PubMed Health⌕ Search

Biomedical subjects

Qiongguo Mao

Publications and source records attributed to Qiongguo Mao.

2 recordsLinked to original sources

[Experimental studies of carcino-embryonic antigen immunosensor based on piezoelectric resonate technology of quartz crystal].

In order to construct a new type of piezoelectric quartz immunosensor for the determination of carcino-embryonic antigen (CEA), the sensor detection pools were consisted of plastic loops and crystals that were 10 MHz quartz AT-cut with gold coated electrodes and the immobilization of the monoclonal antibody against CEA onto gold electrode surface of the quartz crystal was accomplished via Thiol method. Then the immunosensors were used in clinical laboratory. The experimental results showed that the piezoelectric immunosensor had good response to CEA, the frequency shifts were linearly dependent on CEA concentration in the range of 1.56 to approximately 50.00 ng/ml, other antigens such as alpha fetoprotein (AFP), prostate specific antigen (PSA), human chorionic gonadotropin (hCG) did not interfere with the sensor's response. The results obtained from this method were in satisfactory accordance with those obtained by radio immunoassay(P>0.05), The correlation coefficient was 0.90. Piezoelectric immunosensor for determination of CEA has the advantage of high sensitivity, high specificity, unnecessary labeling, simple performing, rapid analysis, low cost, real-time detection and repeated use, etc. It can be used for detecting serum CEA in clinical laboratory.

Antibodies, Monoclonal↗

A novel piezoelectric quartz micro-array immunosensor based on self-assembled monolayer for determination of human chorionic gonadotropin.

A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.

Biosensing Techniques↗