PubMed Health⌕ Search

Biomedical subjects

Qingshan Chen

Publications and source records attributed to Qingshan Chen.

14 recordsLinked to original sources

The 13-lipoxygenase GmLOX6 is involved in JA biosynthesis and serves as a positive regulator of salt stress tolerance in soybean.

Salinity represents a major abiotic stressor that significantly impairs soybean growth and yield. Although jasmonic acid (JA) has been firmly established as a key regulator of plant defense against salt stress, the precise functions of lipoxygenase (LOX) genes responsible for initiating JA biosynthesis remain poorly defined. Here, a comprehensive genome-wide analysis of the soybean LOX gene family was performed, and a detailed functional characterization of GmLOX6 was carried out. Subcellular localization confirmed that GmLOX6 is targeted to chloroplasts, while enzymatic assays demonstrated that it acts as a 13-LOX enzyme with a strong preference for α-linolenic acid as substrate. To clarify its role under salt stress, we generated both overexpression and CRISPR/Cas9-mediated knockout lines of soybean. Phenotypic and molecular evaluations revealed that GmLOX6 facilitates JA production under salt stress, thereby contributing to enhanced JA accumulation. This elevation in JA levels was associated with improved salt tolerance through multiple physiological adaptations, including the activation of antioxidant enzymes for the detoxification of reactive oxygen species (ROS), enhanced Na+ extrusion to preserve ionic balance, and reinforced membrane stability. Moreover, GmRWP-RK11 was identified as a transcriptional repressor of GmLOX6. Functional disruption of GmRWP-RK11 via CRISPR/Cas9 conferred greater salt tolerance, further supporting its negative regulatory role. Collectively, these findings uncover a novel regulatory axis in which GmLOX6-mediated JA biosynthesis enhances soybean resistance to salinity through modulation of ROS homeostasis and Na+ transport. These insights provide an expanded understanding of the transcriptional and biochemical mechanisms underpinning JA-driven stress adaptation in soybean.

Glycine max↗

The relation between micromotion and screw fixation in acetabular cup.

One of the major causes inducing loosening in the cementless acetabular cup implanting is its insufficient initial stability. In this study, three-dimensional finite element models of the pelvis and acetabular components were developed to investigate the relationship between relative micromotion, initial stability, and screw fixation under six daily activity loadings. A commercial available hemispheric cup with five screw holes was used as the target acetabular cup. The simulation results showed that if screws were placed closed together, when the screw number increased from 1 to 5, the peak micromotion decreased less than 14%, from 126.5 to 108.8 microm, while the stable region, micromotion less than 28 microm, enlarged only by 40%, from 46.1% to 64.7%. However, if the screw could be placed near the cup rim, a single rim screw, 202.1 microm micromotion, could provide better stability than that of four dome screws, 209.6 microm micromotion, placed closed together. To conclude, multiple cup screws should be placed near cup rim and as separate as possible to enlarge the stable region and reduce the peak micromotion between cup and acetabulum.

Acetabulum↗

Determination of thigh muscle stiffness using magnetic resonance elastography.

PURPOSE: To measure the elastic properties of the vastus lateralis (VL), vastus medialis (VM), and sartorius (Sr) muscles using magnetic resonance elastography (MRE). MATERIALS AND METHODS: To obtain a normative database of the aforementioned muscles, oblique scan directions were prescribed passing through each muscle. Shear waves were induced into the muscles using pneumatic and mechanical drivers at 90 and 120 Hz, respectively. These drivers were attached to the distal end of the right thigh with the knee flexed at 30 degrees . The foot was placed in a footplate containing MR-compatible load cells to record the force during a contraction (10% and 20% of the maximum voluntary contraction). RESULTS: The shear moduli measured at rest in the VL (N = 12), VM (N = 14), and Sr (N = 13) were 3.73 +/- 0.85 kPa, 3.91 +/- 1.15 kPa, and 7.53 +/- 1.63 kPa, respectively. The stiffness of both vasti increased with the level of contraction, while the stiffness of the Sr remained the same. CONCLUSION: The MRE technique was able to approximate the stiffness of different thigh muscles. Furthermore, the wave length was sensitive to the morphology (unipennate or longitudinal) and fiber composition (type I or II) in each muscle.

Adult↗

Surgical treatment of femoroacetabular impingement: evaluation of the effect of the size of the resection. Surgical technique.

BACKGROUND: In patients with symptomatic hip impingement, surgical resection of the femoral head-neck junction may improve the range of motion and relieve pain. A risk of this procedure is fracture. We evaluated the amount of resection of the anterolateral aspect of the femoral head-neck junction that can be done safely. METHODS: Cadaveric proximal femoral specimens (fifteen matched pairs) were divided into three groups: 10%, 30%, or 50% of the diameter of one femoral neck was removed, and the contralateral femoral neck was left intact to serve as the control. A compressive load was applied directly to the femoral head. Peak load, stiffness, and energy to fracture were compared among the groups. RESULTS: The energy to fracture differed significantly (p = 0.0015) among the 10%, 30%, and 50% resection groups. The peak load after the 50% resection was significantly less (p = 0.0025) than that after the 10% or 30% resection. With the numbers available, there was no significant difference in peak load between the 10% and 30% resections. CONCLUSIONS: Resection of up to 30% of the anterolateral quadrant of the head-neck junction did not significantly alter the load-bearing capacity of the proximal part of the femur. However, a 30% resection significantly decreased the amount of energy required to produce a fracture. Thirty percent should be considered to be the greatest feasible amount of resection because of the change in the pattern of the femoral head-neck response to axial loads that we observed.

Acetabulum↗

Quantitative trait loci analysis for the developmental behavior of Soybean (Glycine max L. Merr.).

Quantitative trait loci (QTLs) identified so far in soybean were mainly derived in the final stage of plant development, which did not apply to the exploitation of genetic effects that were expressed during a specific developmental stage. Thus, the aim of this study was to identify conditional QTLs associated with yield traits at a specific developmental interval of soybean plant. The 143 recombinant inbred lines developed from the cross of soybean cultivars 'Charleston' and 'Dongnong 594' were used for the developmental QTLs analysis of pod number in the main stem and plant height by composite interval mapping method combined with mixed genetic model. The results indicated that the number and type of QTLs and their genetic effects for the two agronomic traits were different in a series of measuring stages. A total of 10 unconditional QTLs in 6 linkage groups and 5 conditional QTLs in 3 linkage groups were identified for the pod number of the main stem, while 13 unconditional QTLs in 7 linkage groups and 12 conditional QTLs in 6 linkage groups were identified for plant height. Many QTLs that were detected in the early stages were different from those detected at the later stages. Some QTLs existed only at one stage and others existed across two or three stages. Five marker intervals (satt509-satt251, sat_099-sat_113, sat_113-OPAW19_4, satt457-OPC10_85, sat_095-OPBA08_5) were proven to be associated both with the development of pod number in the main stem and the development of plant height. The present study suggested that the development of pods and plant height in soybean were governed by time-dependent gene expression.

Chromosome Mapping↗

Differential effects of pre-tension on shear wave propagation in elastic media with different boundary conditions as measured by magnetic resonance elastography and finite element modeling.

Magnetic resonance elastography (MRE) can non-invasively determine material stiffness based on the propagating shear wavelength. Shear wave propagation in a finite homogenous isotropic material can be affected by multiple factors. In this study we examined the effects of pre-tension and frequency on MRE shear measurements of gel phantoms with different boundary conditions, frequencies, and geometries. Results from MRE measurements were compared to wave motion theory in elastic solids and qualitatively to a finite element (FE) model. Results indicated that boundary conditions, geometry and pre-tension are important factors to be considered when performing MRE tests on a finite material, and that FE modeling can help explore how the shear wave propagation is affected under various boundary conditions and axial stresses, among other potential factors.

Biocompatible Materials↗

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamically, while compression tests convert the measured elastic modulus to shear modulus with an assumed Poisson ratio. This study compared the shear stiffness estimated with various MRE inversion algorithms (i.e., manual calculation, local frequency estimate, phase gradient, direct inversion, and matched filter) to the dynamic mechanical test. The shear stiffness of five agarose gels with concentrations ranging from 1.5 to 3.5% were measured using MRE and DMA. The phase gradient inversion algorithm overestimated the shear modulus at higher concentrations (i.e., 3-3.5% agar), while the results from the other techniques correlated well with the dynamic mechanical test.

Agar↗

Identification of the testing parameters in high frequency dynamic shear measurement on agarose gels.

Dynamic mechanical analysis (DMA) on agarose gels can be used to validate magnetic resonance elastography (MRE) measurements as well as to provide better understanding for the biological responses of cells to the dynamic loadings in cell culture studies. Various parameters potentially affecting the repeatability and accuracy of the DMA shear modulus measurements were investigated systematically in the present study, including sample thickness, shear strain, testing frequency, and compressive clamping strain. The study showed that the thickness of the agarose gel sample must be sufficiently small (1 mm) to prevent the erroneous fluctuation in the measured modulus. The appropriate levels of shear strain (< or = 0.5%) and compressive clamping strain (5-10%) must be applied to overcome the slippage at the gel-clamp interface without causing significant boundary and stress non-uniformity or micro-cracks in the agarose gel sample.

Cell Culture Techniques↗

Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

Algorithms↗

Surgical treatment of femoroacetabular impingement: evaluation of the effect of the size of the resection.

BACKGROUND: In patients with symptomatic hip impingement, surgical resection of the femoral head-neck junction may improve the range of motion and relieve pain. A risk of this procedure is fracture. We evaluated the amount of resection of the anterolateral aspect of the femoral head-neck junction that can be done safely. METHODS: Cadaveric proximal femoral specimens (fifteen matched pairs) were divided into three groups: 10%, 30%, or 50% of the diameter of one femoral neck was removed, and the contralateral femoral neck was left intact to serve as the control. A compressive load was applied directly to the femoral head. Peak load, stiffness, and energy to fracture were compared among the groups. RESULTS: The energy to fracture differed significantly (p = 0.0015) among the 10%, 30%, and 50% resection groups. The peak load after the 50% resection was significantly less (p = 0.0025) than that after the 10% or 30% resection. With the numbers available, there was no significant difference in peak load between the 10% and 30% resections. CONCLUSIONS: Resection of up to 30% of the anterolateral quadrant of the head-neck junction did not significantly alter the load-bearing capacity of the proximal part of the femur. However, a 30% resection significantly decreased the amount of energy required to produce a fracture. Thirty percent should be considered to be the greatest feasible amount of resection because of the change in the pattern of the femoral head-neck response to axial loads that we observed.

Aged↗

Clinical observation on juvenile macular hole without trauma and hypermyopia.

PURPOSE: To investigate the clinical characteristics of juvenile macular hole without trauma and hypermyopia, and research the mechanism of macular hole. METHODS: Sixty-seven patients less than 40 years of age were studied retrospectively from June 1998 to March 2003. Five cases (7 eyes) aged from 22 to 38 years were reported and the clinical characteristics that had macular hole without trauma or hypermyopia were summed up. RESULTS: There was 1 male and 4 females with visual acuity from 0.08 to 0.8. The images of optical coherence tomography (OCT) showed full thickness macular hole in 5 patients (7 eyes), and the diameters were from 87 to 1043 microm. Among them, 2 cases were combined with retina pigmentosa; 1 case with binocular Coat's disease; 1 case had bilateral macular hole combined with Eagles' disease; 1 case was combined with 2-2.5PD old retinochoroidal lesion under middle-peripheral fundus, and 1.5 PD retinal pigment epithelium (RPE) defect on the optical disk. CONCLUSION: The juvenile macular hole without trauma and hypermyopia combined the different retina vascular damages and the RPE defects.

Adult↗

A finite element model for analyzing shear wave propagation observed in magnetic resonance elastography.

Magnetic resonance elastography (MRE) is a novel non-invasive approach to determine material stiffness by using a conventional magnetic resonance imaging (MRI) system incorporated with an oscillating motion-sensitizing gradient to detect nodal displacements produced by a shear excitation wave. The effects of material properties, excitation frequency, boundary conditions, and applied tension on shear wavelength measurement must be examined before MRE can become a useful diagnostic tool. We propose finite element (FE) modeling as a robust method to systematically study the effects of these parameters. An axisymmetric FE model was generated with ABAQUS to simulate agarose gel phantoms. The effects of material stiffness, density, and excitation frequency on propagating shear wavelength were examined individually. The effect of the boundary conditions on shear wavelength was also demonstrated. Results of shear wavelength from MRE measurement were compared with the results of FE model, which showed good agreement between the methods.

Biomechanical Phenomena↗

Dynamic mechanical properties of agarose gels modeled by a fractional derivative model.

The complex modulus (E*) and elastic modulus (E') of agarose gels (2% to 4%) are measured with a dynamic mechanical analyzer in frequency sweep shear sandwich mode between 0.1 and 20 Hz. The data showed that E* and E' increase with frequency according to a power law which can be described by a fractional derivative model to characterize the dynamic viscoelasticity of the gel. The functions between the model parameters including storage modulus coefficient (H) and the power law exponent (beta) and the agarose concentration are established. A molecular basis for the application of the fractional derivative model to gel polymers is also discussed. Such an approach can be useful in tissue culture studies employing dynamic pressurization or for validation of magnetic resonance elastography.

Biocompatible Materials↗

Both constitutive and inducible prostaglandin H synthase affect dermal wound healing in mice.

In an attempt to define the roles of prostaglandin H synthase 1 (PGHS-1, cyclooxygenase-1, COX-1) and prostaglandin H synthase 2 (PGHS-2, cyclooxygenase-2, COX-2) in wound healing, we investigated the healing of incisional dermal wounds in wild-type, PGHS-1 null, and PGHS-2 null mice. We measured tensile strength of the wounds, levels of PGHS-1 and PGHS-2 mRNA in the wound site, and histologic markers for the inflammatory, proliferative, and remodeling phases of wound healing. Although no gross visible differences were noted among healed wounds of the different mouse types, measurement of tensile strength showed that both PGHS-1 and PGHS-2 null wounds were weaker (75% and 70%, respectively) than wild-type wounds at 12 days after incision. At Day 8 the endothelial staining was 70% greater in the wounds of PGHS-2 null mice compared with their wild-type counterparts. In contrast at Day 12, staining for macrophages and myofibroblasts was less in PGHS-1 null wounds compared with wild-type and PGHS-2 null tissue. Compensatory expression of the alternate PGHS mRNA could be demonstrated by RT-PCR in the wounds of PGHS null mice on Days 1 and 4. We conclude that both PGHS-1 and PGHS-2 genes play distinct roles in the process of dermal wound healing.

Animals↗