size relative to the wavelength inside the sample, and the ratio between the displacement and conduction currents. Experimental results demonstrate that the MR image intensity patterns associated with wave behavior in human samples at a given field strength can be reproduced with a phantom at the same or different field strengths once the dimension and penetration constant are scaled by the corresponding wavelength in the sample medium.

Brain Mapping↗

Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field.

Geometric distortion, signal-loss, and image-blurring artifacts in echo planar imaging (EPI) are caused by frequency shifts and T(2)(*) relaxation distortion of the MR signal along the k-space trajectory due to magnetic field inhomogeneities. The EPI geometric-distortion artifact associated with frequency shift can be reduced with parallel imaging techniques such as SENSE, while the signal-loss and blurring artifacts remain. The gradient-echo slice excitation profile imaging (GESEPI) method has been shown to be successful in restoring tissue T(2)(*) relaxation characteristics and is therefore effective in reducing signal-loss and image-blurring artifacts at a cost of increased acquisition time. The SENSE and GESEPI methods are complementary in artifact reduction. Combining these two techniques produces a method capable of reducing all three types of EPI artifacts while maintaining rapid acquisition time.

Artifacts↗

Analysis of wave behavior in lossy dielectric samples at high field.

Radiofrequency (RF) field wave behavior and associated nonuniform image intensity at high magnetic field strengths are examined experimentally and numerically. The RF field produced by a 10-cm-diameter surface coil at 300 MHz is evaluated in a 16-cm-diameter spherical phantom with variable salinity, and in the human head. Temporal progression of the RF field indicates that the standing wave and associated dielectric resonance occurring in a pure water phantom near 300 MHz is greatly dampened in the human head due to the strong decay of the electromagnetic wave. The characteristic image intensity distribution in the human head is the result of spatial phase distribution and amplitude modulation by the interference of the RF traveling waves determined by a given sample-coil configuration. The numerical calculation method is validated with experimental results. The general behavior of the RF field with respect to the average brain electrical properties in a frequency range of 42-350 MHz is also analyzed.

Electromagnetic Phenomena↗

Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0 T.

The RF field intensity distribution in the human brain becomes inhomogeneous due to wave behavior at high field. This is further complicated by the spatial distribution of RF field polarization that must be considered to predict image intensity distribution. An additional layer of complexity is involved when a quadrature coil is used for transmission and reception. To study such complicated RF field behavior, a computer modeling method was employed to investigate the RF field of a quadrature surface coil at 300 MHz. Theoretical and experimental results for a phantom and the human head at 7.0 T are presented. The results are theoretically important and practically useful for high-field quadrature coil design and application.

Brain↗

Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head.

Susceptibility-induced perturbation of the static magnetic field by the human body during magnetic resonance imaging (MRI) leads to undesirable artifacts as well as valuable physiological information, as in functional MRI. The ability to calculate these perturbations for a multi-tissue human body model provides a powerful tool in designing hardware and acquisition methods for reducing the artifacts, and in relating observed image contrast to physiological origins. We have developed a method for calculating the static field in arbitrary 3D magnetic susceptibility distributions and performed calculations in a complete model of the human head and shoulders. The accuracy of our method was validated in regular geometries with known analytical solutions and in comparison with experimental results acquired from the head of the same human subject used for computer modeling. Results are presented in parts per million (ppm) deviation from the applied field strength and are valid for any imaging or spectroscopy system.

Computer Simulation↗

Intrinsic muscle atrophy and toe deformity in the diabetic neuropathic foot: a magnetic resonance imaging study.

OBJECTIVE: The objectives of this study were to compare intrinsic foot muscle cross-sectional area (CSA) in patients with diabetic polyneuropathy and nondiabetic control subjects and to examine the association between intrinsic muscle CSA and clawing/hammering of the toes in neuropathic feet. RESEARCH DESIGN AND METHODS: High-resolution T2-weighted fast spin-echo images and parametric T2 multiple spin-echo images were acquired using multiple spin-echo magnetic resonance imaging (MRI) of frontal plane sections of the metatarsal region of the foot in a sample of eight individuals with diabetic polyneuropathy and eight age- and sex-matched nonneuropathic nondiabetic control subjects. The configuration of joints of the second toe was obtained using a three-dimensional contact digitizer. RESULTS: Remarkable atrophy was found in all the intrinsic muscles of neuropathic subjects as compared with nondiabetic control subjects. Quantitative T2 analysis showed a 73% decrease in muscle tissue CSA distally in the neuropathic subjects. Muscle comprised only 8.3 +/- 2.9% (means +/- SD) of total foot CSA compared with 30.8 +/- 3.9% in control subjects. No significant differences were found between the groups in the metatarso-phalangeal and proximal and distal interphalangeal joint angles of the second ray. Moreover, clawing/hammering of the toes was found in only two of eight neuropathic subjects. CONCLUSIONS: Although sensory neuropathy is often emphasized in considerations of diabetic foot pathology, our results show that the consequences of motor neuropathy in the feet are profound in people with diabetes. This has implications for foot function and may play a significant role in postural instability. However, intrinsic muscle atrophy does not necessarily appear to imply toe deformity.

Adult↗

Two dimensional prolate spheroidal wave functions for MRI.

The tradeoff between spatial and temporal resolution is often used to increase data acquisition speed for dynamic MR imaging. Reduction of the k-space sampling area, however, leads to stronger partial volume and truncation effects. A two dimensional prolate spheroidal wave function (2D-PSWF) method is developed to address these problems. Utilizing prior knowledge of a given region of interest (ROI) and the spatial resolution requirement as constraints, this method tailors the k-space sampling area with a matching 2D-PSWF filter so that optimal signal concentration and minimal truncation artifacts are achieved. The k-space sampling area is reduced because the shape and size of the sampling area match the resolution posed by the non-rectangular shape of a convex ROI. The 2D-PSWF method offers an efficient way for spatial and temporal tradeoff with minimal penalty due to truncation, and thus, it promises a wide range of applications in MRI research.

Adult↗